Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric power grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Emergency Diesel Generator Backup Power Systems for Military Bases

Backup power systems on military installations must provide reliable power during a grid outage. The risks of blackouts and loss of electric power are not new. Outages of just a few hours are well known, but longer duration outages are becoming more frequent. The U.S. Army, Navy, and Air Force now require backup power from one to two weeks. For multiday outages, the reliability of emergency diesel generators will have a significant impact on the installation’s backup power system’s ability to provide power for critical missions.

backup power↗

Electricity Costs and Carbon Implications for CO 2 -to-Fuels in Selected Locations in 2030

With the growing interest in converting carbon dioxide (CO 2 ) to fuels and products to reduce overall greenhouse gas emissions and extend carbon from biogenic and other sources, the development of carbon capture and utilization (CO2U) technologies and industry is crucial. The Markets, Resources, and Environmental and Energy Justice of CO 2 -to-Fuels Technologies (short title: MarkeRs & EEJ) project supports this goal by assessing the resource and market potential and infrastructure requirements for mid-term (-2030) and long-term (-2050) deployment of CO2U technologies. The overall project analyzes CO2U economic and resource requirements as well as sustainability and environmental and energy justice (EEJ) metrics. This report focuses on short-term (-2030) aspects of the project. It identifies three CO2U locations in the Midwestern United States and quantifies the costs for potential electricity resources and marginal emissions for each site in the near term (e.g., 2030). We focus on four electricity purchase options, including retail rate, physical power purchase agreement (PPA), financial PPA, and real-time pricing (RTP), for each of the three sites and consider potential policies such as production tax credits (PTCs). We also assess time-dependent hourly marginal electricity costs and the marginal emission rates using modeled scenarios from Cambium (Gagnon et al. 2021).The results of the analysis are expected to inform other projects within the U.S. Department of Energy's CO 2 -to-Fuels Consortium, especially the Economics and Sustainability of CO 2 Utilization Technologies with Techno-Economic Analysis and Life Cycle Analysis (TEA/LCA) project, led by Michael Wang of Argonne National Laboratory and Ling Tao of the National Renewable Energy Laboratory. The project results are also expected to inform the investment and technology communities and policymakers at the U.S. Department of Energy, state, and regional levels and guide investment by government and industry in research and development portfolios.

09 BIOMASS FUELS↗

Evaluating advanced nuclear fission technologies for future decarbonized power grids

Advanced nuclear fission, which encompasses various innovative nuclear reactor designs, could contribute to the decarbonization of the United States electricity sector. However, little is known about how cost-competitive these reactors would be compared to other technologies, or about which aspects of their designs offer the most value to a decarbonized power grid. We employ an electricity system optimization model and a case study of a decarbonized U.S. Eastern Interconnection circa 2050 to generate initial indicators of future economic value for advanced reactors and the sensitivity of future value to various design parameters, the availability of competing technologies, and the underlying policy environment. These results can inform long-term cost targets and guide near-term innovation priorities, investments, and reactor design decisions. We find that advanced reactors should cost $\$5.7$–$\$7.3$/W to gain an initial market share (assuming 30 year asset life and 3.5 %–6.5 % real weighted average cost of capital), while those that include thermal storage in their designs can cost up to $\$6.0$/W–$\$7.7$/W (not including cost of storage). Since the marginal value of advanced fission reactors declines as market penetration increases, break-even costs fall ~32 % at 100 GW of cumulative capacity and ~51 % at 300 GW. Additionally, policies that provide investment tax credits for nuclear energy create the most favorable environment for advanced nuclear fission. In conclusion, these findings can inform near-term resource allocation decisions by stakeholders, innovators and investors working in the energy technology sector.

Capacity expansion↗

Optimal design and integration of decentralized electrochemical energy storage with renewables and fossil plants

Increasing renewable energy requires improving the electricity grid flexibility. Existing measures include power plant cycling and grid-level energy storage, but they incur high operational and investment costs. Using a systems modeling and optimization framework, we study the integration of electrochemical energy storage with individual power plants at various renewable penetration levels. Furthermore, our techno-economic analysis includes both Li-ion and NaS batteries to encompass different technology maturity levels. A California case-study indicates localized integration to be cost-effective for greater grid flexibility. Li-ion batteries can mitigate the residual demand fluctuations of small to medium-sized plants, while NaS batteries would be best-suited for larger storage with higher renewable penetration. Overall, the battery-enabled renewable integration could reduce the unmet grid demand by 75%, the renewable curtailment by 58%, and the CO 2 emission intensity by 16% while including the life cycle emissions of the battery and the renewable farm. Our scenario-based analysis also indicates that rather than replacing all fossil power plants, it is more economical to combine batteries and renewables with individual fossil plants to achieve a clean energy grid.

25 ENERGY STORAGE↗

Impacts of Ternary-Pumped Storage Hydropower on U.S. Western Interconenction with Extremely High Renewable Penetrations

In recent years, ternary pumped storage hydropower (T-PSH), as one of the advanced PSH technologies, has attracted more attention from the industry. The interest is because of the capability of providing fast power support for the future electric grid with high penetration of renewable energy (RE). This paper focuses on studying the impact of T-PSH on frequency response of the U.S. Western Interconnection under different penetration levels of RE, which are from 20% to 80%. The detailed model of T-PSH is developed and implemented in the Western Interconnection grid model based on the GE Positive Sequence Load Flow (PSLF) platform, which can capture the unique dynamics of hydraulic short-circuit (HSC) mode and fast mode switching of T-PSH. To reveal the dynamic benefit from T-PSH, the frequency response of the Western Interconnection has been compared with and without T-PSH. In addition, a new solution is discussed that uses T-PSH to improve system stability issues caused by high RE penetration.

13 HYDRO ENERGY↗

PETSc DMNetwork: A Library for Scalable Network PDE-Based Multiphysics Simulations

We present DMNetwork, a high-level package included in the PETSc library for the simulation of multiphysics phenomena over large-scale networked systems. The library aims at applications that have networked structures such as those in electrical, gas, and water distribution systems. DMNetwork provides data and topology management, parallelization for multiphysics systems over a network, and hierarchical and composable solvers to exploit the problem structure. DMNetwork eases the simulation development cycle by providing the necessary infrastructure through simple abstractions to define and query the network components. This article presents the design of DMNetwork, illustrates its user interface, and demonstrates its ability to solve multiphysics systems, such as an electric circuit, a network of power grid and water subnetworks, and transient hydraulic systems over large networks with more than 2 billion variables on extreme-scale computers using up to 30,000 processors.

extreme-scale computing↗

Roundtable on Foundational Science for Carbon-Neutral Hydrogen Technologies (Technology Status Document)

This document summarizes the status of carbon-neutral hydrogen production, storage and transport, and utilization. The state of the art in the implementation, limitations, and challenges of these technologies are summarized. Sources of hydrogen are broadly categorized as hydrcoarbons or water and the processes used to convert these sources to hydrogen as catalytic, thermochemical, or electrochemical. Catalytic steam methane reforming of methane is the dominant process today. Other processes have smaller production volumes and the technology is less mature, but are being deployed at increasing rates, most notably water electrolyzers for hydrogen fueling stations. Efficient transport and storage of hydrogen is one of the major challenges facing a hydrogen-based energy economy. This arises in part from its low volumetric energy density necessitating very high pressures or cryogenic temperatures to store sufficient amounts for practical applications. High-pressure compressed hydrogen cylinders are the incumbent hydrogen storage technology for applications such as light-duty fuel cell electric vehicles, for example. The storage of hydrogen in materials or in chemicals is being pursued to address the issues associated with compression, such as parasitic energy loss and weight, size, and cost of storage containers. The complex nature of the chemical and physical processes involved in the uptake, storage, and release of hydrogen has slowed the discovery of suitable hydrogen storage materials. Both small and large-scale storage face the challenge of embrittlement of the storage media by hydrogen. There is a myriad of uses of hydrogen offering the promises of improving the efficiency of various applications and reducing or eliminating CO 2 emissions. These range from direct electrochemical conversion to electricity to power vehicles and grid-level stationary applications to combustion to production of chemicals and commodities. One of the most impactful applications in terms of reduction of CO 2 emissions is fuel cell passenger vehicles and heavy-duty vehicles such as class 8 trucks. The challenges facing widespread deployment of fuel cells, beyond the major hurdle of the lack of a hydrogen distribution infrastructure, are cost and durability, primarily related to the precious metal cathode catalyst and its durability. The other uses of hydrogen from conversion to hydrocarbons, polymer upcycling, and upgrading of bio-oils are at varying stages of maturity and also face fundamental challenges associated with catalytic processes and materials.

08 HYDROGEN↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

Satellite Power System (SPS). State and local regulations as applied to satellite power system microwave receiving antenna facilities

State and local regulation of power plant construction and operation of solar power satellite (SPS) receiving stations is presented. Each receiving antenna station occupies a land area 100-200 km square, receives microwave transmissions from the solar power satellite, and converts them into electricity for transmission to the power grid. The long lead time associated with the SPS and the changing status of state and local regulation dictated emphasis on: generic classification of the types of regulation, and identification of regulatory vectors which affect rectenna facilities.

Kotin, A. D.↗

Solar power satellite system definition study. Volume 1, phase 1: Executive summary

A systems definition study of the solar satellite system (SPS) is presented. The technical feasibility of solar power satellites based on forecasts of technical capability in the various applicable technologies is assessed. The performance, cost, operational characteristics, reliability, and the suitability of SPS's as power generators for typical commercial electricity grids are discussed. The uncertainties inherent in the system characteristics forecasts are assessed.

Source record↗

Results of a utility survey of the status of large wind turbine development

Wind energy conversion systems were surveyed from a utility viewpoint to establish the state of the art with regard to: (1) availability of the type of machines; (2) quality of power generation; (3) suitability for electrical grid; (4) reliability; and (5) economics. Of the 23 designs discussed, 7 have vertical axis wind turbines, 9 have upwind horizontal axis turbines, and 7 have downwind horizontal axis turbines.

Watts, A.↗

A 15 kWe (nominal) solar thermal-electric power conversion concept definition study: Steam Rankin reciprocator system

A conceptual design of a 3600 rpm reciprocation expander was developed for maximum thermal input power of 80 kW. The conceptual design covered two engine configurations; a single cylinder design for simple cycle operation and a two cylinder design for reheat cycle operation. The reheat expander contains a high pressure cylinder and a low pressure cylinder with steam being reheated to the initial inlet temperature after expansion in the high pressure cylinder. Power generation is accomplished with a three-phase induction motor coupled directly to the expander and connected electrically to the public utility power grid. The expander, generator, water pump and control system weigh 297 kg and are dish mounted. The steam condenser, water tank and accessory pumps are ground based. Maximum heat engine efficiency is 33 percent: maximum power conversion efficiency is 30 percent. Total cost is $3,307 or $138 per kW of maximum output power.

Wingenback, W.↗

Performance Testing of a Prototypic Annular Linear Induction Pump for Fission Surface Power

Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal (NaK) through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 25 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head <1 to 90 kPa (<0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. While the pump was powered, the fluid responded immediately to changes in the input power level, but when power was removed altogether, there was a brief slow-down period before the fluid would come to rest. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.

Polzin, K. A.↗

Performance of an Annular Linear Induction Pump with Applications to Space Nuclear Power Systems

Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 125 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head less than 1 to 90 kPa (less than 0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.

Polzin, Kurt A.↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Europe’s energy policy based on large-scale use of renewables most likely will require supplemental power supplies to balance their electrical power systems

Political decisions toward an increased role for renewable energy sources (wind & solar) in Europe will have an impact on the functioning of the electrical power systems that will have to be offset due to the inherent intermittent nature of renewable sources. The offset can be accomplished either through increasing non-renewable energy supply and production from other means, including purchasing Russian piped natural gas and LNG, or decreasing demand by curtailing power consumption. Europe likely will also need increased energy supplies to cover reduced gas production in the North Sea and Netherlands. Also, expected disconnection of Baltic states from the BRELL (Belarus-Russia-EstoniaLatvia-Lithuania) grid will force these countries to acquire electricity from Europe, resulting in increased demands on the European power grid that will require additional capacity to offset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗