Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Refractive index of lithium fluoride to 900 gigapascal and implications for dynamic equation of state measurements

Lithium fluoride (LiF) is a unique crystal possessing the largest reported bandgap of any material and is predicted to remain transparent to visible light under stresses in excess of 1000 GPa. Dynamic compression experiments often utilize LiF as a window material to maintain stress on a sample while enabling direct measurements of interface velocity. However, typical velocimetry diagnostics measure changes in the optical path length; therefore, an accurate understanding of LiF’s equation of state and refractive index is needed. Here, we present a measurement of the LiF refractive index up to 900 GPa from a low-temperature ramp-compression experiment at the National Ignition Facility. To demonstrate propagation of optical uncertainty from this work to equation of state measurements, simulations in which a tin–LiF interface reaches a peak stress of 825 GPa show that the principal isentrope of tin can be determined up to 1450 GPa with a 1.2% uncertainty in density while considering uncertainties in the optical response of LiF.

36 MATERIALS SCIENCE↗

Optimized x-ray sources for x-ray diffraction measurements at the Omega Laser Facility

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

47 OTHER INSTRUMENTATION↗

X-ray diffraction at the National Ignition Facility

We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2 θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2 θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2–7 on the periodic table.

47 OTHER INSTRUMENTATION↗

First-principles equations of state and structures of liquid metals in multi-megabar conditions

Liquid metals at extreme pressures and temperatures are widely interested in the high-pressure community. Based on density functional theory molecular dynamics, we conduct first-principles investigations on the equation of state ( EOS) and structures of four metals (Cu, Fe, Pb, and Sn) at 1.5–5 megabar conditions and 5 × 10 3 –4 × 10 4 K. Our first-principles EOS data enable evaluating the performance of four EOS models in predicting Hugoniot densities and temperatures of the four systems. We find the melting temperature of Cu is 1000–2000 K higher and shows a similar Clapeyron slope, in comparison to those of Fe. Our structure, coordination number, and diffusivity analysis indicates all the four liquid metals form similar simple close-packed structures. Our results set theoretical benchmarks for EOS development and structures of metals in their liquid states and under dynamic compression.

36 MATERIALS SCIENCE↗

High-precision shock equation of state measurements for metallic fluid carbon between 15 and 20 Mbar

Diamond is an efficient ablator material to convert the energy of high-power giant lasers into ablation pressure with applications for High-Energy-Density (HED) science, planetary science, and Inertial Confinement Fusion (ICF) research at the National Ignition Facility (NIF). Unfortunately, current theoretical equation of state models cannot reproduce all the observed experimental data in the multi-megabar regime particularly relevant for HED and ICF research. New experimental data on the behavior of carbon at extreme pressures and temperatures are, therefore, essential to improve our predictive capability to design and analyze dynamic compression experiments for HED or ICF research and build improved equation of state models in the future. In this paper, we report high-precision laser-driven shock compression measurements on diamond single crystals at the Omega Laser Facility. Using ultrafast Doppler optical Velocimetry Interferometer System for Any Reflector (VISAR) to track the leading shock front and a quartz plate as an in situ reference, we obtain relative pressure-density shock equation-of-state measurements between 15 and 20 Mbar with an impedance-matching procedure. We also report shock-and-release measurements in a spherical geometry at the NIF. The new data provide tight constraints on the compressibility of warm dense carbon along the Hugoniot of full density diamond, allowing us to discriminate between existing theoretical equation-of-state models. We find that both LLNL LEOS 9061 and LANL Sesame 7835 models capture well the shock compressibility in the explored range. LANL Sesame 7835 also reproduces well the observed shock-and-release behavior of diamond near 10–20 Mbar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

Comparing temperature convergence of shocked thin films of tin and iron to a bulk temperature source

An outstanding challenge in developing a complete equation of state for materials at elevated pressure and temperature is a robust method of determining the bulk temperature state under dynamic conditions. In metals, the determination of bulk temperature states by optical pyrometry is complicated by the small optical depth and thermal conduction effects. These effects lead to observed temperatures differing by 20% or more from the bulk temperature state. In this work, we show the presence of thermal conduction effects in temperature measurements of tin and iron coatings during dynamic compression experiments. We demonstrate that tin, in contrast to iron, coatings can fail to converge to a bulk temperature source over the time scale of the experiment, requiring the experimenter to modify assumptions, design, or analysis. This work bounds thermal transport at shocked conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long duration x-ray source development for x-ray diffraction at the National Ignition Facility

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

Werellapatha, K. (ORCID:0000000293154054)↗

Toward using collective x-ray Thomson scattering to study C–H demixing and hydrogen metallization in warm dense matter conditions

The insulator–metal transition in liquid hydrogen is an important phenomenon to understand the interiors of gas giants, such as Jupiter and Saturn, as well as the physical and chemical behavior of materials at high pressures and temperatures. Here, the path toward an experimental approach is detailed based on spectrally resolved x-ray scattering, tailored to observe and characterize hydrogen metallization in dynamically compressed hydrocarbons in the regime of carbon–hydrogen phase separation. With the help of time-dependent density functional theory calculations and scattering spectra from undriven carbon samples collected at the European x-ray Free-Electron Laser Facility (EuXFEL), we demonstrate sufficient data quality for observing C–H demixing and investigating the presence of liquid metallic hydrogen in future experiments using the reprated drive laser systems at EuXFEL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High precision control of laser energy for laser–matter interaction studies

Precise, highly reproducible control of the laser energy is required for high confidence laser–matter interaction research such as in dynamic compression science and high energy density physics. The energy must be adjustable without affecting the pulse shape (time varying intensity) or beam smoothness. We have developed a convenient two-stage energy tuning method for a nominal 100 J, 351 nm (UV) laser. The energy is adjusted in 10 J (10%) increments by operating the laser at full energy and inserting a beam splitter in the laser output. As the splitter is located after the final frequency tripling optics, the UV pulse shape is unchanged. The energy is varied by substituting a splitter of different reflectivity. For finer 3 J (3%) increments, the infrared pulse is attenuated inside the laser before the final amplifier. This requires modest tuning to preserve the pulse shape. The demonstrated variation in shot-to-shot reproducibility is less than +/–2.5 J (5% of the full energy), irrespective of the laser output energy. These approaches can be adapted to most ~100 J class lasers. We describe these techniques and show two examples where they have elucidated the underlying physics in laser shock compression experiments. One used only the beam splitters to establish the pressure for melting in iron. The other combined both techniques to finely increment the peak stress (~2 GPa steps) in germanium to precisely determine the onset and completion of melting—including the melting kinetics. Furthermore, these unambiguous results would not be possible without the developments described here.

47 OTHER INSTRUMENTATION↗

Time-resolved X-ray diffraction diagnostic development for the National Ignition Facility

Here we present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 10 11 , 10.25-keV photons/ns at the 400 μm diameter sample.

36 MATERIALS SCIENCE↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

X-ray diffraction strains in laser-ablated aluminum, nickel, sodium, and invar: Pressures to 475 GPa

Dynamically compressed materials in longitudinal waves are described by two physical models: hydrostatic pressure, with equal, normal, principal stresses or material uniaxially strained in the wave propagation direction. These models are disparate, so experimental comparisons and evaluations are important. Polycrystalline material in a state of hydrostatic pressure will have no eccentricity of x-ray-diffracted Debye–Scherrer rings. A general three-dimensional solution of Bragg diffracted x rays based on principal crystallographic strains in the compression wave was found. The distortion of x-ray diffraction beams has been used for strain measurements; the analysis developed incorporates a strained reciprocal lattice and the incident x-ray beam. Strain-distorted Polanyi surfaces form an annulus of compression with an ellipsoid of revolution in reciprocal space, which is intersected by Ewald's sphere for Bragg diffraction. The in situ measurements for strain describe nanosecond diffraction evaluated using two planes, (hkl) and (h′k′l′), both in the same crystallographic phase. Diffraction from Al, Ni, Na, and Invar quantifies the compression axial strains in these materials: The compression axial ratios are 0.65, 1.05, 0.88, and 1.58 at pressures of 291, 402, 409, and 367 GPa for the respective materials. Crystal structure transformations with homogeneous pressurized stresses, mandating equal normal strains, should not be anticipated to agree with heterogeneous, uniaxially strained, and sheared crystalline phases. Measurements support in-plane strains increasing with pressure, p , in fcc and hcp aluminum as ε 22 = −0.21 p /TPa.

Alloys↗

Enabling accurate chemical modeling of shocked energetic materials using a machine learning interatomic potential

Understanding the complex chemistry of organic materials under dynamic compression is important for many applications, but it is challenging due to the large number of reactions occurring at various time scales. Here, in this study, we develop a machine learning potential based on Chebyshev polynomials to study the insensitive energetic material 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) under detonation. We discuss a strategy for constructing diverse training data needed to capture the complex chemistry of TATB. Our potential demonstrates strong transferability across a wide range of thermodynamic conditions and other explosives, enabling accurate and reliable chemical modeling of organic materials under extreme conditions. The efficiency of our approach allows for simulations over several nanoseconds and for large system sizes, providing detailed insights into the chemistry of shocked TATB. The model accurately reproduces experimental Hugoniot equation of state data, and our simulations reveal the rapid formation of nitrogen-rich carbon clusters following shock. The methods and datasets developed here offer a robust framework for accurate chemical modeling of other shocked organic energetic materials.

Chemistry↗

Experimental shock Hugoniot and melt boundary temperatures of aluminum

Aluminum is a ubiquitous component in dynamic compression, pulsed power, and other high energy density physics studies. Its high-pressure behavior and phase diagram are extensively studied standards in shockwave physics. While theoretical calculations and multiphase equations of state have been benchmarked to velocity measurements of loading and unloading waves, pressure and density under shock, and other mechanical data, experimental temperature data under these conditions have not been reported. We conducted a series of experiments shocking and releasing aluminum 6061 and 1100 samples into lithium fluoride windows. We measured temperature at the sample–window interface under steady compression and subsequent isentropic release. These results allow us to constrain the temperature of the solid Hugoniot and the boundary between the liquid and face-centered cubic solid phases.

Hartsfield, Thomas Murray [Sandia National Laborat↗

Laser shock XAFS studies at OMEGA facility [HPR invited paper on XAFS]

State-of-the-art laser facilities offer an excellent opportunity for studying materials at Mbar-Gbar pressures by dynamical compression. In this paper, we summarize recent experiments on EXAFS measurements of compressed solid iron up to 5 Mbar using OMEGA laser facility. The X-ray source is produced by a spherical implosion, providing enough brightness and spectral smoothness required for EXAFS measurements. The compression path is tuned by laser pulse shaping to achieve off-hugoniot states. Lastly, with an anharmonic model, the density, temperature and upper limit of strength of the compressed iron are determined from EXAFS data. Prospects of XAFS study of other materials are also discussed.

36 MATERIALS SCIENCE↗