Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Rayleigh Scattering Diagnostic for Measurement of Temperature, Velocity, and Density Fluctuation Spectra

A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 10 kHz. A high power CW laser beam is focused at a point in a heated air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature, velocity, and density of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 10 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. Power spectral density calculations of temperature, velocity, and density fluctuations, as well as mean and fluctuating quantities are demonstrated for various radial locations in the jet flow at a fixed axial distance from the jet exit plane. Results are compared with constant current anemometry and pitot probe measurements at the same locations.

Mielke, Amy F.↗

Semi-empirical quantum optics for mid-infrared molecular nanophotonics

Nanoscale infrared (IR) resonators with sub-diffraction limited mode volumes and open geometries have emerged as new platforms for implementing cavity quantum electrodynamics at room temperature. The use of IR nanoantennas and tip nanoprobes to study strong light–matter coupling of molecular vibrations with the vacuum field can be exploited for IR quantum control with nanometer spatial and femtosecond temporal resolution. In order to advance the development of molecule-based quantum nanophotonics in the mid-IR, we propose a generally applicable semi-empirical methodology based on quantum optics to describe light–matter interaction in systems driven by mid-IR femtosecond laser pulses. The theory is shown to reproduce recent experiments on the acceleration of the vibrational relaxation rate in infrared nanostructures. It also provides physical insights on the implementation of coherent phase rotations of the near-field using broadband nanotips. We then apply the quantum framework to develop general tip-design rules for the experimental manipulation of vibrational strong coupling and Fano interference effects in open infrared resonators. We finally propose the possibility of transferring the natural anharmonicity of molecular vibrational levels to the resonator near-field in the weak coupling regime to implement intensity-dependent phase shifts of the coupled system response with strong pulses and develop a vibrational chirping model to understand the effect. The semi-empirical quantum theory is equivalent to first-principles techniques based on Maxwell’s equations, but its lower computational cost suggests its use as a rapid design tool for the development of strongly coupled infrared nanophotonic hardware for applications ranging from quantum control of materials to quantum information processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method and apparatus for producing an image from a transparent object

The contrast produced from a photographic transparency is controlled by placing the transparency between a pair of partially reflecting mirrors forming walls of an optical cavity. Mirrors trap a collimated laser beam illuminating the transparency so that at least a portion of the beam energy is passed through the transparency plural times. The distance that the light beam travels between the mirrors is controlled as a function of the wavelength of the beam energy to control the phase of light interference in the beam passing through the transparency, thereby controlling the intensity of the beam derived from the mirror downstream of the transparency.

Lee, S. H.↗

Molecular structure retrieval directly from laboratory-frame photoelectron spectra in laser-induced electron diffraction

Ubiquitous to most molecular scattering methods is the challenge to retrieve bond distance and angle from the scattering signals since this requires convergence of pattern matching algorithms or fitting methods. This problem is typically exacerbated when imaging larger molecules or for dynamic systems with little a priori knowledge. Here, we employ laser-induced electron diffraction (LIED) which is a powerful means to determine the precise atomic configuration of an isolated gas-phase molecule with picometre spatial and attosecond temporal precision. We introduce a simple molecular retrieval method, which is based only on the identification of critical points in the oscillating molecular interference scattering signal that is extracted directly from the laboratory-frame photoelectron spectrum. The method is compared with a Fourier-based retrieval method, and we show that both methods correctly retrieve the asymmetrically stretched and bent field-dressed configuration of the asymmetric top molecule carbonyl sulfide (OCS), which is confirmed by our quantum-classical calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tunable diode laser measurements of absolute linestrengths in the HNO3 band near 5.8 microns

Absolute line strengths of selected lines in the nu 2 band of HNO3 have been measured using a tunable diode laser spectrometer operating in a sweep integration mode. The direct measurement technique has been employed to obtain line intensities at 296 K for 22 isolated lines in the 1720-1725/cm region. The reported line strengths have estimated uncertainties of 4 percent, a significant portion of this uncertainty arising from spectral interference from hot band transitions. From these line-strength measurements, an integrated band intensity of 1375/sq cm per atm at 296 K is inferred.

May, Randy D.↗

Micro pulse lidar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering has been demonstrated. The transmitter of the micropulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited by optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that systems built on the micropulse lidar concept are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Micro pulse laser radar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering is disclosed. The transmitter of the micro pulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited to optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that micropulse lider systems are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Speckle techniques for determining stresses in moving objects

Laser speckle interferometry is a relatively new experimental technique which shows promise of alleviating many difficult problems in experimental mechanics. The method utilizes simple high-resolution photographs of the surface which is illuminated by coherent light. The result is a real-time or permanently stored whole-field record of interference fringes which yields a map of displacements in the object. In this thesis, the time-average theory using the Fourier transform is developed to present the application of this technique to measurement of in-plane displacement induced by the vibration of an object.

Murphree, E. A.↗

Velocity servo for continuous scan Fourier interference spectrometer

A velocity servo for continuous scan Fourier interference spectrometer of the double pass retroreflector type having two cat's eye retroreflectors is described. The servo uses an open loop, lead screw drive system for one retroreflector with compensation for any variations in speed of drive of the lead screw provided by sensing any variation in the rate of reference laser fringes, and producing an error signal from such variation used to compensate by energizing a moving coil actuator for the other retroreflector optical path, and energizing (through a highpass filter) piezoelectric actuators for the secondary mirrors of the retroreflectors.

Schindler, R. A.↗

Dynamic Measurement of Temperature, Velocity, and Density in Hot Jets Using Rayleigh Scattering

A molecular Rayleigh scattering technique was utilized to measure time-resolved gas temperature, velocity, and density in unseeded gas flows at sampling rates up to 10 kHz. A high power continuous-wave (cw) laser beam was focused at a point in an air flow field and Rayleigh scattered light was collected and fiber-optically transmitted to a Fabry-Perot interferometer for spectral analysis. Photomultipler tubes operated in the photon counting mode allowed high frequency sampling of the total signal level and the circular interference pattern to provide time-resolved density, temperature, and velocity measurements. Mean and rms velocity and temperature, as well as power spectral density calculations, are presented for measurements in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at the NASA Glenn Research Center (GRC). The Rayleigh measurements are compared with particle image velocimetry data and CFD predictions. This technique is aimed at aeronautics research related to identifying noise sources in free jets, as well as applications in supersonic and hypersonic flows where measurement of flow properties, including mass flux, is required in the presence of shocks and ionization occurrence.

Mielke, Amy F.↗

Interference-free optical detection for Raman spectroscopy

An architecture for spontaneous Raman scattering (SRS) that utilizes a frame-transfer charge-coupled device (CCD) sensor operating in a subframe burst gating mode to realize time-resolved combustion diagnostics is disclosed. The technique permits all-electronic optical gating with microsecond shutter speeds (<5 .mu.s), without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally-polarized excitation lasers, the technique measures time-resolved vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Nguyen, Quang-Viet↗

Dynamic Measurement of Temperature, Velocity, and Density in Hot Jets Using Rayleigh Scattering

A molecular Rayleigh scattering technique is utilized to measure gas temperature, velocity, and density in unseeded gas flows at sampling rates up to 10 kHz, providing fluctuation information up to 5 kHz based on the Nyquist theorem. A high-power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to a Fabry-Perot interferometer for spectral analysis. Photomultiplier tubes operated in the photon counting mode allow high-frequency sampling of the total signal level and the circular interference pattern to provide dynamic density, temperature, and velocity measurements. Mean and root mean square velocity, temperature, and density, as well as power spectral density calculations, are presented for measurements in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA John H. Glenn Research Center at Lewis Field. The Rayleigh measurements are compared with particle image velocimetry data and computational fluid dynamics predictions. This technique is aimed at aeronautics research related to identifying noise sources in free jets, as well as applications in supersonic and hypersonic flows where measurement of flow properties, including mass flux, is required in the presence of shocks and ionization occurrence.

Mielke, Amy F.↗

Optical Vortices with Large Orbital Momentum: Generation and Interference

We demonstrate a method for generation of beams of light with large angular momenta. The method utilizes whispering gallery mode resonators that transform a plane electromagnetic wave into high order Bessel beams. Interference pattern among the beams as well as shadow pictures induced by the beams are observed and studied.

diffraction theory↗

Remote Raman Spectroscopy of Minerals at Elevated Temperature Relevant to Venus Exploration

We have used a remote time-resolved telescopic Raman system equipped with 532 nm pulsed laser excitation and a gated intensified CCD (ICCD) detector for measuring Raman spectra of a number of minerals at high temperature to 970 K. Remote Raman measurements were made with samples at 9-meter in side a high-temperature furnace by gating the ICCD detector with 2 micro-sec gate to minimize interference from blackbody emission from mineral surfaces at high temperature as well as interference from ambient light. A comparison of Raman spectra of gypsum (CaSO4.2H2O), dolomite (CaMg(CO3)2), and olivine (Mg2Fe2-xSiO4), as a function of temperature shows that the Raman lines remains sharp and well defined even in the high-temperature spectra. In the case of gypsum, Raman spectral fingerprints of CaSO4.H2O at 518 K were observed due to dehydration of gypsum. In the case of dolomite, partial mineral dissociation was observed at 973 K at ambient pressure indicating that some of the dolomite might survive on Venus surface that is at approximately 750 K and 92 atmospheric pressure. Time-resolved Raman spectra of low clino-enstatite (MgSiO3) measured at 75 mm from the sample in side the high-temperature furnace also show that the Raman lines remains sharp and well defined in the high temperature spectra. These high-temperature remote Raman spectra of minerals show that time-resolved Raman spectroscopy can be used as a potential tool for exploring Venus surface mineralogy at shorter (75 mm) and long (9 m) distances from the samples both during daytime and nighttime. The remote Raman system could also be used for measuring profiles of molecular species in the dense Venus atmosphere during descent as well as on the surface.

Sharma, Shiv K.↗

[Measurements of "Total Water" and Carbon Dioxide from the NASA WB-57 During Crystal-Face]

An existing closed-path tunable diode laser hygrometer (CLH) was employed for the measurements of total water made during CRYSTAL-FACE. This instrument had flown previously on the NASA DC-8 during the SAGE III Ozone Loss and Validation Experiment (SOLVE) and also on the NCAR C-130 during some local flights designed to test the extent of water vapor interference in carbon dioxide measurements. The instrument was largely unchanged from previous studies, but a new inlet appropriate to the WB-57F wingpod was constructed. In order to minimize the impact on the over-subscribed right wingpod and to achieve good thermal control of the inlet temperature, the CLH inlet was made of carbon-fiber/epoxy composite. Considerable effort was spent to design and build the lightest possible mounting hardware and design relatively low-power inlet heaters. As a result, the instrument and mounting hardware came in below the NASA/JSC-imposed weight cap of 35 lbs. Data were obtained on all test flights during May 2002 and during all but one mission flight in July 2002 (the one lost flight was due to an unplugged instrument power cable). Instrument performance during the test flights was good, but the data are not science- quality, as a variety of tests were performed to optimize the inlet configuration and heating. Data on all mission flights is of high quality, despite some difficulties caused by flying through wet low-altitude air masses and dense anvils, which saturated the instrument response.

Avallone, Linnea M.↗

Laserfax

The photo shows an Associated Press technician receiving a photograph prepared by means of a high speed, high resolution facsimile system known as Laserfax, so called because it employs a laser beam to scan the photo being sent. Laser scanning data is converted to electrical signals and transmitted to news bureaus within the Associated Press network via microwave radio or telephone lines. At the other end, another laser sweeps reconverted imagery onto a special, light-sensitive, dry silver paper. The paper is then heat processed to reproduce the photograph. Manufactured by Harris Electronics Systems Inc., Melbourne, Florida, Laserfax incorporates NASA thermal control coating technology developed by Jet Propulsion Laboratory for use on spacecraft antennas; the coatings block absorption of solar radiation which would interfere with the antenna's proper operation. Harris Electronics Systems, originally Radiation, Inc., reused the NASA technology in development of Laserfax. A NASA technical support package provided information about the thermal properties that could be expected of various coatings for the facsimile system's paper rollers; this information served as a design base for the infrared heat source used in developing the photo. Although relatively new, Laserfax is in extensive service. It is manufactured in several models. One of them is the type used by the Associated Press, its news bureaus and affiliated newspapers, radio and television stations. Other models have been sold in large numbers to law enforcement agencies for transmitting high quality fingerprints and identification photos. Laserfax is also in service with the National Weather Service, which converts satellite imagery to weather photographs and relays them to local weather stations, television stations, newspapers and airlines.

Source record↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗