Application of Constellation's best estimate alternate source term methodology
Safety analyses for a nuclear power plants need to consider postulated accidents that results in a risk of accidental release of radiation. The regulations require plant specific safety analysis reports to include an evaluation of the requirements of 10CFR50.67. Such a safety analysis report mandates limits such that calculated radiological consequences at certain locations do not exceed established limits in 10CFR50.67 following a postulated release of radioactivity. Analyses should demonstrate, with reasonable assurance, that these prescribed limits are complied with. Conventional methodologies utilize conservative approaches to address lack of uncertainty quantification in the utilized approaches, methods, and/or inputs. These built-in excess conservatisms often result in with compounding effects and hence overly conservative results in the estimated radiological consequences, which leads to inaccurate margin evaluation for operation and accident mitigation. Therefore, evaluating accurate dose consequences is needed for both operational and safety reasons. This paper illustrates the use of the best estimate source term (BEAST) methodology to the case of the loss of coolant accident (LOCA) dose analysis.