Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towards Improved Decision Making for the Smarter Grid: Geomagnetic Disturbance Implicit Modeling Uncertainty Quantification

Geomagnetic disturbances can greatly disrupt the power grid operation. This is caused by low-frequency changes in the earth’s magnetic field, which upon interaction with the deep earth conductivity induces a changing electric field at the earth’s surface. This in turn induces quasi-direct currents which have the potential to cause protective devices to operate, widespread damage to high-voltage transformers, or voltage collapse due to induced reactive power losses. While these impacts have been known since the 1940s, only recently have standards for GMD response been implemented. Because these standards are heavily based on models, it is important to understand when it is appropriate to make certain modeling assumptions. In this work, implicit modeling uncertainty is quantified for the purpose of enhanced decision making for disturbance impact mitigation. Considering electromagnetic models, modeling assumptions of non-uniform grounding, imbalanced operation, transformer saturation, and geomagnetically induced currents, voltage estimation values are analyzed. Statistical characteristics of modeling uncertainty are obtained by analysis of synthetically generated data. Results statistically characterize geomagnetic disturbances modeling uncertainty, providing an important tool for impact mitigation.

grid analysis↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Measurement-Based Approach for Inertia-Trend Analysis of the US Western Interconnection

Rising deployment of inverter-based resources (IBRs), characterized by a lack of rotating mass, is decreasing the total inertia of the system. This can lead to an increased Rate of Change of Frequency (RoCoF) during the disturbance and false activation of protective devices. There is a need to assess the inertia over the past decade amidst the evolving landscape of renewable energy sources to develop strategies for integrating energy storage, enhancing resilience measures, and ensuring the stable and reliable operation of the grid. Therefore, a realistic assessment of the inertia trend using a measurement-based approach that addresses the limitations of existing models is proposed. An inertia study of the Western Interconnection in the United States is performed utilizing the data from 2013 to 2022, obtained from FNET/ GridEye network. The three-second RoCoF time window is chosen for the study as it showed an optimum balance between a strong correlation with the power imbalance (ΔP) and minimum inclusion of primary response from governor. The obtained inertia trend result shows a small percentage declination of inertia over the decade. By examining the result alongside a generation mix graph, insights are gained into the dynamic interplay between shifting energy landscape and system inertia.

Dulal, Saurav↗

Omega-Limit Sets and Input-To-State Stability in Power Grids with Switching Equilibria

This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields - or modes -, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of ..omega.. -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Situational Awareness of Grid Anomalies (SAGA)

The modern power industry becomes more vulnerable to cyber events due to the growing interconnectivity, interdependence, and complexity of the electric power grid. High-fidelity modeling and simulation tools that support the preventative risk analysis on potential cyber-relevant events is essential for ensuring the situational awareness of the system operator as it provides an inexpensive and risk-free environment to test the system responses under various cyber-relevant events and hereby can support research on cyber anomaly detection, optimal protective resource allocation, and mitigation measures. In this webinar, we will share NREL's cybersecurity research capabilities by highlighting the development of a scalable cyber-physical event test bed and demonstration with real hardware in the loop. The developed cyber-physical event test bed is backboned by an integrated transmission, distribution, and communication dynamic co-simulation framework and a plug-and-play cyber event generation module. It is designed to be modular and compatible with parallel computing, and thereby supports large-scale system simulations at an affordable computation cost. The test bed can capture millisecond-to-minutes dynamic frequency and voltage responses under cyber events from the bulk transmission system to the active distribution systems and distributed energy resources at the grid edge.

co-simulation↗

Intel® DOE Grid Security Enhancement Security in Power System Edge. Final Technical Report

Intel® and its partners, Schneider Electric and LiveData Utilities, were tasked by Department of Energy to explore solutions in two areas of grid security. One, secure the existing communication network and the legacy devices with minimal disruption to the infrastructure, and second, to develop capabilities in semiconductor chips such that they come with built-in security to order to provide secure communication and protection from cyberattacks with minimal effort from operation technology (OT) application developers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (medium-voltage) level may also become common as a means for improving distribution reliability and resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods, systems, and computer readable media for protecting and controlling a microgrid with a dynamic boundary

Methods, systems, and computer readable mediums for protecting and controlling a microgrid with a dynamic boundary are disclosed. One method includes detecting a fault in a microgrid that includes a dynamic point-of-common-coupling (PCC), in response to determining that the microgrid is operating in a grid-connected mode, isolating the fault by tripping a microgrid side smart switch and a grid side smart switch that are located immediately adjacent to the fault, initiating the reclosing of the grid side smart switch, and initiating the reclosing for the microgrid side smart switch via resynchronization if the grid side smart switch is successfully reclosed, and in response to determining that the microgrid is operating in an islanded mode, isolating the fault by tripping a microgrid side smart switch that is located immediately adjacent to the fault, and initiating the reclosing of the microgrid side smart switch.

Wang, Fei↗

NEFTSec: Networked federation testbed for cyber-physical security of smart grid: Architecture, applications, and evaluation

As today's power grid is evolving into a densely interconnected cyber-physical system (CPS), a high fidelity and multifaceted testbed environment is needed to perform cybersecurity experiments in a realistic grid environment. Traditional standalone CPS testbeds lack the ability to emulate complex cyber-physical interdependencies between multiple smart grid domains in a real-time environment. Therefore, there are ongoing research and development (R&D) efforts to develop an interconnected CPS testbed by sharing geographically dispersed testbed resources to perform distributed simulation while analysing simulation fidelity. This paper presents a networked federation testbed for cybersecurity evaluation of today's and emerging smart grid environments. Specifically, it presents two novel testbed architectures, including cyber federation and cyber-physical federation, identifies R&D applications, and also describes testbed building blocks with experimental case studies. It also presents a novel co-simulation interface algorithm to facilitate distributed simulation within cyber-physical federation. The resources available at the PowerCyber CPS security testbed at Iowa State University (ISU) and the US Army Research Laboratory are utilised to develop this platform for performing multiple experimental case studies pertaining to wide-area protection and control applications in power system. Finally, experimental results are presented to analyse the simulation fidelity and real-time performance of the testbed federation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Resource Adequacy and Community Impacts of an Evolving Grid: Considerations for State Regulators

As U.S. power systems continue to decarbonize, state regulators must be able to broadly assess the cost and reliability implications of proposed fossil retirements and the corresponding resources that are coming online to replace them. Specifically, regulators must evaluate whether proposed infrastructure investments are sufficient to ensure the long-term reliability of the system, while also protecting rate payers by ensuring that such investments are necessary and not excessive. Broadly speaking, this objective is typically framed in terms of maintaining long-term resource adequacy at the lowest cost, while also ensuring that other social and/or environmental objectives are satisfied. System planners currently have a host of sophisticated analytical tools at their disposal to evaluate the cost-benefit trade-offs of different approaches to ensuring resource adequacy. However, most of these tools and associated metrics were designed with traditional power systems in mind. Over the past decade, it has become increasingly clear that the metrics and models that have reliably assessed resource adequacy in systems dominated by large thermal and hydropower resources will be insufficient for systems with significant contributions from emerging technologies such as wind, solar and storage. Therefore, in recent years many new metrics and modeling approaches have been developed, and are increasingly being implemented, to meet the needs of the clean energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Rock Pool Hydroperiod Fluctuation using Climate Variables to Inform Habitat Monitoring and Protection in the Western Sonoran Desert

As warming and drying trends continue to impact the greater American Southwest, effective ecosystem management increasingly relies upon understanding the relationships between climate and water resources. Ephemeral freshwater rock pools, known as tinajas, have great ecological and cultural importance as some of the only sources of surface water in the western Sonoran Desert (WSD). Tinaja flooding and drying cycles, known as hydroperiods, vary based on meteorologic and climatologic conditions; however, a lack of extensive research relating climatic impacts to tinajas puts these critical ecosystems further at risk. Tinajas throughout the WSD are monitored by the National Park Service (NPS) using resource intensive strategies including in situ trail camera observation and direct measurement. To aid NPS monitoring efforts, this research used remotely sensed climate data to analyze spatiotemporal climate trends and relationships between climate variables and tinaja hydroperiods in the WSD between 1979–2022. Using Aqua and Terra Moderate Resolution Imaging Spectroradiometers (MODIS), University of Idaho Gridded Surface Meteorological Dataset (gridMET), and OpenET data, the project analyzed land surface temperature, evapotranspiration, precipitation, wind velocity, and solar radiation. The team generated climate anomaly time series and climate normal maps for the WSD, identifying statistically significant spatial and temporal trends. These data were then compared to daily, qualitative in situ hydroperiod observations taken between 2019–2022. This work will be used by the NPS to inform the monitoring and protection of tinajas in the WSD. Findings contribute to a limited body of research concerning climate and tinajas, which are often overlooked despite their disproportionate ecological importance.

Annie Britton↗

cerf: A Python package to evaluate the feasibility and costs of power plant siting for alternative futures

Long-term electric power sector planning and capacity expansion is a key area of interest to stakeholders across a wide range of organizations because it helps in making informed decisions about investments in infrastructure within the context of potential future vulnerabilities under various natural and human stressors. Future power plant siting costs will depend on a number of factors including the characteristics of the electricity capacity expansion and electricity demand (e.g., fuel mix of future electric power capacity, and the magnitude and geographic distribution of electricity demand growth) as well as the geographic location of power plants. Electricity technology capacity expansion plans modeled to represent alternate future conditions meeting a set of scenario assumptions are traditionally compared against historical trends which may not be consistent with current and future conditions. We present the `cerf` Python package (a.k.a., the Capacity Expansion Regional Feasibility model) which helps evaluate the feasibility and structure of future, scenario-driven electricity capacity expansion plans by siting power plants in areas that have been deemed the least cost option while considering dynamic future conditions. We can use `cerf` to gain insight to research topics such as: 1) under what conditions future projected electricity expansion plans from models such as GCAM-USA are possible to achieve, 2) where and which on-the-ground barriers to siting (e.g., protected areas, cooling water availability) may influence our ability to achieve certain expansions, and 3) how electricity infrastructure build-outs and value may evolve into the future when considering locational marginal pricing (LMP) based on the supply and demand of electricity from a grid operations model.

20 FOSSIL-FUELED POWER PLANTS↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗