Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.↗

Adapting the Electron Beam from SEM as a Quantitative Heating Source for Nanoscale Thermal Metrology

The electron beam (e-beam) in the scanning electron microscopy (SEM) provides an appealing mobile heating source for thermal metrology with spatial resolution of ~1 nm, but the lack of systematic quantification of the e-beam heating power limits such application development. Here, we systemically study e-beam heating in LPCVD silicon nitride (SiN x ) thin-films with thickness ranging from 200 to 500 nm from both experiments and complementary Monte Carlo simulations using the CASINO software package. There is good agreement about the thickness-dependent e-beam energy absorption of thin-film between modeling predictions and experiments. Using the absorption results, we then demonstrate adapting the e-beam as a quantitative heating source by measuring the thickness-dependent thermal conductivity of SiN x thin-films, with the results validated to within 7% by a separate Joule heating experiment. The results described here will open a new avenue for using SEM e-beams as a mobile heating source for advanced nanoscale thermal metrology development.

42 ENGINEERING↗

Magnetospheric electrons

Coupling of source, transport, and sink processes produces a fairly accurate model for the macroscopic structure and dynamics of magnetospheric electrons. Auroral electrons are controlled by convective transport from a plasma sheet source coupled with a precipitation loss due to whistler and electrostatic plasma turbulence. Outer and inner zone electrons are governed by radial diffusion transport from convection and acceleration sources external to the plasmapause and by parasitic precipitation losses arising from cyclotron and Landau interactions with whistler and ion cyclotron turbulence.

Coroniti, F. V.↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

On the problems associated with the rapidly varying compact nonthermal sources

Difficulties and possible interpretations are discussed for observations of extragalactic compact nonthermal radio sources. The sources considered are those which have been identified optically with normal and peculiar galaxies, quasars, N galaxies, and BL Lacertae objects. Optical, infrared, and radio flux variations in different sources are noted along with difficulties associated with determining angular sizes from interferometric measurements. It is suggested that the ultimate origin of the infrared flux is probably a nonthermal synchrotron mechanism in some sources and absorption and reradiation of ultraviolet synchrotron radiation by dust in others. Model calculations of compact sources are reviewed, emphasizing equipartition of energy, total energies, the importance of the Compton effect, and sources which present severe difficulties for the theory of a canonical incoherent electron-synchrotron source.

Burbidge, G. R.↗

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Demonstration of the Mars Organic Molecule Analyzer (MOMA) on the ExoMars 2018 Rover

The Mars Organic Molecule Analyzer (MOMA) investigation is a key astrobiology experiment scheduled to launch on the joint ESA-Roscosmos ExoMars 2018 rover mission. MOMA will examine the chemical composition of geological samples acquired from depths of up to two meters below the martian surface, where fragile organic molecules may be protected from destructive cosmic radiation and/or oxidative chemical reactions. The heart of the MOMA mass spectrometer subsystem (i.e., MOMA-MS) is a miniaturized linear ion trap (LIT) that supports two distinct modes of operation to detect: i) volatile and semi-volatile, low-to-moderate mass organics (less than or equal to 500 Da) via pyrolysis coupled with gas chromatography mass spectrometry (pyr/GCMS); and, ii) more refractory, moderate-to-high mass compounds (up to 1000 Da) via laser desorption (LDMS) at ambient Mars pressures. Additionally, the LIT mass analyzer enables selective ion trapping via multi-frequency waveform ion excitation (e.g., stored waveform inverse Fourier transform, or SWIFT), and structural characterization of complex molecules using tandem mass spectrometry (MSIMS). A high-fidelity Engineering Test Unit (ETU) of MOMAMS, including the LIT subassembly, dual-gun electron ionization source, micropirani pressure gauge, solenoid-driven aperture valve, redundant detection chains, and control electronics, has been built and tested at NASA GSFC under relevant operational conditions (pressure, temperature, etc.). Spaceflight qualifications of individual hardware components and integrated subassemblies have been validated through vibration, shock, thermal, lifetime, and performance evaluations. The ETU serves as a pathfinder for the flight model buildup, integration and test, as the ETU meets the form, fit and function of the flight unit that will be delivered to MPS in late 2015. To date, the ETU of MOMA-MS has been shown to meet or exceed all functional requirements, including mass range, resolution, accuracy, instrumental drift, and Iimit-of-detection specifications, thereby enabling the primary science objectives of the MOMA investigation and ExoMars 2018 mission.

Mars Organic Molecule Analyzer↗

The electron-cyclotron maser instability as the source of solar type V continuum

In this paper, it is proposed that the electron-cyclotron (EC) maser instability can be the source of solar type V bursts. The propagation of electrons up an open field line is examined, and it is shown that the resultant distribution can be subject to the bump-in-tail (BIT) or the EC maser instabilities, or both. The characteristics of the emission from the BIT and EC maser instabilities when they are driven by such distributions are compared. It is proposed that type V bursts are produced by the coalescence of the upper hybrid waves produced by the maser instability, while type IIIs are produced by the BIT instability.

Winglee, R. M.↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

Transfer of polarized radiation in self-absorbed synchrotron sources. I - Results for a homogeneous source

The solution to the equation of transfer of polarized radiation in a steady-state homogeneous rarefied medium is applied to self-absorbed synchrotron sources. Relativistic electrons (independent of the presence of any cold plasma) can quite easily produce in such sources significant Faraday rotation and/or conversion of linear to circular polarization. Structural inhomogeneities do not obviate the importance of these phenomena in compact nonthermal sources. Contrary to the calculation of Pacholczyk and Swihart (1975), the circular polarization for a homogeneous source changes sign just below the self-absorption turnover as the source becomes opaque, even when polarization conversion dominates; however, for a physically realistic source, structural inhomogeneity may alter this behavior. The observational evidence bearing upon these effects is reviewed.

Jones, T. W.↗

Excitation of surface waves in 3D ion beam neutralization

Neutralization of beams with 2D and 3D geometries by the electrons emitted from an external source is studied using particle-in-cell simulations. Our work reveals that the high-energy electrons excite Trivelpiece–Gould (TG) surface waves in the beams with 3D axisymmetric geometries. These high-energy electrons are generated because of a large amplitude electrostatic solitary wave (ESW) that forms near the electron source and has an electric potential amplitude more than three times the electron thermal energy. Here, we also find that surface wave excitation only happens when the beam radius is large enough at the ion source to attract enough electrons that could form the large amplitude ESW. A comparison of the 3D TG surface wave dispersion relation with an expression for 2D surface waves reveals that they become excited in 3D axisymmetric but not in 2D planar beam because of a higher phase speed requirement in the latter case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of High-Z Converter into Full-scale Production Target for Accelerator-based Production of 99 Mo

NorthStar Medical Technologies is planning to produce the 99Mo isotope via the photonuclear route. The Rhodotron accelerator designed by IBA will be used as an electron-beam source. The Rhodotron is an efficient recirculating accelerator, providing low energy dispersion and a low-emittance electron beam. The nominal beam power is assumed to be 120 kW at 40 MeV. In photonuclear production of 99 Mo, a high-power electron beam impinges on a helium-cooled Mo disk target. Electrons are converted into photons through the Bremsstrahlung process. Consequently, high-energy photons interact with the target nuclei, producing 99 Mo through the 100 Mo(γ, n) 99 Mo reaction. Traditionally, photonuclear production is realized using high-Z material as the electron-to-photon converter. NorthStar plans not to use a high-Z converter in the initial production target design, but it may be interested in the increased production capabilities a high-Z converter can provide. The purpose of this report is to evaluate the advantages and disadvantages of incorporating a high-Z converter into the target design.

07 ISOTOPE AND RADIATION SOURCES↗

Simple ultraviolet calibration source with reference spectra and its use with the Galileo orbiter ultraviolet spectrometer

A simple compact electron impact laboratory source of UV radiation has been developed and is used to obtain calibrated optically thin VUV spectra and synthetic spectral models for important molecular band systems of H2, N2, and the n 1P0 Rydberg series of He. The relative spectral intensity of the electron impact source can be used as the primary calibration standard for VUV instrumentation in the 80-230 nm range and with FWHM of not less than 0.4 nm. The accuracy of the present method is 10 percent in the FUV and 20 percent in the EUV. Results for calibration of the Galileo orbiter ultraviolet spectrometer have been compared with those obtained using other methods.

Shemansky, D. E.↗

NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 20: Engineers as information processors: A survey of US aerospace engineering faculty and students

U.S. aerospace engineering faculty and students were surveyed as part of the NASA/DoD Aerospace Knowledge Research Project. Faculty and students were viewed as information processors within a conceptual framework of information seeking behavior. Questionnaires were received from 275 faculty members and 640 students, which were used to determine: (1) use and importance of information sources; (2) use of specific print sources and electronic data bases; (3) use of information technology; and (4) the influence of instruction on the use of information sources and the products of faculty and students. Little evidence was found to support the belief that instruction in library or engineering information use has significant impact either on broadening the frequency or range of information products and sources used by U.S. aerospace engineering students.

Holland, Maurita Peterson↗