Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Visual sensitivity to spatially sampled modulation in human observers

Thresholds were measured for detecting spatial luminance modulation in regular lattices of visually discrete dots. Thresholds for modulation of a lattice are generally higher than the corresponding threshold for modulation of a continuous field, and the size of the threshold elevation, which depends on the spacing of the lattice elements, can be as large as a one log unit. The largest threshold elevations are seen when the sample spacing is 12 min arc or greater. Theories based on response compression cannot explain the further observation that the threshold elevations due to spatial sampling are also dependent on modulation frequency: the greatest elevations occur with higher modulation frequencies. The idea that this is due to masking of the modulation frequency by the spatial frequencies in the sampling lattice is considered.

Mulligan, Jeffrey B.↗

Effects of Varying Gravity Levels on fNIRS Headgear Performance and Signal Recovery

This paper reviews the effects of varying gravitational levels on functional Near-Infrared Spectroscopy (fNIRS) headgear. The fNIRS systems quantify neural activations in the cortex by measuring hemoglobin concentration changes via optical intensity. Such activation measurement allows for the detection of cognitive state, which can be important for emotional stability, human performance and vigilance optimization, and the detection of hazardous operator state. The technique depends on coupling between the fNIRS probe and users skin. Such coupling may be highly susceptible to motion if probe-containing headgear designs are not adequately tested. The lack of reliable and self-applicable headgear robust to the influence of motion artifact currently inhibits its operational use in aerospace environments. Both NASAs Aviation Safety and Human Research Programs are interested in this technology as a method of monitoring cognitive state of pilots and crew.

fNIRS↗

TPSAS-NF1676L-35370-DND

The above anvil cirrus plume (AACP) is a weather phenomenon that signifies an intense tropopause penetrating updraft which can inject cirrus clouds several kilometers into the stratosphere. Storms that have such intense updrafts are often supercells which generate severe weather such as tornadoes, high winds, and hail. In addition, AACPs moisten the stratosphere and influence the Earth's radiative balance. Though an AACP can be identified by the human eye, no automated AACP detection methods currently exist. Lack of detection inhibits understanding of where and how often AACPs occur, and how these storms influence stratospheric air composition. Previous work involved synthesis of multiple remote sensing and severe weather report/warning data sources to identify AACPs in Geostationary Operational Environmental Satellite system (GOES) satellite imagery and better understand their weather impacts (Bedka et al. (Wea. Forecasting, 2018)). This current study demonstrates an automated AACP identification method based on the application of a deep learning segmentation model known as a U-net. This study documents the development of a U-net model capable of identifying emergent AACPs using only satellite infrared (IR) and visible reflected sunlight imagery. The performance of a U-net is quantitatively benchmarked with human AACP identifications and qualitatively assessed through animations of detections generated from GOES-16 1-minute temporal resolution imagery.

Charles Liles↗

Nanoparticles for Enhanced Sensitivity in Electrochemical Immunoassays

In this manuscript, we report on electrochemical biosensors based on various nanoparticles (NPs) as labels for sensitive detection of protein biomarkers. We used silica nanoparticle as a carrier to loading a large amount of electroactive species such as poly(guanine) for sensitive immunoassay of tumor necrosis factor-alpha (TNF-a). We took the advantages of the unique hollow structure and reconstruction properties of apoferritin to prepare Cd3(PO4)2 nanoparticles as labels for sensitive assay of TNF-a. A novel immunochromatographic/electro-chemical biosensor based on quantum dots as labels has also been developed for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. These biosensors are quite sensitive with the detection limit at pM level and these approaches based on nanoparticle labels offer a new avenue for sensitive detection of protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Cell and molecular biology of simian virus 40: implications for human infections and disease

Simian virus 40 (SV40), a polyomavirus of rhesus macaque origin, was discovered in 1960 as a contaminant of polio vaccines that were distributed to millions of people from 1955 through early 1963. SV40 is a potent DNA tumor virus that induces tumors in rodents and transforms many types of cells in culture, including those of human origin. This virus has been a favored laboratory model for mechanistic studies of molecular processes in eukaryotic cells and of cellular transformation. The viral replication protein, named large T antigen (T-ag), is also the viral oncoprotein. There is a single serotype of SV40, but multiple strains of virus exist that are distinguishable by nucleotide differences in the regulatory region of the viral genome and in the part of the T-ag gene that encodes the protein's carboxyl terminus. Natural infections in monkeys by SV40 are usually benign but may become pathogenic in immunocompromised animals, and multiple tissues can be infected. SV40 can replicate in certain types of simian and human cells. SV40-neutralizing antibodies have been detected in individuals not exposed to contaminated polio vaccines. SV40 DNA has been identified in some normal human tissues, and there are accumulating reports of detection of SV40 DNA and/or T-ag in a variety of human tumors. This review presents aspects of replication and cell transformation by SV40 and considers their implications for human infections and disease pathogenesis by the virus. Critical assessment of virologic and epidemiologic data suggests a probable causative role for SV40 in certain human cancers, but additional studies are necessary to prove etiology.

Review↗

Alarm inhalation dosemeter for long living radioactive dust due to an uncontrolled release

MyRIAM is the acronym for My Radioactivity In Air Monitor and points out that the device was designed for personal use to detect any radioactivity in the air at the place and at the moment of danger. The active air sampling process enables a detection limit several orders of magnitude below that of Gamma detectors. Therefore, it is the unique way to detect dangerous exposures in time.Individual protection against inhalation of long living radioactive dust (LLRD) saves human life and health. LLRD may occur in natural environment as well as in case of nuclear accidence or military and terrorist attacks. But in any case, the immediate warning of the population is of great importance. Keep in mind: it is very easy to avoid LLRD inhalation--but you have to recognize the imminent danger. The second requirement of gap-less documentation and reliable assessment of any derived LLRD exposure is building the link to Dosimetry applications.The paper demonstrates the possibility to design small and low cost air samplers, which can be used as personal alarm dosimeters and fulfil the requirements mentioned above.Several test measurements taken by a mobile phone sized MyRIAM, shall be used to demonstrate the correctness of this statement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phenomena Portal: Large- Scale Visual Exploration of Atmospheric Phenomena

The Earth science community is experiencing a high influx of remote sensing data due to recent advancements in sensor technology. This enables the community to extend their research on a larger scale than ever before. Unfortunately, traditional data processing techniques do not scale well to these new, high volume data sources. State-of-the-art machine learning (ML) pipelines have been proven to overcome these burdens in various other fields but are underexploited within the physical sciences community. Moreover, ML is reliant on labeled data, which is currently sparsely available, owing to the fact that ML adoption is still in the early stages within the Earth and atmospheric science communities. To address these issues, we developed the Phenomena Portal, a visual exploration tool that uses ML to detect various atmospheric phenomena on a global scale. This allows the Earth and atmospheric science communities to view trends of occurrences of phenomena, identify potential relationships between them, and analyze spatiotemporal patterns over time. These detections can also serve as initial labeled data for ML research pertaining to the respective phenomena. The tool also incorporates feedback from subject matter experts to further improve the model detection accuracy, thereby facilitating human-in-the-loop. This presentation will provide an overview of the ML model development and cloud deployment. We also discuss the capabilities of the user interface for displaying the detections.

Muthukumaran Ramasubramanian↗

Prevalence of NS5A resistance associated variants in NS5A inhibitor treatment failures and an effective treatment for NS5A-P32 deleted hepatitis C virus in humanized mice

Highlights: • NS5A-P32 deletions were detected in 4.3% of genotype 1 HCV-infected patients with prior NS5A inhibitors treatment failure. • Efficacy of glecaprevir and pibrentasvir treatment for NS5A-P32 deleted HCV is lower compared to the wild-type strain. • Sofosbuvir plus glecaprevir and pibrentasvir combination treatment was effective for NS5A-P32del in humanized mice. Patients with chronic hepatitis C virus (HCV) infection who have failed to respond to direct-acting antiviral (DAA) treatment often acquire drug resistance-associated variants (RAVs). The NS5A-P32 deletion (P32del) RAV confers potent resistance to NS5A inhibitors; therefore, patients who acquire this deletion are likely to fail to respond to DAA re-treatment. We investigated the prevalence of N55A-P32del in patients who failed to respond to prior NS5A inhibitor treatment using direct sequencing and analyzed the efficacy of DAA combination treatment in the presence of NS5A-P32del RAVs using human hepatocyte transplanted mice. NS5A-P32del was detected in one of 23 (4.3%) patients who had failed to respond to prior NS5A inhibitor treatment. Although four weeks of NS3/4A protease inhibitor glecaprevir plus NS5A inhibitor pibrentasvir treatment effectively suppressed HCV replication in wild-type HCV-infected mice, serum HCV RNA never became negative in P32del HCV-infected mice. When P32del HCV-infected mice were treated with four weeks of glecaprevir plus pibrentasvir combined with the NS5B polymerase inhibitor sofosbuvir, serum HCV RNA became negative, and the virus was eliminated from the liver in three out of four mice. We conclude that the combination of sofosbuvir and glecaprevir plus pibrentasvir may be an effective new treatment option for patients with NS5A-P32del.

60 APPLIED LIFE SCIENCES↗

Simian virus 40, poliovirus vaccines, and human cancer: research progress versus media and public interests

From 1955 through early 1963, millions of people were inadvertently exposed to simian virus 40 (SV40) as a contaminant of poliovirus vaccines; the virus had been present in the monkey kidney cultures used to prepare the vaccines and had escaped detection. SV40 was discovered in 1960 and subsequently eliminated from poliovirus vaccines. This article reviews current knowledge about SV40 and considers public responses to reports in the media. SV40 is a potent tumour virus with broad tissue tropism that induces tumours in rodents and transforms cultured cells from many species. It is also an important laboratory model for basic studies of molecular processes in eukaryotic cells and mechanisms of neoplastic transformation. SV40 neutralizing antibodies have been detected in individuals not exposed to contaminated poliovirus vaccines. There have been many reports of detection of SV40 DNA in human tumours, especially mesotheliomas, brain tumours and osteosarcomas; and DNA sequence analyses have ruled out the possibility that the viral DNA in tumours was due to laboratory contamination or that the virus had been misidentified. However, additional studies are necessary to prove that SV40 is the cause of certain human cancers. A recently published review article evaluated the status of the field and received much media attention. The public response emphasized that there is great interest in the possibility of health risks today from vaccinations received in the past.

Review, Tutorial↗

Semiautomatic vessel wall detection and quantification of wall thickness in computed tomography images of human abdominal aortic aneurysms

Purpose: Quantitative measurements of wall thickness in human abdominal aortic aneurysms (AAAs) may lead to more accurate methods for the evaluation of their biomechanical environment. Methods: The authors describe an algorithm for estimating wall thickness in AAAs based on intensity histograms and neural networks involving segmentation of contrast enhanced abdominal computed tomography images. The algorithm was applied to ten ruptured and ten unruptured AAA image data sets. Two vascular surgeons manually segmented the lumen, inner wall, and outer wall of each data set and a reference standard was defined as the average of their segmentations. Reproducibility was determined by comparing the reference standard to lumen contours generated automatically by the algorithm and a commercially available software package. Repeatability was assessed by comparing the lumen, outer wall, and inner wall contours, as well as wall thickness, made by the two surgeons using the algorithm. Results: There was high correspondence between automatic and manual measurements for the lumen area (r=0.978 and r=0.996 for ruptured and unruptured aneurysms, respectively) and between vascular surgeons (r=0.987 and r=0.992 for ruptured and unruptured aneurysms, respectively). The authors' automatic algorithm showed better results when compared to the reference with an average lumen error of 3.69%, which is less than half the error between the commercially available application Simpleware and the reference (7.53%). Wall thickness measurements also showed good agreement between vascular surgeons with average coefficients of variation of 10.59% (ruptured aneurysms) and 13.02% (unruptured aneurysms). Ruptured aneurysms exhibit significantly thicker walls (1.78{+-}0.39 mm) than unruptured ones (1.48{+-}0.22 mm), p=0.044. Conclusions: While further refinement is needed to fully automate the outer wall segmentation algorithm, these preliminary results demonstrate the method's adequate reproducibility and low interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamically Multiplexed Ion Mobility Time-of-Flight Mass Spectrometry

Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometry (IMS-TOFMS) has been increasingly used in analysis of complex biological samples. A major challenge is to transform IMS-TOFMS to a high-sensitivity high-throughput platform for e.g. proteomics applications. In this work, we have developed and integrated three advanced technologies, enabling (1) efficient ion accumulation in the ion funnel trap prior to IMS separation, (2) multiplexing (MP) of ion packet introduction into the IMS drift tube and (3) signal detection with an analog-to-digital converter (ADC), into the IMS-TOFMS system for the high-throughput analysis of highly complex proteolytic digests of e.g. blood plasma. To better address variable sample complexity, we have additionally developed and rigorously evaluated a new dynamic MP approach that ensures correlation of the analyzer performance with an ion source function, and provides the improved dynamic range and sensitivity. The MP IMS-TOF MS instrument has been shown to reliably detect peptides at a concentration of 1 nM in a highly complex matrix, as well as to provide a four orders of magnitude dynamic range and a mass measurement accuracy of better than 5 ppm. When matched against human blood plasma database, the detected IMS-TOF features yielded ~ 700 unique peptide identifications at a false discovery rate (FDR) of ~ 7.5 %. Accounting for IMS information gave rise to a projected FDR of ~ 4 %. Signal reproducibility was found to be greater than 80 %, while the variations in the number of unique peptide identifications were < 15 %. A single sample analysis was completed in 15 min, corresponding to approximately an order of magnitude improvement compared to a more conventional LC-MS approach.

Belov, Mikhail E.↗

Sensing Technology Survey for Obstacle Detection in Vegetation

This study reviews obstacle detection technologies in vegetation for autonomous vehicles or robots. Autonomous vehicles used in agriculture and as lawn mowers face many environmental obstacles that are difficult to recognize for the vehicle sensor. This review provides information on choosing appropriate sensors to detect obstacles through vegetation, based on experiments carried out in different agricultural fields. The experimental setup from the literature consists of sensors placed in front of obstacles, including a thermal camera; red, green, blue (RGB) camera; 360° camera; light detection and ranging (LiDAR); and radar. These sensors were used either in combination or single-handedly on agricultural vehicles to detect objects hidden inside the agricultural field. The thermal camera successfully detected hidden objects, such as barrels, human mannequins, and humans, as did LiDAR in one experiment. The RGB camera and stereo camera were less efficient at detecting hidden objects compared with protruding objects. Radar detects hidden objects easily but lacks resolution. Hyperspectral sensing systems can identify and classify objects, but they consume a lot of storage. To obtain clearer and more robust data of hidden objects in vegetation and extreme weather conditions, further experiments should be performed for various climatic conditions combining active and passive sensors.

33 ADVANCED PROPULSION SYSTEMS↗

Some new control theoretic models for human operator display monitoring

Control theoretic techniques are applied to develop two new models for predicting human operator performance when monitoring an automatically controlled system. In one case it is assumed that the human monitors the instruments in order to rapidly detect failures. The second approach assumes that the instruments are sampled to best reconstruct the system status information. The relation of these models to existing prediction schemes, e.g., equal attention and the Sender's (1964) model is explored. It is concluded that a combination of failure detection and status estimation models offers the best potential for human operator application.

Kleinman, D. L.↗

Some new control theoretic models for human operator display monitoring

Control theoretic techniques are applied to develop two new models for predicting human operator performance when monitoring an automatically controlled system. In one case it is assumed that the human monitors the instruments in order to rapidly detect failures. A second approach assumes that the instruments are sampled to best reconstruct the system status information. The relation of these models to existing prediction schemes, e.g., equal attention and the Senders model is explored. It is concluded that a combination of failure detection and status estimation models offers the best potential for human operator application.

Kleinman, D. L.↗

RCUT: A Non-Invasive Method for Detection, Location, and Quantification of Radiological Contaminants in Pipes and Ducts - 12514

Radiological Characterization Using Tracers (RCUT) is a minimally invasive method for detection and location of residual radiological contamination in pipes and ducts. The RCUT technology utilizes reactive gaseous tracers that dissociate when exposed to gamma and/or beta radiation emitting from a radiological contaminant in a pipe or duct. Sulfur hexafluoride (SF{sub 6}) was selected as a tracer for this radiological application, because it is a chemically inert gas that is both nonflammable, nontoxic, and breaks down when exposed to gamma radiation. Laboratory tests demonstrated that the tracer pair of SF{sub 6} and O{sub 2} formed SO{sub 2}F{sub 2} when exposed to a gamma or beta radioactive field, which indicated the presence of radiological contamination. Field application of RCUT involves first injecting the reactive tracers into the pipe to fill the pipe being inspected and allowing sufficient time for the tracer to interact with any contaminants present. This is followed by the injection of an inert gas at one end of the pipe to push the reactive tracer at a known or constant flow velocity along the pipe and then out the exit and sampling port at the end of the pipeline where its concentration is measured by a gas chromatograph. If a radiological contaminant is present in the pipe being tested, the presence of SO{sub 2}F{sub 2} will be detected. The time of arrival of the SO{sub 2}F{sub 2} can be used to locate the contaminant. If the pipe is free of radiological contamination, no SO{sub 2}F{sub 2} will be detected. RCUT and PCUT are both effective technologies that can be used to detect contamination within pipelines without the need for mechanical or human inspection. These methods can be used to detect, locate, and/or estimate the volume of a variety of radioactive materials and hazardous chemicals such as chlorinated solvents, petroleum products, and heavy metals. While further optimization is needed for RCUT, the key first step of identification of a tracer compound appropriate for the application of detecting radioactive pipeline contamination through the detection of decomposition products of SF{sub 6} has been demonstrated. Other tracer gases that will also undergo radiolysis will be considered in the future. The next step for the RCUT development process is conducting laboratory scale tests using short pipelines to define analytical requirements, establish performance boundaries, and develop strategies for lower exposure levels. Studies to identify additional analytical techniques using equipment that is more field rugged than a GC/MS would also be beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toxicokinetics of acrylamide in rats and humans following single oral administration of low doses

The rodent carcinogen acrylamide (AA) is formed during preparation of starch-containing foods. AA is partly metabolized to the genotoxic epoxide glycidamide (GA). After metabolic processing, the mercapturic acids N-acetyl-S-(2-carbamoylethyl)-L-cysteine (AAMA), rac-N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-L-cysteine (GAMA) and rac-N-acetyl-S-(1-carbamoyl-moyl-2-hydroxyethyl)-L-cysteine (iso-GAMA) are excreted with urine. In humans, AAMA can be sulfoxidized to AAMA-sulfoxide. The aim of this study was to assess potential species-differences in AA-toxicokinetics in rats and humans after single oral administration of doses similar to the daily human dietary exposure. Male Fischer 344 rats (n = 5/dose group) were administered 20 and 100 {mu}g/kg b.w. {sup 13}C{sub 3}-AA in deionized water via oral gavage. Human subjects (n = 3/gender) were orally administered 0.5 and 20 {mu}g/kg b.w. {sup 13}C{sub 3}-AA with drinking water. Urine samples were collected in intervals for 96 and 94 h, respectively. Urinary concentrations of {sup 13}C{sub 3}-AAMA, {sup 13}C{sub 3}-GAMA and {sup 13}C{sub 3}-AAMA-sulfoxide were monitored by liquid chromatography-tandem mass spectrometry. The recovered urinary metabolites accounted for 66.3% and 70.5% of the 20 and 100 {mu}g/kg b.w. doses in rats and for 71.3% and 70.0% of the 0.5 and 20 {mu}g/kg b.w. doses in humans. In rats, {sup 13}C{sub 3}-AAMA accounted for 33.6% and 38.8% of dose and 32.7% and 31.7% of dose was recovered as {sup 13}C{sub 3}-GAMA; {sup 13}C{sub 3}-AAMA-sulfoxide was not detected in rat urine. In humans, {sup 13}C{sub 3}-AAMA, {sup 13}C{sub 3}-GAMA and {sup 13}C{sub 3}-AAMA-sulfoxide accounted for 51.7% and 49.2%, 6.3% and 6.4% and 13.2% and 14.5% of the applied dose, respectively. The obtained results suggest that the extent of AA bioactivation to GA in humans is lower than in rodents.

60 APPLIED LIFE SCIENCES↗

Eddy covariance towers as sentinels of abnormal radioactive material releases

Ensuring accurate detection and attribution of abnormal releases of radioactive material is critical for protecting human health and safety. Most commonly, such detection is accomplished via active monitoring approaches involving the collection of physical samples. Further, this is labor intensive and limits the temporal and spatial resolution of any detected events to a relatively coarse level. As an alternative first step towards passive monitoring, we developed an approach using eddy flux tower data records to identify signals from a known abnormal release and quantify the extent to which that signal also occurs at other times in the data record. Through two case studies, one of which targeted the Fukushima nuclear disaster and the other targeting an abnormal release event at a radioisotope production facility in Fleurus, Belgium, we tested our approach and identified several potential heretofore unidentified abnormal events that were consistent with atmospheric circulation patterns and/or wind direction from known release sites. Because our approach is relatively simple and is resistant to systematic errors in the observational record, it has broad applicability beyond specific constituents and ecosystem types to identify a wide variety of limited-duration anomalies in flux tower data to ensure human health and industrial safety.

54 ENVIRONMENTAL SCIENCES↗