Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installation tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Carbon Absorber Retrofit Equipment (CARE)

During Project DE-FE0007528, CARE (Carbon Absorber Retrofit Equipment), Neumann Systems Group (NSG) designed, installed and tested a 0.5MW NeuStream® carbon dioxide (CO 2 ) capture system using the patented NeuStream® absorber equipment and concentrated (6 molal) piperazine (PZ) as the solvent at Colorado Springs Utilities’ (CSU’s) Martin Drake pulverized coal (PC) power plant. The 36 month project included design, build and test phases. The 0.5MW NeuStream® CO 2 capture system was successfully tested on flue gas from both coal and natural gas combustion sources and was shown to meet project objectives. Ninety percent CO 2 removal was achieved with greater than 95% CO 2 product purity. The absorbers tested support a 90% reduction in absorber volume compared to packed towers and with an absorber parasitic power of less than 1% when configured for operation with a 550MW coal plant. The preliminary techno-economic analysis (TEA) performed by the Energy and Environmental Research Center (EERC) predicted an over-the-fence cost of $25.73/tonne of CO 2 captured from a sub-critical PC plant.

01 COAL, LIGNITE, AND PEAT↗

Release Notes for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015-2016, Whisper was updated to version 1.1 [9] and is to be included with the upcoming release of MCNP6.2. This document describes the Whisper-1.1 package that will be included with the MCNP6.2 release during 2017. Specific details are provided on the computer systems supported, the software quality assurance (SQA) procedures, installation, and testing. This document does not address other important topics, such as the importance of sensitivity-uncertainty (SU) methods to NCS validation, the theory underlying SU methodology, tutorials on the usage of MCNP-Whisper, practical approaches to using SU methodology to support and extend traditional validation, etc. There are over 50 documents included with Whisper-1.1 and available in the MCNP Reference Collection on the MCNP website (mcnp.lanl.gov) that address all of those topics and more. In this document, however, a complete bibliography of relevant MCNP-Whisper references is provided.

97 MATHEMATICS AND COMPUTING↗

Implementation of Software Tools for Hybrid Control Rooms in the Human Systems Simulation Laboratory

The Institute for Energy Technology (IFE) and Idaho National Laboratory have designed, implemented, tested and installed a functioning prototype of a set of large screen overview and procedure support displays for the Generic Pressurized Water Reactor (GPWR) simulator in the U.S. Department of Energy’s Human Systems Simulation Laboratory. The overview display is based on IFE’s extensive experiences with large screen overview displays in the Halden Man-Machine Laboratory (HAMMLAB), and presents the main control room indicators on a combined three-screen display. The procedure support displays are designed and implemented to provide a compact but still comprehensive overview of the relevant process measurements and indicators to support operators' good situational awareness during the performance of various types of procedures and plant conditions.

97 MATHEMATICS AND COMPUTING↗

Large Pilot CAER Heat Integrated Post-combustion CO 2 Capture Technology for Reducing the Cost of Electricity

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0026497. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UKy-CAER) (Recipient) has developed an advanced, versatile, 10 MWe post-combustion CO 2 capture system (CCS) for a coal-fired power plant, Louisville Gas and Electric Company’s Trimble County Generating Station, using a heat integrated process combined with two-stage stripping and any advanced solvent to enhance the CO 2 absorber performance. The proposed project (Phase 1 and 2) will involve the design, fabrication, installation and testing of a large pilot scale facility that will demonstrate the UKy-CAER innovative carbon capture system integrated with an operating supercritical power plant. Specifically during Phase 1, the Recipient has provided all necessary documentation to support its Phase 2 down-selection including: the Project Narrative, the updated Project Management Plan (PMP), the preliminary engineering design, the Technical and Economic Analysis report (TEA) (including the Case 12 – Major Equipment List and submitted as a Topical Report), a Phase 1 Technology Gap Analysis (TGA), an Environmental Health and Safety (EH&S) Assessment on the 10 MWe unit, and updated Phase 2 cost estimates (including the detailed design, procurement, construction, operation, and decommissioning costs) with a budget justification. Furthermore, the Recipient has proposed a combined modular and freestanding column configuration with an advanced absorber gas/liquid distribution system, an advanced solvent, with the integration of discrete packing, a smart cross-over heat exchanger, and a load and ambient condition following control strategy, all to address ten of 12 technology gaps identified during the Phase I work. If successful, the proposed heat integrated post-combustion CCS will pave the way to achieve the United States Department of Energy National Energy Technology Laboratory (U.S. DOE NETL) CO 2 capture performance and cost target, as indicated in the submitted TEA and summarized in this report.

01 COAL, LIGNITE, AND PEAT↗

Final report of a scalable, automated, semipermanent seismic array (SASSA) method for detecting CO 2 extent during geologic CO 2 injection

The scalable, automated, semipermanent seismic array (SASSA) project led and managed by the Energy & Environmental Research Center (EERC) was designed as a 3-year proof-of-concept study to evaluate and demonstrate an innovative application of the seismic method. The concept was to use a sparse surface array of 96 nodal seismic sensors paired with a single, remotely operated active seismic source at a fixed location to monitor for CO 2 saturation changes in a subsurface reservoir by processing the data for time-lapse changes at individual, strategically chosen reservoir reflection points. The combination of autonomous equipment and modern processing algorithms was used to apply the seismic method in a manner different from the normal paradigm of collecting a spatially dense data set to produce an image. It was used instead to monitor individual, strategically chosen reservoir reflection points for detectable signal character changes that could be attributed to the passing of a CO 2 saturation front or, possibly, changes in reservoir pressure. Data collection occurred over the course of 1 year at an oil field undergoing CO 2 injection for enhanced oil recovery (EOR) and focused on four overlapping “five-spot” EOR injector–producer patterns. Selection, procurement, configuration, installation, and testing of project equipment and collection of five baseline data sets were completed in advance of CO 2 injection within the study area. Weekly remote data collection produced 41 incremental time-lapse records for each of the 96 nodes. Validation was provided by two methods: 1) a conventional 2-D seismic line acquired through the center of the study area before injection started and again after the project ended and processed in a time-lapse manner and 2) by CO 2 saturation maps created from reservoir simulations based on injection and production history matching. Interpreted results were encouraging but mixed, with indications of changes likely due to the presence of CO 2 on some node reflection points where and when effects would be expected and noneffects where no CO 2 was expected, while results at some locations where simulation outputs suggested CO 2 should be present were ambiguous. Acquisition noise impacted interpretation of data at several locations. Many lessons learned were generated by the study to inform and improve results on a follow-up study. The ultimate aim of the project was to evaluate whether deployment of a SASSA technology can provide a useful and cost-effective monitoring solution for future CO 2 injection projects. The answer appears to be affirmative, with the expectation that lessons learned applied to future iterations, together with technology advances, will likely result in significant improvements.

58 GEOSCIENCES↗

The new Pulse Dilation-PMT and high bandwidth gamma reaction history at NIF

This report outlines the details of how Pulse Dilation - PMT performs high bandwidth gamma reaction history measurements. The testing and installation of the Pulse Dilation - PMT is discussed, along methods to improve the understanding and data quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metal Bellows Valve Reliability Testing

Swagelok B ® series metal bellows-sealed valves were tested for their cycle performance longevity to evaluate their use in tritium service. The valves selected differed in the size of their pneumatic actuator and the stem tip material. Valves tested had one of three actuator sizes (1C, 3C, or 5C) and one of two stem tip materials: a cobalt-based metal, Stellite™, and a polyimide material, Vespel ® . An automated valve manifold was constructed, allowing for the simultaneous cycling of a total of 10 valves. Automation controls allowed for user inputs, controlling the number of valve cycles per test and the number of tests per experiment. Valves installed on the valve testing manifold to be cycled following a valve frequency test plan. After a defined number cycles, the valves would undergo leak testing using an inline leak detector. The inline helium leak detector provided qualitative detection of any failing or failed valves. If a valve had failed, a leak rate greater than at 1.0 x 10 -7 std cc He/sec, the valve would be removed from the manifold and quantitative leak rate measurements made. After specific cycling milestones were reached, quantitative valve leak rate measurements were performed to assess the adequacy of the qualitative measurement method. Valve evaluation began with initial leak tests: valve inlet/outlet seat rates and total body leak rate. The as received 1C valves, with PTFE stem tips, passed initial leak tests; however, stem tips replacements with either metal or polyimide stem tips essentially created valves which failed subsequent leak tests and were not subject to valve cycling. The 3C actuated valves had been cycled 150,000 times, resulting in 60% of the Stellite™ and Vespel ® tipped valves still passing the leak rate criteria. Failure analysis on the other 40% has yet to be conducted. Eight of the 5C valves had reached 150,000 cycles with 80% of the valves passing the leak rate criteria: two Vespel ® tipped 5C valves failed leak rate testing after 120,000 cycles.

36 MATERIALS SCIENCE↗

Advanced In-situ Diagnostics for Multicomponent Gas Analysis and Material Aging

Current methods of detecting material aging rely heavily on accelerated aging studies expensive, bulky, and resource-hungry diagnostics. We are developing compact gas analysis methods based on sensor platforms such as quartz crystal microbalances (QCM), using nanoporous metals and Metal-Organic Frameworks (MOFs), which enhance sensitivity and impart selectivity to analytes. Targeted analytes are O2 and other volatile analytes. In FY16 we installed and tested a new QCM system coupled to a commercial gas mixing system. This instrumentation provides a new multi-use capability that: 1) allows evaluation of detection of novel materials to enable selective detection of volatile species relevant to Enhanced Surveillance; 2) accelerates development of new thin film deposition methods for depositing these materials on sensing devices; and 3) enables in-situ monitoring, with sub-monolayer sensitivity, of the interaction of volatile species with material surfaces subject to aging or corrosion.

36 MATERIALS SCIENCE↗

Guralp Affinity Evaluation for SNL Infrasound Testbed

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, self-noise, dynamic range, system noise, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization. Moreover, it also provides 16 single-ended, 24 bit resolution, low sample rate auxiliary channels. The Affinity digitizer is undergoing these tests prior to installation in the FACT site infrasound test bed.

47 OTHER INSTRUMENTATION↗

Film Growth Dynamics During Pulsed Sputter Deposition (LDRD Final Report)

Novel materials synthesis and development using physical vapor deposition require our fundamental understanding of plasma conditions and film growth dynamics. A central theme is to control materials microstructure. Over the last few decades, the difficulty of thick heavy metal coatings has been one of the major bottlenecks limiting our studies of the important family of inertial-confinement-fusion (ICF) designs with colliding-shell targets. Our previous attempts to fabricate such coatings by conventional DC magnetron sputtering (DCMS) has had limited success due to the inherent complexity and our limited understanding of the deposition process. In this project, we have investigated the physics of a novel and promising pulsed sputter deposition process. We expanded the scientific foundation of sputter deposition processes through a combination of well-posed experiments and state-of-the-art characterizations. The following important scientific milestones have been achieved: (1) Successfully installed and tested a high-power impulse magnetron sputtering (HiPIMS) system; (2) Deployed a novel set of in-situ diagnostics during pulsed deposition, including a multibeam optical stress sensor (MOSS) system for real-time stress measurement, and Langmuir probe for the measurements of plasma physical properties. This allows us to monitor dynamically plasma conditions, ion flux and energy distributions, and film stress; (3) Investigated and obtained a fundamental understanding of HIPIMS on microstructure and stress control; (4) Successfully synthesized and demonstrated record-breaking strength nanocrystalline-nanotwinned (nnt) metals; (5) Successfully obtained high-quality, leak-proof Cr metal shells via HiPIMS method. The outcomes of this project could have transformational scientific and programmatic impacts, enabling novel materials synthesis and an experimental campaign with colliding shell target designs. The basic understanding of the deposition process has important implications to a broad range of industrial applications.

36 MATERIALS SCIENCE↗

Evaluation of Field-Mapping Data for the MI-Tech MI-506CE-1 Compact-Range Reflector in the Sandia National Laboratories' Facility for Antenna and Radar-cross-section Measurements (FARM)

The compact range, located at the Sandia National Laboratories Facility for Antenna and Radar-cross-section Measurements (FARM), has been upgraded by the addition of a new, larger reflector. The new reflector, an MI Technologies model MI-506CE-1, was installed and tested during August through October of 2013. Extensive field mapping was performed by MI Tech personnel, and that data is presented and examined here. Statistics describing the field quality are provided for the nominal test zone, as well as several reduced-size test zones. Spatial-frequency analysis has been applied to the data, and this process allows a determination of amplitude and direction information associated with unwanted reflected and diffracted field components arriving in the test zone.

42 ENGINEERING↗

Historical Context and Perspective on Allowable Stresses and Design Parameters in ASME Section III, Division 5, Subsection HB, Subpart B

In the 1970s, the U.S. Nuclear Regulatory Commission (NRC) issued Regulatory Guide (RG) 1.87 (Rev 1, June 1975) to provide interim licensing guidelines to aid applicants in implementing the 10 CFR Part 50 requirements with respect to American Society of Mechanical Engineers (ASME) Boiler Pressure and Vessel Code (BPVC) Class 1 components operating at elevated temperatures for high-temperature gas-cooled reactors, liquid-metal fast-breeder reactors, and gas-cooled fast-breeder reactors. RG 1.87 referenced ASME Code Case 1592 for materials and design and Code Cases 1593, 1594, 1595, and 1596 for fabrication and installation, examination, testing, and overpressure protection, respectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of the Redesigned Extended MITL for HERMES III

Modeling and simulation of the legacy HERMES III Magnetically Insulated Transmission Line (MITL) has been performed using EMPHASIS, an unstructured time-domain electromagnetic (UTDEM) particle-in-cell (PIC) simulation software. This design when used lost roughly half of its current before the pulse reached the load. The cause of the current loss in the MITL was found to be the vacuum impedance changes along the MITL. The MITL was then redesigned to maintain constant impedance and simulated in EMPHASIS once again. Following predicting simulation results, the new MITL was then built, installed, and tested, showing minimal current loss and good agreement with simulation and theoretical results, all of which are reported here. Additionally, an analysis of experimental voltage calculation techniques using cathode and anode currents is performed and compared to simulation results.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Generation-2 Dechlorination Apparatus for Treating Salt Wastes

This document satisfies the requirements for two milestones, i.e., M2FT-21PN030103021 and M3FT-21PN030103026, which are described in detail below. Also, details for the work package at the Pacific Northwest National Laboratory (PNNL) are provided below. The goal of this milestone was to demonstrate the generation-2 dechlorination apparatus (G2DA) for removing Cl from chloride-based electrochemical salt simulants. The two salts chosen for this initial study were KCl to simulate a component from the eutectic salt (LiCl is harder to detect with analytical instruments) and CsCl to simulate a fission product chloride that might be present in these types of waste streams. The overall scope of this work included receiving, installing, and testing the G2DA. This new system was designed to address several shortcomings identified with the generation-1 apparatus (G1DA), which are described in detail within this document. The G2DA was designed to address all of these shortcomings. The studies presented in here show that the G2DA worked as intended and will help provide scaled-up batches for additional testing at Argonne National Laboratory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MCNP ® Code Version 6.3.0 Build Guide

This is a build guide for the MCNP ® code, version 6.3.0, that expands upon the README.md included with the source code. It covers compilers, dependencies, building, testing, and installing the code in one of its supported configurations.

97 MATHEMATICS AND COMPUTING↗

Strain measurements of Nb₃Sn coils with optical fibers

The HL-LHC at CERN will be using new superconducting quadrupole magnets (MQXFA) made of Nb₃Sn that are in the process of being tested before installation in the LHC tunnel. MQXFA07 and MQXFA08 magnets failed because of high stress developed at the coil wedge/end spacer interface, where the Nb₃Sn coil, the stainless-steel end parts, and copper wedges exhibit different strain responses. Interrogating a cut piece of coil QXFP06 with optical fibers, we expect to get a better understanding of the stress response of the coil wedge/end spacer interface.

Nisa, Kuvvetn↗

Design and Prototyping of a Novel Toroid Magnet System for the MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment ?Measurement of Lepton-Lepton Electroweak Reaction? (MOLLER) requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for 3 years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. This system of magnets provides the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This paper presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet in the magnet (TM0) to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 have been fabricated by Everson-Tesla Incorporated, PA (USA). The manuscript presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

Kashy, David↗