Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “export”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Optimal Sizing and Operation of a Hybrid Clean Energy Center

In this paper, we consider the deployment of battery energy storage systems (BESSs) paired with photovoltaics (PV) to form a hybrid clean energy center (HCEC), where the BESS is equipped for two main purposes: i) reducing the volatility of PV output and ii) shifting energy to meet an export limit. We develop a linear dynamical model to characterize the output of an HCEC and express the volatility and export power as functions of the battery's dispatch operations. We also propose an optimal sizing method via second-order cone programming (SOCP) to maximize the net benefits of the HCEC. Numerical studies are performed to illustrate and validate the proposed method.

Battery energy storage systems, photovoltaics, sec↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Optimal Storage Response to Utility Tariff Structures and Potential Use of Capacity Charges

Energy storage is increasingly being deployed in behind-the-meter use cases, partially in response to falling lithium-ion prices and new utility tariff structures. Utilities are grappling with new tariff design in the presence of distributed energy resources (DER), trying to motivate, fairly price the contribution of, and, in some cases, discourage, certain operation of DER. There are opportunities for energy storage under emerging tariff structures, but utility net load management objectives for storage remain unclear. Diverse tariff structures motivate the use of energy storage to provide one or a combination of: energy arbitrage, energy shifting, solar self-consumption, and import shaving. This paper formulates a linear optimization to demonstrate the optimal storage tariff response, examining customer net load metrics under diverse utility tariff structures, such as time-of-use, net metering, feed-in tariffs, zero export tariffs, and demand charges. A key contribution of this paper is the introduction and examination of a capacity charge as mechanism that can both motivate reductions in both peak import, and exports, along with greater load levelling.

behind-the-meter↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Same Data, Different Audiences: Using Personas to Scope a Supercomputing Job Queue Visualization

Domain-specific visualizations sometimes focus on narrow, albeit important, tasks for one group of users. This focus limits the utility of a visualization to other groups working with the same data. While tasks elicited from other groups can present a design pitfall if not disambiguated, they also present a design opportunity—namely, the development of visualizations that support multiple groups. This development choice presents a trade-off of broadening the scope but limiting support for the more narrow tasks of any one group, which in some cases can enhance the overall utility of the visualization. We investigate this scenario through a design study where we develop Guidepost, a notebook-embedded visualization of data that helps scientists assess compute wait times, machine learning researchers understand prediction accuracy, and system maintainers analyze usage trends. We adapt the use of personas for visualization design from existing literature in the HCI and design domains, applying them to categorize tasks based on their uniqueness across stakeholder personas. Under this model, tasks shared between all groups should be supported by interactive visualizations and tasks unique to each group can be deferred to scripting with notebook-embedded visualization design. We evaluate our visualization through real-world case studies and a task-focused evaluation with nine participants. We observe that together, Guidepost's visual encodings, interactions, and export capabilities support the tasks of our differing personas.

97 MATHEMATICS AND COMPUTING↗

Tigers at a crossroads: Shedding light on the role of Bangladesh in the illegal trade of this iconic big cat

Abstract Unsustainable wildlife trade is a major threat to many species, but quantifying trade remains challenging, as seizure data provides an incomplete understanding. For this reason, integrating multiple types of information, including interviews with actors involved in trade, is crucial if we are to understand the problem better. Hence, in this study, we digitized Bangladesh Forest Department tiger seizure records to identify trade routes and interviewed 163 individuals involved in trafficking tigers through Bangladesh's air, sea and land ports, including poachers, smugglers, and traders. We identified six ports used to import tigers, 14 ports used for tiger export and three ports showing bi‐directional trade. Elite Bangladeshis were the most important consumer group, and tigers were sourced from populations in NE India, Myanmar and Bangladesh Sundarbans to supply domestic demand. Tiger products were exported to 14 countries, including seven G20 nations, with Bangladeshi expatriates as the consumer group in three countries (United Kingdom, Germany and Qatar). Rising economic development in Bangladesh over the last decade, combined with deep‐rooted cultural ties to tiger consumption, has led to a rise in domestic demand. Additionally, rapid growth in international transport links has increased smuggling and connected local traders with global markets, increasing the complexity of global trade. These findings suggest Bangladesh is poised to play a pivotal role in tiger conservation over the next decade, requiring strong national strategies to reduce trade opportunities, disrupt networks and weaken demand.

Uddin, Nasir↗

Field‐scale analysis of miscanthus production indicates climate change may increase the opportunity for water quality improvement in a key Iowa watershed

Abstract The Raccoon River Basin is the primary source for drinking water in Iowa's largest city and plays a major role in the Mississippi River Basin's high nutrient exports. Future climate change may have major impacts on the biological, physiological, and agronomic processes imposing a threat to ecosystem services. Efforts to reduce nitrogen (N) loads within this basin have included local litigation and the implementation of the Iowa Nutrient Reduction Strategy, which suggest incorporating bioenergy crops (i.e., miscanthus) within the current corn–soybean landscape to reach a 41% reduction in nitrate loads. This study focuses on simulating N export for historical and future land use scenarios by using an agroecosystem model (Agro‐IBIS) and a hydrology model (THMB) at the 500‐m resolution, similar to the scale of agricultural fields. Model simulations are driven by CMIP5 climate data for historical, mid‐century, and late‐century under the RCP 4.5 and 8.5 warming projections. Using recent crop profit analyses for the state of Iowa, profitability maps were generated and nitrogen leaching thresholds were used to determine where miscanthus should replace corn–soybean area to maximize reductions in N pollution. Our results show that miscanthus inclusion on low profit and high N leaching areas can result in a 4% reduction of N loss under current climate conditions and may reduce N loss by 21%–26% under future climate conditions, implying that water quality has the potential continue to improve under future climate conditions when strategically implemented conservation practices are included in future farm management plans.

54 ENVIRONMENTAL SCIENCES↗

Contrasting anther glucose–6–phosphate dehydrogenase activities between two bean varieties suggest an important role in reproductive heat tolerance

Common beans (Phaseolus vulgaris) are highly sensitive to elevated temperatures, and rising global temperatures threaten bean production. Plants at the reproductive stage are especially susceptible to heat stress due to damage to male (anthers) and female (ovary) reproductive tissues, with anthers being more sensitive to heat. Heat damage promotes early tapetal cell degradation, and in beans this was shown to cause male infertility. In this study, we focus on understanding how changes in leaf carbon export in response to elevated temperature stress contribute to heat-induced infertility. We hypothesize that anther glucose-6-phosphate dehydrogenase (G6PDH) activity plays an important role at elevated temperature and promotes thermotolerance. To test this hypothesis, we compared heat-tolerant and susceptible common bean genotypes using a combination of phenotypic, biochemical, and physiological approaches. Our results identified changes in leaf sucrose export, anther sugar accumulation and G6PDH activity and anther H 2 O 2 levels and antioxidant-related enzymes between genotypes at elevated temperature. Further, anther respiration rate was found to be lower at high temperature in both bean varieties. Overall, our results support the hypothesis that enhanced male reproductive heat tolerance involves changes in the anther oxidative pentose phosphate pathway, which supplies reductants to critical H 2 O 2 scavenging enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-12: A Feasibility Study of Patient Specific QA Using Gafchromic Film of Dynamic Feathering in Junctions of Craniospinal Irradiation

Purpose: Cranio-spinal irradiation is the most complicated format of the conventional external beam radiation therapy because it involves matches of non-coplanar beams which are susceptible to daily setup errors. This study explores the efficacy of Gafchromic film dosimetry to quantitatively verify the junctions for cranio-spinal radiation feathered with field in field technique. Methods: 15cm in thickness of solid water phantom was scanned vertically and exported to the Pinnacle TPS as primary phantom data set. A patient cranio-spinal plan, consisted of two bilateral whole brain beams dynamically matched with a posterior spinal beam using field in field technique, was transferred to the phantom and recalculated for one fraction with set monitor units identical to the original plan. Next, planar dose distribution on the phantom was exported to the FilmQA Pro 2013 software (Ashland, Inc.) in binary format for comparison with the measured dose distribution. An EBT2 film was sandwiched in the middle of the phantom and the phantom was set up according to the QA plan based on the room laser system. The shifts instructions associated with the patient original plan were made and the beams from the patient original plan delivered to the solid water phantom via the record and verify system in QA mode. The dose distribution from the measured film was compared with the planned reference distribution using gamma analysis and profile comparison. Results: Gamma passing rate of 91 % with DTA 3mm and 5% dose difference was obtained within the junction region, significantly greater passing rate above 95 % was obtained in the homogeneous region of the brain field. Conclusion: This study confirms that Gafchromic film dosimetry can be used to validate the efficacy of FIF feathering technique for cranio-spinal treatment. FIF technique with Gafchromic dosimetry may now be the new standard for delivering efficient and accurate cranio-spinal radiation with confidence.

60 APPLIED LIFE SCIENCES↗

SU-E-T-205: Improving Quality Assurance of HDR Brachytherapy: Verifying Agreement Between Planned and Delivered Dose Distributions Using DICOM RTDose and Advanced Film Dosimetry

Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy. Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film dosimetry and gamma comparison to DICOM RTDose files has been demonstrated as suitable to fulfil this need.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-576: Evaluation of Patient Specific VMAT QA Using Dynalog Files and Treatment Planning System

Purpose: This research investigates the use of Mult-ileaf Collimator (MLC) dynalog files to modify a Volumetric Arc Therapy (VMAT) DICOM Radiotherapy Treatment file from the Treatment Planning System (TPS) for quality assurance and treatment plan verification. Methods: Actual MLC positions and gantry angles where retrieved from the MLC Dynalog files of an approved and treated VMAT plan. The treatment machine used was a Novalis TX linac equipped with high definition MLC. The DICOM RT file of the plan was exported from the TPS (Eclipse, Varian Medical Systems) and the actual MLC leaf positions and gantry angles were inserted in place of the planned positions for each control point. The modified DICOM RT file was then imported back into the TPS where dose calculations were performed. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% and 2mm-2% criteria. A 2D gamma was also calculated using dose measurements on the Delta4 (Sandidose) phantom. Results: A 3D gamma was calculated in Verisoft at 3mm-3% of 99.5% and at 2mm-2% of 99.2%. The pretreatment verification on the Delta4 yielded a 2D gamma at 3mm-3% of 97.9% and at 2mm-2% of 88.5%. The dose volume histograms of the approved plan and the dynalog plan are virtually identical. Conclusion: Initial results show good agreement of the dynalog dose distribution with the approved plan. Future work on this research will aim to increase the number of patients and replace the planned fractionated dose per control point with the actual fractionated dose.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-641: Development and Verification of Automatic Reading Dose of Interest From Eclipse's DVH

Purpose: According to clinical and research requirement, we develop a function of automatic reading dose of interest from dose volume histogram(DVH), to replace the traditional method with a mouse one by one point, and it's also verified. Methods: The DVH automatic reading function will be developed in an in-house developed radiotherapy information management system(RTIMS), which is based on Apache+PHP+MySQL. A DVH ASCII file is exported from Varian Eclipse V8.6, which includes the following contents: 1. basic information of patient; 2. dose information of plan; 3. dose information of structures, including basic information and dose volume data of target volume and organ at risk. And the default exported dose volume data also includes relative doses by 1% step and corresponding absolute doses and cumulative relative volumes, and the volumes are 4 decimal fraction. Clinically, we often need read the doses of some integer percent volumes, such as D50 and D30. So it couldn't be directly obtained from the above data, but we can use linear interpolation bye the near volumes and doses: Dx=D2−(V2−Vx)*(D2−D1)/(V2−V1), and program a function to search, read and calculate the corresponding data. And the doses of all preseted volume of interest of all structures can be automatically read one by one patient, and saved as a CSV file. To verify it, we select 24 IMRT plans for prostate cancer, and doses of interest are PTV D98/D95/D5/D2, bladder D30/D50, and rectum D25/D50. Two groups of data, using the automatic reading method(ARM) and pointed dose method(PDM), are analyzed with SPSS 16. The absolute difference=D-ARM-D-PDM, relative difference=absolute difference*100%/prescription dose(7600cGy). Results: The differences are as following: PTV D98/D95/D5/D2: −0.04%/− 0.04%/0.13%/0.19%, bladder D30/D50: −0.02%/0.01%, and rectum D25/D50: 0.03%/0.01%. Conclusion: Using this function, the error is very small, and can be neglected. It could greatly improve the efficiency of clinical work. Project supported by the National Natural Science Foundation of China (Grant No.81101694)

60 APPLIED LIFE SCIENCES↗

MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.

60 APPLIED LIFE SCIENCES↗

WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

60 APPLIED LIFE SCIENCES↗

SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.

60 APPLIED LIFE SCIENCES↗

SU-E-T-596: P3DVHStats - a Novel, Automatic, Institution Customizable Program to Compute and Report DVH Quantities On Philips Pinnacle TPS

Purpose: To implement a novel, automatic, institutional customizable DVH quantities evaluation and PDF report tool on Philips Pinnacle treatment planning system (TPS) Methods: An add-on program (P3DVHStats) is developed by us to enable automatic DVH quantities evaluation (including both volume and dose based quantities, such as V98, V100, D2), and automatic PDF format report generation, for EMR convenience. The implementation is based on a combination of Philips Pinnacle scripting tool and Java language pre-installed on each Pinnacle Sun Solaris workstation. A single Pinnacle script provide user a convenient access to the program when needed. The activated script will first export DVH data for user selected ROIs from current Pinnacle plan trial; a Java program then provides a simple GUI interface, utilizes the data to compute any user requested DVH quantities, compare with preset institutional DVH planning goals; if accepted by users, the program will also generate a PDF report of the results and export it from Pinnacle to EMR import folder via FTP. Results: The program was tested thoroughly and has been released for clinical use at our institution (Pinnacle Enterprise server with both thin clients and P3PC access), for all dosimetry and physics staff, with excellent feedback. It used to take a few minutes to use MS-Excel worksheet to calculate these DVH quantities for IMRT/VMAT plans, and manually save them as PDF report; with the new program, it literally takes a few mouse clicks in less than 30 seconds to complete the same tasks. Conclusion: A Pinnacle scripting and Java language based program is successfully implemented, customized to our institutional needs. It is shown to dramatically reduce time and effort needed for DVH quantities computing and EMR reporting.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-773: Use of a Commercial TPS for Deriving Exit Dose Distribution for Patient Specific QA with An EPID

Purpose: A method to derive exit dose distributions with a commercial treatment planning system for comparison to Epid measured doses. Methods: In contrast to published methods, we present an approach that uses a treatment planning system (Raystation, Raysearch) to calculate exit dose patterns based on a modified patient CT dataset. The EPID is assumed as water equivalent and therefore is represented as water filled ring in the images. This is done by: -Export a renamed copy of the patient CT and plan data set. —Manipulate the CT-data to a field of view of 1000 mm. — Insert the water filled cylinder ring, centered to the target point. — Manipulate plan file with the new target and dose prescription point. — Import and recalculate dose on the manipulated data set. — Export and extract exit field dose matrix from the cylinder (optional entrance dose). — Calibrate matrix to size and rebin data from the cylinder to EPID equivalent data. — Correct Epid measurement for scatter, position and field size. -Evaluate and compare data in Verisoft (PTW). Data manipulation and extraction is done by a simple tool (IDL, Exelis). Results: This method was tested on a Siemens Artiste 6MV for field sizes up to 27×27cm2 limited by used geometry and EPID size. First phantom measurements show good results for fields up to 20×20cm (pass rate > 95% for 3%, 3mm Gamma index) while larger fields have higher discrepancies towards the field edges. This might Result from off axis softening of the beam and the higher sensitivity of the detector to beam scatter. Conclusion: This method might simplify the use of exit dosimetry with the EPID for patient specific QA as it uses the dose calculation of a commercial treatment planning system. The concept was proven by phantom data sets, giving acceptable results.

60 APPLIED LIFE SCIENCES↗