Test-Derived Effective Emittance for Cassini MLI Blankets and Heat Loss Characteristics in the Vicinity of Seams

Multilayer insulation (MLI) blankets on the Cassini spacecraft will experience temperatures in the wide range of -200 to 360°C. Besides reducing heat loss, the MLI blankets will also serve, with standoffs, the purpose of micrometeoroid protection. Four major blanket layup configurations ??will be utilized on Cassini. Since definitive thermal properties for these layups were not available, thermal vacuum tests were conducted for their determination.

multilayer↗

VO 2 -based Thermochromic Variable Emittance Coating

As NASA’s Artemis program requirements become increasingly challenging for thermal control, novel passive thermal control solutions are needed to enable lunar surface and lunar transit operations. A thermochromic coating which changes its heat rejection with temperature could eliminate the need for dual loop thermal control architecture in human spacecraft and could reduce or eliminate the need for survival heaters in robotic spacecraft. The variable heat rejection is accomplished by incorporating a vanadium dioxide (VO 2 ) layer into a multilayer coating stack up. Intrinsically, VO 2 changes from an insulator to a metal at 68 °C, so a tungsten dopant is introduced to reduce the transition temperature to room temperature or below. This project is focused on developing a process for doping the VO 2 to achieve the desired transition temperature

Sydney Taylor↗

High efficiency radioisotope thermophotovoltaic prototype generator

A radioisotope thermophotovoltaic generator space power system (RTPV) is lightweight, low-cost alternative to the present radioisotope thermoelectric generator system (RTG). The fabrication of such an RTPV generator has recently become feasible as the result of the invention of the GaSb infrared sensitive photovoltaic cell. Herein, we present the results of a parametric study of emitters and optical filters in conjuction with existing data on gallium antimonide cells. We compare a polished tungsten emitter with an Erbia selective emitter for use in combination with a simple dielectric filter and a gallium antimonide cell array. We find that the polished tungsten emitter is by itself a very selective emitter with low emissivity beyond 4 microns. Given a gallium antimonide cell and a tungsten emitter, a simple dielectric filter can be designed to transmit radiant energy below 1.7 microns and to reflect radiant energy between 1.7 and 4 microns back to the emitter. Because of the low long wavelength emissivity associated with the polished tungsten emitter, this simple dielectric filter then yields very respectable system performance. Also as a result of the longer wavelength fall-off in the tungsten emissivity curve, the radiation energy peak for a polished tungsten emitter operating at 1300 K shifts to shorter wavelengths relative to the blackbody spectrum so that the radiated energy peak falls right at the gallium antimonide cell bandedge. The result is that the response of the gallium antimonide cell is well matched to a polished tungsten emitter. We propose, therefore, to fabricate an operating prototype of a near term radioisotope thermophotovoltaic generator design consisting of a polished tungsten emitter, standard gallium antimonide cells, and a near-term dielectric filter. The Jet Propulsion Laboratory will design and build the thermal cavity, and JX Crystals will fabricate the gallium antimonide cells, dielectric filters, and resultant receiver panels. With 250 Watts of heat input, we expect this prototype to produce over 300 Watts of electrical energy output for a system energy conversion efficiency of over 12%. This low risk, near term design provides advances relative to present radioisotope thermophotovoltaic generators and has the additional advantage of allowing component and system development and testing to begin immediately. Improved cells and filters can easily be incorporated in this baseline system if they should become available in the future.

Avery, James E.↗

DETERMINATION OF EMISSIVITY OF MATERIALS.

During the third quarter of the contractual year of Contract NASW-104 for the determination of emissivity of materials, the emittance of nine specimens was measured at temperatures ranging up to 2200F and at pressures averaging 10(exp -8) mm Hg. The materials tested included columbium, columbium with an oxidized surface, molybdenum, graphite varnish on Type 310 stainless steel, stainless steel with an oxidized surface, and platinum black. In the spectral emittance rig, spectral as well as total emittance was measured on three specimens and total emittance only was measured on a fourth. In the total emittance rig, total emittance data was obtained on five specimens. Two of the specimens were endured. Investigations were made concerning the operational characteristics of both rigs in order to eliminate possible sources of error in the data. On the spectral emittance rig, tests were conducted to determine the exact magnitude of any error introduced in the spectral emittance values by beam intermixing resulting from imperfections in the optical system. On the total emittance rig, work was concentrated on the determination of the relative accuracy of the chromel-alumel and platinum-platinum 10% rhodium thermocouples used to measure the temperature of the specimen.

Emission↗

Impact of Thermochromic Coatings on Thermal Management for Human Spacecraft Applications

Thermochromic variable emittance coatings (VECs) allow for passive, dynamic thermal management of space vehicles due to their temperature dependent optical properties. Ideally, a thermochromic material should exhibit low mid-IR emissivity for lower temperatures and switch to high mid-IR emissivity for higher temperatures; one promising material that demonstrates these characteristics is Lanthanum Strontium Manganite (LSM). The transition temperatures of LSM are dependent on the Lanthanum-to-Strontium ratio x, La1-xSrxMnO3. La0.8Sr0.2MnO3, which has an emittance of 0.5 for < 270 K, then a linear increase in emittance to 0.8 over an increase of 70 K where it will saturate at ~340K, is commonly utilized but this is tunable by changing the Sr concentration. The tunability of the transition temperature range of LSM motivates a need to understand the optimal thermal transition range for human spacecraft. Additionally, LSM has high solar absorptance and to combat this issue the VEC will be micropatterned on top of a highly solar reflective layer of Barium Sulfate (BaSO4). Consequently, this work will elucidate the tradeoffs between solar absorptance and variable emittance for this technology since the micropattern adversely couples the solar absorptance to the mid-IR emittance. This work develops a computational model using Thermal Desktop to study the utility of VECs on human spacecraft, such as Orion, subjected to mission phases such as lunar transit and Gateway docking. The model considers both external heat loads, from solar irradiation and planetary IR, as well as vehicle heat loads, from avionics and crew, as an input into the body mounted thermochromic radiators. There are several design targets for VECs, i.e. achieving the largest change in emittance, finding the optimal temperature range for the transition, and achieving the highest emittance in the high temperature phase. This work prioritizes these design targets for LSM to achieve the optimal heat rejection for a human spacecraft. The VECs are compared with static emittance coatings and the efficiency gains are quantified. Thermochromic VECs will ultimately lead to simplifications of active cooling systems which synergistically correlates to mass reduction and less energy consumption for space vehicles.

Joseph Peoples↗

Reactor core length, externally configured thermionic converter.

Results of testing a converter having an external emitter configuration for 190 hours using RF induction heating. The converter was assembled with a rhenium emitter, 25.4 cm long, having a 91.2 sq cm emitting area, and a niobium collector with a molybdenum coating to improve its electronic property. The collector was water-cooled. The test included: static power output measurements, dynamic characteristics, and the effects of the temperature distribution along the emitter. The maximum power output achieved from the converter at an emitter temperature of 1942 K was 178 W at 0.48 V output, with a power density of 1.95 W/sq cm and an efficiency of 5.5%. The static characteristics also indicated that, with a constant power input, the converter power output does not vary with the output voltage as a result of self-adjustment of the emitter temperature. An investigation of the effects of the temperature distribution along the emitter length showed a 33% improvement in the converter output power with a flattening of the emitter temperature.

Shimada, K.↗

Direct emissivity measurements on liquids and corrections to multi-color pyrometers

Optical pyrometry provides a means for non-contact temperature measurements whose accuracy depends on the accuracy with which specimen emittance is known. Two methods for obtaining the required emittance data are discussed in which the emittance is determined from measurements of the wavelength or polarization dependence of light emitted by the specimen. The spectral technique, multi-color pyrometry, yields apparent values for specimen emittance and temperature from emitted intensity measurements at two or more wavelengths. Emittance corrections cannot be eliminated by increasing the number of spectral intensity measurements required by an n-color pyrometer. Even if this were possible, the accuracy of temperature measurements by n-color pyrometry decreases with n such that pyrometers that require four intensity measurements would be impractical. In contrast, emittance values and corrections for one-color pyrometers can be accurately measured by the polarized light technique. The polarized light technique involves measurement of the degree of polarization for light emitted at an angle of 45 deg to the specimen normal. The reflectivities (r) for light polarized parallel (p) and normal (n) to the plane of emission are related by r(p) = r(n) squared. This leads to a simple relation between the intensity ratio for light emitted in the two polarized states and the emittance, i.e., e(n) = 2 - I(p)/I(n). The true specimen temperature is also obtained if absolute intensities are measured. Delvelopment of the polarized light technique in combination with one-color optical pyrometry is recommended to achieve accurate non-contact temperature measurements on liquids.

Nordine, Paul C.↗