Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Photonic crystal ring resonator based optical filters for photonic integrated circuits

In this paper, a two Dimensional (2D) Photonic Crystal Ring Resonator (PCRR) based optical Filters namely Add Drop Filter, Bandpass Filter, and Bandstop Filter are designed for Photonic Integrated Circuits (PICs). The normalized output response of the filters is obtained using 2D Finite Difference Time Domain (FDTD) method and the band diagram of periodic and non-periodic structure is attained by Plane Wave Expansion (PWE) method. The size of the device is minimized from a scale of few tens of millimeters to the order of micrometers. The overall size of the filters is around 11.4 μm × 11.4 μm which is highly suitable of photonic integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU

Purpose: Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in the prostate and to monitor for potential damage to surrounding tissues. This requires that the MR thermometry measurements are an accurate representation of the true tissue temperature. The proton resonance frequency shift thermometry method used is sensitive to tissue motion and changes in the local magnetic susceptibility that can be caused by the motion of air bubbles in the rectum, which can impact the performance of transurethral MR-HIFU in these regions of the gland. Methods: A method is proposed for filtering of temperature artifacts based on the temporal variance of the temperature, using empirical and dynamic positional knowledge of the ultrasonic heating beam, and an estimation of the measurement noise. A two-step correction strategy is introduced which eliminates artifact-detected temperature variations while keeping the noise level low through spatial averaging. Results: The filter has been evaluated by postprocessing data from five human transurethral ultrasound treatments. The two-step correction process led to reduced final temperature standard deviation in the prostate and rectum areas where the artifact was located, without negatively affecting areas distal to the artifact. The performance of the filter was also found to be consistent across all six of the data sets evaluated. The evaluation of the detection criterion parameter M determined that a value of M = 3 achieves a conservative filter with minimal loss of spatial resolution during the process. Conclusions: The filter was able to remove most artifacts due to the presence of moving air bubbles in the rectum during transurethral MR-HIFU. A quantitative estimation of the filter capabilities shows a systematic improvement in the standard deviation of the corrected temperature maps in the rectum zone as well as in the entire acquired slice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-10: Effect of CT Reconstruction Filter On Measured Hounsfield Values in Lung Nodules

Purpose: Measured Hounsfield numbers in CT are used by radiologists to determine the presence of calcium or fat in lung nodules, either of which suggests a benign diagnosis. However, substantial variations in Hounsfield number may arise due to the use of different reconstruction parameters such as the filter/kernel, leading to measurement inaccuracies. This quality improvement project was developed to demonstrate measurement pitfalls and to identify acceptable conditions for incorporating Hounsfield values as a factor in lung nodule diagnosis. Methods: 12 mm-diameter spheres of polyurethane and urethane foam were placed into an anthropomorphic chest phantom, and 10 mm-diameter tubes with varying iodine concentrations were placed into a 16 cm PMMA cylindrical phantom. Additionally, 11 mm-diameter PMMA and HDPE spheres were placed in a 10 cm PMMA cylindrical phantom. Phantoms were scanned at 120 kVp using a Siemens Biograph mCT and on a Philips iCT and reconstructed using various reconstruction filters. Results: For the Siemens system, both sharp kernels and smooth kernels altered the Hounsfield numbers. Hounsfield numbers varied within a range of 8.9 HU for urethane foam and varied within 58.7 HU for polyurethane. The iodine measurements varied up to 37.9 HU for the lowest concentration. For the Philips system, Hounsfield numbers were relatively consistent but were higher for the “Detail” and “Lung Enhanced” filters, varying by 36.9 HU for PMMA and 15.9 HU for HDPE. Conclusion: Reconstruction filters can change the measured Hounsfield numbers of nodular objects, especially with detail-enhancing (sharpening) filters commonly used in lung imaging. Measured values should only be used for diagnostic decision support with filters that have demonstrated accuracy and consistency. While filter accuracy statements are available from manufacturers, radiologists are likely not aware of the extent of potential variations that can occur in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Evaluating the use of PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of nuclear canister filters

This document details the distinction between using PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of filters. This document is developed to justify the use of PAO rather than DOP for evaluating the performance of filters in the SAVY 4000 and Hagan containers. The design criteria (Anderson et al, 2012) for purchasing SAVY 4000 containers and the Safety Analysis Report for the SAVY 4000 Container Series specified that the filter must “capture greater than 99.97% of 0.45 μm mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter.”This corresponds to a leakage percent of 0.03% (3.0x10 -2 ). The density of DOP oil is 985 kg/m 3 and the density of PAO oil is 819 kg/m 3 . ATI Test Inc measured the mass mean diameter of aerosol distributions produced by a single Laskin type III-A nozzle operating at a 20 psig air pressure as 0.563 μm for DOP oil and 0.549 μm for PAO oil. (See Appendix A.) For both types of oil in this document, the single fiber method calculated the leakage percent to be 4.4x10 -5 for DOP oil and 4.7x10 -5 for PAO oil. Although the percent error between these two quantities is 7.7%, these calculated leakage percent values are more than two orders of magnitude less than the criterion specified in the SAVY canister SAR. As a point of reference, the photometer used to measure the SAVY canister filter performance cannot resolve values for the leakage percent below 1.0x10 -5 . Additionally, over a range of particle sizes from 0.01 μm to 3.0 μm, there was less than 4.0x10 -5 error between the calculated filter efficiency for the two types of oil at any particular particle size diameter. In conclusion, the difference between using DOP and PAO for testing SAVY canister filters is of inconsequential concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of an MCU HEPA filter

A series of direct analyses on three portions (inlet, center, and outlet) of the High Efficiency Particulate Air (HEPA) filter material from the Modular Caustic-Side Solvent Extraction Unit (MCU) have been performed; this includes x-ray methods such as X-Ray Diffraction (XRD), Contained Scanning Electron Microscopy (CSEM) and X-Ray Fluorescence (XRF), as well as Fourier Transform InfraRed spectroscopy (FTIR). Additionally, two leaching studies (one with water, one with dichloromethane) have been performed on three portions (inlet, center, and outlet) of the HEPA filter material, with the leachates being analyzed by Inductively-coupled plasma emission spectroscopy (ICPES), Semi-Volatile Organic Analysis (SVOA) and gammascan. From the results of the analyses, SRNL feels that cesium-depleted solvent is being introduced into the HEPA filter. The most likely avenue for this is mechanical aerosolization of solvent, where the aerosol is then carried along an airstream into the HEPA filter. Once introduced into the HEPA filter media, the solvent wicks throughout the material, and migrates towards the outlet end. Once on the outlet end, continual drying could cause particulate flakes to exit the filter and travel farther down the airstream path.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photometric Redshifts of Emission-line Galaxies Using Ramp Filters

Broadband photometric redshifts are routinely obtained for galaxies to estimate their distances. While effective for many uses, the common resolution in z of 0.01–0.02 is too coarse for detailed large-scale structure mapping, particularly in low-density volumes where the galaxy distribution is least understood. To map galaxies in these low-density volumes, and noting that the percentage of galaxies having emission tends to rise as number density decreases, we have designed a filter system to photometrically measure the redshifts of galaxies with emission. The system consists of two “ramp” filters that cover a common wavelength range with transmission curves sloping from blue to red and from red to blue respectively. This causes the intensity of the image through either filter to be a function of the wavelength of the emission line. A third filter with a bandpass to the side is used to measure and remove the continuum. We have obtained a set of such filters that are tuned for isolating Hα in the redshift range of 3,000–9,000 km s{sup −1}. Simulated photometry, applied to spectra of 197 emission-line galaxies from the SDSS, shows the accuracy of the method to be between 250 and 620 km s{sup −1}, depending on line strength. Actual photometry of a sample of 16 active galaxies measured their redshifts with an accuracy of 573 km s{sup −1}. This is approximately an order of magnitude more accurate than broadband photometric redshifts. We discuss the errors inherent in this method and present ways to modify the filter set to further improve accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

Filter Tuning Using the Chi-Squared Statistic

The Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF) performs orbit determination (OD) for the Aqua and Aura satellites. Both satellites are located in low Earth orbit (LEO), and are part of what is considered the A-Train satellite constellation. Both spacecraft are currently in the science phase of their respective missions. The FDF has recently been tasked with delivering definitive covariance for each satellite.The main source of orbit determination used for these missions is the Orbit Determination Toolkit developed by Analytical Graphics Inc. (AGI). This software uses an Extended Kalman Filter (EKF) to estimate the states of both spacecraft. The filter incorporates force modelling, ground station and space network measurements to determine spacecraft states. It also generates a covariance at each measurement. This covariance can be useful for evaluating the overall performance of the tracking data measurements and the filter itself. An accurate covariance is also useful for covariance propagation which is utilized in collision avoidance operations. It is also valuable when attempting to determine if the current orbital solution will meet mission requirements in the future.This paper examines the use of the Chi-square statistic as a means of evaluating filter performance. The Chi-square statistic is calculated to determine the realism of a covariance based on the prediction accuracy and the covariance values at a given point in time. Once calculated, it is the distribution of this statistic that provides insight on the accuracy of the covariance.For the EKF to correctly calculate the covariance, error models associated with tracking data measurements must be accurately tuned. Over estimating or under estimating these error values can have detrimental effects on the overall filter performance. The filter incorporates ground station measurements, which can be tuned based on the accuracy of the individual ground stations. It also includes measurements from the NASA space network (SN), which can be affected by the assumed accuracy of the TDRS satellite state at the time of the measurement.The force modelling in the EKF is also an important factor that affects the propagation accuracy and covariance sizing. The dominant force in the LEO orbit regime is the drag force caused by atmospheric drag. Accurate accounting of the drag force is especially important for the accuracy of the propagated state. The implementation of a box and wing model to improve drag estimation accuracy, and its overall effect on the covariance state is explored.The process of tuning the EKF for Aqua and Aura support is described, including examination of the measurement errors of available observation types (Doppler and range), and methods of dealing with potentially volatile atmospheric drag modeling. Predictive accuracy and the distribution of the Chi-square statistic, calculated based of the ODTK EKF solutions, are assessed versus accepted norms for the orbit regime.

Covariance Analysis↗

Between-Simulator Comparison of Motion Filter Order and Break Frequency Interaction Effects on Pilot Control Behavior

This paper investigates the interaction effects of motion filter order and break frequency on pilots' manual control behavior and control performance using two simulators. Eighteen pilots performed the experiment in the Vertical Motion Simulator (VMS) at NASA Ames Research Center and twenty pilots in the SIMONA Research Simulator at Delft University of Technology. The experiment used a full-factorial design with three motion filter orders (first-, second-, and third-order) and two filter break frequencies (0.5 and 2.0 rad/s), in addition to reference no-motion and full-motion conditions. Key task variables, such as the quality of the motion and visual cues and the characteristics of the sidestick, were matched across both simulators. Overall, the expected effects of filter order and break frequency variations were found, with both increasing order and increasing break frequency causing pilots to use less motion feedback in their control strategy, resulting in lower tracking performance. Furthermore, across the wide range of filter orders tested in the experiment, the existing Sinacori-Schroeder motion fidelity criterion was found to be a good predictor of the interaction effects of both filter settings on pilot control behavior. For the same motion condition, there was a consistent offset in the results between simulators, due to the more high-gain control strategy adopted by a number of the VMS pilots. Still, the observed relative trends in pilot control behavior and performance between motion conditions were equivalent in both simulators and thus accurately replicated.

manual control↗

Proposed Protocols for Defining Requirements and Sizing of Media-Based Filters for Spacecraft and Planetary Lander Applications

The air quality control equipment aboard future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation in low gravity, and can experience short duration peak loading of dust from planetary surfaces for Lunar or Mars landers. The filter industry has established methods to properly size filters for a given particulate load, but requirements for the space or planetary application introduce additional consideration. In this work, a methodology for properly evaluating and sizing particulate filters for a Lunar surface pressurized environment will be presented, including estimating the loading and particle size distributions of the loading based on mission requirements. In addition, a scaling analysis from single filter media sheet to full-scale filters for this application, based on recent testing, will also be presented. These results of this study may provide meaningful guidance for properly designing media-based particulate filters for the air revitalization challenges in future deep space exploration missions.

media-based filters↗

Turbulence Effects on Shaped Booms: Finite Impulse Response Filter Development

Numerical simulations of propagation through turbulent atmospheres can quantify effects on ground waveforms, but such simulations are computationally expensive. To enable quick turnaround analyses as required by NASA’s Quesst Mission, updating the N-wave filtering approach developed by researchers at The Pennsylvania State University to include shaped booms is proposed as an alternative method for estimating turbulence effects on acoustic metrics more quickly. Beginning with a nearfield pressure cylinder modeled after the on-design X-59 configuration, a database of propagation results at 45 turbulence conditions was compiled using nonlinear turbulence propagation modeling code (KZKFourier) and used as input to a process for generating finite impulse response (FIR) filters. Ground waveforms distorted by turbulence were selected to represent mean and mean±standard deviation levels for six metrics, and corresponding FIR filters were generated through a matrix deconvolution process. In order to evaluate how well the FIR filters perform, additional KZKFourier verification cases were devised with different input conditions, and results used as a benchmark. Convolution of shaped boom waveforms modeled using nonturbulent propagation simulations with the new FIR filters showed better agreement on average with KZKFourier statistical results than the N-wave-based FIR filters.

turbulence↗

Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institute (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: {sup 108m}Ag, {sup 110m}Ag, {sup 60}Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiochemical Method for Characterization of the Filter Cartridges from the IEA-R1 Reactor - 16324

The filter cartridges used in water purification system of the IEA-R1 research reactor become radioactive waste after the end of their useful life. The characterization of this waste is one step in their management, which aims at identifying and quantifying the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Wastes from nuclear reactors contain fission and activation products and transuranic elements, only few of them emitting gamma radiation measurable by simple gamma spectrometry methods. In routine waste management activities, the concentrations of the DTM can only be estimated by indirect methods such as scaling factors. The method of the scaling factors uses empirically determined proportions between the concentrations of DTM radionuclides and that of easily measurable gamma emitters called key nuclides (KN), to calculate DTM concentrations. Determining the scaling factors for the filter cartridges is a hard task when the number of samples is large, not only because the preparation of samples is difficult but also because the number of radionuclides to analyze is large. If it can be demonstrated that DTM and KN are both distributed evenly in the filters, less samples from each filter are necessary, reducing lab work. The aim of this paper is to present the results of the assessment of homogeneity along the filter cartridges by gamma spectrometry of chemically reduced samples. Five thin slices of five filters were burnt and the ashes quantitatively dissolved and the activity concentration of the solutions determined by gamma spectrometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance and Implementation of Hydrophobic Filter Material for Nuclear Material Transportation and Storage Containers - 18550

Los Alamos National Laboratory has developed a hydrophobic filter material that resists water ingress after exposure to radiation and/or elevated temperature. Facility and transportation accident scenarios often include fire, impact and subsequent water spray or flooding conditions. The hydrophobic filter material provides enhanced resistance to fire and radiation damage, and continues to minimize water ingress after such an accident. Test results indicate that the treated filters provide resistance to a water column pressure test and have filtration efficiencies and air flow pressure drops that meet the current performance criteria for the SAVY{sup TM}-4000. These filters could broaden the use of filtered containers in the transportation and storage of nuclear materials, and could have broader implications in other industrial applications. Implementation of the new hydrophobic filter material is planned for the SAVY{sup TM}-4000 nuclear storage container, which will lead the way for this robust material to be applied to other nuclear material transportation and storage containers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Miniature High Temperature Testing Unit for HEPA Filter Materials R and D

The objective of this research is to develop and deploy advances in High Efficiency Particulate Air (HEPA) filter technology to benefit nuclear facilities. There is a need for better HEPA filter materials, especially those able to withstand moisture and higher temperatures as experienced in fire conditions. In order to test these materials, student teams at California Polytechnic State University (Cal Poly) have developed tools with the sponsorship and direction of Lawrence Livermore National Laboratory (LLNL). The Miniature High Temperature Testing Unit (MiniHTTU) can rapidly, efficiently and inexpensively test a large number of new and innovative materials for HEPA filter components. MiniHTTU test results will be used to down select the most promising materials for HEPA filter components (e.g., media, sealants, gaskets) for full scale testing in the full size High Temperature Testing Unit (HTTU). Using both testing units, future teams will be able to develop advances in HEPA filter technology (e.g., related to ceramic HEPA filters), the deployment of which will benefit DOE nuclear facilities by providing lower life-cycle costs and reducing or eliminating certain safety basis costs associated with safety class and safety significant systems in nuclear facilities. (authors)

36 MATERIALS SCIENCE↗