Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emergency generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The locational value of distributed energy resources: A parcel-level evaluation of solar and wind potential in New York state

We report distributed energy resources (DERs) are poised to play a significant role in evolving power systems because of their flexibility to be sited in areas of high value to the grid. Traditional DER compensation frameworks, specifically net energy metering (NEM), inadequately communicate differences in the locational and temporal value of DER generation to the grid. As a transition from NEM, New York State's (NYS's) Value of Distributed Energy Resources (VDER) framework provides a methodology for calculating different value components that DERs offer the grid. To study the impacts of VDER frameworks on DER deployment, we developed a model to assess the value of distributed solar and wind systems configured as either a behind-the-meter system or a front-of-the-meter system for each parcel of land in NYS. Using parcel-level granularity, we can closely evaluate DER locational value and siting availability, particularly in urban and suburban settings. Our analysis finds while most DER generators would be modestly compensated for deferred transmission and distribution infrastructure upgrades (~0.01 $\$$/kWh for solar PV), a subset of projects receive significant value from this component (0.035 to 0.089 $\$$/kWh for top 5% of parcels for solar PV). Finally, our analysis finds VDER provides less overall compensation than NEM to the average DER generator, however, it increases access to compensation for front-of-the-meter DERs - a large and emerging market.

14 SOLAR ENERGY↗

Molecular Transducers of Physical Activity Consortium (MoTrPAC): Mapping the Dynamic Responses to Exercise

Exercise provides a robust physiological stimulus that evokes cross-talk between a wide range of tissues via hormonal, cellular and molecular signals that when repeated regularly over time (i.e., training) improves physiological capacity, benefits numerous organ systems and decreases the risk for premature mortality. In spite of its fundamental importance, a gap remains in identifying the detailed molecular signals and responses to exercise and its benefits for health and disease prevention. To further knowledge in this emerging area, the Molecular Transducers of Physical Activity Consortium (MoTrPAC) was established to generate a molecular map of the effects of acute and chronic exercise. MoTrPAC investigators are conducting preclinical and clinical studies to better understand the systemic effects of exercise across multiple tissues. The preclinical studies were performed on more than 700 rats with the analysis of twenty or more organs per rat. The clinical study involves a large cohort of ~2600 individuals with a range of ages and fitness levels (untrained, trained, highly trained) who will be evaluated physiologically and by molecular probing of blood, muscle and adipose tissues before and after acute and chronic endurance or resistance exercise. Multi-omic analyses (genomics, epigenomics, transcriptomics, proteomics and metabolomics/lipidomics) will be performed followed by state-of-the-art bioinformatics to create a molecular map of exercise. This mapping project will provide a public database that is expected to enhance our understanding of the health benefits of physical activity in many organ systems and potentially provide insight into mitigating diseases through activity.

Sanford, James A.↗

Modern deep neural networks for Direct Normal Irradiance forecasting: A classification approach

The escalating energy demand and the adverse environmental impacts of fossil-fuel use necessitate a shift towards cleaner and renewable alternatives. Concentrated Solar Power (CSP) technology emerges as a promising solution, offering a carbon-free alternative for power generation. The efficiency and profitability of CSP depend on the Direct Normal Irradiance (DNI) component of solar radiation; hence, accurate DNI forecasting can help optimize CSP plants’ operations and performance. The unpredictable nature of weather phenomena, particularly cloud cover, introduces uncertainty into DNI projections. Existing DNI forecasting models use meteorological factors, which are both challenging to estimate numerically over short prediction windows and expensive to model through data at a sufficiently high spatial and temporal resolution. This research addresses the challenge by presenting a novel approach that formulates DNI prediction as a multi-class classification problem, departing from conventional regression-based methods. The primary objective of this classification framework is to identify optimal periods aligning with specific operational thresholds for CSP plants, contributing to enhanced dispatch optimization strategies. We model the DNI classification problem using four advanced deep neural networks – rectified linear unit (ReLU) networks, 1D residual networks (ResNets), bidirectional long short-term memory (BiLSTM) networks, and transformers – achieving accuracies up to 93.5% without requiring meteorological parameters.

14 SOLAR ENERGY↗

Digital light processing of porous LLZTO scaffolds for Li-garnet solid-state batteries

Li 7 La 3 Zr 2 O 12 (LLZO)-based solid-state electrolytes (SEs) are promising materials for next-generation solid-state batteries. In this work, digital light processing (DLP), an emerging additive manufacturing technology, is employed to produce porous Ta-doped LLZO (LLZTO) scaffolds. The self-standing scaffolds are 100 μm thick and have 40% porosity. The scaffolds demonstrate symmetric cell cycling stability exceeding 1,500 h at 0.1 mA/cm2 current density, with a capacity of 0.1 mAh/cm 2 (1 h for each half cycle). At higher current densities, reversible soft shorts frequently happen, while immediate hard shorts are prevented due to Li dendrite growth being hindered by the tortuous pore network. In addition to the cycling stability, the phase stability of LLZTO is investigated during the post-printing thermal process for printing resin removal. We discovered that the LLZTO partially decomposes into Li 2 Zr 2 O 7 and other impurity phases from 400°C to 800°C, but the pure LLZTO phase is restored upon the completion of resin removal beyond 800°C.

Li-metal anode↗

Near-Infrared Emission from Sulfur Heteroatom Defects in Single-Walled Carbon Nanotubes

Quantum defects introduced into single-walled carbon nanotubes (SWCNTs) that support near-infrared emission are promising candidates for many applications. Here, we present a type of quantum defect in which sulfur atoms are incorporated into the crystal lattice of SWCNTs through their reactions with a mild reducing agent, sodium dithionite. When radical anions generated by sodium dithionites react with (6,5)-SWCNTs, two new emission features emerge at 1120 and 1250 nm. Comparing these spectral features with density functional theory calculation results, we attribute them to defects with episulfide or thioether structures. Here, by investigating the influences of reaction conditions including reactant concentration, light irradiation, and solvent type, we identify the reaction mechanism between SWCNTs and sodium dithionite and achieve good control over defect densities. Due to the intrinsic reactivity of sulfur species, the sulfur-containing quantum defects discovered here may facilitate the introduction of more complex and functionally diverse moieties into SWCNTs.

Anions↗

Hydrological Perspectives on Integrated, Coordinated, Open, Networked (ICON) Science

Hydrologic sciences depend on data monitoring, analyses, and simulations of hydrologic processes to ensure safe, sufficient, and equal water distribution. These hydrologic data come from but are not limited to primary (lab, plot, and field experiments) and secondary sources (remote sensing, UAVs, hydrologic models) that typically follow FAIR Principles (Findable, Accessible, Interoperable, and Reusable: (go-fair.org)). Easy availability of FAIR data has become possible because the hydrology-oriented organizations have pushed the community to increase coordination of the protocols for generating data and sharing model platforms. In addition, networking at all levels has emerged with an invigorated effort to activate community science efforts that complement conventional data collection methods. However, it has become difficult to decipher various complex hydrologic processes with increasing data. Machine learning, a branch of artificial intelligence, provide more accurate and faster alternatives to better understand different hydrological processes. The Integrated, Coordinated, Open, Networked (ICON) framework provides a pathway for water users to include and respect diversity, equity, and inclusivity. In addition, ICONs support the integration of peoples with historically marginalized identities into this professional discipline of water sciences. This article comprises three independent commentaries about the state of ICON principles in hydrology and discusses the opportunities and challenges of adopting them.

(ICON) principles to address↗

Domain-dependent strain and stacking in two-dimensional van der Waals ferroelectrics

Van der Waals (vdW) ferroelectrics have attracted significant attention for their potential in next-generation nano-electronics. Two-dimensional (2D) group-IV monochalcogenides have emerged as a promising candidate due to their strong room temperature in-plane polarization down to a monolayer limit. However, their polarization is strongly coupled with the lattice strain and stacking orders, which impact their electronic properties. Here, we utilize four-dimensional scanning transmission electron microscopy (4D-STEM) to simultaneously probe the in-plane strain and out-of-plane stacking in vdW SnSe. Specifically, we observe large lattice strain up to 4% with a gradient across ~50 nm to compensate lattice mismatch at domain walls, mitigating defects initiation. Additionally, we discover the unusual ferroelectric-to-antiferroelectric domain walls stabilized by vdW force and may lead to anisotropic nonlinear optical responses. Our findings provide a comprehensive understanding of in-plane and out-of-plane structures affecting domain properties in vdW SnSe, laying the foundation for domain wall engineering in vdW ferroelectrics.

42 ENGINEERING↗

Atomate2: modular workflows for materials science

High-throughput density functional theory (DFT) calculations have become a vital element of computational materials science, enabling materials screening, property database generation, and training of “universal” machine learning models. While several software frameworks have emerged to support these computational efforts, new developments such as machine learned force fields have increased demands for more flexible and programmable workflow solutions. This manuscript introduces atomate2, a comprehensive evolution of our original atomate framework, designed to address existing limitations in computational materials research infrastructure. Key features include the support for multiple electronic structure packages and interoperability between them, along with generalizable workflows that can be written in an abstract form irrespective of the DFT package or machine learning force field used within them. Our hope is that atomate2's improved usability and extensibility can reduce technical barriers for high-throughput research workflows and facilitate the rapid adoption of emerging methods in computational material science.

97 MATHEMATICS AND COMPUTING↗

Theoretical formulation of phase space microbunching instability in the presence of intrabeam scattering for single-pass or recirculation accelerators

Microbunching instability (MBI) has been one of the most challenging issues in designs of high-brightness beam transport lines for single-pass or recirculating accelerators. Although the intrabeam scattering (IBS) has long been studied in lepton or hadron storage rings as a slow diffusion process or in high-intensity proton linear accelerators as one mechanism for the beam halo, the effects of IBS on single-pass or recirculating electron accelerators have drawn attention only in the recent two decades due to emergence of linac-based or energy-recovery-linac-based fourth-generation light sources, which require high-quality electron beams during the beam transport. In this paper we develop a theoretical formulation of microbunching instability in the presence of IBS for single-pass or recirculation accelerators. To quantify MBI with inclusion of IBS, we start from the Vlasov-Fokker-Planck (VFP) equation, combining both collective interactions and incoherent IBS effects. The linearized VFP equation and the corresponding friction and diffusion coefficients are derived. The evolutions of the resultant density and energy modulations are formulated as a set of coupled integral equations. The theoretical formulation is then applied to a recirculating beamline design. The results from the semianalytical calculation are compared and show good agreement with massive particle tracking simulations.

43 PARTICLE ACCELERATORS↗

Orbital gyrotropic magnetoelectric effect and its strain engineering in monolayer NbX 2

Electrical control of the orbital degrees of freedom is an important area of research in the emerging field of "orbitronics.'' Orbital gyrotropic magneto-electric effect (OGME) is the generation of an orbital magnetization in a nonmagnetic metal by an applied electric field. Here, we show that strain induces a large GME in the monolayer NbX 2 (X = S, Se) normal to the plane, primarily driven by the orbital moments of the Bloch bands as opposed to the conventional spin magnetization, without any need for spin-orbit coupling. The key physics is captured within an effective two-band valley-orbital model and it is shown to be driven by three key ingredients: the intrinsic valley orbital moment, broken $C_{3z}$ symmetry, and strain-induced Fermi surface changes. The effect can be furthermore switched by changing the strain condition, with potential for future device applications.

2D materials↗

Fundamental bandwidth limits and shaping of frequency-modulated combs

Frequency-modulated (FM) combs based on active cavities like quantum cascade lasers have recently emerged as promising light sources in many spectral regions. Unlike passive modelocking, which generates amplitude modulation using the field’s amplitude, FM comb formation relies on the generation of phase modulation from the field’s phase. They can therefore be regarded as a phase-domain version of passive modelocking. However, while the ultimate scaling laws of passive modelocking have long been known—Haus showed in 1975 that pulses modelocked by a fast saturable absorber have a bandwidth proportional to effective gain bandwidth—the limits of FM combs have been much less clear. Here, we show that FM combs based on fast gain media are governed by the same fundamental limits, producing combs whose bandwidths are linear in the effective gain bandwidth. Not only do we show theoretically that the diffusive effect of gain curvature limits comb bandwidth, but we also show experimentally how this limit can be increased. By adding carefully designed resonant-loss structures that are evanescently coupled to the cavity of a terahertz laser, we reduce the curvature and increase the effective gain bandwidth of the laser, demonstrating bandwidth enhancement. Our results can better enable the creation of active chip-scale combs and be applied to a wide array of cavity geometries.

47 OTHER INSTRUMENTATION↗

Review of Marine Renewable Energy in Integrated Resource Plans

As part of a literature review of reference material for grid applications of marine hydrokinetic energy capture technologies, Pacific Northwest National Laboratory (PNNL) surveyed U.S. electric utility integrated resource plans for the mention or treatment of marine renewable energy technologies, principally wave energy, tidal energy, and offshore wind energy. This review offers a window into utility decision-making and data utilization with regard to these generating technologies. The report also offers perspectives on the relationship between traditional and emerging resource planning paradigms and metrics.

16 TIDAL AND WAVE POWER↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

TAUOLA update for decay channels with e + e – pairs in the final state

With the arrival of high luminosity B-factories like the Belle II experiment, τ decay measurements have become more precise than ever, allowing rarer processes to be explored, and finer details of τ decays to be studied. These are important to understand the spectrum of intermediate particles produced in τ decays. Therefore Monte Carlo generators, like the TAUOLA program, have to facilitate precision analysis as well as confront new models that constantly emerge with the availability of high statistics experimental data. New decay channels and models may lead to large variation of matrix elements size within the available phase space, as in the case when e + e - pairs are present in final state. It requires appropriate presampler of the phase space generator and a proper documentation to help users introduce their own models. While releasing a new update, it is important for the TAUOLA Monte Carlo library to maintain the general structure of the previous versions to preserve backward compatibility. The aim is to minimize changes from the user perspective. Finally, this paper presents a demonstration of new models implementation facilitated by the current update.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗