Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “generator parameter estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Planck 2013 results. XXII. Constraints on inflation

We analyse the implications of the Planck data for cosmic inflation. The Planck nominal mission temperature anisotropy measurements, combined with the WMAP large-angle polarization, constrain the scalar spectral index to be n s = 0.9603 ± 0.0073, ruling out exact scale invariance at over 5σ. Planck establishes an upper bound on the tensor-to-scalar ratio of r< 0.11 (95% CL). The Planck data thus shrink the space of allowed standard inflationary models, preferring potentials with V "< 0. Exponential potential models, the simplest hybrid inflationary models, and monomial potential models of degree n = 2 do not provide a good fit to the data. Planck does not find statistically significant running of the scalar spectral index, obtaining d n s /dlnk =-0.0134 ± 0.0090. Here, we verify these conclusions through a numerical analysis, which makes no slow-roll approximation, and carry out a Bayesian parameter estimation and model-selection analysis for a number of inflationary models including monomial, natural, and hilltop potentials. For each model, we present the Planck constraints on the parameters of the potential and explore several possibilities for the post-inflationary entropy generation epoch, thus obtaining nontrivial data-driven constraints. We also present a direct reconstruction of the observable range of the inflaton potential. Unless a quartic term is allowed in the potential, we find results consistent with second-order slow-roll predictions. We also investigate whether the primordial power spectrum contains any features. We find that models with a parameterized oscillatory feature improve the fit by Δχ 2 eff &approx; 10 ; however, Bayesian evidence does not prefer these models. We constrain several single-field inflation models with generalized Lagrangians by combining power spectrum data with Planck bounds on f NL . Planck constrains with unprecedented accuracy the amplitude and possible correlation (with the adiabatic mode) of non-decaying isocurvature fluctuations. The fractional primordial contributions of cold dark matter (CDM) isocurvature modes of the types expected in the curvaton and axion scenarios have upper bounds of 0.25% and 3.9% (95% CL), respectively. In models with arbitrarily correlated CDM or neutrino isocurvature modes, an anticorrelated isocurvature component can improve the χ 2 eff by approximately 4 as a result of slightly lowering the theoretical prediction for the &ell; ≳ 40 multipoles relative to the higher multipoles. Nonetheless, the data are consistent with adiabatic initial conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Stark broadening measurement of the electron density in an atmospheric pressure argon plasma jet with double-power electrodes

Characteristics of a double-power electrode dielectric barrier discharge of an argon plasma jet generated at the atmospheric pressure are investigated in this paper. Time-averaged optical emission spectroscopy is used to measure the plasma parameters, of which the excitation electron temperature is determined by the Boltzmann's plot method whereas the gas temperature is estimated using a fiber thermometer. Furthermore, the Stark broadening of the hydrogen Balmer H{sub {beta}} line is applied to measure the electron density, and the simultaneous presence of comparable Doppler, van der Waals, and instrumental broadenings is discussed. Besides, properties of the jet discharge are also studied by electrical diagnosis. It has been found that the electron densities in this argon plasma jet are on the order of 10{sup 14} cm{sup -3}, and the excitation temperature, gas temperature, and electron density increase with the applied voltage. On the other hand, these parameters are inversely proportional to the argon gas flow rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE MASS OF THE MILKY WAY AND M31 USING THE METHOD OF LEAST ACTION

We constrain the most likely range of masses for the Milky Way (MW) and M31 using an application of the numerical action method (NAM) that optimizes the fit to observed parameters over a large ensemble of NAM-generated solutions. Our 95% confidence level mass ranges, 1.5-4.5 × 10{sup 12} M{sub ☉} for MW and 1.5-5.5 × 10{sup 12} M{sub ☉} for M31, are consistent with the upper range of estimates from other methods and suggests that a larger proportion of the total mass becomes detectable when the peculiar motions of many nearby satellites are taken into account in the dynamical analysis. We test the method against simulated Local Group catalogs extracted from the Millennium Run to confirm that mass predictions are consistent with actual galaxy halo masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Matched filtering and parameter estimation of ringdown waveforms

Using recent results from numerical relativity simulations of nonspinning binary black hole mergers, we revisit the problem of detecting ringdown waveforms and of estimating the source parameters, considering both LISA and Earth-based interferometers. We find that Advanced LIGO and EGO could detect intermediate-mass black holes of mass up to {approx}10{sup 3}M{sub {center_dot}} out to a luminosity distance of a few Gpc. For typical multipolar energy distributions, we show that the single-mode ringdown templates presently used for ringdown searches in the LIGO data stream can produce a significant event loss (>10% for all detectors in a large interval of black hole masses) and very large parameter estimation errors on the black hole's mass and spin. We estimate that more than {approx}10{sup 6} templates would be needed for a single-stage multimode search. Therefore, we recommend a ''two-stage'' search to save on computational costs: single-mode templates can be used for detection, but multimode templates or Prony methods should be used to estimate parameters once a detection has been made. We update estimates of the critical signal-to-noise ratio required to test the hypothesis that two or more modes are present in the signal and to resolve their frequencies, showing that second-generation Earth-based detectors and LISA have the potential to perform no-hair tests.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of aggregate building thermal dynamic model and unmeasured internal heat load from data

This paper is on the problem of simultaneously identifying the parameters of an aggregate thermal dynamic model of a multi-zone building and unknown disturbances from input-output data. An aggregate model is a single-zone equivalent of a multi-zone building, and is useful for many purposes, including model based control of large heating, ventilation and air conditioning (HVAC) equipment that delivers thermal energy to the entire building. A key challenge in identification is the presence of unknown disturbance since it is not measurable but non-negligible.We first present a principled method to aggregate a multizone building model into a single zone model. We then provide a method to identify thermal parameters and the unknown disturbance for this aggregate (single-zone) model. Finally, we test our proposed identification algorithm to data generated from a virtual building. A key insight provided by the aggregation method allows us to recognize under what conditions the estimation of the disturbance signal will be necessarily poor and uncertain.

Guo, Zhong↗

Application of Kalman Filter to Improve Model Integrity for Securing Electricity Delivery

Power system model integrity is essential to many planning and operation tasks to ensure the safety and reliability of electricity delivery. Inaccurate system models would result in unreliable assessment of system security conditions and cause large-scale blackouts such as the 2003 Northeast Blackout. This dictates a strong need for model calibration and verification, which should be done periodically and preferably, in an automatic manner. Our previous work has demonstrated the feasibility of applying Extended Kalman Filter (EKF) to calibrate generator parameters using disturbance data recorded by phasor measurement units (PMU). This paper proposes to use Riccati equation to investigate EKF’s performance, especially regarding parameter identifiability. The covariance, which can be derived from the Riccati equation, offers insight into the uncertainties of parameters estimated by the EKF-based method. Simulation results show the effectiveness of the proposed approach.

calibration↗

Identification and assignment of rotational spectra using artificial neural networks

A method of identifying molecular parameters may include receiving observed transition frequencies, generating transition frequency sets and a spectral parameter sets, training one or more artificial neural networks by analyzing the transition frequency sets and the spectral parameter sets, analyzing the observed transition frequencies using the one or more trained artificial neural networks to predict estimated spectral parameters, and identifying molecular parameters by analyzing the estimated spectral parameters. A molecular parameter identification system may include a rotational spectrometer, a user interface, and a spectrum analysis application that may retrieve observed transition frequencies, identify a Hamiltonian type by a neural network analyzing the observed transition frequencies, select a second trained artificial neural network based on the identified Hamiltonian type, analyze observed transition frequencies using the second artificial neural network to identify estimated spectral parameters, and identify molecular parameters.

Prozuments, Kirills↗

A modified Monte Carlo 'local importance function transform' method

The Local Importance Function Transform (LIFT) method uses an approximation of the contribution transport problem to bias a forward Monte-Carlo (MC) source-detector simulation [1-3]. Local (cell-based) biasing parameters are calculated from an inexpensive deterministic adjoint solution and used to modify the physics of the forward transport simulation. In this research, we have developed a new expression for the LIFT biasing parameter, which depends on a cell-average adjoint current to scalar flux (J{sup *}/{phi}{sup *}) ratio. This biasing parameter differs significantly from the original expression, which uses adjoint cell-edge scalar fluxes to construct a finite difference estimate of the flux derivative; the resulting biasing parameters exhibit spikes in magnitude at material discontinuities, causing the original LIFT method to lose efficiency in problems with high spatial heterogeneity. The new J{sup *}/{phi}{sup *} expression, while more expensive to obtain, generates biasing parameters that vary smoothly across the spatial domain. The result is an improvement in simulation efficiency. A representative test problem has been developed and analyzed to demonstrate the advantage of the updated biasing parameter expression with regards to solution figure of merit (FOM). For reference, the two variants of the LIFT method are compared to a similar variance reduction method developed by Depinay [4, 5], as well as MC with deterministic adjoint weight windows (WW). (authors)

97 MATHEMATICS AND COMPUTING↗

Electrical Infrastructure Cost Model for Marine Energy Systems

The National Renewable Energy Laboratory's Electrical Infrastructure Cost Model is an Excel-based tool designed to estimate the electrical infrastructure costs of marine energy components and subsystems. It incorporates data collected from offshore wind projects, utility projects, and other relevant sources to provide accurate and comprehensive cost projections. With its user-friendly interface, the model allows users to input various parameters related to the system array, electrical cables, and substations. By leveraging industry data, cost trends, and technological advancements, the model generates outputs that include system array sizing, electrical cable specifications and costs, substation specifications and costs, and total electrical infrastructure costs. One of the notable strengths of the model is its flexibility in covering multiple-orders-of-magnitude scaled systems, accommodating projects ranging from proof-of-concept or pilot-scale installations to large-scale offshore systems. By collecting data largely from offshore wind reports and utility projects, the model incorporates real-world conditions and accounts for industry-specific factors. It incorporates cost trends and sizing relationships to deliver cost estimations for electrical infrastructure components, such as electrical cables and substation equipment.

16 TIDAL AND WAVE POWER↗

Data-Driven Model Validation Across Dimensions

Data-driven model validation across dimensions in mathematical and computational biology assumptions are often made (e.g., symmetry) to reduce the problem from three spatial dimensions (3D) to two (2D). However, some experimental datasets, such as cell counts obtained via flow cytometry, represent the entire 3D biological object. For purpose of model calibration and validation, it is sometimes necessary to compare these biological datasets with model outputs. In this work, we propose a methodology for scaling 2D model outputs to compare with 3D experimental datasets, and we discuss the application of this methodology to two examples: agent-based models of granuloma formation and skeletal muscle tissue. The accuracy of the method is evaluated in artificially generated scenarios.

97 MATHEMATICS AND COMPUTING↗

Nuclear data uncertainty propagation applied to the versatile test reactor conceptual design

We report the Versatile Test Reactor (VTR) currently under development is a 300 MWth sodium-cooled fast reactor (SFR) fueled with ternary metal alloy fuel, which aims to accelerate the testing of advanced nuclear fuels, materials, instrumentation, and sensors in high flux environments that are necessary to license the next generation of advanced reactor concepts. To support the VTR design process, uncertainties associated with the nuclear data has been propagated through the reactor core neutronics calculation to global parameters of interest, such as the core multiplication factor, kinetic parameters, and various reactivity feedback coefficients, following the sensitivity based uncertainty propagation approach. By folding the sensitivity coefficients, separately computed by the generalized perturbation theory code PERSENT and Monte Carlo code Serpent 2, with the variance-covariance matrices from COMMARA-2.0, we obtain the reaction-wise, isotope-wise, and overall uncertainties for each response of interest due to nuclear data uncertainty. With Serpent 2, the statistical error of the uncertainty is obtained by propagating the statistical error of the sensitivity coefficients through the same process using a newly developed uncertainty propagation method. From both codes, the overall top uncertainty contributors are found to be the cross section of Fe-56 elastic scattering, Na-23 elastic scattering, and U 238 inelastic scattering. The large contributions of the Fe-56 elastic scattering cross sections to global parameters are due to its relatively large relative uncertainty of 5–10% in nuclear data and the large volume of Fe-containing reflector assemblies in the fairly compact VTR core design. Both codes agreed well for the overall uncertainty estimates of all responses of interest, except the delayed neutron fraction, prompt neutron generation time, and the coolant density feedback coefficient, where Serpent 2 yielded a much larger value than PERSENT due to the large statistical error of sensitivity coefficients. The calculated uncertainties are also compared to those associated with other SFR cores. Another outcome of this study is a variance-covariance matrix of reactivity coefficients, which can be used in the subsequent uncertainty propagation to the system level to investigate the impact of identified uncertainties on system responses in the safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NUMERICAL MODELING OF CATHODE CONTACT MATERIAL DENSIFICATION

Numerical modeling was used to simulate the constrained sintering process of the cathode contact layer during assembly of solid oxide fuel cells (SOFCs). A finite element model based on the continuum theory for sintering of porous bodies was developed and used to investigate candidate low-temperature cathode contact materials. Constitutive parameters for various contact materials under investigation were estimated from dilatometry screening tests, and the influence of processing time, processing temperature, initial grain size, and applied compressive stress on the free sintering response was predicted for selected candidate materials. The densification behavior and generated stresses within a 5-cell planar SOFC stack during sintering, high temperature operation, and room temperature shutdown were predicted. Insufficient constrained densification was observed in the stack at the proposed heat treatment, but beneficial effects of reduced grain size, compressive stack preload, and reduced thermal expansion coefficient on the contact layer densification and stresses were observed.

30 DIRECT ENERGY CONVERSION↗

Design optimization of MR-compatible rotating anode x-ray tubes for stable operation

Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes.Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×10{sup 5}–5×10{sup 7} N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz.Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×10{sup 5} N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×10{sup 7} N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×10{sup 6} N/m).Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization performance, fidelity, and cost: SIAM VQE

This dataset contains files storing results from classically-simulated quantum subroutines within a dynamical mean-field theory workflow, and jupyter notebooks processing the data in these files to generate plots. The files store: (1) Results from variational quantum eigensolver (VQE) simulations searching for optimal parameters allowing parametrized quantum circuits to prepare approximations to ground states of different Anderson impurity models (AIMs) (2) Results from simulations of a quantum Lanczos algorithm (QLA) estimating the Lanczos coefficients defining the continued-fraction representation of an (AIM) Green’s function Description: Any file named vqe_gs_results* stores approximations to the ground state and energy of a given AIM estimated using three different methods: (1) Numerical diagonalization (2) Ideal VQE simulation (3) VQE simulation with sampling noise For each VQE simulations metadata about the optimization (optimization results plus number of quantum circuits that would have been executed on real hardware) is also stored. Any file named qla_dos_results* estimations for the Lanczos coefficients defining the Green’s function of an AIM. The stored estimations are achieved using different methods: (1) Numerical Lanczos algorithm from initial states obtained from numerical diagonalization (2) Simulated quantum Lanczos algorithm from initial states prepared from parametrized quantum circuits yielded by corresponding ideal and noisy VQE subroutines. The dataset is used and described in M. Karabin et al., "Quantum solver for single-impurity Anderson models with particle-hole symmetry", Phys. Rev. Research 8, 033066 (2026). DOI: https://doi.org/10.1103/7ys3-tl4l

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hysteresis Effects on a Non-uniform Transmission Line with Induced Quantum Mechanical Atomic Transitions

This study describes the effect of hysteresis on the generation of the higher harmonics in the line voltage and current in a non-uniform transmission line when we include a quadratic non-linear term having memory to account for the hysteresis effect in the inductance part of line. The simulational analysis using MATLAB is presented which works with a non-uniform line having hysteresis. These simulations are based on a theoretical spatial Fourier analysis combined with perturbation theory which is used without bothering about source and load. The line differential equations are solved approximately in the space- time-frequency domain using perturbation theory and the numerical computations have been carried out for the voltage and current amplitude characteristics. In Appendix 1, some theoretical explanations that support our non-linear memory-based hysteresis model based on Landau’s equation of precession of a magnetic moment in a magnetic field are included. This paper also includes a brief derivation of atomic transition probability produced by e-m radiation from the transmission line falling on an atom in the far field zone. This calculation enables us to derive maximum likelihood estimation(MLE) of the hysteresis parameters by measuring which atomic transitions have occurred.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of pure and mixed clustered noble gas puffs irradiated with a high intensity (7 × 10 19 W/cm 2 ) sub-ps laser beam and achievement of a strong X-ray flash in a laser-generated debris-free X-ray source

We present a broad study of linear, clustered, noble gas puffs irradiated with the frequency doubled (527 nm) Titan laser at Lawrence Livermore National Laboratory. Pure Ar, Kr, and Xe clustered gas puffs, as well as two mixed-gas puffs consisting of KrAr and XeKrAr gases, make up the targets. Characterization experiments to determine gas-puff density show that varying the experimental parameter gas-delay timing (the delay between gas puff initialization and laser-gas-puff interaction) provides a simple control over the gas-puff density. X-ray emission (>1.4 keV) is studied as a function of gas composition, density, and delay timing. Xe gas puffs produce the strongest peak radiation in the several keV spectral region. The emitted radiation was found to be anisotropic, with smaller X-ray flux observed in the direction perpendicular to both laser beam propagation and polarization directions. The degree of anisotropy is independent of gas target type but increases with photon energy. X-ray spectroscopic measurements estimate plasma parameters and highlight their difference with previous studies. Electron beams with energy in excess of 72 keV are present in the noble gas-puff plasmas and results indicate that Ar plays a key role in their production. Finally, a drastic increase in harder X-ray emissions (X-ray flash effect) and multi-MeV electron-beam generation from Xe gas-puff plasma occurred when the laser beam was focused on the front edge of the linear gas puff.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Use of Hyperpolarized Helium MRI for Conformal Avoidance Lung Radiotherapy

We wanted to illustrate the feasibility of using hyperpolarized helium magnetic resonance imaging (HPH-MRI) to obtain functional information that may assist in improving conformal avoidance of ventilating lung tissue during thoracic radiotherapy. HPH-MRI images were obtained from a volunteer patient and were first fused with a proton density-weighted (PD{sub w}) MRI to provide corresponding anatomic detail; they were then fused with the treatment planning computed tomography scan of a patient from our treatment planning database who possessed equivalent thoracic dimensions. An optimized treatment plan was then generated using the TomoTherapy treatment planning system, designating the HPH-enhancing regions as ventilation volume (VV). A dose-volume histogram compares the dosimetry of the lungs as a paired organ, the VV, and the lungs minus the VV. The clinical consequences of these changes was estimated using a bio-effect model, the parallel architecture model, or the local damage (f{sub dam}) model. Model parameters were chosen from published studies linking the incidence of grade 3+ pneumonitis, with the dose and volume irradiated. For two hypothetical treatment plans of 60 Gy in 30 fractions delivered to a right upper-lobe lung mass, one using and one ignoring the VV as an avoidance structure, the mean normalized total dose (NTD{sub mean}) values for the lung subvolumes were: lungs = 12.5 Gy{sub 3}vs. 13.52 Gy{sub 3}, VV = 9.94 Gy{sub 3}vs. 13.95 Gy{sub 3}, and lungs minus VV = 16.69 Gy{sub 3}vs. 19.16 Gy{sub 3}. Using the f{sub dam} values generated from these plans, one would predict a reduction of the incidence of grade 3+ radiation pneumonitis from 12%-4% when compared with a conventionally optimized plan. The use of HPH-MRI to identify ventilated lung subvolumes is feasible and has the potential to be incorporated into conformal avoidance treatment planning paradigms. A prospective clinical study evaluating this imaging technique is being developed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗