Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A multicolor imaging pyrometer

A multicolor imaging pyrometer was designed for accurately and precisely measuring the temperature distribution histories of small moving samples. The device projects six different color images of the sample onto a single charge coupled device array that provides an RS-170 video signal to a computerized frame grabber. The computer automatically selects which one of the six images provides useful data, and converts that information to a temperature map. By measuring the temperature of molten aluminum heated in a kiln, a breadboard version of the device was shown to provide high accuracy in difficult measurement situations. It is expected that this pyrometer will ultimately find application in measuring the temperature of materials undergoing radiant heating in a microgravity acoustic levitation furnace.

Frish, Michael B.↗

Visualization of High Latitude Ion Upflow in Support of the Image Mission

The study of the magnetosphere is a 400 year old science that began with the publication by Gilbert, in 1600, of his hypotheses that the Earth was a giant magnet. Since then we have learned many things about the magnetosphere, particularly in the last 40 years of the space age, but we still have many unanswered questions. In spite of the many thousands of observations of this system we still lack a global understanding of how it works. This is due to its large size and tenuous nature that mean that any measurement made of the fields or particles involved only give one a knowledge of the local conditions at a given time. To gain a global perspective through such observations would require the simultaneous operation of thousands of satellites spread throughout the magnetospheric system in addition to observations made on the ground. Such a program would be impractical at least from financial considerations. What is needed for the advancement of magnetospheric physics is to develop the same capabilities that astrophysicists, solar physicists and meteorologists have been using for years --- the ability to stand back from the object under study and see it in its entirety. The challenge for doing this for the magnetosphere is that the particle densities are very low and the material is, for the most part, not luminous. In the last 25 years several ideas have been proposed that would allow at least the imaging of certain portions of the magnetosphere. These include imaging of the plasmasphere through the resonant scattering of solar 304 A from He+ ions, imaging of various hot plasma populations (i.e. the ring current, plasmasheet, upflowing ionospheric ions, etc.) from the neutral atoms that result when ions of these populations charge exchange with the hydrogen geocorona, and imaging the aurora at various wavelengths in the far ultraviolet. In addition, a novel technique for probing various boundaries in the magnetosphere by bouncing low frequency radio waves off of them has been extensively studied. Such a technique is analogous to the way the under water world can be probed with sonar. About five years ago NASA convened a science working group to study the possibility of flying a magnetospheric imaging mission. This resulted in a number of proposals for such a mission, one of which was selected to be the first MIDEX mission, to be launched in early 2000. The mission is called IMAGE (Imager for Magnetopause to Aurora Global Exploration) and its P.I. is J. Burch at SwRI. The IMAGE spacecraft will carry imagers to view the plasmasphere, aurora, ring current, inner plasmasheet, and upflowing ionospheric ions as well as a radio sounder to probe the location, shape and dynamics of the magnetopause, plasmapause, etc. Between its selection last April and the non advocacy mission review, which takes place next spring, the IMAGE teams needs to further refine the design of the mission and its instruments. The theory and modeling (T&M) subgroup of this team has the task of demonstrating what kind of images the instruments on IMAGE will see as well as showing that useful scientific information can be extracted from such images. As a central element to the efforts of the T&M subgroup we have decided to simulate and create synthetic images for the magnetic cloud event of October, 1995. In this event a large cloud, with high plasma densities and strong magnetic fields, ejected from the sun collided with the earth's magnetosphere triggering a three day period of intense magnetic storms and substorms. This event was observed from a number of different spacecraft and on the ground so we have a good data set to work with. In our work we will place the IMAGE spacecraft in the magnetosphere on its proposed orbit, with its proposed instruments, to see what it would see had it been there. Existing models of the plasmasphere, ring current and magnetopause will be run for this event to give the structures for the imaging instruments. There are several models which are lacking and which need to be developed. These include a model for the cusp, the inner plasmasheet and the upflowing ions. My task this summer was to develop the upflowing ion model and use it to create synthetic images.

Wilson, Gordon R.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arc minute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arcminute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Flame Imaging System

A system for imaging a flame and the background scene is discussed. The flame imaging system consists of two charge-coupled-device (CCD) cameras. One camera uses a 800 nm long pass filter which during overcast conditions blocks sufficient background light so the hydrogen flame is brighter than the background light, and the second CCD camera uses a 1100 nm long pass filter, which blocks the solar background in full sunshine conditions such that the hydrogen flame is brighter than the solar background. Two electronic viewfinders convert the signal from the cameras into a visible image. The operator can select the appropriate filtered camera to use depending on the current light conditions. In addition, a narrow band pass filtered InGaAs sensor at 1360 nm triggers an audible alarm and a flashing LED if the sensor detects a flame, providing additional flame detection so the operator does not overlook a small flame.

Barnes, Heidi L.↗

Active pixel sensor having intra-pixel charge transfer with analog-to-digital converter

An imaging device formed as a monolithic complementary metal oxide semiconductor Integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate, a readout circuit including at least an output field effect transistor formed in the substrate, and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node connected to the output transistor and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node and an analog-to-digital converter formed in the substrate connected to the output of the readout circuit.

Fossum, Eric R.↗

Active pixel sensor having intra-pixel charge transfer with analog-to-digital converter

An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate, a readout circuit including at least an output field effect transistor formed in the substrate, and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node connected to the output transistor and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node and an analog-to-digital converter formed in the substrate connected to the output of the readout circuit.

Fossum, Eric R.↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

Delta-doped CCD's as low-energy particle detectors and imagers

The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to detect very low-energy particles that penetrate less than 1.0 nm into the CCD, including electrons having energies less than 1000 eV and protons having energies less than 10 keV.

Nikzad, Shouleh↗

Application of a silicon photodiode array for solar edge tracking in the Halogen Occultation Experiment

The optical and electronic design of the Halogen Occultation Experiment (HALOE) elevation sunsensor is described. This system uses a Galilean telescope to form a solar image on a linear silicon photodiode array. The array is a self-scanned, monolithic charge coupled device. The addresses of both solar edges imaged on the array are used by the control/pointing system to scan the HALOE science instantaneous-field-of-view (IFOV) across the vertical solar diameter during instrument calibration, and then maintain the science IFOV four arcmin below the top edge during the science data occultation event. Vertical resolution of 16 arcsec and a radiometric dynamic range of 100 are achieved at the 0.7 micrometer operating wavelength. The design provides for loss of individual photodiode elements without loss of angular tracking capability. The HALOE instrument is a gas correlation radiometer that is now being developed by NASA Langley Research Center for the Upper Atmospheric Research Satellite.

Mauldin, L. E., III↗

Far Ultraviolet Imaging from the Image Spacecraft: Wideband FUV Imaging - 2

The Far Ultraviolet Wideband Imaging Camera (WIC) complements the magnetospheric images taken by the IMAGE satellite instruments with simultaneous global maps of the terrestrial aurora. Thus, a primary requirement of WIC is to image the total intensity of the aurora in wavelength regions most representative of the aurora] source and least contaminated by dayglow, have sufficient field of view to cover the entire polar region from spacecraft apogee and have resolution that is Sufficient to resolve auroras on a scale of 1 to 2 latitude degrees, The instrument is sensitive in the spectral region from 140- 190 nm. The WIC is mounted on the rotating, IMAGE spacecraft viewing radially outward and has a field of view of 17 deg in the direction parallel to the spacecraft spin axis. Its field of view is 30 deg in the direction perpendicular to the spin axis, although only a 17 deg x 17 deg image of the Earth is recorded. The optics was an all-reflective, inverted Cassegrain Burch camera using concentric optics with a small convex primary and a large concave secondary mirror. The mirrors were coated by a special multi-layer coating, which has low reflectivity in the visible and near UV region, The detector consists of a MCP-Intensified CCD. The MCP is curved to accommodate the focal surface of the concentric optics. Tile phosphor of the image intensifier is deposited on a concave fiberoptic window, which is then Coupled to the CCD with a fiberoptic taper. The camera head operates in a fast frame transfer mode with the CCD being read approximately 30 full frames (512 by 256 pixel) per second with an exposure time of 0.033 s. The image motion (file to the satellite spin is minimal during such a short exposure. Each image is electronically distortion corrected using the look up table scheme. An offset is added to each memory address that is proportional to the image shift due to satellite rotation, and the charge signal is digitally summed in memory. On orbit, approximately 300 frames will be added to produce one WIC image in memory. The advantage of the electronic motion compensation and distortion correction is that it is extremely flexible, permitting several kinds of corrections including motions parallel and perpendicular to the predicted axis of rotation. File instrument was calibrated by applying ultraviolet light through a vacuum monochromator and measuring the absolute responsivity of the instrument. To obtain the data for the distortion look up table the camera was turned through various angles and the input angles corresponding to a pixel matrix were recorded. It was found that the spectral response peaked at 150 nm and fell off in either direction. The equivalent aperture of the camera, including mirror reflectivities and effective photocathode quantum efficiency, is about 0.04 sq cm. Thus, a 100 Rayleigh LBH aurora is expected to produce 23 equivalent counts per pixel per 10 s exposure at the peak of instrument response.

Mende, S. B.↗

Mapping charge excitations in generalized Wigner crystals

Transition metal dichalcogenide-based moiré superlattices exhibit strong electron-electron correlations, thus giving rise to strongly correlated quantum phenomena such as generalized Wigner crystal states. Evidence of Wigner crystals in transition metal dichalcogenide moire superlattices has been widely reported from various optical spectroscopy and electrical conductivity measurements, while their microscopic nature has been limited to the basic lattice structure. Theoretical studies predict that unusual quasiparticle excitations across the correlated gap between upper and lower Hubbard bands can arise due to long-range Coulomb interactions in generalized Wigner crystal states. However, the microscopic proof of such quasiparticle excitations is challenging because of the low excitation energy of the Wigner crystal. Here, in this study, we describe a scanning single-electron charging spectroscopy technique with nanometre spatial resolution and single-electron charge resolution that enables us to directly image electron and hole wavefunctions and to determine the thermodynamic gap of generalized Wigner crystal states in twisted WS 2 moiré heterostructures. High-resolution scanning single-electron charging spectroscopy combines scanning tunnelling microscopy with a monolayer graphene sensing layer, thus enabling the generation of individual electron and hole quasiparticles in generalized Wigner crystals. We show that electron and hole quasiparticles have complementary wavefunction distributions and that thermodynamic gaps of ~50 meV exist for the 1/3 and 2/3 generalized Wigner crystal states in twisted WS 2 .

36 MATERIALS SCIENCE↗

NASA Tech Briefs, March 2009

Topics covered include: Improved Instrument for Detecting Water and Ice in Soil; Real-Time Detection of Dust Devils from Pressure Readings; Determining Surface Roughness in Urban Areas Using Lidar Data; DSN Data Visualization Suite; Hamming and Accumulator Codes Concatenated with MPSK or QAM; Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS; Biasable Subharmonic Membrane Mixer for 520 to 600 GHz; Hardware Implementation of Serially Concatenated PPM Decoder; Symbolic Processing Combined with Model-Based Reasoning; Presentation Extensions of the SOAP; Spreadsheets for Analyzing and Optimizing Space Missions; Processing Ocean Images to Detect Large Drift Nets; Alternative Packaging for Back-Illuminated Imagers; Diamond Machining of an Off-Axis Biconic Aspherical Mirror; Laser Ablation Increases PEM/Catalyst Interfacial Area; Damage Detection and Self-Repair in Inflatable/Deployable Structures; Polyimide/Glass Composite High-Temperature Insulation; Nanocomposite Strain Gauges Having Small TCRs; Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling; Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps; Continuous-Flow System Produces Medical-Grade Water; Discrimination of Spore-Forming Bacilli Using spoIVA; nBn Infrared Detector Containing Graded Absorption Layer; Atomic References for Measuring Small Accelerations; Ultra-Broad-Band Optical Parametric Amplifier or Oscillator; Particle-Image Velocimeter Having Large Depth of Field; Enhancing SERS by Means of Supramolecular Charge Transfer; Improving 3D Wavelet-Based Compression of Hyperspectral Images; Improved Signal Chains for Readout of CMOS Imagers; SOI CMOS Imager with Suppression of Cross-Talk; Error-Rate Bounds for Coded PPM on a Poisson Channel; Biomorphic Multi-Agent Architecture for Persistent Computing; and Using Covariance Analysis to Assess Pointing Performance.

Source record↗

800 x 800 charge-coupled device /CCD/ camera for the Galileo Jupiter Orbiter mission

During January 1982 the NASA space transportation system will launch a Galileo spacecraft composed of an orbiting bus and an atmospheric entry probe to arrive at the planet Jupiter in July 1985. A prime element of the orbiter's scientific instrument payload will be a new generation slow-scan planetary imaging system based on a newly developed 800 x 800 charge-coupled device (CCD) image sensor. Following Jupiter orbit insertion, the single, narrow-angle, CCD camera, designated the Solid State Imaging (SSI) Subsystem, will operate for 20 months as the orbiter makes repeated encounters with Jupiter and its Galilean Satellites. During this period the SSI will acquire 40,000 images of Jupiter's atmosphere and the surfaces of the Galilean Satellites. This paper describes the SSI, its operational modes, and science objectives.

Clary, M. C.↗

Mars Science Laboratory Engineering Cameras

NASA's Mars Science Laboratory (MSL) Rover, which launched to Mars in 2011, is equipped with a set of 12 engineering cameras. These cameras are build-to-print copies of the Mars Exploration Rover (MER) cameras, which were sent to Mars in 2003. The engineering cameras weigh less than 300 grams each and use less than 3 W of power. Images returned from the engineering cameras are used to navigate the rover on the Martian surface, deploy the rover robotic arm, and ingest samples into the rover sample processing system. The navigation cameras (Navcams) are mounted to a pan/tilt mast and have a 45-degree square field of view (FOV) with a pixel scale of 0.82 mrad/pixel. The hazard avoidance cameras (Haz - cams) are body-mounted to the rover chassis in the front and rear of the vehicle and have a 124-degree square FOV with a pixel scale of 2.1 mrad/pixel. All of the cameras utilize a frame-transfer CCD (charge-coupled device) with a 1024x1024 imaging region and red/near IR bandpass filters centered at 650 nm. The MSL engineering cameras are grouped into two sets of six: one set of cameras is connected to rover computer A and the other set is connected to rover computer B. The MSL rover carries 8 Hazcams and 4 Navcams.

Maki, Justin N.↗

Anomalous Superfluid Density in a Disordered Charge-Density-Wave Material: Pd-Intercalated ErTe 3

We image local superfluid density in single crystals of Pd-intercalated ErTe 3 below the superconducting critical temperature T c , well below the onset temperature T CDW of (disordered) charge-density-wave order. We find no detectable inhomogeneities on micron scales. Furthermore, we observe a rapid increase of the superfluid density below T c , deviating from the behavior expected in a conventional Bardeen-Cooper-Schrieffer superconductor, and show that the temperature dependence is qualitatively consistent with a combination of quantum and thermal phase fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-Shot Spectrally Resolved UV Rayleigh Scattering Measurements in High Speed Flow

A single-shot UV molecular Rayleigh scattering technique to measure velocity in high speed flow is described. The beam from an injection-seeded, frequency quadrupled Nd:YAG laser (266 nm) is focused to a line in a free air jet with velocities up to Mach 1.3. Rayleigh scattered light is imaged through a planar mirror Fabry-Perot interferometer onto a Charged Coupled Device (CCD) array detector. Some laser light is also simultaneously imaged through the Fabry-Perot to provide a frequency reference. Two velocity measurements are obtained from each image. Multiple-pulse data are also given. The Rayleigh scattering velocity data show good agreement with velocities calculated from isentropic flow relations.

Seasholtz, Richard G.↗

Capacitance Transients, Photoconductive Decay, and Impedance Spectroscopy on 19% to 22% Efficient Silicon Solar Cells

High efficiency silicon solar cells are characterized using current-voltage curves, electroluminescence imaging, impedance spectroscopy, capacitance transients, microwave photoconductive decay, and time-resolved photoluminescence imaging. The sample set is composed of cells from different manufacturers and includes an n-type silicon heterojunction (SHJ), an n-type passivated emitter rear totally diffused (PERT), and five different p-type passivated emitter rear contact (PERC) cells. Carrier lifetimes, both photoconductivity and photoluminescence, are measured co-located with the light excitation pulse and within the cell but away from the light spot. Luminescence intensity and excess carrier lifetimes correlate to cell voltage. The capacitance transient time constants correlate to the capacitance values extracted from impedance spectroscopy.

capacitance↗