Sequential probabilities and the performance of serial tasks.
Sequential probabilities and performance of serial tasks in step function pursuit tracking tests
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Sequential probabilities and performance of serial tasks in step function pursuit tracking tests
Test failures of heat pipes occur when the functional performance is unable to match the expected design limits or when the power applied to the heat pipe (in the form of heat) is distributed unevenly through the system, yielding a large thermal gradient. When a thermal gradient larger than expected is measured, it normally occurs in the evaporator or condenser sections of the pipe. Common causes include evaporator overheating, condenser dropout, noncondensable gas formation, surge and partial recovery of evaporator temperatures, masking of thermal profiles, and simple malfunctions due to leaks and mechanical failures or flaws. Examples of each of these phenomena are described along with corresponding failure analyses and corrective measures.
The establishment of the Shuttle Avionica Integration Laboratory (SAIL) for performing avionics system integrated testing is discussed. The specific functions of the SAIL are described, and the organization and management methods are detailed.
Flight tests have been performed with a variable pitch-rate-command/attitude-hold flight control system in a Beechoraft Queen air-80 aircraft. Some results of in-flight measured runs for two pilots controlling typical easy and difficult dynamics are presented together with the initial results of the same tracking experiment performed on a ground-based flight simulator. Results are compared with results of other investigators using fixed-base flight simulators.
A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.
A method of analysis was developed for predicting permanent cyclic creep deflections in stiffened panel structures. This method uses creep equations based on cyclic tensile creep tests and a computer program to predict panel deflections as a function of mission cycle. Four materials were investigated - a titanium alloy (Ti-6Al-4V), a cobalt alloy (L605), and two nickel alloys (Rene'41 and TDNiCr). Steady-state and cyclic creep response data were obtained by testing tensile specimens fabricated from thin gage sheet (0.025 and 0.63 cm nominal). Steady-state and cyclic creep equations were developed which describe creep as a function of time, temperature and load. Tests were also performed on subsize (6.35 x 30.5 cm) rib and corrugation stiffened panels. These tests were used to correlate creep responses between elemental specimens and panels. The panel response was analyzed by use of a specially written computer program.
The classification/pixel-count method for estimating the proportion of wheat in each segment is theoretically biased even if all distributional assumptions are met. Alternative ways to estimate crop proportions are examined and their performance testing is considered. Topics covered include general linear functional estimates, the method of moments, and maximum likelihood estimators.
Ophthalmic instrument tests and helps develop focusing ability. Movable stage on a fixed base permits adjustment of effective target position as perceived by subject. Various apertures used to perform tests and training procedures. Ophthalmic instrument provides four functions: it measures visual near and far points; provides focus stimulus in vision research; measures visual-accommodation resting position; can be used to train for volitional control of person's focus response.
An integrated thermal energy storage (TES) system, developed as a part of an organic Rankine cycle solar dynamic power system is described, and the results of the performance verification tests of this TES system are presented. The integrated system consists of potassium heat-pipe elements that incorporate TES canisters within the vapor space, along with an organic fluid heater tube used as the condenser region of the heat pipe. The heat pipe assembly was operated through the range of design conditions from the nominal design input of 4.8 kW to a maximum of 5.7 kW. The performance verification tests show that the system meets the functional requirements of absorbing the solar energy reflected by the concentrator, transporting the energy to the organic Rankine heater, providing thermal storage for the eclipse phase, and allowing uniform discharge from the thermal storage to the heater.
The SCR, a rapid prototyping system for the development, testing, and implementation of speech commands in a flight simulator or test aircraft, is described. A single unit performs all functions needed during these three phases of system development, while the use of common software and speech command data structure files greatly reduces the preparation time for successive development phases. As a smart peripheral to a simulation or flight host computer, the SCR interprets the pilot's spoken input and passes command codes to the simulation or flight computer.
BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.
The Functional Task Tests (FTT) is an interdisciplinary study designed to correlate the changes in functional tasks (such as emergency egress, ladder climbing, and hatch opening) with changes in neuromuscular, cardiovascular, and sensorimotor function. One aspect of the FTT, the neuromuscular function test, is used to investigate the neuromuscular component underlying changes in the ability of astronauts to perform functional tasks (representative of critical mission tasks) safely and quickly after flight. PURPOSE: To describe neuromuscular function after short- and long-duration space flight. METHODS: To date, 5 crewmembers on short-duration (10- to 15-day) missions and 3 on long-duration missions have participated. Crewmembers were assessed 30 days before flight, on landing day (short-duration subjects only) and 1, 6, and 30 days after landing. The interpolated twitch technique, which utilizes a combination of maximal voluntary contractions and electrically evoked contractions, was used to assess the maximal voluntary isometric force (MIF) and central activation capacity of the knee extensors. Leg-press and bench-press devices were used to assess MIF and maximal dynamic power of the lower and upper body respectively. Specifically, power was measured during concentric-only ballistic throws of the leg-press sled and bench-press bar loaded to 40% and 30% of MIF respectively. RESULTS: Data are currently being collected from both Shuttle and ISS crewmembers. Emerging data indicate that measures of knee extensor muscle function are decreased with long-duration flight. DISCUSSION: The relationships between flight duration, neural drive, and muscle performance are of particular interest. Ongoing research will add to the current sample size and will focus on defining changes in muscle performance measures after long-duration space flight.
More than a metric ton of water is transported to the International Space Station (ISS) each year to provide breathing oxygen for the astronauts. Water is a safe and compact form of stored oxygen. The water is electrolyzed on ISS and ambient pressure oxygen is delivered to the cabin. A much smaller amount of oxygen is used each year in spacesuits to conduct Extra Vehicular Activities (EVAs). Space suits need high pressure (>1000 psia) high purity oxygen (must meet Aviator Breathing Oxygen "ABO" specifications, >99.5% O2). The water / water electrolysis system cannot directly provide high pressure, high purity oxygen, so oxygen for EVAs is transported to ISS in high pressure gas tanks. The tanks are relatively large and heavy, and the majority of the system launch weight is for the tanks and not the oxygen. Extracting high purity oxygen from cabin air and mechanically compressing the oxygen might enable on-board production of EVA grade oxygen using the existing water / water electrolysis system. This capability might also benefit human spaceflight missions, where oxygen for EVAs could be stored in the form of water, and converted into high pressure oxygen on-demand. Cerium oxide solid electrolyte-based ion transport membranes have been shown to separate oxygen from air, and a supported monolithic wafer form of the CeO2 electrolyte membrane has been shown to deliver oxygen at pressures greater than 300 psia. These supported monolithic wafers can withstand high pressure differentials even though the membrane is very thin, because the ion transport membrane is supported on both sides (Fig 1). The monolithic supported wafers have six distinct layers, each with matched coefficients of thermal expansion. The wafers are assembled into a cell stack which allows easy air flow across the wafers, uniform current distribution, and uniform current density (Fig 2). The oxygen separation is reported to be "infinitely selective" to oxygen [1] with reported purity of 99.99% [2]. Combined with a mechanical compressor, a Solid Electrolyte Oxygen Separator (SEOS) should be capable of producing ABO grade oxygen at pressures >2400 psia, on the space station. Feasibility tests using a SEOS integrated with a mechanical compressor identified an unexpected contaminant in the oxygen: water vapour was found in the oxygen product, sometimes at concentrations higher than 40 ppm (the ABO limit for water vapour is 7 ppm). If solid electrolyte membranes are really "infinitely selective" to oxygen as they are reported to be, where did the water come from? If water is getting into the oxygen, what other contaminants might get into the oxygen? Microscopic analyses of wafers, welds, and oxygen delivery tubes were performed in an attempt to find the source of the water vapour contamination. Hot and cold pressure decay tests were performed. Measurements of water vapour as a function of O2 delivery rate, O2 delivery pressure, and process air humidity levels were the most instructive in finding the source of water contamination (Fig 3). Water contamination was directly affected by oxygen delivery rate (doubling the oxygen production rate cut the water level in half). Water was affected by process air humidity levels and delivery pressure in a way that indicates the water was diffusing into the oxygen delivery system.
A set of small and lightweight laser retro-reflector arrays (LRAs) was fabricated and tested for use on lunar landersunder NASA's Commercial Lunar Payload Service program. Each array contains eight 1.27-cm-diameter cornercube retro-reflectors mounted on a dome-shaped aluminum structure. The arrays are 5.0cmin diameter at the base,1.6 cm in height, and 20 g in mass. They can be tracked by an orbiting laser altimeter, such as the Lunar OrbiterLaser Altimeter, froma distance of a few hundred kilometers or by a landing lidar on future lunar landers. TheLRAsdemonstrated a diffraction-limited optical performance. They were designed and tested to survive and function ontheMoon for decades,well after the lander missions are completed.
The MSFC System Integration Lab (SIL) supports avionics development of NASA’s Space Launch System—a new U.S. heavy-lift launch vehicle for NASA’s next generation of human space exploration beyond low-Earth orbit. The SIL facility allows for the incremental development of system components by either hosting real hardware in the loop and/or software models of those components. Through this functionality test teams are able to evaluate overall system performance as components are designed, built and modified. Early hardware/software integration and testing reduces risks and saves overall cost and schedule throughout a program/project life cycle. By performing early hardware/software integration, potential architecture and interface-related problems can be identified, and thus reduce associated risk as early in the design cycle as possible when problems are the least expensive to resolve while also improving the design and requirements. This presentation will illustrate the power of employing a hardware in the loop simulation system for the development of novel spacecraft avionics.
Nuclear thermal propulsion (NTP) is an in-space propulsion technology that uses a nuclear reactor to directly heat a propellant to provide high thrust, at higher efficiencies than achievable with conventional chemical propulsion systems. Due to the ability of NTP rockets to efficiently provide high thrust, this technology has been proposed for long duration space missions such as crewed missions to Mars and beyond. A primary hurdle for NTP technology development is the demonstration of an integrated reactor engine system to verify its functionality and performance. This primarily requires the manufacture and testing of candidate reactor and engine technologies to demonstrate the proposed design enables desired performance and exhibits acceptable response under all known operation modes. A major component in this testing is fission product accumulation, since after operation radioactive isotopes can be produced and pose radiological dose concerns. This paper explains the background behind fission product analysis and the methodology used to evaluate current reactor designs and identify the amount of fission products present and their radiological impact. Results of multiple thrust level engines at different time periods are discussed and highlight the need for additional experimental testing to confirm fractional release levels of fission products out of the system. Benchmarking of models and future paths of analysis are also discussed.
Nuclear thermal propulsion (NTP) is an in-space propulsion technology that uses a nuclear reactor to directly heat a propellant to provide high thrust, at higher efficiencies than achievable with conventional chemical propulsion systems. Due to the ability of NTP rockets to efficiently provide high thrust, this technology has been proposed for long duration space missions such as crewed missions to Mars and beyond. A primary hurdle for NTP technology development is the demonstration of an integrated reactor engine system to verify its functionality and performance. This primarily requires the manufacture and testing of candidate reactor and engine technologies to demonstrate the proposed design enables desired performance and exhibits acceptable response under all known operation modes. A major component in this testing is fission product accumulation, since after operation radioactive isotopes can be produced and pose radiological dose concerns. This paper explains the background behind fission product analysis and the methodology used to evaluate current reactor designs and identify the amount of fission products present and their radiological impact. Results of multiple thrust level engines at different time periods are discussed and highlight the need for additional experimental testing to confirm fractional release levels of fission products out of the system. Benchmarking of models and future paths of analysis are also discussed.
This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.