Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high frequency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rotating Unbalanced-Mass devices for scanning: Results from the proof-of-concept test

Rotating unbalanced-mass (RUM) devices are a new way to scan space-based, balloon-borne, and ground-based gimbaled payloads, like x-ray and gamma-ray telescopes. They can also be used to scan free-flying spacecraft. Circular scans, linear scans, and raster scans can be generated. A pair of RUM devices generates the basic scan motion and an auxiliary control system using torque motors, control moment gyros, or reaction wheels keeps the scan centered on the target and produces some complementary motion for raster scanning. Previous analyses and simulation results show that this approach offers significant power savings compared to scanning only with the auxiliary control system, especially with large payloads and high scan frequencies. However, these claims have never been proven until now. This paper describes a laboratory experiment which tests the concept of scanning a gimbaled payload with RUM devices. The test results are compared with those from a computer simulation model of the experiment and the differences are discussed.

Alhorn, Dean C.↗

Great microwave bursts and hard X-rays from solar flares

In the present study of the microwave and hard X-ray characteristics of 13 solar flares emitting microwave fluxes greater than 500 solar flux units, simultaneous 3-35 GHz and hard X-ray observations were conducted in the 30-500 keV energy range. An analysis is conducted to determine whether the same distribution of energetic electrons can explain both emissions; tests for any correlations between them yield results suggesting that optically thick microwave emission, near the peak frequency, originates in the same electron population that produces the hard X-rays. A single temperature model and a multitemperature model were tested for consistency with the coincident X-ray and microwave spectra at microwave burst maximum; neither model, however, attempts to explain the high frequency component of the microwave spectrum.

Wiehl, H. J.↗

Research and test facilities

A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).

Source record↗

Test results from a simple, low-cost, pressure-fed liquid hydrogen/liquid oxygen rocket combustor

A simple, low-cost rocket engine was designed, fabricated, and successfully hot fire tested over a wide range of interface conditions and operating parameters. The engine used low enthalpy hydrogen (45 to 70 R, 200 to 390 psia) and oxygen (139 to 163 R, 210 to 480 psia) propellants pressure-fed directly from facility cryogenic tanks. The engine demonstrated excellent performance, with 97% average combustion efficiency, and absence of combustion instabilities. Engine design chamber pressure was 300 psia, yielding about 16,500 pounds thrust at sea level with a 3:1 expansion ration test nozzle. The engine used a fixed-element injector based on TRW's unique coaxial pintle design, but was operated at 60%, 80%, and 100% thrust levels by throttling facility propellant valves. The engine was tested at propellant mixture ratios (O/F) from 5.8 to 8.4; design O/F was 6.6. To document combustion stability, in five tests RDX explosive pulse guns were detonated in radial and tangential directions across the combustion chamber during steady-state operation. The largest disturbance consisted of simultaneous detonation of a 20-grain radial gun and a 40-grain tangential gun. In no case was an instability, either feed system mode or chamber acoustic mode, excited. High-frequency piezoelectric pressure transducers documented stable recovery from disturbance overpressures within 40 milliseconds of peak pressure. A total of 67 firing tests, accumulating 149 seconds of firing time above 10% P(sub c), were performed. Since parametric testing required run durations of only 2 to 3 seconds, a heat sink combustion chamber was employed for most runs. To evaluate the feasibility of a low-cost ablative system for a flight engine design, one 20-second continuous firing was conducted with a silicone rubber chamber/throat/nozzle liner cast in one piece directly into the engine. The ablative engine operated at the equivalent of 309 seconds sea level specific impulse, when adjusted to a 98% efficient 6:1 expansion ration nozzle, and 430 seconds vacuum specific impulse, when adjusted to a 98% efficient 50:1 expansion ratio nozzle. This engine and test series represent an initial subscale demonstration of a new booster-class engine that eliminates the cost and complexity associated with regenerative cooling and typical engine cycles. This paper presents a description of the engine design and discussion and summary data plots of the performance measured during the parametric testing.

Dressler, G. A.↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗

Results of a laboratory experiment that tests rotating unbalanced-mass devices for scanning gimbaled payloads and free-flying spacecraft

Rotating unbalanced-mass (RUM) devices are a new way to scan space-based, balloon-borne, and ground-based gimbaled payloads, like x-ray and gamma-ray telescopes. They can also be used to scan free-flying spacecraft. Circular scans, linear scans, and raster scans can be generated. A pair of RUM devices generates the basic scan motion and an auxiliary control system using torque motors, control moment gyros, or reaction wheels keeps the scan centered on the target and produces some complementary motion for raster scanning. Previous analyses and simulation results show that this approach offers significant power savings compared to scanning only with the auxiliary control system, especially with large payloads and high scan frequencies. However, these claims have never been proven until now. This paper describes a laboratory experiment which tests the concept of scanning a gimbaled payload with RUM devices. A description of the experiment is given and test results that prove the concept are presented. The test results are compared with those from a computer simulation model of the experiment and the differences are discussed.

Alhorn, D. C.↗

Ramp technique for dc partial discharge testing

The partial discharge (PD) data presently obtained by means of a stepwise ramp technique, for the cases of high voltage (HV) components and such resin-packaged HV devices as the Space Telescope's Faint Object Camera, is acquired separately on part-way ramps to rated voltage and on the intermediate voltage plateaus. For test specimens intended for dc service, this ramp method yields more data on insulation integrity than quiescent dc measurements, especially in the case of specimens of high resistivity which causes the discharge frequency to be deceptively low at constant dc voltage. During upward ramping the voltage distribution is capacitive, and the PD behavior resembles that of an ac test. Many more pulses are obtained in the voids without the heat otherwise generated by the application of 60-Hz ac. PD histograms are presented for various materials, with and without intentional defects.

Bever, R. S.↗

Wind tunnel tests of a blade subjected to midchord torsional oscillation at high subsonic stall flutter conditions

A mechanical drive system for oscillating blades in a wind tunnel at frequencies up to 767 hertz and amplitudes of + or - 1.2 deg is described. High-speed motion pictures of schlieren images of the flow over a double-circular arc blade oscillating in harmonic motion about the midchord revealed extensive shock patterns at a nominal free stream Mach number of 0.7, a mean angle of attack of 4 deg, and reduced frequency of about 0.7. A phase lag resulting from the slow response of the flow to the motion of the blade increased with increasing reduced frequency. This phase lag, based on the difference between the time the blade attained its maximum angle of attack and the time required for the normal shock to reach its extreme downstream position, was nominally 100 deg at the above conditions.

Boldman, D. R.↗

High-Frequency Density Oscillations from a Plasma Source Used for Simulating Low-Earth Orbit Plasma Environment

We present data from ground-based, vacuum-chamber tests demonstrating the ability to modulate the output of a plasma source capable of producing a low-Earth orbit (LEO) type plasma. We obtained plasma oscillations up to 2.5 kHz impingent on stationary test equipment, which corresponds to meter-level ionospheric structures in LEO. This plasma source is, therefore, suitable for developing scientific instruments that measure the LEO plasma environment, in situ, with meter-level spatial resolution. Measurements were made using a fixed-bias collector and an electrometer sampling at 40 kHz. A mechanical aperture was established at the output of the plasma source via two concentric grids. The outer grid was free to rotate in the azimuthal direction with respect to the fixed inner grid. An identical, alternating hole pattern in the two grids resulted in a variable aperture that cycles through 90 open/close cycles per revolution. The frequency of the plasma oscillations is limited by the mechanism used to spin the grids and the bearing assembly on which the grids rotate. Higher frequencies are obtainable by upgrading the drive mechanism, allowing the possibility of centimeter-level spatial resolution.

McTernan, Jesse K.↗

Low-Cost, Efficient and Durable High Temperature Wireless Sensors by Direct Write Additive Manufacturing for Application in Fossil Energy Systems

In-situ monitoring of physical parameters in fossil energy (FE) systems is challenging because of their high operating temperatures and oxidizing environments. This research aims utilize Aerosol Jet (AJ) nanoparticle printing, an advanced additive manufacturing method, to fabricate high temperature sensors for FE applications. Sensor films were fabricated by the AJ printing method with an excellent control over film microstructure and properties, in addition to creating less waste. Printing of six different materials, namely, silver (Ag), nickel (Ni), nickel-chromium (NiCr) alloy, copper (Cu), copper-nickel (CuNi), and carbon nanotubes (CNTs) was carried out for their evaluation of as sensor films. The films were then characterized using impedance spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), x-ray diffraction (XRD), and x-ray photoelectron spectroscopy (XPS). Film microstructure was correlated with the sensor electrical and mechanical behavior at different temperatures (24-500 °C) and frequencies (0.02 - 300 kHz). This knowledge was then used to fabricate, test, and characterize strain and temperature sensors for high temperature applications. The strain sensors were shown to have a very low thermal strain up to 500 °C and a 57% higher gauge factor compared to the commercially available counterparts. This enhance performance was attributed to the inherent porosity in the sensor films that allowed the films to exhibit a metamaterial-like behavior when deformed. The AJ printed temperature sensors were shown to have the highest Seebeck coefficient amongst all the film-based temperature sensors. In addition, fundamental aspects of crystal structure and phase transformations in Ba(Fe0.7Ta0.3)O3-δ (BFTO), a high temperature sensor material, was investigated along with 3D printed antennas that can transmit sensor signals at high temperatures. Two PhD students, one from first generation college-going underrepresented minority community (URM), two postdoctoral fellows, and several masters and undergraduate students were supported by this award. This work opens up the possibility of realizing low-cost high-performance sensor devices using advanced manufacturing techniques for high temperature FE applications.

20 FOSSIL-FUELED POWER PLANTS↗

Benefits of Spacecraft Level Vibration Testing

NASA-HDBK-7008 Spacecraft Level Dynamic Environments Testing discusses the approaches, benefits, dangers, and recommended practices for spacecraft level dynamic environments testing, including vibration testing. This paper discusses in additional detail the benefits and actual experiences of vibration testing spacecraft for NASA Goddard Space Flight Center (GSFC) and Jet Propulsion Laboratory (JPL) flight projects. JPL and GSFC have both similarities and differences in their spacecraft level vibration test approach: JPL uses a random vibration input and a frequency range usually starting at 5 Hz and extending to as high as 250 Hz. GSFC uses a sine sweep vibration input and a frequency range usually starting at 5 Hz and extending only to the limits of the coupled loads analysis (typically 50 to 60 Hz). However, both JPL and GSFC use force limiting to realistically notch spacecraft resonances and response (acceleration) limiting as necessary to protect spacecraft structure and hardware from exceeding design strength capabilities. Despite GSFC and JPL differences in spacecraft level vibration test approaches, both have uncovered a significant number of spacecraft design and workmanship anomalies in vibration tests. This paper will give an overview of JPL and GSFC spacecraft vibration testing approaches and provide a detailed description of spacecraft anomalies revealed.

Spacecraft Vibration Test↗

Excitations for Rapidly Estimating Flight-Control Parameters

A flight test on an F-15 airplane was performed to evaluate the utility of prescribed simultaneous independent surface excitations (PreSISE) for real-time estimation of flight-control parameters, including stability and control derivatives. The ability to extract these derivatives in nearly real time is needed to support flight demonstration of intelligent flight-control system (IFCS) concepts under development at NASA, in academia, and in industry. Traditionally, flight maneuvers have been designed and executed to obtain estimates of stability and control derivatives by use of a post-flight analysis technique. For an IFCS, it is required to be able to modify control laws in real time for an aircraft that has been damaged in flight (because of combat, weather, or a system failure). The flight test included PreSISE maneuvers, during which all desired control surfaces are excited simultaneously, but at different frequencies, resulting in aircraft motions about all coordinate axes. The objectives of the test were to obtain data for post-flight analysis and to perform the analysis to determine: 1) The accuracy of derivatives estimated by use of PreSISE, 2) The required durations of PreSISE inputs, and 3) The minimum required magnitudes of PreSISE inputs. The PreSISE inputs in the flight test consisted of stacked sine-wave excitations at various frequencies, including symmetric and differential excitations of canard and stabilator control surfaces and excitations of aileron and rudder control surfaces of a highly modified F-15 airplane. Small, medium, and large excitations were tested in 15-second maneuvers at subsonic, transonic, and supersonic speeds. Typical excitations are shown in Figure 1. Flight-test data were analyzed by use of pEst, which is an industry-standard output-error technique developed by Dryden Flight Research Center. Data were also analyzed by use of Fourier-transform regression (FTR), which was developed for onboard, real-time estimation of the derivatives.

Moes, Tim↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗