Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Automatic Fault Characterization via Abnormality-Enhanced Classification

Enterprise and high-performance computing systems are growing extremely large and complex, employing hundreds to hundreds of thousands of processors and software/hardware stacks built by many people across many organizations. As the growing scale of these machines increases the frequency of faults, system complexity makes these faults difficult to detect and to diagnose. Current system management techniques, which focus primarily on efficient data access and query mechanisms, require system administrators to examine the behavior of various system services manually. Growing system complexity is making this manual process unmanageable: administrators require more effective management tools that can detect faults and help to identify their root causes. System administrators need timely notification when a fault is manifested that includes the type of fault, the time period in which it occurred and the processor on which it originated. Statistical modeling approaches can accurately characterize system behavior. However, the complex effects of system faults make these tools difficult to apply effectively. This paper investigates the application of classification and clustering algorithms to fault detection and characterization. We show experimentally that naively applying these methods achieves poor accuracy. Further, we design novel techniques that combine classification algorithms with information on the abnormality of application behavior to improve detection and characterization accuracy. Our experiments demonstrate that these techniques can detect and characterize faults with 65% accuracy, compared to just 5% accuracy for naive approaches.

97 MATHEMATICS AND COMPUTING↗

Automatic Detection Of Faults In Turbomachinery Bearings

System of analog and digital signal-processing equipment, computers, and programs detects faults in ball bearings in turbomachines. System operates in real time, extracting information from vibrations sensed by accelerometers, strain gauges, and/or acoustical sensors. Vibrations caused when pits in balls contact races, and pits in races contact balls.

Higbie, Nathan B.↗

Identifiability of Additive Actuator and Sensor Faults by State Augmentation

A class of fault detection and identification (FDI) methods for bias-type actuator and sensor faults is explored in detail from the point of view of fault identifiability. The methods use state augmentation along with banks of Kalman-Bucy filters for fault detection, fault pattern determination, and fault value estimation. A complete characterization of conditions for identifiability of bias-type actuator faults, sensor faults, and simultaneous actuator and sensor faults is presented. It is shown that FDI of simultaneous actuator and sensor faults is not possible using these methods when all sensors have unknown biases. The fault identifiability conditions are demonstrated via numerical examples. The analytical and numerical results indicate that caution must be exercised to ensure fault identifiability for different fault patterns when using such methods.

Joshi, Suresh↗

Automated Monitoring with a BCP Fault-Decision Test

The Bayesian conditional probability (BCP) technique is a statistical fault-decision technique that is suitable as the mathematical basis of the fault-manager module in the automated-monitoring system and method described in the immediately preceding article. Within the automated-monitoring system, the fault-manager module operates in conjunction with the fault-detector module, which can be based on any one of several fault-detection techniques; examples include a threshold-limit-comparison technique or the BSP or SPRT technique mentioned in the preceding article. The present BCP technique is used to evaluate a series of one or more fault-detection events for the purpose of filtering out occasional false alarms produced by many types of statistical fault-detection procedures. The BCP technique increases the probability that an automated monitoring system produces a correct decision regarding the presence or absence of a fault. Because occasional false alarms are an inevitable consequence of the SPRT, BSP, or any other statistically based fault-detection test, there is a need for a logical procedure to distinguish between true and false alarms. Heretofore, it has been common practice to make a fault decision on an ad hoc basis for example by following a multiple-observation voting strategy in which a signal is declared to be indicative of a fault if m of the last n observations produced a fault-detection alarm. The BCP technique was developed to obtain results more reliable than those afforded by a voting strategy. The BCP technique involves a test in which one applies Bayesian inference techniques to a series of one or more single-observation alarms produced by a fault-detection test. One considers the last n decisions generated by a fault-detection test in order to evaluate the conditional probability that a failure is indicated (see figure). Each new decision reached by a fault-detection test is treated as a new piece of evidence about the state of the monitored asset, and the conditional probability of failure for the system is updated on the basis of this new evidence. The conditional probability of failure is compared with a predefined limit. For a probability below the limit, the asset is declared to be healthy. For a probability above the limit, the asset is declared to be faulty.

Bickford, Randall L.↗

Methodological approach to the sensitivity analysis of failure effects in modern digital I and C systems - 136

Modern I and C systems of nuclear power plants increasingly use digital equipment, software-based applications for I and C functions and different types and topologies of communication networks as well. The structure, operation and communication of digital safety-related I and C systems are strongly influenced by the implemented automatic fault detection and fault treatment procedures as barriers against failure propagation. Thus, these I and C systems can change their operating states automatically during the operation time, e.g. due to the detection and correction of certain failure types. Reasonably because of these dynamic properties of digital I and C systems the use of classical fault tree and event tree methods solely for the reliability analysis of modern I and C systems is less suitable. These methods basically apply static models and do not consider the temporal changes of the operating state of the I and C system or equipment appropriately. In this paper, a recently developed approach for the sensitivity analysis of digital I and C systems will be introduced that allows to investigate the dynamic behavior of such systems in cases of internal faults and to quantify the effects on the system reliability. The development and testing of the analysis methodology is carried out using models of generic I and C systems with different typical architectures of stepwise increased complexity. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analytical Redundancy Using Kalman Filters for Rocket Engine Sensor Validation

The use of sensor redundancy is crucial in aerospace systems to maintain safe, reliable operation. While hardware redundancy is more common in application, analytical redundancy can provide a viable alternative in systems where the installation of multiple redundant sensors is not viable. To this end, the use of Kalman filters to analytically validate sensor measurements within rocket engines was explored. First, a dynamic model of the RS 25 engine, a derivative of the Space Shuttle Main Engine (SSME), was reduced to a subset of relations, focused around the main combustion chamber pressure. These relations were used within the Kalman filter algorithm to generate an estimate of sensor measurements to be compared with true measurements for data validation purposes. By using a bank of Kalman filters, the residuals between the estimated and true measurements were used to detect and isolate sensor faults. Through fault simulations, the sensor validation performance of this Kalman filter bank design was compared to a hardware redundancy check. Sensor bias and drift faults of various magnitudes were injected into nominal RS 25 engine test data. Results for both approaches show comparable fault detection with most bias faults found nearly instantaneously by both algorithms. Drift fault detection results show certain cases where one algorithm is faster than the other. The key advantage of the Kalman filter algorithm is shown in fault isolation performance where it can isolate faults between two redundant sensors while the hardware redundancy comparisons cannot.

sensors↗

Integration of remote sensing and surface geophysics in the detection of faults

Remote sensing was included in a comprehensive investigation of the use of geophysical techniques to aid in underground mine placement. The primary objective was to detect faults and slumping, features which, due to structural weakness and excess water, cause construction difficulties and safety hazards in mine construction. Preliminary geologic reconnaissance was performed on a potential site for an underground oil shale mine in the Piceance Creek Basin of Colorado. LANDSAT data, black and white aerial photography and 3 cm radar imagery were obtained. LANDSAT data were primarily used in optical imagery and digital tape forms, both of which were analyzed and enhanced by computer techniques. The aerial photography and radar data offered supplemental information. Surface linears in the test area were located and mapped principally from LANDSAT data. A specific, relatively wide, linear pointed directly toward the test site, but did not extend into it. Density slicing, ratioing, and edge enhancement of the LANDSAT data all indicated the existence of this linear. Radar imagery marginally confirmed the linear, while aerial photography did not confirm it.

Jackson, P. L.↗

Process prediction and detection of faults using probabilistic bidirectional recurrent neural networks on real plant data

Attaining Industry 4.0 for manufacturing operations requires advanced monitoring systems and real-time data analytics of plant data, among other topics. We propose a Probabilistic Bidirectional Recurrent Network (PBRN) for industrial process monitoring for the early detection of faults. The model is based on a Gated Recurrent Unit (GRU) neural network that allows the model to retain long-term dependencies between sensor data along a time horizon, hence learning the dynamic behavior of the process. To reduce the false-positive detection rate of the model, we compel the model to learn from a highly noisy sensor reading while outputting noise-free sensor outputs. The performance of the proposed model is compared to other data-driven statistical process monitoring schemes using real plant data from an industrial Air Separations Unit (ASU) containing noisy sensor readings. We show that the model can learn from noisy data without reducing its performance. Using two different fault cases, we demonstrate the model’s ability to carry out early fault detection with average false-positive rates of 2.9% and 4.9% for both fault cases. The missed detection rates are 0.1% and 0.2%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Runtime Verification in Context : Can Optimizing Error Detection Improve Fault Diagnosis

Runtime verification has primarily been developed and evaluated as a means of enriching the software testing process. While many researchers have pointed to its potential applicability in online approaches to software fault tolerance, there has been a dearth of work exploring the details of how that might be accomplished. In this paper, we describe how a component-oriented approach to software health management exposes the connections between program execution, error detection, fault diagnosis, and recovery. We identify both research challenges and opportunities in exploiting those connections. Specifically, we describe how recent approaches to reducing the overhead of runtime monitoring aimed at error detection might be adapted to reduce the overhead and improve the effectiveness of fault diagnosis.

Dwyer, Matthew B.↗

Long-Term Statistical Process Monitoring of an Ultrafiltration Water Treatment Process

As water treatment technology has improved, the amount of available process data has substantially increased, making real-time, data-driven fault detection a reality. One shortcoming of the fault detection literature is that methods are usually evaluated by comparing their performance on hand-picked, short-term case studies, which yields no insight into long-term performance. In this work, we first evaluate multiple statistical and machine learning approaches for detrending process data. Then, we evaluate the performance of a PCA-based fault detection approach, applied to the detrended data, to monitor influent water quality, filtrate quality, and membrane fouling of an ultrafiltration membrane system for indirect potable reuse. Based on two short case studies, the adaptive lasso detrending method is selected, and the performance of the multivariate approach is evaluated over more than a year. The method is tested for different sets of three critical tuning parameters, and we find that for long-term, autonomous monitoring to be successful, these parameters should be carefully evaluated. However, in comparison with industry standards of simpler, univariate monitoring or daily pressure decay tests, multivariate monitoring produces substantial benefits in long-term testing.

ammonia↗

A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

Simon, Donald L.↗

Spatial-Temporal Recurrent Graph Neural Networks for Fault Diagnostics in Power Distribution Systems

Fault diagnostics are extremely important to decide proper actions toward fault isolation and system restoration. The growing integration of inverter-based distributed energy resources imposes strong influences on fault detection using traditional overcurrent relays. This paper utilizes emerging graph learning techniques to build new temporal recurrent graph neural network models for fault diagnostics. The temporal recurrent graph neural network structures can extract the spatial-temporal features from data of voltage measurement units installed at the critical buses. From these features, fault event detection, fault type/phase classification, and fault location are performed. Compared with previous works, the proposed temporal recurrent graph neural networks provide a better generalization for fault diagnostics. Moreover, the proposed scheme retrieves the voltage signals instead of current signals so that there is no need to install relays at all lines of the distribution system. Therefore, the proposed scheme is generalizable and not limited by the number of relays installed. The effectiveness of the proposed method is comprehensively evaluated on the Potsdam microgrid and IEEE 123-node system in comparison with other neural network structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-dimensional seismic characterization and imaging of the Soda Lake geothermal field

Accurate characterization of subsurface geophysical properties and detection of the fault system are essential for geothermal energy exploration and production. The Soda Lake geothermal field is in western Nevada with a complex fault system. Previous seismic characterization only produced a low-resolution, smooth velocity model along with a simple, conceptual fault model. Using optimized correlation-based full-waveform inversion, wavefield-separation-based reverse-time migration, and automatic fault detection techniques, we present 3D seismic characterization for the Soda Lake geothermal field using 3D surface seismic data acquired with Vibroseis sources. Here, we obtain 3D high-resolution velocity, density, and acoustic impedance models, 3D seismic images with different grid spacings, and a high-resolution fault system. Consistency check between the constructed faults and currently active injection and production geothermal wells verifies that our seismic inversion and imaging results and detected faults are reliable. These results can provide valuable information for optimizing well placement and geothermal energy production at the Soda Lake geothermal field.

15 GEOTHERMAL ENERGY↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine

03 NATURAL GAS↗

Multivariate Time Series Intermittent Fault Detectionin Controller Area Network CAN

Fault detection in Controller Area Network (CAN) systems is crucial for ensuring the reliability and safety of automotive and industrial applications. This study investigates and compares the effectiveness of time series classification models for supervised fault detection in CAN data. This repository contains the code and data for our benchmarking experiment aimed at detecting intermittent faults in automotive Controller Area Network (CAN) data. The goal of this project is to compare various machine learning (ML) and deep learning (DL) models using different Time Series Cross-Validation (TSCV) techniques to evaluate their effectiveness in a streaming environment for fault detection.

Hespeler, Steven [Oak Ridge National Laboratory (O↗

Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

Energy Management and Information Systems (EMIS) comprise a broad family of tools and services to manage commercial building energy use. These technologies offer a mix of capabilities to store, display, and analyze energy use and system data, and in some cases, provide control. EMIS technologies enable 10–20 percent site energy savings in best practice implementations. Energy Information System (EIS) and Fault Detection and Diagnosis (FDD) systems are two key technologies in the EMIS family. Energy Information Systems are broadly defined as the web-based software, data acquisition hardware, and communication systems used to analyze and display building energy performance. At a minimum, an EIS provides daily, hourly or sub-hourly interval meter data at the whole-building level, with graphical and analytical capability. Fault Detection and Diagnosis systems automatically identify heating, ventilation, and air-conditioning (HVAC) system or equipment-level performances issues, and in some cases are able to isolate the root causes of the problem. They use computer algorithms to continuously analyze system-level operational data to detect faults and diagnose their causes. Many FDD tools integrate the trend log data from a Building Automation System (BAS) but otherwise are stand-alone software packages; other types of FDD tools are implemented as “on-board” equipment-embedded diagnostics. (This document focuses on the former.) Analysis approaches adopted in FDD technologies span a variety of techniques from rule-based methods to process history-based approaches. FDD tools automate investigations that can be conducted via manual data inspection by someone with expert knowledge, thereby expanding accessibility and breath of analysis opportunity, and also reducing complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗