Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Electrochemical Detection of the Molecules of Life

All forms of life on Earth contain cellular machinery that can transform and regulate chemical energy through metabolic pathways. These processes are oxidation-reduction reactions that are performed by four key classes of molecules: flavins, nicotinamaides, porphyrins, and quinones. By detecting the electrochemical interaction of these redox-active molecules with an electrode, a method of differentiating them by their class could be established and incorporated into future life-detecting missions. This body of work investigates the electrochemistry of ubiquitous molecules found in life and how they may be detected. Molecules can oxidise or reduce the surface of an electrode - giving or receiving electrons - and these interactions are represented by changes in current with respect to an applied voltage. This relationship varies with: electrolyte type and concentration, working electrode material, the redox-active molecule itself, and scan rate. Flavin adenine dinucleotide (FAD), riboflavin, nicotinamide adenine dinucleotide (NADH), and anthraquinone are all molecules found intracellularly in almost all living organisms. An organism-synthesised extracellular redox-active molecule, Plumbagin, was also selected as part of this study. The goal of this work is to detect these molecules in seawater and assess its application in searching for life on Ocean Worlds.

astrobiolog↗

Multimodal Neuroelectric Interface Development

This project aims to improve performance of NASA missions by developing multimodal neuroelectric technologies for augmented human-system interaction. Neuroelectric technologies will add completely new modes of interaction that operate in parallel with keyboards, speech, or other manual controls, thereby increasing the bandwidth of human-system interaction. We recently demonstrated the feasibility of real-time electromyographic (EMG) pattern recognition for a direct neuroelectric human-computer interface. We recorded EMG signals from an elastic sleeve with dry electrodes, while a human subject performed a range of discrete gestures. A machine-teaming algorithm was trained to recognize the EMG patterns associated with the gestures and map them to control signals. Successful applications now include piloting two Class 4 aircraft simulations (F-15 and 757) and entering data with a "virtual" numeric keyboard. Current research focuses on on-line adaptation of EMG sensing and processing and recognition of continuous gestures. We are also extending this on-line pattern recognition methodology to electroencephalographic (EEG) signals. This will allow us to bypass muscle activity and draw control signals directly from the human brain. Our system can reliably detect P-rhythm (a periodic EEG signal from motor cortex in the 10 Hz range) with a lightweight headset containing saline-soaked sponge electrodes. The data show that EEG p-rhythm can be modulated by real and imaginary motions. Current research focuses on using biofeedback to train of human subjects to modulate EEG rhythms on demand, and to examine interactions of EEG-based control with EMG-based and manual control. Viewgraphs on these neuroelectric technologies are also included.

Trejo, Leonard J.↗

Method and apparatus for measurement of trap density and energy distribution in dielectric films

Trap densities in dielectric films are determined by tunnel injection measurements when the film is incorporated in an insulated-gate field effect transistor. Under applied bias to the transistor gate, carriers (electrons or holes) tunnel into traps in the dielectric film. The resulting space charge tends to change channel conductance. By feeding back a signal from the source contact to the gate electrode, channel conductance is held constant, and by recording the gate voltage as a function of time, trap density can be determined as a function of distance from the dielectric-semiconductor interface. The process is repeated with the gate bias voltage at different levels in order to determine the energy distribution of traps as a function of distance from the interface.

Maserjian, J.↗

Linear charge coupled device detector array for imaging light propagating in an integrated thin-film optical waveguide

Device design, fabrication, and operation of a linear charge coupled device (CCD) detector array integrated with a thin film optical waveguide and applications of this structure to integrated optical signal processing and fiber optical communications were discussed. A two phase, overlapping-gate CCD is connected in parallel by means of a series of gates to an array of photodiodes. The photodiode provides an electrode free surface region so that a highly efficient waveguide detector coupling technique can be implemented. A thermally-oxidized layer of SiO2 forms an effective substrate for the optical waveguide.

Chen, C. L.↗

Tactile responses in the granule cell layer of cerebellar folium crus IIa of freely behaving rats

We recorded activity from the granule cell layer (GCL) of cerebellar folium Crus IIa as freely moving rats engaged in a variety of natural behaviors, including grooming, eating, and free tactile exploration. Multiunit responses in the 1000-4500 Hz range were found to be strongly correlated with tactile stimulation of lip and whisker (perioral) regions. These responses occurred regardless of whether the stimulus was externally or self-generated and during both active and passive touch. In contrast, perioral movements that did not tactually stimulate this region of the face (e.g., chewing) produced no detectable increases in GCL activity. In addition, GCL responses were not correlated with movement extremes. When rats used their lips actively for palpation and exploration, the tactile responses in the GCL were not detectably modulated by ongoing jaw movements. However, active palpation and exploratory behaviors did result in the largest and most continuous bursts of GCL activity: responses were on average 10% larger and 50% longer during palpation and exploration than during grooming or passive stimulation. Although activity levels differed between behaviors, the position and spatial extent of the peripheral receptive field was similar over all behaviors that resulted in tactile input. Overall, our data suggest that the 1000-4500 Hz multiunit responses in the Crus IIa GCL of awake rats are correlated with tactile input rather than with movement or any movement parameter and that these responses are likely to be of particular importance during the acquisition of sensory information by perioral structures.

Neurons/cytology/physiology↗

Development of a Cold-Walled Molten Regolith Electrolysis Reactor for Lunar Oxygen Production

On the lunar surface, production of commodi-ties to support human presence, such as water, food and oxygen, and sustain the growth of a per-manent outpostwill likely require the use oflocal resources. The moon is covered almost entirely withfragmented oxide minerals known as regolithhundreds of meter thick.As a resource, it is rich in oxygen (> 42 wt.%) bound in a solid state with a variety of metals. The molten regolith electrolysis (MRE)reactor is a promising technology for the production of gaseous oxygen from the lunar reg-olithin a simple, single-stepreaction that requires minimalconsumable materials, produces oxygen and metals with high electrical efficiency and high yields from any regolithcomposition.This process involvesmelting regolith to~1600°C then electro-lyzing the molten pool to separate metal and oxy-gen ions that are then collected as liquid metal and gaseous oxygen at the respective electrodes. Lab-scale demonstrations of the MRE technology have previously reliedon external heating sources to bring the entirety of the reactor up to the operating temperaturewhich creates corrosive interfaces be-tween the molten regolith and the containment ma-terial in the reactor, limiting the overall lifespan of a reactor[1]. The Gaseous Lunar Oxygen from Regolith Electrolysis (GaLORE) project is focused on the development of a “cold-walled” or “Joule-heated” reactor design in which an internal heating source is used to selectively melt a pool of regolith between the electrodes of the reactor, leaving a shell of solidified regolith between the molten pool and the containment vessel of the reactor. This next generation reactor concept has been under development as molten oxide electrolysis (MOE) by MIT and Boston Metal for the production of iron from pure ores for terrestrial application [2]. The GaLORE project in engaged in early development of the technology for use with varying lunar regolith compositionsin the lunar environment. Thermal modelling of a proposed cold-walledreac-tor design were used as a scaffold to develop pa-rameters for a feasible reactor shape and size as well as target energy consumption[3]. The current development effort for the cold-walled reactor de-sign will be presented as a trade study of the most promising techniques for melting regolithwithin the constraints imposed by the lunar environment.Heater devices are designed to accommodate lim-ited electrical power availabilityon the moon, a wide range of regolith compositions that may be seen on the moon, limited metals available for re-placing consumed parts,and the low thermal con-ductivity of granular regolith in vacuum.Heater de-vices will be down-selectedbased on performance measurements within the above operationalcon-straints,and selected devices will be integrated into a reactor with electrodes to begin producing oxygen. [1]Sibille,L.,Sadoway, D.R.,Sirk, A., Tripathy,P.,Melendez, O., Standish, E., Dominguez, J. A., Stefanescu, D.M.,Curreri, P.A., Poizeau,S.,2009. “Recent Advancesin Scale-up Development of Molten Regolith Electrolysis for Oxygen Production in support of a Lunar Base.”AIAA 2009-659, 47th AIAA Aerospace Sciences Meeting, 5 -8 January 2009, Orlando, FL. [2] Boston Metal, https://www.boston-metal.com/moe-technology/#moe-process[3]Schreiner, S.S.,Sibille, L., Dominguez, J.A., Hoffman, J.A., 2016. "A parametric sizing model for Molten Regolith Electrolysis reactors to pro-duce oxygen on the Moon." Advances in Space Research 57.,7,1585-1603.

K D Grossman↗

Development of an electrostatic positioner for space material processing

This paper describes an electrostatic positioning instrument which was developed at the Jet Propulsion Laboratory to enable experimenters to conduct containerless material science experiments in space. Samples that are to be studied are electrically charged and controlled by the electrostatic force produced by a set of properly arranged electrodes. Three different types of positioners are described, i.e., the dish type, the ring type, and the tetrahedral type. In all these systems, the positioning and the damping of the sample is accomplished by a feedback control system. The advantage of this electrostatic positioning method, in comparison to the other methods, such as acoustic and electromagnetic, lies in the fact that it can operate in a high vacuum and does not require the material to be electrically conductive as long as the material can carry a certain amount of charge.

Rhim, W. K.↗

The effect of microstructure and strength on the fracture toughness of an 18 Ni, 300 grade maraging steel

A 300 grade maraging steel was chosen as a vehicle by which to understand the inverse relationship between strength and toughness in high strength alloys such as the 18 Ni maraging steels. The 18 Ni, 300 grade maraging material was a commercial grade consumable-electrode, vacuum arc remelted heat obtained in the form of forged and annealed plate. The matrix contained a population of second-phase impurity inclusions which was a product of the casting and hot working processes. These inclusions did not change with subsequent precipitation hardening. Changes in microstructure resulting in strength increases were brought about by variations in aging temperature and time. Maximum strength was attained in the 300 grade maraging steel by aging at 427 C (800 F) for 100 hours. Tensile, fatigue precracked Charpy impact, and plane-strain fracture toughness tests were performed at room temperature, 20 C (68 F). With increasing strength the fracture toughness decreases as smaller and smaller inclusions act as sites for void initiation.

Psioda, J. A.↗

Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.

Source record↗

Welding arc and plasma studies using real time, multipass holographic interferometry

Flow visualization of the plasma process in a welding arc is being studied with a multipass Argon ion interferometer. High speed movies at 10,000 frames per/sec are taken. The multipass interferometer and several interferograms of the plasma near the electrode of the welding are given. Digitization of the fringes is currently done by hand.

Deason, Vance↗

Freeze Tape Casting of Functionally Graded Porous Ceramics

Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

Sofie, Stephen W.↗

In-Line Capacitance Sensor for Real-Time Water Absorption Measurements

A capacitance/dielectric sensor was designed, constructed, and used to measure in real time the in-situ water concentration in a desiccant water bed. Measurements were carried out with two experimental setups: (1) passing nitrogen through a humidity generator and allowing the gas stream to become saturated at a measured temperature and pressure, and (2) injecting water via a syringe pump into a nitrogen stream. Both water vapor generating devices were attached to a downstream vertically-mounted water capture bed filled with 19.5 g of Moisture Gone desiccant. The sensor consisted of two electrodes: (1) a 1/8" dia stainless steel rod placed in the middle of the bed and (2) the outer shell of the stainless steel bed concentric with the rod. All phases of the water capture process (background, heating, absorption, desorption, and cooling) were monitored with capacitance. The measured capacitance was found to vary linearly with the water content in the bed at frequencies above 100 kHz indicating dipolar motion dominated the signal; below this frequency, ionic motion caused nonlinearities in the water concentration/capacitance relationship. The desiccant exhibited a dielectric relaxation whose activation energy was lowered upon addition of water indicating either a less hindered rotational motion or crystal reorientation.

Nurge, Mark A.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

Plasma-enhanced chemical vapor deposition of multiwalled carbon nanofibers

Plasma-enhanced chemical vapor deposition is used to grow vertically aligned multiwalled carbon nanofibers (MWNFs). The graphite basal planes in these nanofibers are not parallel as in nanotubes; instead they exhibit a small angle resembling a stacked cone arrangement. A parametric study with varying process parameters such as growth temperature, feedstock composition, and substrate power has been conducted, and these parameters are found to influence the growth rate, diameter, and morphology. The well-aligned MWNFs are suitable for fabricating electrode systems in sensor and device development.

Nanotechnology/instrumentation/methods↗

Automatic Control of Arc Process for Making Carbon Nanotubes

An automatic-control system has been devised for a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. The control system includes a motor-driven screw that adjusts the distance between the electrodes. The system also includes a bridge circuit that puts out a voltage proportional to the difference between (1) the actual value of potential drop across the arc and (2) a reference value between 38 and 40 V (corresponding to a current of about 100 A) at which the yield of carbon nanotubes is maximized. Utilizing the fact that the potential drop across the arc increases with the interelectrode gap, the output of the bridge circuit is fed to a motor-control circuit that causes the motor to move the anode toward or away from the cathode if the actual potential drop is more or less, respectively, than the reference potential. Thus, the system regulates the interelectrode gap to maintain the optimum potential drop. The system also includes circuitry that records the potential drop across the arc and the relative position of the anode holder as function of time.

Scott, Carl D.↗

Experimental Setup for the Laboratory Investigation of Micrometeoroid Ablation Using a Dust Accelerator

A facility has been developed to simulate the ablation of micrometeoroids in laboratory conditions. An electrostatic dust accelerator is used to generate iron particles with velocities of 10-70 kilometers. The particles are then introduced into a chamber pressurized with a target gas, where the pressure is adjustable between 0.01 and 0.5 Torr, and the particle partially or completely ablates over a short distance. An array of biased electrodes above and below the ablation path is used to collect the generated ions/electrons with a spatial resolution of 2.6 centimeters along the ablating particles path, thus allowing the study of the spatiotemporal evolution of the process. For completely ablated particles, the total collected charge directly yields the ionization coefficient of a given dust material-target gas combination. The first results of this facility measured the ionization coefficient of iron atoms with N2, air, CO2, and He target gases for impact velocities greater than 20 kilometers per second, and are reported by Thomas et al. The ablation chamber is also equipped with four optical ports that allow for the detection of the light emitted by the ablating particle. A multichannel photomultiplier tube system is used to observe the ablation process with a spatial and temporal resolution of 0.64 centimeters and 90 nanoseconds. The preliminary results indicate that it is possible to calculate the velocity of the ablating particle from the optical observations, and in conjunction with the spatially resolved charge measurements allow for experimental validation of ablation models in future studies.

Thomas, Evan↗

Characterization of electrochemically deposited polypyrrole using magnetoelastic material transduction elements

Magnetoelastic alloy films have been used as a working electrode in an electrochemical cell. This material allows magnetic interrogation of electrochemical deposition. This technique was used to monitor the electrochemical deposition of polypyrrole by multisweep (CV) and potentiostatic methods. Since the determination of the mass-sensitive magnetoelastic film's resonance frequency is based on magnetic transduction, an inherent advantage of this method is that it requires no electrical connections other than the working lead of the potentiostat. Increases in pyrrole deposition correlated with a decrease in the peak resonance frequency of the magnetoelastic alloy. This technique provides a novel approach by which one can monitor electrochemical processes.

NASA Discipline Life Sciences Technologies↗

Acceleration processes in the quasi-steady magnetoplasmadynamic discharge

The flow field characteristics within the discharge chamber and exhaust of a quasi-steady magnetoplasmadynamic (MPD) arcjet were examined to clarify the nature of the plasma acceleration process. The observation of discharge characteristics unperturbed by insulator ablation and terminal voltage fluctuations, first requires the satisfaction of three criteria: the use of refractory insulator materials; a mass injection geometry tailored to provide propellant to both electrode regions of the discharge; and a cathode of sufficient surface area to permit nominal MPD arcjet operation for given combinations of arc current and total mass flow. The axial velocity profile and electromagnetic discharge structure were measured for an arcjet configuration which functions nominally at 15.3 kA and 6 g/sec argon mass flow. An empirical two-flow plasma acceleration model is advanced which delineates inner and outer flow regions and accounts for the observed velocity profile and calculated thrust of the accelerator.

Boyle, M. J.↗