Biomass Gasification Technology Assessment: Consolidated Report

Harris Group Inc. (HGI) was commissioned by the National Renewable Energy Laboratory to assess gasification and tar reforming technologies. Specifically, the assessments focused on gasification and tar reforming technologies that are capable of producing a syngas suitable for further treatment and conversion to liquid fuels. HGI gathered sufficient information to analyze three gasification and tar reforming systems. This report summarizes the equipment, general arrangement of the equipment, operating characteristics, and operating severity for each technology. The order of magnitude capital cost estimates are supported by a basis-of-estimate write-up, which is also included in this report. The report also includes Microsoft Excel workbook models, which can be used to design and price the systems. The models can be used to analyze various operating capacities and pressures. Each model produces a material balance, equipment list, capital cost estimate, equipment drawings and preliminary general arrangement drawings. Example outputs of each model are included in the Appendices.

09 BIOMASS FUELS↗

Engineered Osmosis for Energy Efficient Separations: Optimizing Waste Heat Utilization

The purpose of this study is to design (i) a stripper system where heat is used to strip ammonia (NH 3 ) and carbon dioxide (CO 2 ) from a diluted draw solution; and (ii) a condensation or absorption system where the stripped NH 3 and CO 2 are captured in condensed water to form a re-concentrated draw solution. This study supports the Industrial Technologies Program of the DOE Office of Energy Efficiency and Renewable Energy and their Industrial Energy Efficiency Grand Challenge award solicitation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disposal Systems Evaluation Framework DSEF User Manual (V.3.0)

The Disposal Systems Evaluation Framework (DSEF) has been developed at Lawrence Livermore National Laboratory (LLNL) to formalize and facilitate the development and documentation of repository conceptual design options for a range of waste forms, geologic environments, repository design concepts, and repository operating modes. DSEF is one component of the Engineered Barrier System (EBS) family of work packages at several national laboratories led by Sandia National Laboratories (SNL), in support of the DOE Office of Nuclear Energy, specifically of the Used Fuel Disposition (UFD) Campaign within the Office of Used Nuclear Fuel Disposition Research and Development (NE-53). DSEF is a knowledge management system that allows the user to intelligently access and draw data from a case library of hundreds of completed thermal analyses (currently 721 cases in the library), and draw input from databases of material properties and repository development cost data (currently the data in these databases are drawn from more than 100 references). The core functionality of DSEF is provided by a Microsoft Office Excel 2010 workbook with macros and form controls that create a structured environment and walk the user through the steps of creating the input data required to perform disposal system evaluations internally and by interfacing with external programs. The user can choose to work with built-in data from the case library of previous analysis cases, from the material property databases, or can define their own input descriptions and data. DSEF uses the Excel worksheet protection (implemented on a sheet by sheet basis) to prevent inadvertent over-writing of formulas with data. When worksheet protection is enabled, the user can see all underlying formulas, and enter data in unprotected cells (the unprotected cells generally correspond to the yellow highlighted cells). Worksheet protection also prevents restructuring the files (adding or deleting rows or columns) and changing the formatting, as well as preventing access to the Visual Basic Editor to prevent modification of the macros. If the user needs to modify the worksheet structure, formulas, or macros, they can contact LLNL to get the password to unprotect the worksheets. However, care should be taken in making any modifications, since the macros and formulas are dependent in some cases on the current structure, range names, and macro subroutines DSEF is set up to retrieve the results of external thermal analysis program runs, summarize them graphically, and provide a template for adding the new results to the Case Library. The Case Library worksheet in DSEF is set up to create a Case Library data record for each new analysis case, at the top of the list of prior cases. Therefore, a separate DSEF file (with unique name) should be saved for each run that is to be archived. Users should submit a copy of their DSEF files to LLNL so that their results can be added to the overall Case Library and made available to other laboratories and stakeholders. LLNL will maintain the DSEF Case Library and make the most current files available on the SNL SharePoint site. The Revision History sheet documents the file evolution. One of the key objectives of DSEF is to allow the user to compare the results of thermal analyses to the thermal constraints of the design components. These comparisons can then be used to consider design, layout, and operating mode modifications to find combinations that can meet the thermal constraints for a given combination of waste form, geologic medium, surface storage time, and system concept of operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)

Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronic heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Electromagnetics Simulations of the Leakage Through the Pump-out Holes in the DISC Electromagnetic Interference Shield

In order to prevent electromagnetic interference (EMI) from affecting the DISC diagnostic, an EMI shield was added. Figure 1 is a cross section from a CAD model of DISC and shows the EMI shield in situ. The shield is orange and at the top of the figure. Figure 2 is a drawing of just the EMI shield. The slit in the center of the EMI shield is covered by a metal mesh, which is not shown in this drawing. The small holes toward the base of the conical portion of the EMI shield are the pump-out holes, and the electromagnetic leakage through these holes is the subject of this report1. An alternate design for the EMI shield is considered in order to determine how to increase the EMI effectiveness of the pump-out holes in the shield without compromising the flow rate through the shield. Both the original and alternate designs are simulated and compared.

42 ENGINEERING↗

Capillary Break Beneath a Slab: Polyethylene Sheeting over Aggregate; Southwestern Pennsylvania (Fact Sheet)

This document provides content for three areas of the Building America Solution Center. First, "Insulating Closed Crawlspace Walls and Band Joist Area" describes how to install rigid foam insulation on the interior perimeter walls and band joist area in closed crawlspace foundations of homes. Second, "Removing Construction Debris from Flexible Ducts" describes how to clean flexible ducts after construction or major renovation of a home to remove debris resulting from building materials, particularly airborne dust and particulates. Third, images, CAD drawings, and a case study illustrate right and wrong ways to apply polyethylene sheeting over aggregate. Similarly, a CAD drawing is included that illustrates the use of a concrete slab over polyethylene.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps

Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15 minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.

life-cycle cost simulations↗

SLAC Disk Loaded Waveguide (DLWG) Accelerator Structure

This drawing package is for the SLAC s-band DLWG accelerator structures used in the original linac. These structures are still operating to this day serving in the SLAC LCLS-I and FACET linacs. For access to the drawings, contact the SLAC Office of Research Partnerships & Technology Commercialization (IPRP@slac.stanford.edu).

Tremaine, Aaron↗

Greenbuilt Retrofit Test House (Final Report)

The Greenbuilt house is a 1980's era house in the Sacramento area that was a prominent part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration Program. The house underwent an extensive remodel, aimed at improving overall energy efficiency with a goal of reducing the home's energy use by 50%. NREL researchers performed a number of tests on the major systems touched by the retrofit to ensure they were working as planned. Additionally, SMUD rented the house from Greenbuilt Construction for a year to allow NREL to perform a number of tests on the cooling system and the water heating system. The goal of the space conditioning tests was to find the best ways to cut cooling loads and shift the summer peak. The water heating system, comprised of an add-on heat pump water heater and an integrated collector-storage solar water heater, was operated with a number of different draw profiles to see how varying hot water draw volume and schedule affected the performance of the system as a whole. All the experiments were performed with the house empty, with a simulated occupancy schedule running in the house to mimic the load imposed by real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Report 21.3: Cost Effectiveness of Linear (T8) LED Lamps

Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($\$$40, $\$$80, or $\$$120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15 minutes or 30 minutes), and melded electricity rate ($\$$0.06/kWh, $\$$0.12/kWh, $\$$0.18/kWh, or $\$$0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline Assessment of TREAT for Modeling and Analysis Needs

TREAT is an air-cooled, graphite moderated, thermal, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions simulating various types of nuclear excursions and transient undercooling situations that could occur in a nuclear reactor. After 21 years in a standby mode, TREAT is being re-activated to revive transient testing capabilities. Given the time elapsed and the concurrent loss of operating experience, current generation and advanced computational methods are being applied to begin TREAT modeling and simulation prior to renewed at-power operations. Such methods have limited value in predicting the behavior of TREAT without proper validation. Hence, the U.S. DOE has developed a number of programs to support development of benchmarks for both critical and transient operations. Extensive effort has been expended at INL to collect detailed descriptions, drawings and specifications for all aspects of TREAT, and to resolve conflicting data found through this process. This report provides a collection of these data, with updated figures that are significantly more readable than historic drawings and illustrations, compositions, and dimensions based on the best available sources. This document is not nor should it be considered to be a benchmark report. Rather, it is intended to provide one-stop shopping, to the extent possible, for other work that seeks to prepare detailed, accurate models of the core and its components. Given the nature of the variety of historic documents available and the loss of institutional memory, the only completely accurate database of TREAT data is TREAT itself. Unfortunately, disassembly of TREAT for inspection, assay, and measurement is highly unlikely. Hence the data provided herein is intended serve as a best-estimate substitute.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrating Renewable Generation into Grid Operations: Four International Experiences

International experiences with power sector restructuring and the resultant impacts on bulk power grid operations and planning may provide insight into policy questions for the evolving United States power grid as resource mixes are changing in response to fuel prices, an aging generation fleet and to meet climate goals. Australia, Germany, Japan and the UK were selected to represent a range in the level and attributes of electricity industry liberalization in order to draw comparisons across a variety of regions in the United States such as California, ERCOT, the Southwest Power Pool and the Southeast Reliability Region. The study draws conclusions through a literature review of the four case study countries with regards to the changing resource mix and the electricity industry sector structure and their impact on grid operations and planning. This paper derives lessons learned and synthesizes implications for the United States based on answers to the above questions and the challenges faced by the four selected countries. Each country was examined to determine the challenges to their bulk power sector based on their changing resource mix, market structure, policies driving the changing resource mix, and policies driving restructuring. Each countries’ approach to solving those changes was examined, as well as how each country’s market structure either exacerbated or mitigated the approaches to solving the challenges to their bulk power grid operations and planning. All countries’ policies encourage renewable energy generation. One significant finding included the low- to zero-marginal cost of intermittent renewables and its potential negative impact on long-term resource adequacy. No dominant solution has emerged although a capacity market was introduced in the UK and is being contemplated in Japan. Germany has proposed the Energy Market 2.0 to encourage flexible generation investment. The grid operator in Australia proposed several approaches to maintaining synchronous generation. Interconnections to other regions provides added opportunities for balancing that would not be available otherwise, and at this point, has allowed for integration of renewables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Life Cycle Cost Analysis Framework for Geologic Storage of Hydrogen

Large scale geostorage options for fuels including natural gas and petroleum offer substantial buffer capacity to meet or hedge against supply disruptions. This same notion may be applied to large scale hydrogen storage to meet industrial or transportation sector needs. This study develops an assessment tool to calculate the potential ‘gate-to-gate’ life cycle costs for large scale hydrogen geostorage options in salt caverns, and continues to develop modules for depleted oil/gas reservoirs and aquifers. The U.S. Department of Energy has an interest in these types of storage to assess the geological, geomechanical and economic viability for this type of hydrogen storage. Understanding, and looking to quantify, the value of large-scale storage in a larger hydrogen supply and demand infrastructure may prove extremely beneficial for larger infrastructure modeling efforts when looking to identify the most efficient means to fuel a hydrogen demand (e.g., industrial or transportation-centric demand). Drawing from the knowledge gained in the underground large scale storage options for natural gas and petroleum in the U.S., the potential to store relatively large volumes of CO 2 in geological formations, the hydrogen storage assessment modeling will continue to build on these strengths while maintaining modeling transparency such that other modeling efforts may draw from this project.

08 HYDROGEN↗

A Life Cycle Cost Analysis Framework for Geologic Storage of Hydrogen

Large scale geostorage options for fuels including natural gas and petroleum offer substantial buffer capacity to meet or hedge against supply disruptions. This same notion may be applied to large scale hydrogen storage to meet industrial or transportation sector needs. This study develops an assessment tool to calculate the potential ‘gate-to-gate’ life cycle costs for large scale hydrogen geostorage options in salt caverns, and continues to develop modules for depleted oil/gas reservoirs and aquifers. The U.S. Department of Energy has an interest in these types of storage to assess the geological, geomechanical and economic viability for this type of hydrogen storage. Understanding, and looking to quantify, the value of large-scale storage in a larger hydrogen supply and demand infrastructure may prove extremely beneficial for larger infrastructure modeling efforts when looking to identify the most efficient means to fuel a hydrogen demand (e.g., industrial or transportation-centric demand). Drawing from the knowledge gained in the underground large scale storage options for natural gas and petroleum in the U.S., the potential to store relatively large volumes of CO 2 in geological formations, the hydrogen storage assessment modeling will continue to build on these strengths while maintaining modeling transparency such that other modeling efforts may draw from this project.

08 HYDROGEN↗

Best Practices for NPT Transit Matching

Transit matching is the process for relating or matching reports of shipments and receipts submitted to the International Atomic Energy Agency (IAEA). Transit matching is a component used by the IAEA in drawing safeguards conclusions and performing investigative analysis. Transit matching is part of IAEA safeguards activities and the State evaluation process, and it is included in the annual Safeguards Implementation Report (SIR). Annually, the IAEA currently receives reports of ~900,000 nuclear material transactions, of which ~500,000 are for domestic and foreign transfers. Of these the IAEA software can automatically match (i.e., machine match) about 95% of the domestic transfers and 25% of the foreign transfers. Given the increasing demands upon IAEA resources, it is highly desirable for the machine-matching process to match as many transfers as possible. Researchers at Oak Ridge National Laboratory (ORNL) have conducted an investigation funded by the National Nuclear Security Administration through the Next Generation Safeguards Initiative to identify opportunities to strengthen IAEA transit matching. Successful matching, and more specifically machine matching, is contingent on quality data from the reporting States. In February 2016, ORNL hosted representatives from three States, the IAEA, and Euratom to share results from past studies and to discuss the processes, policies, and procedures associated with State reporting for transit matching. Drawing on each entity's experience and knowledge, ORNL developed a best practices document to be shared with the international safeguards community to strengthen transit matching. This paper shares the recommendations that resulted from this strategic meeting and the next steps being taken to strengthen transit matching.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Hyperspectral Sensors Final Report CRADA No. TC02173.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Science Applications International Corporation (SAIC), National Security Space Operations/SRBU, to develop long-wave infrared (LWIR) hyperspectral imaging (HSI) sensors for airborne and potentially ground and space, platforms. The overarching purpose of the CRADA project was to facilitate the transfer of the necessary technology from LLNL to SAIC thereby allowing the U.S. Government to procure LWIR HSI sensors from this company. The purpose of the initial activities involving BIG GREEN sensors was to meet the customer’s delivery schedule for all of the BIG GREEN sensors. BIG GREEN is a complex and sophisticated instrument, and the requisite technology must be imparted to SAIC to allow them to successfully produce the instrument. It was expected that in the first few months of joint work, sensor models (performance, structural, thermal and optical) would be provided to SAIC. Additionally, existing drawings, assembly procedures, test procedures, test equipment definitions, software descriptions and code, and complete Bills of Material (BOM) would be provided. SAIC would analyze the models, purchase material per the BOM, create its own set of production drawings, models and procedures, and identify areas of concern or where further information transfer is required.

47 OTHER INSTRUMENTATION↗

Controlled Environmental Agriculture and Energy Project

Task A: Heating Plant - To design/build a Heating Plant Building with associated heating components for heating the greenhouse and to house the biomass gasification system. The subtasks for this task was and Engineering Design, Procurement and Construction activities. Overall milestones for this task were one construction permit, a code review and stamped drawings, engineered building vendor supplied sealed drawings, and the actual erection of a 1250 sq.ft. building. Task B: Heating System - The activities for this task included the procurement of the heating boilers and all ancillary components. This also included the installation of all heating system components in the new building plus the existing greenhouse structure. The milestone for this task was for the ability to heat 2500 gallons of water to 80 degrees F. Task C: Organic Matter Automated Hopper - The activities involved in this task involved design/fabrication of an automated hopper to feed the biomass gasification system. We need to procure materials and the automated motion components, have the system installed and factory acceptance test of the system. The milestone is to be able to feed wood chips at a rate of 20 Kg/Hr. Task D: Imbert Gasification System - The activities involved in this include the design/build of the gasifier with all accompany ductwork, cyclones and feeding system. Also there is a modification to the scrubber assembly with an automated ash removal system. Lastly a modification to the exhaust/flair system is made to capture heat from this component. Milestone for this task was to be able to produce 15 CFM of SynGas. Task E: Generator Powered by SynGas - Procure two 20kW 4 pole generator heads for installation on the gasifier system. Modification of the fuel plenum manifold with adjustment to the fuel curves for maximum power and load points. Milestone for this task is the ability to run two fuels, either SynGas or propane. This continues with the following tasks: Controls Heating System; Controls Generators 20kW; Controls Gasification; Algae System; and Final Evaluation/Operation.

60 APPLIED LIFE SCIENCES↗

Proposed Methodology for Design of Carbon Fiber Reinforced Polymer Spike Anchors into Reinforced Concrete

The included methodology, calculations, and drawings support design of Carbon Fiber Reinforced Polymer (CFRP) spike anchors for securing U-wrap CFRP onto reinforced concrete Tbeams. This content pertains to an installation in one of Los Alamos National Laboratory’s facilities. The anchors are part of a seismic rehabilitation to the subject facility. The information contained here is for information purposes only. The reader is encouraged to verify all equations, details, and methodology prior to usage in future projects. However, development of the content contained here complied with Los Alamos National Laboratory’s NQA-1 quality assurance program for nuclear structures. Furthermore, the formulations and details came from the referenced published literature. This literature represents the current state of the art for FRP anchor design. Construction personnel tested the subject anchor design to the required demand level demonstrated in the calculation. The testing demonstrated the ability of the anchors noted to carry loads in excess of 15 kips in direct tension. The anchors were not tested to failure in part because of the hazards associated with testing large-capacity tensile systems to failure. The calculation, methodology, and drawing originator was Eric MacFarlane of Los Alamos National Laboratory’s (LANL) Office of Seismic Hazards and Risk Mitigation (OSHRM). The checker for all components was Mike Salmon of the LANL OSHRM. The independent reviewers of all components were Insung Kim and Loring Wyllie of Degenkolb Engineers. Note that Insung Kim contributed to the initial formulations in the calculations that pertained directly to his Doctoral research.