Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Requirements for Portable Instrument Suites during Human Scientific Exploration of Mars

Human explorers on the surface of Mars will have access to a far wider array of scientific tools than previous crewed planetary exploration missions, but not every tool will be compatible with the restrictions of this exploration. Spectrometers on flyby, orbital, and landed missions are currently used to determine the composition and mineralogy of geological materials of various types and sizes, from small fragments to celestial bodies in the solar system. Handheld spectrometers that are capable of in situ analyses are already used for geological exploration on Earth; however, their usefulness for human exploration missions and how data from multiple handheld instruments could be combined to enhance scientific return must be further evaluated. As part of the Biologic Analog Science Associated with Lava Terrains (BASALT) research project, we incorporated two handheld instruments, a visible-near infrared spectrometer and an X-Ray Fluorescence spectrometer, into simulated Mars exploration missions conducted on basaltic terrains in Idaho and Hawai'i. To understand the data quality provided by these handheld spectrometers, we evaluated their performance under varying conditions of measurement time, distance, angle, atmosphere, and sample matrix, and we compared data quality between handheld instruments and laboratory techniques. Here, we summarize these findings, provide guidelines and requirements on how to effectively incorporate these instruments into human exploration missions to Mars, and posit that future iterations of these instruments will be beneficial for enhancing science returned from human exploration missions.

Alexander Sehlke↗

Development of peptoid-based ligands for the removal of cadmium from biological media

Cadmium poisoning poses a serious health concern due to cadmium's increasing industrial use, yet there is currently no recommended treatment. The selective coordination of cadmium in a biological environment—i.e. in the presence of serum ions, small molecules, and proteins—is a difficult task. To address this challenge, a combinatorial library of peptoid-based ligands has been evaluated to identify structures that selectively bind to cadmium in human serum with minimal chelation of essential metal ions. Eighteen unique ligands were identified in this screening procedure, and the binding affinity of each was measured using metal titrations monitored by UV-vis spectroscopy. To evaluate the significance of each chelating moiety, sequence rearrangements and substitutions were examined. Analysis of a metal–ligand complex by NMR spectroscopy highlighted the importance of particular residues. Depletion experiments were performed in serum mimetics and human serum with exogenously added cadmium. These depletion experiments were used to compare and demonstrate the ability of these peptoids to remove cadmium from blood-like mixtures. In one of these depletion experiments, the peptoid sequence was able to deplete the cadmium to a level comparable to the reported acute toxicity limit. Evaluation of the metal selectivity in buffered solution and in human serum was performed to verify minimal off-target binding. These studies highlight a screening platform for the identification of metal–ligands that are capable of binding in a complex environment. They additionally demonstrate the potential utility of biologically-compatible ligands for the treatment of heavy metal poisoning.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spacecraft Cabin Ventilation Fan: Wake Measurements Results

Quiet, efficient fans with minimal vibrations are required for revitalization system fans used for human support system in long duration space exploration missions. A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed in NASA Glenn research center. Two copies of the fan assembly were fabricated and tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot-wire measurements of the fan wake. Hot-wire measurements were obtained by radially traversing a x-wire probe downstream of the rotor. This report documents the phase-locked wake velocity, flow angle and turbulence measurements from the hot-wire surveys as part of a series of reports.

Hotwire Measurement↗

Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review

Heating, ventilation and air-conditioning (HVAC) systems have been adopted to create comfortable, healthy and safe indoor environments. In the control loop, the technical feature of the human demand-oriented supply can help operate HVAC effectively. Among many technical options, real time monitoring based on feedback signals from end users has been frequently reported as a critical technology to confirm optimizing building performance. Recent studies have incorporated human thermal physiology signals and thermal comfort/discomfort status as real-time feedback signals. A series of human subject experiments used to be conducted by primarily adopting subjective questionnaire surveys in a lab-setting study, which is limited in the application for reality. With the help of advanced technologies, physiological signals have been detected, measured and processed by using multiple technical formats, such as wearable sensors. Nevertheless, they mostly require physical contacts with the skin surface in spite of the small physical dimension and compatibility with other wearable accessories, such as goggles, and intelligent bracelets. Most recently, a low cost small infrared camera has been adopted for monitoring human facial images, which could detect the facial skin temperature and blood perfusion in a contactless way. Also, according to latest pilot studies, a conventional digital camera can generate infrared images with the help of new methods, such as the Euler video magnification technology. Human thermal comfort/discomfort poses can also be detected by video methods without contacting human bodies and be analyzed by the skeleton keypoints model. Here, new sensing technologies were summarized, their cons and pros were discussed, and extended applications for the demand-oriented ventilation were also reviewed as potential development and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Victim Simulator for Victim Detection Radar

Testing of victim detection radars has traditionally used human subjects who volunteer to be buried in, or climb into a space within, a rubble pile. This is not only uncomfortable, but can be hazardous or impractical when typical disaster scenarios are considered, including fire, mud, or liquid waste. Human subjects are also inconsistent from day to day (i.e., they do not have the same radar properties), so quantitative performance testing is difficult. Finally, testing a multiple-victim scenario is difficult and expensive because of the need for multiple human subjects who must all be coordinated. The solution is an anthropomorphic dummy with dielectric properties that replicate those of a human, and that has motions comparable to human motions for breathing and heartbeat. Two airfilled bladders filled and drained by solenoid valves provide the underlying motion for vinyl bags filled with a dielectric gel with realistic properties. The entire assembly is contained within a neoprene wetsuit serving as a "skin." The solenoids are controlled by a microcontroller, which can generate a variety of heart and breathing patterns, as well as being reprogrammable for more complex activities. Previous electromagnetic simulators or RF phantoms have been oriented towards assessing RF safety, e.g., the measurement of specific absorption rate (SAR) from a cell phone signal, or to provide a calibration target for diagnostic techniques (e.g., MRI). They are optimized for precise dielectric performance, and are typically rigid and immovable. This device is movable and "positionable," and has motion that replicates the small-scale motion of humans. It is soft (much as human tissue is) and has programmable motions.

Lux, James P.↗

Individual Differences in Human Reliability Analysis

While human reliability analysis (HRA) methods include uncertainty in quantification, the nominal model of human error in HRA typically assumes that operator performance does not vary significantly when they are given the same initiating event, indicators, procedures, and training, and that any differences in operator performance are simply aleatory (i.e., random). While this assumption generally holds true when performing routine actions, variability in operator response has been observed in multiple studies, especially in complex situations that go beyond training and procedures. As such, complexity can lead to differences in operator performance (e.g., operator understanding and decision-making). Furthermore, psychological research has shown that there are a number of known antecedents (i.e., attributable causes) that consistently contribute to observable and systematically measurable (i.e., not random) differences in behavior. This paper reviews examples of individual differences taken from operational experience and the psychological literature. The impact of these differences in human behavior and their implications for HRA are then discussed. We propose that individual differences should not be treated as aleatory, but rather as epistemic. Ultimately, by understanding the sources of individual differences, it is possible to remove some epistemic uncertainty from analyses.

99 GENERAL AND MISCELLANEOUS↗

BLOOD-BASED MULTI-SCALE MODEL FOR CANCER RISK FROM GCR IN GENETICALLY DIVERSE POPULATIONS

OBJECTIVES AND METHODS This project addresses the challenge of understanding and predicting individual radiation sensitivity by integrating genetics, demographics and biomarker characteristics across species (mice and humans). We hypothesize that ex vivo DNA repair response to GCR components is a central determinant of cancer risk from space radiation and can serve as a biomarker of radiation risk in combination with genetics. Automated image quantification of 53BP1+ radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET in non-immortalized primary skin fibroblasts derived from 76 mice across 15 strains (5 inbred reference strains and 10 collaborative-cross strains) exposed to X rays (0.1, 1 and 4 Gy), 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100μm2), as well as in peripheral blood mononuclear cells (PBMCs) from 768 healthy donors (matched ethnicity, 50/50 male/female, 18-70 years old) exposed to gamma rays (0.1 and 1 Gy), 350 MeV/n 28Si, 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100μm2). QUANTIFICATION OF 53BP1+ FOCI IN VITRO AND ASSOCIATIONS TO IN VIVO RADIATION SUSCEPTIBILITY IN 15 MOUSE STRAINS We reported in vitro repair kinetic and repairable fractions of RIF for the 15 mouse strains and introduced a mathematical model for RIF as a function of time, dose and LET. We noted that the metabolic activity of cells modulates the RIF response, and we introduced the open access tool terRIFic (Tool for Enhanced Results of RIF In Cells, https://radbiolab.shinyapps.io/terrific/) to correct for such bias using confluence level. Notably, at 4h post-irradiation, RIF/Gy decreased with dose or LET: as the dose or LET increases, so does the proximity of DNA double-strand-breaks (DSB) and our data suggest that proximal DSBs are brought together inside isolated RIF for repair. The RIF/Gy trend was inverted at 24h, suggesting RIF with high DSB content are more difficult to repair. We showed that in vitro metrics correlate with in vivo measurements in the same 15 mouse strains, such as survival levels of immune cells or spontaneous cancer incidence, suggesting a relationship between the efficiency of DSB repair and cancer risk or radiation toxicity. In addition to the efficiency of repair and persistent RIF, the amount of spontaneous foci before irradiation was also found to be strain dependent. Finally, we performed genome-wide association study in the same 15 mouse strains using all RIF phenotypes measured in vitro, identifying genes of interest and validating RIF as an ideal biomarker for individual radiation sensitivity. BASELINE 53BP1+ FOCI PREDICTS INDIVIDUAL HUMAN RESPONSE TO GCR COMPONENTS Based on the analysis of radiation responses of 576 donor PBMCs (using quantification of 53BP1+ foci, oxidative stress and cell death), we observed a wide variability of subject- and LET-dependent radiation responses, with radiation-induced DNA repair foci increasing with LET, though oxidative stress being notably reduced by high-LET irradiation, potentially due to a switch between hydrogen peroxide and oxygen radical-based mechanisms. We identified a relationship between few spontaneous DNA foci at baseline and increased DNA repair after irradiation, accompanied by an alteration in immunoregulatory cytokine secretion, which might be adapted as biomarkers to predict ionizing radiation sensitivity. Among demographic variables, only latent cytomegalovirus infection and age were predictive of high baseline foci formation. Finally, we have performed low-throughput whole genome sequencing of all samples and are currently in the process of identifying the genes and pathways associated with low and high-LET ionizing radiation sensitivity in humans.

53BP1↗

A signature dissimilarity measure for trabecular bone texture in knee radiographs

Purpose: The purpose of this study is to develop a dissimilarity measure for the classification of trabecular bone (TB) texture in knee radiographs. Problems associated with the traditional extraction and selection of texture features and with the invariance to imaging conditions such as image size, anisotropy, noise, blur, exposure, magnification, and projection angle were addressed. Methods: In the method developed, called a signature dissimilarity measure (SDM), a sum of earth mover's distances calculated for roughness and orientation signatures is used to quantify dissimilarities between textures. Scale-space theory was used to ensure scale and rotation invariance. The effects of image size, anisotropy, noise, and blur on the SDM developed were studied using computer generated fractal texture images. The invariance of the measure to image exposure, magnification, and projection angle was studied using x-ray images of human tibia head. For the studies, Mann-Whitney tests with significance level of 0.01 were used. A comparison study between the performances of a SDM based classification system and other two systems in the classification of Brodatz textures and the detection of knee osteoarthritis (OA) were conducted. The other systems are based on weighted neighbor distance using compound hierarchy of algorithms representing morphology (WND-CHARM) and local binary patterns (LBP). Results: Results obtained indicate that the SDM developed is invariant to image exposure (2.5-30 mA s), magnification (x1.00-x1.35), noise associated with film graininess and quantum mottle (<25%), blur generated by a sharp film screen, and image size (>64x64 pixels). However, the measure is sensitive to changes in projection angle (>5 deg.), image anisotropy (>30 deg.), and blur generated by a regular film screen. For the classification of Brodatz textures, the SDM based system produced comparable results to the LBP system. For the detection of knee OA, the SDM based system achieved 78.8% classification accuracy and outperformed the WND-CHARM system (64.2%). Conclusions: The SDM is well suited for the classification of TB texture images in knee OA detection and may be useful for the texture classification of medical images in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Changing Weight and Mass on Human Performance in a Lunar Prototype Spacesuit

Physical effort, compensation, and controllability in a spacesuit can be affected by suit mass and gravity level. Because of limitations in certain reduced-gravity simulators and the finite selection of lunar prototype suits, it is difficult to ascertain how a change in suit mass affects suited human performance. One method of simulating a change in mass is to vary the total gravity-adjusted weight (TGAW), which is defined as the sum of the suit mass and subject mass, multiplied by the gravity level. PURPOSE: To determine if two methods of changing TGAW during parabolic flight - changing suit mass or gravity level - affect subjective ratings of suited human performance equally. METHODS: A custom weight support structure was connected to a lunar prototype spacesuit, allowing the addition of mass to the suit while maintaining a near-constant center of mass. In the varied-weight (VW) series, suit mass (120 kg) was constant at 0.1 G, 0.17 G, and 0.3 G, yielding TGAWs of 196, 333, and 588 N, assuming an 80-kg subject. In the varied-mass (VM) series, gravity level was constant at 0.17 G and suit mass was 89, 120, and 181 kg, yielding TGAWs of 282, 333, and 435 N. The 333 N condition was common to both series. Direct comparison was not possible due to limited adjustability of suit mass and limited options for parabolic profiles. Five astronaut subjects (80.3 11.8 kg) completed 4 different tasks (walk, bag pickup, lunge, and shoveling) in all conditions and provided ratings of perceived exertion (RPE) and the gravity compensation and performance scale (GCPS) upon completion of each task. RESULTS: Where VM and VW series overlapped, RPE and GCPS trendlines were similar. Mean RPE and GCPS at 333 N was 8.4 and 3.7. Mean RPE and GCPS for VM was 7.8 and 3.8 for 282 N and 9.8 and 4.1 for 435 N. Extrapolation of the VM trend to match VW TGAWs 196 and 588 N predicts an RPE of 6.5 and 12.3 and GCPS of 4.4 and 5.9, whereas the measured VW values for RPE were 8.1 and 9.8 and GCPS were 4.4 and 3.7. CONCLUSION: Modeling a change in suit mass by altering weight alone may be an adequate simulation through a limited range when looking at gross metrics of subjective suited human performance. Whether altering weight alone will be sufficient for more precise metrics of human performance, and across a wider range of activities, still needs further study.

Norcross, Jason R.↗

Electron Irradiation of Conjunctival Lymphoma-Monte Carlo Simulation of the Minute Dose Distribution and Technique Optimization

Purpose: External beam radiotherapy is the only conservative curative approach for Stage I non-Hodgkin lymphomas of the conjunctiva. The target volume is geometrically complex because it includes the eyeball and lid conjunctiva. Furthermore, the target volume is adjacent to radiosensitive structures, including the lens, lacrimal glands, cornea, retina, and papilla. The radiotherapy planning and optimization requires accurate calculation of the dose in these anatomical structures that are much smaller than the structures traditionally considered in radiotherapy. Neither conventional treatment planning systems nor dosimetric measurements can reliably determine the dose distribution in these small irradiated volumes. Methods and Materials: The Monte Carlo simulations of a Varian Clinac 2100 C/D and human eye were performed using the PENELOPE and PENEASYLINAC codes. Dose distributions and dose volume histograms were calculated for the bulbar conjunctiva, cornea, lens, retina, papilla, lacrimal gland, and anterior and posterior hemispheres. Results: The simulated results allow choosing the most adequate treatment setup configuration, which is an electron beam energy of 6 MeV with additional bolus and collimation by a cerrobend block with a central cylindrical hole of 3.0 cm diameter and central cylindrical rod of 1.0 cm diameter. Conclusions: Monte Carlo simulation is a useful method to calculate the minute dose distribution in ocular tissue and to optimize the electron irradiation technique in highly critical structures. Using a voxelized eye phantom based on patient computed tomography images, the dose distribution can be estimated with a standard statistical uncertainty of less than 2.4% in 3 min using a computing cluster with 30 cores, which makes this planning technique clinically relevant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vibration

Man's reactions to vibration are emphasized rather than his reactions to the vibrational characteristics of vehicles. Vibrational effects studies include: performance effects reflected in tracking proficiency, reaction time, visual impairment, and other measures related to man's ability to control a system; physiological reactions; biodynamic responses; subjective reactions; and human tolerance limits. Technological refinements in shaker systems and improved experimental designs are used to validate the data.

Hornick, R. J.↗

Aeroacoustics of Flight Vehicles: Theory and Practice. Volume 2: Noise Control

Flight vehicles and the underlying concepts of noise generation, noise propagation, noise prediction, and noise control are studied. This volume includes those chapters that relate to flight vehicle noise control and operations: human response to aircraft noise; atmospheric propagation; theoretical models for duct acoustic propagation and radiation; design and performance of duct acoustic treatment; jet noise suppression; interior noise; flyover noise measurement and prediction; and quiet aircraft design and operational characteristics.

Hubbard, Harvey H.↗

Effect of Changing Weight and Mass on Human Performance in a Lunar Prototype Spacesuit

Physical effort, compensation, and controllability in a spacesuit can be affected by suit mass and gravity level. Because of limitations in certain reduced-gravity simulators and the finite selection of lunar prototype suits, it is difficult to ascertain how a change in suit mass affects suited human performance. One method of simulating a change in mass is to vary the total gravity-adjusted weight (TGAW), which is defined as the sum of the suit mass and subject mass, multiplied by the gravity level. PURPOSE: To determine if two methods of changing TGAW during parabolic flight - changing suit mass or gravity level - affect subjective ratings of suited human performance equally.METHODS: A custom weight support structure was connected to a lunar prototype spacesuit, allowing the addition of mass to the suit while maintaining a near-constant center of mass. In the varied-weight (VW) series, suit mass (120 kg) was constant at 0.1-g, 0.17-g, and 0.3-g, yielding TGAWs of 196, 333, and 588 N, assuming an 80-kg subject. In the varied-mass (VM) series, gravity level was constant at 0.17-g and suit mass was 89, 120, and 181 kg, yielding TGAWs of 282, 333, and 435 N. The 333 N condition was common to both series. Direct comparison was not possible due to limited adjustability of suit mass and limited options for parabolic profiles. Five astronaut subjects (80.311.8 kg) completed 4 different tasks (walk, bag pickup, lunge, and shoveling) in all conditions and provided ratings of perceived exertion (RPE) and the gravity compensation and performance scale (GCPS) upon completion of each task. RESULTS: Where VM and VW series overlapped, RPE and GCPS trend lines were similar. Mean RPE and GCPS at 333 N was 8.4 and 3.7. Mean RPE and GCPS for VM was 7.8 and 3.8 for 282 N and 9.8 and 4.1 for 435 N. Extrapolation of the VM trend to match VW TGAWs 196 and 588 N predicts an RPE of 6.5 and 12.3 and GCPS of 4.4 and 5.9, whereas the measured VW values for RPE were 8.1 and 9.8 and GCPS were 4.4 and 3.7. CONCLUSION: Modeling a change in suit mass by altering weight alone may be an adequate simulation through a limited range when looking at gross metrics of subjective suited human performance. Whether altering weight alone will be sufficient for more precise metrics of human performance, and across a wider range of activities, still needs further study

Chappell, Steve↗

A New Flow-Through Wind Tunnel Balance for Retropropulsion Testing

Supersonic retropropulsion is believed to be an enabling technology for large-scale human Mars lander vehicle concepts. Ground testing of such vehicles requires the development of new flow-through wind tunnel balances because no suitable balances exist. A new flow-through balance is designed that employs membranes in place of bellows, which have historically been used, and that passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure supersonic retropropulsion performance of powered descent vehicles.

Flow through balance↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Critical mission tasks that are required by crews immediately after landing on a planetary surface are seat egress, jump, and walk. To be able to define an effective and comprehensive countermeasure strategy for preserving crew performance during exploration-class missions, there is a need to understand how these functional tasks are actually performed in partial gravity such as on the Moon or Mars. We propose to study the performance in the execution of these tasks during the partial gravity and hypergravity phases of parabolic flight. These tasks will be completed using the same equipment and procedures as the Standard Measures Sensorimotor protocol, which is performed by astronauts returning from spaceflight and by ground-based subjects after prolonged axial body unloading during bed rest. HYPOTHESIS We hypothesize that partial gravity during parabolic flight will cause acute changes in vestibular, proprioceptive, and sensorimotor functions, and these changes will impact the performance of mission critical tasks such as standing, walking, and jumping. The largest changes in performance are expected at the lowest gravity level (0.25g) because subjects will no longer be able to use the gravitational reference for the perception of vertical. Ultimately, this information could be used to assess performance risks and inform the design of countermeasures for NASA exploration-class human missions. METHODS Twelve subjects will be tested during three flights of 30 parabolas, including 10 parabolas at 0.25g, 10 parabolas at 0.5g and 10 parabolas at 0.75g. Subject also will perform tests in 1g between parabolas and in hypergravity (1.8g) during the pull-out phases. Subjects will perform the same tasks as those tested on astronauts returning from spaceflight: sit-to-stand and obstacle walk, tandem walk, jump down, and recovery from fall. Measurements will include: (a) the time for the subject to complete the test (sit-to-stand and obstacle walk, recovery from fall); (b) the time elapsed between the start of motion and the stabilization of upright posture (recovery from fall, jump down); (c) the mean sway speed during quiet standing (recovery from fall, jump down); (d) changes in heart rate and blood pressure (recovery from fall); (e) the percentage of correct steps and torso acceleration (tandem walk); and (f) the severity of motion sickness symptoms. RELEVANCE Although gravitational dose-response curves have been obtained for some biochemical systems in animals, these dose-responses are unknown for most human physiologic systems. Our study will compare the outcomes of 5 functional task tests in 0.25g, 0.5g, 0.75g, 1g, and 1.8g with those previously obtained in ground-based subjects after prolonged axial body unloading and in astronauts immediately after spaceflight. This comparison will help understanding the true extent of functional task performance deficits in partial gravity. The dose-response relationship between gravity level and task performance decrement also will help determining the gravity threshold for these functional tasks. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element

Gilles Clement↗

NSCOR for Evaluating Risk Factors and Biomarkers for Adaptation and Resilience to Spaceflight: Emotional Valence and Social Processes in ICC/ICE Environments

Space exploration class missions, such as a mission to Mars, will require optimization of human performance, adaptability, and resilience. This NASA Specialized Center of Research (NSCOR) utilizes the NIMH Research Domain Criteria (RDoC) framework to identify biological and behavioral markers of individual social adaptation and emotional resilience (as well as vulnerability) to spaceflight-relevant stressors such as living in extended isolation. The overarching goal of this NSCOR is to obtain novel information to help identify biomarkers of individuals who are resilient and/or adaptable to the stressors of isolated, confined, and controlled (ICC) and isolated, confined, and extreme (ICE) environments.A total of N=90 healthy adult astronaut surrogates are being studied in three spaceflight-analog environments: (1) n=40 healthy adults in the Isolation and Confinement Analog Research Unit (ICARUS), an ICC at the University of Pennsylvania, during 7-day missions, for a target total of 280 subject days; (2) n=32 healthy adult astronaut surrogates studied in NASA’s Human Exploration Research Analog (HERA), an ICC at Johnson Space Center during 45-day missions, for a target total of 2,112 subject days; and (3) n=18 healthy adults in the Alfred-Wegener-Institute’s Neumayer Station III, an ICE in Antarctica, during 14-month missions, for a target total of 7,560 subject days. Dr. Nindl’s Laboratory at the University of Pittsburgh is analyzing a priori selected protein biomarkers in blood, saliva, and urine. Complementary rodent models of exposure to early life stressors, confinement, and isolation are being evaluated at Dr. Hensch’s Laboratory to further validate the neurobehavioral and biological findings from the human studies.Given the inconsistency and varied definition of resilience/adaptation in the scientific literature, the NSCOR team developed a composite resilience/adaptation measure that reflects the most relevant outcomes to resilience/adaptation across psychosocial and neurobehavioral functions, as well as neurocognitive and spaceflight-relevant operational performance. To achieve this, group consensus was attained from subject matter experts to produce a rank-order of importance for each input variable. The final resilience/adaptation score included 36 variables that were collected across spaceflight analogs. As of 10/1/2021, the NSCOR project acquired data on n=27 subjects at ICARUS, n=16 at HERA, and n=18 at Neumayer. The COVID-19 pandemic delayed data acquisition at ICARUS and HERA.Among subjects studied to date, 99% of neural and neurobehavioral data (e.g., neuroimaging for structure and function, behavioral measures) as well as blood, saliva, and urine for biochemical assays have been acquired. For rodent models, Dr. Hensch’s laboratory has established biochemical and behavioral parameters reflecting confinement stress in social networks of mice for comparison to stress responses in the human spaceflight analog environments.Group social behaviors were measured with a Social Network Analysis (SNA) approach to define objective parameters associated with sociability and its plasticity by sex. This analytic approach may help identify a network of individuals who are more effective teammates or more likely to generate new social relationships. Data acquisition, biomarker assessment, and data quality control will continue through September 2022.

D F Dinges↗

Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography

The goal of this study was to evaluate the improvement in electron density measurement and metal artifact reduction using orthovoltage computed tomography (OVCT) imaging compared with conventional kilovoltage CT (KVCT). For this study, a bench-top system was constructed with adjustable x-ray tube voltage up to 320 kVp. A commercial tissue-characterization phantom loaded with inserts of various human tissue substitutes was imaged using 125 kVp (KVCT) and 320 kVp (OVCT) x rays. Stoichiometric calibration was performed for both KVCT and OVCT imaging using the Schneider method. The metal inserts--titanium rods and aluminum rods--were used to study the impact of metal artifacts on the electron-density measurements both inside and outside the metal inserts. It was found that the relationships between Hounsfield units and relative electron densities (to water) were more predictable for OVCT than KVCT. Unlike KVCT, the stoichiometric calibration for OVCT was insensitive to the use of tissue substitutes for direct electron density calibration. OVCT was found to significantly reduce metal streak artifacts. Errors in electron-density measurements within uniform tissue substitutes were reduced from 42% (maximum) and 18% (root-mean-square) in KVCT to 12% and 2% in OVCT, respectively. Improvements were also observed inside the metal implants. For the detectors optimized for KVCT, the imaging dose is almost doubled for OVCT for the image quality comparable to KVCT. OVCT may be a good option for high-precision radiotherapy treatment planning, especially for patients with metal implants and especially for charged particle therapy, such as proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗