Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SWIM: A Semi-Analytical Ocean Color Inversion Algorithm for Optically Shallow Waters

Ocean color remote sensing provides synoptic-scale, near-daily observations of marine inherent optical properties (IOPs). Whilst contemporary ocean color algorithms are known to perform well in deep oceanic waters, they have difficulty operating in optically clear, shallow marine environments where light reflected from the seafloor contributes to the water-leaving radiance. The effect of benthic reflectance in optically shallow waters is known to adversely affect algorithms developed for optically deep waters [1, 2]. Whilst adapted versions of optically deep ocean color algorithms have been applied to optically shallow regions with reasonable success [3], there is presently no approach that directly corrects for bottom reflectance using existing knowledge of bathymetry and benthic albedo.To address the issue of optically shallow waters, we have developed a semi-analytical ocean color inversion algorithm: the Shallow Water Inversion Model (SWIM). SWIM uses existing bathymetry and a derived benthic albedo map to correct for bottom reflectance using the semi-analytical model of Lee et al [4]. The algorithm was incorporated into the NASA Ocean Biology Processing Groups L2GEN program and tested in optically shallow waters of the Great Barrier Reef, Australia. In-lieu of readily available in situ matchup data, we present a comparison between SWIM and two contemporary ocean color algorithms, the Generalized Inherent Optical Property Algorithm (GIOP) and the Quasi-Analytical Algorithm (QAA).

QAA↗

Clinical Outcome Metrics for Optimization of Robust Training

Introduction: The emphasis of this research is on the Human Research Program (HRP) Exploration Medical Capability's (ExMC) "Risk of Unacceptable Health and Mission Outcomes Due to Limitations of In-Flight Medical Capabilities." Specifically, this project aims to contribute to the closure of gap ExMC 2.02: We do not know how the inclusion of a physician crew medical officer quantitatively impacts clinical outcomes during exploration missions. The experiments are specifically designed to address clinical outcome differences between physician and non-physician cohorts in both near-term and longer-term (mission impacting) outcomes. Methods: Medical simulations will systematically compare success of individual diagnostic and therapeutic procedure simulations performed by physician and non-physician crew medical officer (CMO) analogs using clearly defined short-term (individual procedure) outcome metrics. In the subsequent step of the project, the procedure simulation outcomes will be used as input to a modified version of the NASA Integrated Medical Model (IMM) to analyze the effect of the outcome (degree of success) of individual procedures (including successful, imperfectly performed, and failed procedures) on overall long-term clinical outcomes and the consequent mission impacts. The procedures to be simulated are endotracheal intubation, fundoscopic examination, kidney/urinary ultrasound, ultrasound-guided intravenous catheter insertion, and a differential diagnosis exercise. Multiple assessment techniques will be used, centered on medical procedure simulation studies occurring at 3, 6, and 12 months after initial training (as depicted in the following flow diagram of the experiment design). Discussion: Analysis of procedure outcomes in the physician and non-physician groups and their subsets (tested at different elapsed times post training) will allow the team to 1) define differences between physician and non-physician CMOs in terms of both procedure performance (pre-IMM analysis) and overall mitigation of the mission medical impact (IMM analysis); 2) refine the procedure outcome and clinical outcome metrics themselves; 3) refine or develop innovative medical training products and solutions to maximize CMO performance; and 4) validate the methods and products of this experiment for operational use in the planning, execution, and quality assurance of the CMO training process The team has finalized training protocols and developed a software training/testing tool in collaboration with Butler Graphics (Detroit, MI). In addition to the "hands on" medical procedure modules, the software includes a differential diagnosis exercise (limited clinical decision support tool) to evaluate the diagnostic skills of participants. Human subject testing will occur over the next year.

Ebert, D.↗

Multiperspective analysis and testing of expert systems

The paper describes a technique which the author developed for testing expert systems. The technique, which he calls multiperspective testing, can be applied during both the knowledge engineering phase and the acceptance testing phase of developing an exppert system. The first step in multiperspective testing is to define a group of performance measures ('perspectives') that focus on the behavior of the knowledge base. For each such measure, the results of testing are summarized in four scores, which the author calls 'expansion,' 'detection,' 'discrimination,' and 'comprehension.' These scores have the advantage of providing more specific information about how the knowledge base should be updated or corrected.

Bollinger, Terry B.↗

The Surface Fatigue Life of Contour Induction Hardened AISI 1552 Gears

Two groups of spur gears manufactured from two different materials and heat treatments were endurance tested for surface fatigue life. One group was manufactured from AISI 1552 and was finished ground to a 0.4 micron (16 micro-in.) rms surface finish and then dual frequency contour induction hardened. The second group was manufactured from CEVM AISI 9310 and was carburized, hardened, and ground to a 0.4 micron (16 micro-in.) rms surface finish. The gear pitch diameter was 8.89 cm (3.5 in.). Test conditions were a maximum Hertz stress of 1.71 GPa (248 ksi), a bulk gear temperature of approximately 350 K (170 F) and a speed of 10,000 rpm. The lubricant used for the tests was a synthetic paraffinic oil with an additive package. The test results showed that the 10 percent surface fatigue (pitting) life of the contour hardened AISI 1552 test gears was 1.7 times that of the carburized and hardened AISI 9310 test gears. Also there were two early failures of the AISI 1552 gears by bending fatigue.

Townsend, Dennis P.↗

The effect of dietary supplementation of Lycium barbarum leaves on the growth performance, organ indexes and intestinal microflora of rats

This study was conducted to investigate both fruit and different levels of leaf supplementation on the growth performance, organ indices and intestinal microflora of rats. Twenty-five healthy male Sprague–Dawley rats were randomly divided into five groups. The rats in the control (NC) and positive control (PC) groups were fed by gavage a basal diet and a basal diet with 4 g/kg of L. barbarum fruit homogenate, respectively. The test (LD, MD, and HD) groups were fed basal diets with additional 2, 4, and 8 g/kg of L. barbarum leaf homogenate, respectively. The feeding period was 35 d. The result revealed that the rats in the LD group had the highest average weight gain ( p < 0.05). The cardiac and renal indexes in the LD and MD groups were significantly higher than in NC group, respectively ( p < 0.05). Diversity analysis revealed that adding low concentrations of L. barbarum leaf homogenates markedly reduced the Shannon index of the rats cecum ( p < 0.05). The relative abundance of Verrucomicrobiota was higher in the LD group than those in other groups ( p < 0.05). The relative abundance of Actinobacteriota was found significantly higher in PC group than others ( p < 0.05). The relative abundance of Akkermansia in LD group was the highest ( p < 0.05). The relative abundance of Romboutsia in the PC group was considerably higher than that in other groups. The relative abundance of Candidatus_Saccharimonas in the supplementation groups was appreciably lower than those found in other groups. The relative abundance of Alloprevotella was significantly lower in PC, LD, and MD groups than in NC and HD groups ( p < 0.05). The relative abundance of Oscillibacter was significantly higher in HD group than in other groups ( p < 0.05). Thus, L. barbarum leaf homogenate fed to rats could increase their growth performance, internal organ weights and additionally enhance the relative abundance of beneficial bacteria. Therefore, based on the obtained data in the current study, a dose of L. barbarum leaf homogenate supplemented with 2 g/kg in diet is recommended, however, further studies are required to confirm, especially in animals.

Guo, Yindi↗

Effect of shot peening on surface fatigue life of carburized and hardened AISI 9310 spur gears

Surface fatigue tests were conducted on two groups of AISI 9310 spur gears. Both groups were manufactured with standard ground tooth surfaces, with the second group subjected to an additional shot peening process on the gear tooth flanks. The gear pitch diameter was 8.89 cm (3.5 in.). Test conditions were a gear temperature of 350 K (170 F), a maximum Hertz stress of 1.71 billion N/sq m (248,000 psi), and a speed of 10,000 rpm. The shot peened gears exhibited pitting fatigue lives 1.6 times the life of standard gears without shot peening. Residual stress measurements and analysis indicate that the longer fatigue life is the result of the higher compressive stress produced by the shot peening. The life for the shot peened gear was calculated to be 1.5 times that for the plain gear by using the measured residual stress difference for the standard and shot peened gears. The measured residual stress for the shot peened gears was much higher than that for the standard gears.

Townsend, D. P.↗

Mars Ascent Vehicle Hybrid Propulsion Development

Hybrid propulsion is being investigated as a propulsion method for a possible Mars Ascent Vehicle (MAV) application. MAV is part of a proposed larger Mars Sample Return (MSR) campaign plan to bring samples from Mars to earth for examination. The Mars Ascent Vehicle would launch Mars surface samples found and packaged by the Mars 2020 mission to orbit around Mars. This version of hybrid propulsion is based on a wax based solid fuel, called SP7A, and a Mixed Oxides of Nitrogen oxidizer, MON-25. SP7 is a new fuel formulation developed by Space Propulsion Group and was modified for this application to be resistant to Mars temperature extremes and modified again to lower the regression rate to become SP7A. MON-25 was chosen for its low freezing temperature. Due to cost constraints, MON-3 was the oxidizer used during testing through 2018. In 2019, full scale hybrid testing with MON-25 commenced in Mojave, CA by Whittinghill Aerospace. One flight motor will be subjected to thermal cycling in a vacuum and later fired in a vacuum to demonstrate the proposed Liquid Injection Thrust Vector Control system performance at White Sands Test Facility (WSTF). In addition, there will be MON-25 characterization work done at Purdue University and WSTF. Additional testing of subscale and full scale motors will be conducted with MON-3 with fuel grain stress, fuel grain support and case design test objectives by Space Propulsion Group Inc. of Butte, MT. This paper documents some of the testing, issues and accomplishments with the MAV hybrid propulsion option that is being considered (along with a two-stage solid propulsion option).

Story, G. T.↗

JANNAF Rocket Engine Performance Test Data Acquisition and Interpretation Manual

Procedures recommended by the JANNAF Performance Standardization Working Group for acquisition and Interpretation of performance test data are presented. Included with the description of these procedures are recommended procedures covering the required measurements, associated instrumentation, calibration methods, and data uncertainties. In addition, criteria for the applicability of existing test data, the selection of test models, and analytical performance prediction improvement based on test results are outlined. Three sample cases using the recommended procedures are presented as an addendum under separate cover. Author

Evans, S. A.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of Eagle-Picher Industries, Incorporated 6.0 ampere-hour, nickel-cadmium spacecraft cells for separator material evaluation

Several groups of nickel cadmium cells were tested for the durability of their separator materials. The cells were rated at 6.0 ampere-hours, and contained double ceramic seals. Two cells in each group were fitted with pressure gauge assemblies. Results are presented for various brands of separator materials.

Harkness, J. D.↗

Improvement in surface fatigue life of hardened gears by high-intensity shot peening

Two groups of carburized, hardened, and ground spur gears that were manufactured from the same heat vacuum induction melted vacuum arc melted (VIM VAR) AISI 9310 steel were endurance tested for surface fatigue. Both groups were manufactured with a standard ground 16 rms surface finish. One group was subjected to a shot peening (SP) intensity of 7 to 9A, and the second group was subjected to a SP intensity of 15 to 17A. All gears were honed after SP to a surface finish of 16 rms. The gear pitch diameter was 8.89 cm. Test conditions were a maximum Hertz stress of 1.71 GPa, a gear temperature of 350 K, and a speed of 10000 rpm. The lubricant used for the tests was a synthetic paraffinic oil with an additive package. The following results were obtained: The 10 pct. surface fatigue (pitting) life of the high intensity (15 to 17A) SPed gears was 2.15 times that of the medium intensity (7 to 9A) SPed gears, the same as that calculated from measured residual stress at a depth of 127 microns. The measured residual stress for the high intensity SPed gears was 57 pct. higher than that for the medium intensity SPed gears at a depth of 127 microns and 540 pct. higher at a depth of 51 microns.

Townsend, Dennis P.↗

Ultra-high, resolution, modular optical angle encoder for space-based opto-mechanical applications

A 27-bit optical encoder using a novel patent pending technology has been developed by the MicroE Development Center of BEI Sensors & Systems Company and tested by the Sensor Systems Group (SSG) Inc., in a positioning and stabilization mirror assembly (PSMA) designed and constructed under a grant from the Marshall Space Flight Center. Test results verified performance within the specifications of the PSMA.

Luther, Holger↗

Body Composition of Rats on NASA Rodent Foodbar Versus Purina Lab Chow

The objective of this study is to test the nutritional adequacy of the NASA Rodent Foodbar for long term use for rats. The Foodbar was tested on two rat strains, Sprague Dawley and Fischer 344. Rats were fed either Foodbar or the control diet, Purina Chow #5012. Body composition analysis was performed on a selected number of samples (n=6 for each gender and treatment group) as part of extensive testing of the Foodbar. Water, fat, ash, and protein (and their percentages) for both treatment groups were compared. Sprague Dawley Foodbar fed rats had a lower % protein than Chow fed rats (25.8% vs. 30.0%). In addition, Sprague Dawley females fed Foodbar had higher total fat (42.1g vs. 24.6g) and % fat (16.4% vs. 10.5%), but lower % water (51.3% vs. 54.8%) than Sprague Dawley females fed Chow. Fischer 344 Foodbar fed rats had a lower % water (47.4% vs. 49,3%) and total water (93.2g vs. 99.6g). In addition, Fischer 344 Foodbar males had higher % fat (17.0% vs. 13.8%) and total fat (43.0g vs. 34.7g). The data suggests that body composition of Foodbar fed rats tends to have lower water content but a higher fat content compared to controls, but not all results are the same for different strains and even different genders within the same strains. The data obtained here, in addition to other data, helps provide a better understanding of the nutritional adequacy of the Foodbar and whether the formula may need to be modified.

Yu, Diane Sau Mun↗

Knee-Joint Proprioception During 30-Day 6 deg Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

To determine if daily isotonic exercise or isokinetic exercise training coupled with daily log proprioceptive training, would influence log proprioceptive tracking responses during Bed Rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a NO-Exercise (NOE) training control group (n = 5), and IsoTanic Exercise (ITE, n = 7) and IsoKinetic Exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min period / d, 5 d /week. Only the IKE group performed proprioceptive training using a now isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pro-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p less than 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9 +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.50, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both lsotonic exercise training (without additional propriaceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

Bernauer, E. M.↗

Knee-joint proprioception during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training

To determine if daily isotonic exercise or isokinetic exercise training coupled with daily leg proprioceptive training, would influence leg proprioceptive tracking responses during bed rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a no-exercise (NOE) training control group (n = 5), and isotonic exercise (ITE, n = 7) and isokinetic exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min periods.d-1, 5 d.week-1. Only the IKE group performed proprioceptive training using a new isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pre-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p < 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9* +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.5%, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both isotonic exercise training (without additional proprioceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

Controlled Clinical Trial↗

Estimation procedures to measure and monitor failure rates of components during thermal-vacuum testing

Estimation procedures are described for measuring component failure rates, for comparing the failure rates of two different groups of components, and for formulating confidence intervals for testing hypotheses (based on failure rates) that the two groups perform similarly or differently. Appendix A contains an example of an analysis in which these methods are applied to investigate the characteristics of two groups of spacecraft components. The estimation procedures are adaptable to system level testing and to monitoring failure characteristics in orbit.

Williams, R. E.↗

Performance and mood-state parameters during 30-day 6 degrees head-down bed rest with exercise training

The study was designed to determine if performance and mood impairments occur in bed-rested subjects, and if different exercise-training regimens modify or prevent them. Eighteen normal, healthy men were divided on the basis of age, peak oxygen uptake, and maximal isometric knee extension strength into three similar groups: no exercise (NOE), isotonic exercise (ITE), and isokinetic exercise (IKE). A 15-min battery of 10 performance tests and 8 mood and 2 sleep scales were administered daily during ambulatory control, 30 d of absolute bed rest (BR), and 4 d of ambulatory recovery. Performance test proficiency increased (p < 0.05) for all three groups during BR in 7 of 10 tests and there were no consistent significant differences between the three groups. However, during BR, the ITE group was distinguished from the other groups by a decline (p < 0.05) in the activation mood dimension and in two of its constituent scales (motivation and concentration), and by improvement (p < 0.05) in the trouble-falling-asleep and psychological-tension scales. Since few deleterious changes in performance and mood occurred in the three groups and did not exceed baseline ambulatory levels, we conclude that mood and performance did not deteriorate in response to prolonged BR and were not altered by exercise training. However, the decline in activation mood scales in the ITE group may reflect overtraining or excess total workload in this group.

NASA Center ARC↗

Tocopherol in Elder Self-Neglect

Although elder self-neglect is the most common form of elder mistreatment, its pathophysiology is not well understood. Alpha-tocopherol is a lipid soluble antioxidant required for the preservation of cell membranes. Since the association between tocopherol and cognitive impairment in older adults has been described, we explored the possibility of its role in elder self-neglect. OBJECTIVE: (1) To determine whether serum tocopherol levels are associated with elder self-neglect, and (2) to assess the association of serum tocopherol levels and cognitive function in elder self-neglect. METHODS: Serum tocopherol levels were measured in a cohort of 67 self-neglecting elders and 67 matched controls, recruited for the Consortium for Research in Elder Self-neglect of Texas. Pearson s correlation tests were performed to assess bivariate associations between serum tocopherol levels and cognitive function. RESULTS: Mean serum alpha-tocopherol levels were 10.8 +/- 4.7 ug/mL in self-neglect group and 13.0 +/- 4.9 ug/mL in control group (p = 0.006, unpaired student s t-test). None of the participants from either group had alpha-tocopherol level lower than the reference range. Mean serum gamma-tocopherol levels were 2.0 +/- 1.0 ug/mL in self-neglect group and 2.0 +/- 1.1 in control group (p=0.83). Proportion of the elders with gamma-tocopherol level lower than the reference range were 4.5% (3/66) in self-neglect group and 10.4% (7/67) in control group (p=0.32, Fisher s Exact Test). Among the self-neglecting elders, no association was found between serum alpha-tocopherol levels and the Mini-Mental State Examination (MMSE) or the Wolf-Klein Clock Drawing Test (CDT) scores (r =-0.42, p=0.75 for MMSE; r=0.08, p=0.54 for CDT). No association was found between serum gamma-tocopherol levels and the MMSE or the CDT (r=-0.12, p=0.35 for MMSE; r=0.05, p=0.68 for CDT). CONCLUSION: In our sample, neither alpha-tocopherol nor gamma-tocopherol appears to have a role in pathophysiology of elder self-neglect. Nevertheless, significantly lower serum alpha-tocopherol levels in the self neglect group merits further research.

Aung, K.↗

A computerized databank of decompression sickness incidence in altitude chambers

This report describes a hypobaric decompression sickness databank (HDSD) for use with personal computers. The databank consolidates some of the decompression sickness (DCS) information that has accumulated from altitude chamber tests from 1942 to the present. The information was transcribed to a data collection form, screened for accuracy and duplication, and then added to the databank through a computer keyboard. The databank consists of two files; 63 fields contain details of the test conditions in the altitude chamber, the outcome of the test in terms of DCS and venous gas emboli, the physical characteristics of the group of subjects who underwent the test, and the denitrogenation procedures prior to decompression. The HDSD currently contains 378 records that represent 130,012 altitude exposures from 80 sources: scientific journal articles, government and contractor reports, and chapters from books.

Conkin, Johnny↗