Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “furnaces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Mercury Speciation During Vitrification of LAW

n this work, laboratory and engineering-scale tests were conducted that mimic the reactive environment of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) low activity waste (LAW) melter and off-gas system in order to assess the speciation of mercury at select points in the processing system. The experimental protocols, test equipment, feed materials used, and rationale for testing are detailed in the Test Plan for this work. Particular attention was paid to the amount and speciation of mercury in submerged bed scrubber (SBS) solutions, which are intended to be recycled back to the melter feed at the WTP. Results are presented from detailed mercury analysis of these solutions using Environmental Protection Agency (EPA) Method 1630 and modifications to this method for dimethyl mercury and methyl mercury as well as EPA Method 1631 and modifications to this method for total, dissolved, elemental, suspended, and ionic mercury. Testing was conducted in two separate sets of experiments: (1) One set of tests (crucible-scale furnace tests) that involved heating small batches of mercury-spiked melter feed in crucibles to determine the amount of mercury retained in the glass and the species of mercury in the exhaust gases; (2) A second set of tests (DM10 melter tests) was planned that involved creating LAW melter plenum gas compositions using the DM10 melter system, injecting mercury into the off-gas stream, and passing that stream though a reactor that simulates various plenum gas conditions. Operational issues led to the need to use one of the VSL DM100 melters in place of the planned DM10 melter for these tests. The speciation of mercury after exposure to those conditions was monitored. In both sets of tests, the exhaust gases were run through a scrubber that was intended to mimic the LAW SBS in order to determine how much of the mercury exiting the melter would be retained in the primary off-gas system fluids and in what form. After passing through the SBS, the exhaust stream was analyzed to determine particulate, ionic, elemental, and total mercury passing downstream of the SBS. In tests employing gases derived from the DM100 melter that were spiked with elemental mercury, the processing system provided gas temperatures and residence times that are representative of the WTP LAW vitrification system in order to assess the effect of those conditions on mercury speciation. The Decontamination Factor (DF) across the system in the tests with mercury-spiked DM100 melter exhaust was determined using the analytical data from EPA Method 30B (Fluegas Adsorption Mercury Speciation (FAMS TM )) exhaust samples and the amount of mercury detected in the SBS solutions. Mercury species used in melter feed crucible scale tests were divalent (chloride and iodide), monovalent (chloride and fluoride), and elemental mercury. Individual tests included only a single form of mercury in the feed. The results for total mercury mass balances in the crucible tests are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fundamental R&D for high-Q0 650 MHz SRF cavities for hadron linacs

Upcoming projects requiring high-Q0 ~650 MHz elliptical cavities, such as MSU’s Facility for Rare Isotope Beams’ energy upgrade and Fermilab’s PIP-II, drive a need to better understand RF losses due to magnetic flux. With sample sets from two different Niobium vendors, we explore the efficacy of the fast-cooldown method, and high- temperature annealing in promoting flux expulsion. Additionally, we report the results of vertical tests comparing the effect of electropolishing and furnace baking treatments on the cavity flux sensitivity. We also directly measure the flux pinning force in niobium samples, and correlate it with different heat treatments, and flux expulsion performance.

K.McGee, K.McGee↗

Catalyzing the Mass Adoption of High Efficiency Technologies in the Multifamily Housing Market

ICAST’s objective was to catalyze the adoption of very-high-efficiency (VHE) heat pump HVAC (mini-splits) and water heaters (HPWH) in multifamily (MF), especially affordable housing (MFAH). Nationally, the market penetration of ENERGY STAR-certified ASHPs is estimated at 43%, and for HPWHs it’s 3% (ENERGY STAR, 2022). Note that mini-splits are a much more practical choice for MF units than ducted systems and their adoption is only a portion of the number provided above, but isolating the market penetration data for mini-split systems is difficult. Both the heat pump-based HVAC and water heater systems can be approx. three times more efficient than their conventional counterparts for space and water heating. While awareness and adoption of VHE heat pumps has been growing nationally, and electric heat pump systems have outsold gas furnaces for two years in a row, the MF segment continues to lag behind single-family. MF constitutes almost a third of the housing in the U.S., so scaling up VHE adoption in this segment can assist in achieving critical climate change goals, while preserving housing affordability for the low-to-moderate income (LMI) population (historically, 85% of residents of MF are LMI).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY23 Status of Quality Assurance Plan for Out-of-Pile Test Data

The DOE Advanced Reactor Technology program has supported recovery and preservation of legacy metallic fuel data collected as part of the US fast reactor program, recognizing it as essential to development and licensing activities for advanced fast reactors. Databases were established as organized collections of experimental records and data generated from in-pile experiments at EBRII, FFTF, and TREAT as well as related out-of-pile examinations of irradiated fuels. The Out-of-Pile Transient Database (OPTD), includes records of over 150 out-of-pile furnace transient tests on metallic fuels conducted at Argonne’s Alpha-Gamma Hot Cell Facility to evaluate their transient performance and characterize fuel/cladding interaction. The database is accessible to registered users from US universities, laboratories, and nuclear industry. Because the data in OPTD has not been formally qualified, its applicability and ability to support licensing activities is limited. This report outlines progress and plans to quality assure data in OPTD, maximizing its impact for model validation and verification as well as qualification of fuels for safe and effective use in advanced reactor designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding the field and frequency dependence of rf loss in SRF cavities

SRF cavities subjected to heat treatment below 200 °C in the presence of nitrogen showed an improvement in quality factor while maintaining an accelerating gradient above 25 MV/m. Here, we report the rf performance of several single-cell superconducting radio frequency cavities with frequency ranging from 0.75 - 3.0 GHz subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 - 175 oC for 24 - 48 hours in low partial pressure of ultra-pure nitrogen gas. The improvement in Q? with Q-rise was observed when nitrogen gas was injected ~300 °C during the furnace treatment. The surface modification was confirmed by the change in electronic mean free path and near surface elemental analysis by SIMS. The field dependence of the rf losses is strongly correlated to the cavity frequency. The analysis of experimental data with available theoretical models as well as comparison with similar study on high temperature nitrogen doped cavities will be presented.

Ciovati, Gianluigi↗

Abstract for CRADA between National Energy Technology Laboratory and United States Steel Corporation

The United States Department of Energy’s National Energy Technology Laboratory (DOE-NETL) is committed to developing practical carbon capture solutions for reducing CO2 emissions from fossil fueled industrial sources, including steel manufacturing, cement manufacturing, and others. To address this need, NETL has developed a new ultra-high permeance polymer membrane that is optimized to reduce the cost of post-combustion carbon capture. NETL will partner with the U. S. Steel to demonstrate the effectiveness of this gas separation membrane technology using waste gas from a blast furnace at a steel production plant. Systems analysis will be conducted to understand the potential benefits for full scale implementation of the technology for steel manufacturing.

36 MATERIALS SCIENCE↗

Uranium Processing Signatures for Nuclear Forensics (NA22 End of FY23 Report)

A vacuum induction melting (VIM) furnace was used to produce an ~120 kg depleted uranium (DU) rod in November 2021 from well characterized feedstock to investigate the separation of thorium (Th) and protactinium (Pa) from uranium (U) during U metal casting and quantify the behavior of the 230 Th/ 234 U and 231 Pa/ 235 U radiochronometry systems. This work suggested that while 234 Th, measured by gamma spectrometry, appears to segregate to the top and surface of the rod, the concentration of 230 Th determined by isotope dilution mass spectrometry (IDMS) in drill turnings from multiple locations in the rod, including the hot top, is relatively consistent. To evaluate whether Th is potentially enriched at only the very outer surface of the cast DU rod relative to the bulk material in the cast rod, thin surface samples were collected from the cast DU rod. Locations sampled included the inner diameter (ID) and outer diameter (OD) of the bottom of the casting and the ID, OD, and top face of the hot top (very top of the casting). The locations are shown in Figure 1. Four samples were taken from each location at different depths in the cast material. Each cut took approximately 0.03 – 0.05” off of the casting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Differential Scanning Calorimetry Calibration and Heat Capacity

The Differential Scanning Calorimeter(DSC) is used to find multiple properties ofmaterials such as heat capacity, melting points, crystallization, and more. Fermilabowns the NETZSCH DSC 404 F3 Pegasus to test novel material for a high poweredtargetry components. The DSC heats up to 1500 C, uses a platinum furnace, and Al 2 O 3 crucibles. In order for the DSC to produce consistent and correct data,calibration of the machine was necessary. Testing with the given calibration kit ofknown metals. Once calibrated, testing on novel materials for their specific heatcapacity ensues.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Integrated Approach to Predicting Ash Deposition and Heat Transfer in Coal-Fired Boilers

The overall goal of this project is to develop via measurements and simulations an advanced online technology to predict, monitor and manage fireside ash deposition in a coal-fired boiler allowing for more efficient operations under a range of load conditions and fuel property variability. With this in place fuel sorting and blending can be done upstream and operations can be optimized to compensate for load and fuel properties. In support of this objective, three experimental campaigns were undertaken during the course of the project to measure ash deposition rates within the boiler at different fuel flow rates and its ash composition variability. Simulations of the experimental conditions representing actual geometry, operational scenarios in terms of air flow rates, coal flow rates as well as coal compositions, heating values, and particle size distributions were also carried out. Deposition rates were predicted using a unique particle kinetic energy and viscosity based ash deposition methodology whose validity was ascertained by comparing against deposition rate measurements for widely varying operating conditions and ash compositions in a lab-scale furnace. With a unique end-to-end combustion modeling methodology established and different simulation scenarios carried out, the results from our computational fluid dynamic (CFD) simulations in conjunction with the plant data summarized in this report were used to refine Microbeam Technology Incorporated’s MTI CSPI-CT Tool to predict and monitor fire-side ash deposition under a range of load conditions and fuel property variability in real time.

01 COAL, LIGNITE, AND PEAT↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Can a Nuclear-Assisted Biofuels System Enable Liquid Biofuels as the Economic Low-carbon Replacement for All Liquid Fossil Fuels and Hydrocarbon Feedstocks and Enable Negative Carbon Emissions?

This report integrates the results of a series of studies and workshops to address the question: Can a nuclear-assisted biofuels system enable liquid biofuels as the economic low-carbon replacement for all liquid fossil fuels and hydrocarbon feedstocks and simultaneously enable negative carbon emissions? “Economic” is defined as economically competitive relative to other low-carbon replacement options for crude oil. “All” refers to the capability to replace the 18 million barrels of oil per day used by the United States. “Nuclear-assisted” refers to the provision of massive quantities of low-carbon heat and hydrogen at the refinery to fully utilize the carbon content of the cellulosic biomass feedstocks for liquid hydrocarbon production. A system is proposed that decarbonizes about half of the U.S. economy while improving long-term soil productivity and sequestering carbon from the atmosphere. In the U.S. almost half the energy consumed by the final customer is in the form of liquid hydrocarbons produced from crude oil. Liquid hydrocarbons are used as (1) an energy source, (2) a method for daily-to-seasonal energy storage, (3) a chemical feedstock, (4) a chemical reducing agent, (5) a method to enhance high-temperature heat transfer in many furnaces and industrial processes and (6) other purposes. As a consequence, the U.S. consumes ~18 million barrels of crude oil per day to produce liquid hydrocarbons. While there are substitutes for liquid hydrocarbons for some applications, our assessment is that the costs and difficulty will dramatically increase if liquid hydrocarbon use goes much below the equivalent of 10 million barrels per day of crude oil. New uses of liquid hydrocarbons to partly replace coal and natural gas could increase demand beyond the equivalent of 10 million barrels of oil per day. One can produce and burn liquid hydrocarbons from biomass without any net addition of carbon dioxide to the atmosphere. Plants grow by removing carbon dioxide from the atmosphere; thus, burning biomass does not result in any net addition of carbon dioxide to the atmosphere. Biomass is typically 40% oxygen. To remove this oxygen to create hydrocarbon liquids, there are two options. The first option is to use biomass as (1) a feedstock, (2) an energy source to operate the process and (3) a supply of carbon to remove the biomass oxygen as carbon dioxide. The second option is to use external heat and hydrogen to remove the oxygen as water and produce liquid hydrocarbons. The use of massive quantities of external heat and hydrogen for hydrocarbon liquid fuels production reduces the biomass feedstock per unit of liquid hydrocarbon product by more than a factor of two reducing land use by more than a factor of two. Many cellulosic feedstocks unsuitable for liquid hydrocarbon production are viable feedstocks with external heat and hydrogen inputs. As a result, there is sufficient cellulosic feedstocks to meet U.S. and global liquid fuels hydrocarbon demand without significant impacts on food and fiber prices. The heat and hydrogen (heat plus electricity) are produced using base-load nuclear power plants—the most economic form of nuclear energy. If low-price natural gas, there is also the option of producing hydrogen from natural gas with sequestration of the carbon dioxide. The biomass is locally processed in depots to produce commodity feedstocks that can be shipped long distances to large biorefineries (250,000 barrels per day, oil equivalent) similar to existing refineries except modifications of front-end processes. The depot system enables local recycle of nutrients back to the soil. The biorefinery can produce variable quantities of liquid hydrocarbon fuels and carbon dioxide for sequestration enabling removal of carbon dioxide from the atmosphere. Preliminary estimates are that the liquid hydrocarbon costs are equivalent to crude oil at between $60 and $70 per barrel. The largest cost is for hydrogen with biomass feedstocks and refinery costs a smaller fraction of the total cost.

09 BIOMASS FUELS↗

Saving Energy, Saving Money [Slides]

Make sure you have CO detectors installed; Test batteries regularly; Have your furnace serviced annually; Don’t use grills or generators indoors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review of Mercury Sequestration in Cementitious Waste Forms

Decontaminated salt solution from Tank 50 at the Savannah River Site (SRS) is known to contain dissolved mercury species which are present as hydroxides and oxides. These species are reported in analytical measurements as the organic cation [CH 3 Hg] + and the inorganic cation Hg 2+ . The salt solution is mixed with cementitious reagents, blast-furnace slag (BFS) and thermally beneficiated Class F fly ash in the Saltstone Processing Facility and pumped into engineered Saltstone Disposal Units, (SDUs), to produce a solidified waste form. The solidified waste form, saltstone, encapsulates and chemically stabilizes the mercury and other contaminants, sequestering them from release into the environment. With the discovery of methylmercury in the salt solution, testing was performed to determine the extent to which saltstone prepared with methylmercury (MeHg) retains mercury in the Toxicity Characteristic Leaching Procedure (TCLP). Results from this testing indicated that the amount of mercury extracted remained below the regulatory limit, and that the saltstone formulation with a greater proportion of BFS performed slightly better at retaining Hg in the solid.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CEM MARS 6 Microwave Incident

A fire occurred in a CEM MARS 6 analytical microwave during microwave-assisted, acid digestion of a soil sample in a Research and Development (R&D) laboratory. The soil sample had been pretreated at 550°C for approximately 4 hours in a furnace prior to digesting in the microwave. Less than 1-gram aliquots of the pretreated soil sample were placed into separate microwave reaction vessels along with an acid mixture used for digestion. The microwave was used to facilitate digestion of the samples. Microwave reaction vessels were loaded with acid and soil samples, sealed in cassettes, and the cassettes placed onto a microwave carousel. A temperature probe that senses the reaction temperature during the run was inserted into the Reference Cell thermowell. The contents of the Reference Cell were identical to the contents of the other reaction cells. The researcher initiated the run and then left the laboratory to perform other work. Upon returning to check the digestion run, flames and smoke were observed originating from the microwave. The researcher exited the lab, immediate emergency actions were taken, and the local fire department responded and extinguished the fire. No personnel were injured, and no facility structural damage occurred. The affected microwave is a total loss. The fire investigation revealed the most credible cause of the fire is an incompatible temperature probe that did not accurately measure temperature of the liquid phase of the Reference sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing Uranium Crystallization from Melt: Experiment-Informed Phase Field Modeling and Machine Learning

The focus of this project was to observe and simulate the solidification of uranium metal at the crystallographic level from its molten state. Melting experiments were conducted at two different scales to observe microstructural evolution using either a laboratory-scale induction furnace (hundreds of grams of metal) or a microscope heating stage (hundreds of milligrams of metal), respectively. Experimental parameters and characterization data were then used to inform a phase field model of gamma-U crystal growth as dendrites with or without secondary phase impurities in the form of uranium carbide particles. Finally, training datasets were generated by the phase field model as inputs to a neural network, developed with the aim of providing a faster, cheaper surrogate model for microstructural simulations within a given parameter space. Progress is reported herein for each of these task areas. Ultimately, 1) an optical microscope heating stage capability has been stood-up for uranium metal solidification studies, 2) a phase field model was advanced to simulate multiple uranium grains growing in the presence of carbide impurity particles and 3) a neural network was constructed and optimized to predict the microstructure features of individually growing uranium crystals.

36 MATERIALS SCIENCE↗

Mark-18A Loading Capacity and Dilute Acid Rinse of DGA Resin

Savannah River National Laboratory is developing a separations flowsheet for the recovery of valuable elements from irradiated 242 Pu targets. The primary impetus for this effort is to recover the rich amount of 244 Pu contained in the targets, however, the targets also contain other valuable isotopes such as heavy Cm and 241,243 Am. DGA Resin, developed by Eichrom Technologies Inc., was selected to recover these materials from the 7 – 9 M HNO 3 matrix raffinate of the anion exchange process used to separate Pu. The resin has a high affinity for trivalent actinides and rare earth elements (REEs) in moderate to strong nitric acid. After loading the resin, the extracted materials (including Cm and Am) are to be recovered as oxides in a two-step process by thermally drying and reducing the mass and volume of the resin in the process column followed by calcination of the resultant residue. It is desirable to reduce the amount of residual HNO 3 in the resin bed prior to these furnace operations, but the reduced acid concentration is known to lower the distribution coefficients of the components of interest to the extractant. The purpose of this study was to validate the loading capacity of the resin and determine losses to be expected from rinsing the loaded resin with dilute HNO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗