Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Report for ARPA-E NODES "Real-Time Optimization and Control of Next-Generation Distribution Infrastructure" Project

The project examined next-generation power distribution systems with high levels of power- electronics-interfaced distributed energy resources (DERs) that include: renewable energy systems (RESs), energy-storage devices, electric vehicles, fuel cells, small-scale diesel generators, and controllable loads. The project developed a comprehensive distribution- network management framework that unifies real-time voltage and frequency control with network-wide energy management under an integrated framework. The aim of the project was to: i) systematically optimize network-wide operation and congruently regulate voltages and frequency in the face of high volatility induced by rapidly varying RES and uncontrolled loads; ii) facilitate high renewable integration beyond 50% on an energy basis; iii) meet power-quality requirements and operational constraints; and, iv) respect response, ramp- time, and hold-time requirements for synthetic frequency and regulating reserves via fast- and longer-term dynamic energy management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

Electric Vehicle Charging Management in Smart Energy Communities to Increase Renewable Energy Hosting Capacity

Abnormal climates due to global warming have emerged as a big concern in the global community. To mitigate climate change and achieve sustainability, distributed energy resources (DERs), including solar and wind, have been recently deployed in power systems. As the penetration level of DERs has increased, however, it caused a multitude of issues in the power systems, such as voltage fluctuation in the distribution network limiting renewable hosting capacity. On the other hand, the electric vehicle (EV) industry is rapidly growing to facilitate the transition to a carbon-neutral community, illuminating the potential of EVs as a flexible grid asset to mitigate some of the issues and improve grid operation, if properly exploited. To explore the potential of EVs, this paper proposes an EV scheduling strategy. By using an optimal EV charging scheduling proposed, distribution system operators (DSOs) can minimize their operating costs and stably operate the system with a high level of DERs. To validate the method, a modified IEEE 33-bus system with DERs is developed. The case study shows the proposed scheduling strategizes EV charging to reduce the cost of PV curtailment. In the study, the method outperforms the renewable-only case with curtailment by 4.97% in DSO cost. It also demonstrates its potential to increase the renewable hosting capacity by harmonizing EV charging with renewables.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

ARIES: Advanced Research on Integrated Energy Systems Research Plan

The Advanced Research on Integrated Energy Systems (ARIES) platform is one of the most powerful research environments anywhere for addressing the speed and scale of change on power systems. This research plan details ARIES capabilities, current and upcoming, and how they relate to objectives for advanced energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peer-to-Peer Energy Systems for Connected Communities: A Review of Recent Advances and Emerging Challenges

After a century of relative stability of the electricity industry, extensive deployment of distributed energy resources and recent advances in computation and communication technologies have changed the nature of how we consume, trade, and apply energy. The power system is facing a transition from its traditional hierarchical structure to a more deregulated model by introducing new energy distribution models such as peer-to- peer (P2P) sharing for connected communities. The proven effectiveness of P2P sharing in benefiting both prosumers and the grid has been demonstrated in many studies and pilot projects. However, there is still no extensive implementation of such sharing models in today’s electricity markets. This paper aims to shed some light on this gap through a comprehensive overview of recent advances in the P2P energy system and an insightful discussion of the challenges that need to be addressed in order to establish P2P sharing as a viable energy management option in today’s electricity market. To this end, in this article, we provide some background on different aspects of P2P sharing. Then, we discuss advances in P2P sharing through a systematic domain-based classification. We also review different pilot projects on P2P sharing across the globe. Finally, we identify and discuss a number of challenges that need to be addressed for scaling up P2P sharing in the electricity market followed by concluding remarks at the end of the paper.

Tushar, Wayes↗

Cybersecurity Assessment for a Behind-the-Meter Solar PV System: A Use Case for the DER-CF

The world's energy production is shifting toward lower-cost, cleaner, more efficient, and sustainable sources. The increasing numbers of distributed energy resources (DERs) are allowing for the rapid transformation of electric grids toward achieving the goal of energy decarbonization. Along with cleaner and more efficient energy, however, we must also aim for a secure energy future. Solar photovoltaic (PV) systems are an important part of this transition. This paper discusses a cybersecurity risk assessment for behind-the-meter DERs using a solar PV system as a use case of the Distributed Energy Resource Cybersecurity Framework (DER-CF) developed by the National Renewable Energy Laboratory. This poster presents a conference paper on the risk assessment processes and summarizes the DER-CF's use case recommendations to strengthen the cybersecurity posture of the electric grid.

cybersecurity↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Emerging Trends and Systemic Issues Influencing Today’s U.S. Electric Grid

With increasing shifts from vertically integrated to horizontally structured operations and from centralized to distributed electric power delivery, today’s electric power grid (the “grid”) operators and designers face the challenge of creating an architecture that accommodates a host of diverse requirements. The grid’s modes of operation must address concerns of reliability and stability, new deployments of renewable energy sources, threats from cyber-attacks and natural disasters, and increasingly distributed system operations. Grid modernization calls for a reliable, affordable, sustainable, agile, secure, and resilient grid. However, the modernization of the U.S. power grid is hampered by mounting complexity and diverging objectives from owners and operators and is consequently risky and fraught with potential missteps. Flawed architecture, design, and implementation will lead to stranded investments and lost opportunities. A principled approach to minimize risk and develop a robust grid of the future is to begin with a sound architecture for the grid to inform the design process. Architecture development starts with the context of influencing factors that provide constraints as well as driving goals. This report provides the context of emerging trends and cross-cutting systemic issues in the U.S. electric power grid and serves as a vital input for grid architecture development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Power Substations (SSPS): A Multi-Hierarchical Architecture from Substation to Grid Edge

With the growing deployment of distributed generation, or power electronic interfaced renewable energy and storage technologies, the nature and behavior of the grid is changing. Synchronous machine-driven asset contributions to the generation mix are shrinking, leading to concerns regarding grid stability. Furthermore, the scale of smaller distributed PE resources needed for managing the electrical network could dwarf the existing system leading to more complex optimization problems and communication interconnections. This paper introduces the concept of a hierarchal system of controllers that spans the grid edge or the customer end to distribution scale substations or solid-state power substation (SSPS). This concept focuses on minimizing the number of interfaces and optimization considerations in the grid by clustering resources into nodes and hubs. The work validates the concept in a controller hardware-in-the-loop (cHIL) platform.

Chinthavali, Madhu Sudhan↗