Quasi-In-Situ Analysis of Electrode Top Atomic Layers via High-Sensitivity Low-Energy Ion Scattering and Potential-Controlled Sample Transfer

Electrocatalytic reactions involve interfacial interactions between the surfaces of electrodes and reactive species at an electrolyte interface. There are presently no universal or unambiguous methods to directly assay the active top atomic layer composition that influences the reactivity of these electrodes under relevant operating conditions. Low-energy ion scattering (LEIS) spectroscopy is a surface characterization technique that yields compositional analysis of the outermost atomic layer of a material, but it must be performed in ultrahigh vacuum (UHV). Application of LEIS measurements to electrochemical materials that are removed from ambient liquid-phase environments thus leaves an open question as to whether the surface that is transferred to UHV is truly the surface that manifested during the electrochemical reaction. Toward the goal of preserving the active surface state, we developed a sample transfer workflow for LEIS enabling air-free removal and drying of an electrode from an electrochemical cell while maintaining control of the potential using an auxiliary electrode. The potential-controlled emersion method was demonstrated to give distinct potential-dependent surface compositions for a Cu−Pd alloy relative to removal after uncontrolled return to open-circuit potential. A Cu-enriched surface was found at anodic potential and a Pd-enriched surface at cathodic potential, suggesting that the approach can be used to retain representative atomic configurations during transfer. Since adsorbates will often persist from the reaction environment, conventional sample pretreatment methods for removal, including atomic O and atomic H exposure, were also contrasted. Both methods were found to differ with results from incidental low-dose depth profiling by the LEIS primary ion source, which removes adventitious species and surface atoms during the course of repeated measurements. These depth profiles were found to be sensitive to sample history and thus qualitatively informative, despite the possible changes induced by ion damage. The results exhibit (i) the need for complete control over the polarization state of the sample at all times (no excursions to open circuit during transfer) and (ii) the utility of low-dose depth profiling to capture changes in the near-surface composition.

Alloys↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused x-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. It is observed that these transient shape characteristics depend on the source (ion, x-ray, or laser), even when similar amounts of charge are generated. Finally, the observed differences are examined and explained in terms of basic charge collection mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atomic nitrogen measurements in the upper thermosphere

The open source neutral mass spectrometer on board the Atmosphere Explorer satellites measures, besides other neutral constituents, atomic nitrogen densities in the upper thermosphere. Atomic nitrogen combines with atomic oxygen on the walls of the mass spectrometer ion source to form NO. From the measured NO concentration atomic nitrogen is deduced. Studies of the diurnal variation show that the maximum atomic nitrogen densities occur near 1600 local solar time (LST) and minimum densities near 0400 LST. The diurnal amplitude at 300 km is about a factor of 8, which is lower than predicted in present models. Atomic nitrogen also exhibits a pronounced seasonal variation with an amplitude similar to that of the diurnal variation; summer values are considerably higher than winter ones.

Mauersberger, K.↗

Status of the Spallation Neutron Source beam test facility and progress of beam dynamics studies

The Spallation Neutron Source (SNS) Beam Test Facility (BTF) supports the study of beam dynamics in the front end of a high power LINAC. The BTF combines a replica of the SNS front end, including nearly-identical ion source, RFQ and MEBT, with extensive phase space diagnostics and a FODO transport line. Diagnostic capabilities include direct measurement of 6D phase space distribution and detection of halo distributions to a sensitivity of greater than one part-per-million. The goal of on-going BTF studies is to demonstrate accurate particle-in-cell modeling of halo growth and evolution by leveraging unprecedented accuracy in the description of the initial beam distribution. This work is motivated by operational experience at the SNS, which currently operates with beam loss that cannot be described by any model. This paper summarizes progress in the BTF beam study program as well as diagnostics development and recent upgrades to the beamline configuration.

Ruisard, Kiersten↗

Facility upgrade for superheavy-element research at RIKEN

The RIKEN Nishina Center (RNC) executed an accelerator upgrade project for the heavy-ion linac (called RILAC). A superconducting RIKEN linear accelerator (SRILAC) and a new superconducting electron-cyclotron-resonance ion source (SC-ECRIS) to boost the final energy and intensity were constructed, aimed at synthesizing a new superheavy element, 119, through a hot fusion reaction. The project included the construction of a gas-filled recoil ion separator (GARIS-III) suitable for detecting the residues of the hot-fusion reaction. To avoid research interruption during the SRILAC construction period (2017–2019) and gain experience in hot-fusion reaction processes, GARIS-II located in the GARIS experimental hall in LINAC building was moved to the E6 experimental hall in Nishina building. Certain exploratory measurements were performed employing the beams accelerated by RILAC2 and the RIKEN ring cyclotron (RRC), which is a part of the existing accelerator complex of the radioactive isotope beam factory (RIBF). Further, commissioning experiments with the upgraded facility (SRILAC and GARIS-III) were performed. The upgrade project and its commissioning results are chronologically described in this article.

43 PARTICLE ACCELERATORS↗

Advanced electric propulsion and space plasma contactor research

A theory of the plasma contacting process is described and experimental results obtained using three different hollow cathode-based plasma contactors are presented. The existence of a sheath across which the bulk of the voltage drop associated with the contacting process occurs is demonstrated. Test results are shown to agree with a model of a spherical, space-charge-limited double sheath. The concept of ignited mode contactor operation is discussed, which is shown to enhance contactor efficiency when it is collecting electrons. An investigation of the potentials in the plasma plumes downstream of contactors operating at typical conditions is presented. Results of tests performed on hollow cathodes operating at high interelectrode pressures (up to about 1000 Torr) on ammonia are presented and criteria that are necessary to ensure that the cathode will operate properly in this regime are presented. These results suggest that high pressure hollow cathode operation is difficult to achieve and that special care must be taken to assure that the electron emission region remains diffuse and attached to the low work function insert. Experiments conducted to verify results obtained previously using a ring cusp ion source equipped with a moveable anode are described and test results are reported. A theoretical study of hollow cathode operation at high electron emission currents is presented. Preliminary experiments using the constrained sheath optics concept to achieve ion extraction under conditions of high beam current density, low net accelerating voltage and well columniated beamlet formation are discussed.

Wilbur, Paul J.↗

Mechanical properties of ion-beam-textured surgical implant alloys

An electron-bombardment Hg ion thruster was used as an ion source to texture surfaces of materials used to make orthopedic and/or dental prostheses or implants. The materials textured include 316 stainless steel, titanium-6% aluminum, 4% vanadium, and cobalt-20% chromium, 15% tungsten. To determine the effect of ion texturing on the ultimate strength and yield strength, stainless steel and Co-Cr-W alloy samples were tensile tested to failure. Three types of samples of both materials were tested. One type was ion-textured (the process also heats each sample to 300 C), another type was simply heated to 300 C in an oven, and the third type was untreated. Stress-strain diagrams, 0.2% offset yield strength data, total elongation data, and area reduction data are presented. Fatigue specimens of ion textured and untextured 316 stainless steel and Ti-6% Al-4% V were tested. Included as an ion textured sample is a Ti-6% Al-4% V sample which was ion machined by means of Ni screen mask so as to produce an array of 140 mu m x 140 mu m x 60 mu m deep pits. Scanning electron microscopy was used to characterize the ion textured surfaces.

Weigand, A. J.↗

Energetic ion phase space densities in Neptune's magnetosphere

Ion phase densities of Neptune are presently ascertained at the first and second adiabatic invariants of charged-particle motion on the basis of an analysis of Voyager 2 measurements. The profiles thus obtained are interpreted as indicative of generally inward radial diffusion, with an energetic ion source near L = 10. Excellent agreement is obtained between inbound and outbound phase-space density profiles at the values of the invariants; this suggests approximately axisymmetric, quasi-stationary radiation belts. The inward diffusing power carried by energetic ions appears adequate for powering Neptune's aurora, if enough of the ions are lost to the Neptune atmosphere.

Cheng, Andrew F.↗

Ion beam technology applications study

Specific perceptions and possible ion beam technology applications were obtained as a result of a literature search and contact interviews with various institutions and individuals which took place over a 5-month period. The use of broad beam electron bombardment ion sources is assessed for materials deposition, removal, and alteration. Special techniques examined include: (1) cleaning, cutting, and texturing for surface treatment; (2) crosslinking of polymers, stress relief in deposited layers, and the creation of defect states in crystalline material by ion impact; and (3) ion implantation during epitaxial growth and the deposition of neutral materials sputtered by the ion beam. The aspects, advantages, and disadvantages of ion beam technology and the competitive role of alternative technologies are discussed.

Sellen, J. M., Jr.↗

Ion mobility spectrometry of hydrazine, monomethylhydrazine, and ammonia in air with 5-nonanone reagent gas

Hydrazine (HZ) and monomethylhydrazine (MMH) in air were monitored continuously using a hand-held ion mobility spectrometer equipped with membrane inlet, 63Ni ion source, acetone reagent gas, and ambient temperature drift tube. Response characteristics included detection limit, 6 ppb; linear range, 10-600 ppb; saturated response, >2 ppm; and stable response after 15-30 min. Ammonia interfered in hydrazines detection through a product ion with the same drift time as that for MMH and HZ. Acetone reagent gas was replaced with 5-nonanone to alter drift times of product ions and separate ammonia from MMH and HZ. Patterns in mobility spectra, ion identifications from mass spectra, and fragmentation cross-sections from collisional-induced dissociations suggest that drift times are governed by ion-cluster equilibria in the drift region of the mobility spectrometer. Practical aspects including calibration, stability, and reproducibility are reported from the use of a hand-held mobility spectrometer on the space shuttle Atlantis during mission STS-37.

Flight Experiment↗

Making AlN(x) Tunnel Barriers Using a Low-Energy Nitrogen-Ion Beam

A technique based on accelerating positive nitrogen ions onto an aluminum layer has been demonstrated to be effective in forming thin (<2 nm thick) layers of aluminum nitride (AlN(x)) for use as tunnel barriers in Nb/Al-AlN(x)/Nb superconductor/insulator/ superconductor (SIS) Josephson junctions. AlN(x) is the present material of choice for tunnel barriers because, to a degree greater than that of any other suitable material, it offers the required combination of low leakage current at high current density and greater thermal stability. While ultra-thin AlN films with good thickness and stoichiometry control are easily formed using techniques such as reactive molecular beam epitaxy and chemical vapor deposition, growth temperatures of 900 C are necessary for the dissociative adsorption of nitrogen from either nitrogen (N2) or ammonia (NH3). These growth temperatures are prohibitively high for the formation of tunnel barriers on Nb films because interfacial reactions at temperatures as low as 200 to 300 C degrade device properties. Heretofore, deposition by reactive sputtering and nitridation of thin Al layers with DC and RF nitrogen plasmas have been successfully used to form AlN barriers in SIS junctions. However, precise control over critical current density Jc has proven to be a challenge, as is attaining adequate process reproducibility from system to system. The present ion-beam technique is an alternative to the plasma or reactive sputtering techniques as it provides a highly controlled arrival of reactive species, independent of the electrical conditions of the substrate or vacuum chamber. Independent and accurate control of parameters such as ion energy, flux, species, and direction promises more precise control of film characteristics such as stoichiometry and thickness than is the case with typical plasma processes. In particular, the background pressure during ion-beam nitride growth is 2 or 3 orders of magnitude lower, minimizing the formation of compounds with contaminants, which is critical in devices the performance of which is dictated by interfacial characteristics. In addition, the flux of incoming species can be measured in situ using ion probes so that the dose can be controlled accurately. The apparatus used in the present ion-beam technique includes a vacuum chamber containing a commercial collimated- ion-beam source, a supply of nitrogen and argon, and an ion probe for measuring the ion dose. Either argon or nitrogen can be used as the feed gases for the ion source, depending on whether cleaning of the substrate or growth of the nitride, respectively, is desired. Once the Nb base electrode and Al proximity layer have been deposited, the N2 gas line to the ion beam is vented and purged, and the ion-source is turned on until a stable discharge is obtained. The substrate is moved over the ion-beam source to expose the Al surface layer to the ion beam (see figure) for a specified duration for the formation of the nitride tunnel barrier. Next, the Nb counter-electrode layer is deposited on the nitride surface layer. The Nb/Al- AlN(x)/Nb-trilayer-covered substrate is then patterned into individual devices by use of conventional integrated-circuit processing techniques.

Kaul, Anupama↗

Measurement of Metastable Lifetimes of Highly-Charged Ions

The present work is part of a series of measurements of metastable lifetimes of highly-charged ions (HCIs) which contribute to optical absorption, emission and energy balance in the Interstellar Medium (ISM), stellar atmospheres, etc. Measurements were carried out using the 14-GHz electron cyclotron resonance ion source (ECRIS) at the JPL HCI facility. The ECR provides useful currents of charge states such as C(sup(1-6)+), Mg(sup(1-6)+) and Fe(sup(1-17)+). In this work the HCI beam is focused into a Kingdon electrostatic ion trap for measuring lifetimes via optical decays.

Smith, Steven J.↗

Mass Spectrometer Containing Multiple Fixed Collectors

A miniature mass spectrometer that incorporates features not typically found in prior mass spectrometers is undergoing development. This mass spectrometer is designed to simultaneously measure the relative concentrations of five gases (H2, He, N2, O2, and Ar) in air, over the relative-concentration range from 10(exp -6) to 1, during a sampling time as short as 1 second. It is intended to serve as a prototype of a product line of easy-to-use, portable, lightweight, highspeed, relatively inexpensive instruments for measuring concentrations of multiple chemical species in such diverse applications as detecting explosive or toxic chemicals in air, monitoring and controlling industrial processes, measuring concentrations of deliberately introduced isotopes in medical and biological investigations, and general environmental monitoring. The heart of this mass spectrometer is an integral combination of a circular cycloidal mass analyzer, multiple fixed ion collectors, and two mass-selective ion sources. By circular cycloidal mass analyzer is meant an analyzer that includes (1) two concentric circular cylindrical electrodes for applying a radial electric field and (2) a magnet arranged to impose a magnetic flux aligned predominantly along the cylindrical axis, so that ions, once accelerated into the annulus between the electrodes, move along circular cycloidal trajectories. As in other mass analyzers, trajectory of each ion is determined by its mass-to-charge ratio, and so ions of different species can be collected simultaneously by collectors (Faraday cups) at different locations intersected by the corresponding trajectories (see figure). Unlike in other mass analyzers, the installation of additional collectors to detect additional species does not necessitate increasing the overall size of the analyzer assembly.

Moskala, Robert↗

Cross-sections for 43 Sc, 44 m Sc, and 44 g Sc from two heavy ion reactions

Two different heavy ion reactions were used to produce 43 Sc (t$_{\frac12}$ = 3.891 h), 44g Sc (t$_{\frac12}$ = 4.042 h), and 44m Sc (t$_{\frac12}$ = 58.61 h) among other stable or long-lived chemically separable products. Production cross sections for 19 F + 27 Al and the reverse kinematic reaction 35 Cl + nat B were measured using an MC-SNICS ion source and the Notre Dame FN Tandem Accelerator. 19 F beams from 35 to 60 MeV were produced with beam currents between 40–80 pnA and 35 Cl beams were produced at six entrance energies with comparable beam currents. This work reports nuclear reaction cross sections 27 Al ( 19 F, x) 43 Sc, 27 Al ( 19 F, pn) 44g Sc, and 27 Al ( 19 F, pn) 44m Sc at six energies between 35 and 60 MeV lab energy. Cross sections within the same energy range were measured for 27 Al ( 19 F, 3pn) 42 K and 27 Al ( 19 F, 3p) 43 K. Comparative measurements were performed for the same compound nucleus produced from nat B( 35 Cl, x) 43 Sc, nat B( 35 Cl, pn) 44g Sc, and nat B( 35 Cl, pn) 44m Sc. The measured thin target cross sections show an overestimation by several statistical models for the scandium radioisotopes. This is corroborated by the measured thick target production rates for both entrance channels. This may be due to angular momentum effects of a heavy ion entrance channel compared to light-ion production, but additional work is required to understand this discrepancy. Finally, these measurements demonstrate that the medically useful 43 Sc, 44g Sc, and 44m Sc radioisotopes can be free of the long-lived contaminant 46 Sc without the use of enriched targets, using heavy ion beams and robust target materials.

07 ISOTOPE AND RADIATION SOURCES↗

Emission current control system for multiple hollow cathode devices

An emission current control system for balancing the individual emission currents from an array of hollow cathodes has current sensors for determining the current drawn by each cathode from a power supply. Each current sensor has an output signal which has a magnitude proportional to the current. The current sensor output signals are averaged, the average value so obtained being applied to a respective controller for controlling the flow of an ion source material through each cathode. Also applied to each controller are the respective sensor output signals for each cathode and a common reference signal. The flow of source material through each hollow cathode is thereby made proportional to the current drawn by that cathode, the average current drawn by all of the cathodes, and the reference signal. Thus, the emission current of each cathode is controlled such that each is made substantially equal to the emission current of each of the other cathodes. When utilized as a component of a multiple hollow cathode ion propulsion motor, the emission current control system of the invention provides for balancing the thrust of the motor about the thrust axis and also for preventing premature failure of a hollow cathode source due to operation above a maximum rated emission current.

Beattie, John R.↗

Optical Scattering and Microstructure of Ion Beam Deposited Metal Coatings

Thin films of gold and platinum have been deposited onto super-polished fused silica substrates using thermal evaporation, ion assisted deposition (IAD), sputtering and ion assisted sputtering. The influence of ion beam flux, coating material and deposition rate on the films microroughness have been investigated. Coatings of gold and platinum have been bombarded with low energy (10-20 eV) Ar ions from an electron cyclotron resonance (ECR) ion source during deposition. Short range surface microroughness of coated surfaces has been examined using scanning tunneling microscopy (STM) and atomic force microscopy (AFM), while long range surface microroughness has been characterized using an angle resolved optical scatterometer. Results indicate that bombardment with low energy ions causes significant reduction in microroughness of metal coatings.

metal↗

Computer simulation of current collection in a plasma environment

The pattern of current collection by a biased strip of stainless steel placed in the plasma environment produced by a 30 cm Kaufman ion thruster is studied. Two positions of the collector relative to the ion source were used. Edge on, in which case currents were measured on both sides of the collector, and face on, in which case currents were again measured on both sides of the collector. In the latter case, the surface of the collector that faces the ion thruster is referred to as the front face, the other side as the back face. A qualitative summary of the experimental results is presented.

Zei, D.↗