Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Review of Sandia Energy Storage Research Capabilities and Opportunities (2020 to 2030)

Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Representing Carbon Dioxide Transport and Storage Network Investments within Power System Planning Models

Carbon dioxide (CO 2 ) capture and storage (CCS) is frequently identified as a potential component to achieving a decarbonized power system at least cost; however, power system models frequently lack detailed representation of CO 2 transportation, injection, and storage (CTS) infrastructure. In this paper, we present a novel approach to explicitly represent CO 2 storage potential and CTS infrastructure costs and constraints within a continental-scale power system capacity expansion model. In addition, we evaluate the sensitivity of the results to assumptions about the future costs and performance of CTS components and carbon capture technologies. We find that the quantity of CO 2 captured within the power sector is relatively insensitive to the range of CTS costs explored, suggesting that the cost of CO 2 capture retrofits is a more important driver of CCS implementation than the costs of transportation and storage. Finally, we demonstrate that storage and injection costs account for the predominant share of total costs associated with CTS investment and operation, suggesting that pipeline infrastructure costs have limited influence on the competitiveness of CCS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Hardware-In-the-Loop Hydropower and Ultracapacitor Hybrid Testbed

Widespread deployment of a proof-of-concept technological solution for power system performance improvement can be accelerated through onsite demonstration and pilot projects. Digital real-time simulation with power hardware-in-the-loop in controlled lab environment is the precursor to de-risk the timely and efficient execution of field demonstration and pilot projects. However, the detailed process of development, characterization, and calibration of such high fidelity simulation testbed needs to be documented in a reproducible and publicly accessible manner to leverage across broader research and development communities. This paper presents such a laboratory testbed to study black start capability of a run-of-river hydro + ultracapacitor hybrid system. Beside the high-fidelity model of the islanded grid with hydropower unit, the testbed includes the energy storage, grid following inverter, and grid emulator hardware. Several aspects such as storage characterization, control and various parameter settings necessary to capture frequency transients during load restoration are described in a comprehensive manner, which led to an effective and timely execution of black start field demonstration with an actual hydropower plant.

13 HYDRO ENERGY↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Non-Invasive Approach for Elucidating the Spatial Distribution of In Situ Stress in Deep Subsurface Geologic Formations Considered for CO 2 Storage (Task 2 Report Extracting Stress Data from Seismic Data)

This report describes research accomplishments achieved with funding provided through Department of Energy (DOE) Contract DE-FE0031686. The purpose of this DOE funding is to develop methods that can provide key information about stress fields that act on deep rocks without invading the earth to acquire that information. The research objective was to demonstrate methods that extract the azimuth directions of SHmax and SHmin stress in deep rocks from traditional seismic reflection data like the data that are used to explore for deep oil and gas reservoirs. Battelle performed two seismic investigations and achieved estimates of SHmax and SHmin azimuths in both efforts that agreed with local, non-seismic, ground-truth measurements of SHmax orientation. The first procedure utilized vertical seismic profiling (VSP) data; the second effort utilized three-dimensional (3D) seismic data.

58 GEOSCIENCES↗

Wind and Solar Hybrid Power Plants for Energy Resilience

Wind-solar-storage hybrid power plants represent a significant and growing share of new proposed projects in the United States (U.S.). Their uptake is supported by increasing renewable energy market share, technical abilities for dispatch and control, and decreasing wind, solar, and battery storage costs. Simultaneously, generation and storage resources are increasingly used in distributed power systems. While concerns around the reliability of the aging, transforming U.S. electric grid are growing, diversifying energy resources through hybridization or spatial distribution provides an opportunity to enhance power system resilience compared to single-source generation. Understanding where to build hybrids for resilience value, rather than bulk power supply, has not been fully explored in previous studies. Therefore, in this study, we complete a national complementarity analysis to identify areas in the U.S. that are particularly suited for wind-solar hybrid power plant development. We show the importance of seasonal and diurnal patterns in assessing complementarity, and identify that regions in the Great Plains, Midwest, and Southeast are particularly suited for hybrid power plants. We demonstrate the resilience value of hybridization for a reference system based near Memphis, Tennessee, and show optimal sizing of wind, solar, and storage assets given 1.0 and 0.9 critical load factors. Results indicate that pairing wind and solar assets better meet constant load demand and reduce storage requirements compared to solar alone. These results enable future work integrating complementarity metrics in resilience frameworks and indicate a need for more finer resolution of local resource, demand, and hazard data.

14 SOLAR ENERGY↗

COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. Furthermore, the approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

60 APPLIED LIFE SCIENCES↗

A Learning-based Supervisory Control Architecture for Electric Vehicle Charging System Paired with Energy Storages

A Machine Learning-based predictive model is developed for optimal dispatching energy storage system integrated with Electric Vehicle battery charger. The model is effectively trained using transfer learning algorithm and successfully validated via measurement data to achieve high fidelity and accuracy. The study findings provide possibilities for future development of the presented approach to implement computational heavy predictive algorithms with multi-step predictions in emerging modular bidirectional charger topologies to realize vehicle-to-grid (V2G) technology. The online tuning can be explored using the new measurements obtained during the operation, henceforth, enhancing the controller performance for integrating multiple DERs into distribution power networks that shows huge interest for the utilities and regulatory agencies. Multiple operation scenatios have been evaluated and simulation results are discussed to verify intended performance of the proposed control solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-scale Energy Storage Hazard Analysis & Design Objectives for System Safety

Battery based energy storage systems are becoming a critical part of a modernized, resilient power system. However, batteries have a unique combination of hazards that can make design and engineering of battery systems difficult. This report presents a systematic hazard analysis of a hypothetical, grid scale lithium-ion battery powerplant to produce sociotechnical "design objectives" for system safety. We applied system's theoretic process analysis (STPA) for the hazard analysis which is broken into four steps: purpose definition, modeling the safety control structure, identifying unsafe control actions, and identifying loss scenarios. The purpose of the analysis was defined as to prevent event outcomes that can result in loss of battery assets due to fires and explosions, loss of health or life due to battery fires and explosions, and loss of energy storage services due to non- operational battery assets. The STPA analysis resulted in identification of six loss scenarios, and their constituent unsafe control actions, which were used to define a series of design objectives that can be applied to reduce the likelihood and severity of thermal events in battery systems. These design objectives, in all or any subset, can be utilized by utilities and other industry stakeholders as "design requirements" in their storage request for proposals (RFPs) and for evaluation of proposals. Further, these design objectives can help to protect firefighters and bring a system back to full functionality after a thermal event. We also comment on the hazards of flow battery technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Long-Duration Energy Storage: Resiliency for Military Installations

This report provides a quantitative techno-economic analysis of a long-duration energy storage (LDES) technology, when coupled to on-base solar photovoltaics (PV), to meet the U.S. Department of Defense's (DoD's) 14-day requirement to sustain critical electric loads during a power outage and significantly reduce an installation's carbon footprint. The LDES modeled is Antora Energy's battery energy storage system (BESS). It is currently at a technology readiness level (TRL) of 7 and not ready for full-scale deployment. To support decisions on the value of near-term demonstrations, this analysis looked at the potential value of Antora Energy's BESS if deployed in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bi-Level Adaptive Storage Expansion Strategy for Microgrids Using Deep Reinforcement Learning

Battery energy storage (BES) is a versatile resource for the secure and economic operation of microgrids (MGs). Prevailing stochastic optimization-based approaches for BES expansion planning for MGs are computationally complicated. This work proposes a data-driven bi-level multi-period BES expansion planning framework to determine the siting, sizing, and timing of BES installations. The proposed planning framework unifies deep reinforcement learning (DRL) and linear programming, thereby decoupling the determinations for the integer and continuous decision variables in two time scales, respectively. In the upper level, a rainbow DRL agent with quantile regression is trained to provide dynamic planning policies to accommodate stochastic renewable energy resources (RESs), load, and battery price changes efficiently. Further, the lower level computes the optimal operation of MGs with frequency constraints to hedge the islanding contingency. The two levels communicate with one another by exchanging storage configuration and operating expenses in order to accomplish the shared goal of minimizing investment and operation costs. Comparative case studies on an MG are carried out to demonstrate the superiority of the proposed DRL-based solution to the mixed-integer linear programming counterpart on efficiency, scalability, and adaptability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-criteria CCUS Screening Evaluation of the Gulf of Mexico, USA - Supplementary Data

The Wendt et al. study aims to incorporate multiple and disparate carbon capture, utilization, and storage (CCUS) decision-making criteria into a systematic, quantitative analytical approach to help identify areas with potentially high suitability to serve as offshore CO2 storage or EOR regions. Spatially-distributed data from publicly-available sources within the Gulf of Mexico (GOM) study area (limited to federal waters; state waters were not evaluated) was compiled using the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) Cumulative Spatial Impact Layers™ (CSIL) tool to easily aggregate data based on evenly-distributed grids across the study region set at a resolution of approximately 25 square miles (65 square kilometers). The data included in this Microsoft Excel™ workbook provide the aggregated scores for each grid point across the study domain as well the weighting for each criterion under the four scenarios evaluated.

CCUS↗

Financing Storage as a Transmission Asset: Initial Considerations for an Emerging Use Case

Deploying energy storage as an electric transmission system asset is a unique use case that, despite a body of policy and regulatory support, has received little attention or investment in the United States. The benefits of using storage on the transmission system—and the remaining barriers to that use—have been explored elsewhere. This paper complements that body of research by exploring the finance implications of using energy storage as a transmission asset (SATA). Because transmission infrastructure in the U.S. is generally subject to rate-of-return regulation, in which asset owners receive both a return of their invested capital and a return on that capital, storage assets deployed for that use are not subject to market volatility and have a much lower risk profile overall. That lower risk profile would, in theory, correspond to lower interest rates and other more favorable financing terms relative to a storage project deployed in a market setting. This paper draws from corollaries in other markets to estimate the expected finance impacts of SATA projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

Regulators’ Financial Toolbox: Behind-the-Meter (BTM) Energy Storage Summary

On October 10, 2023, NARUC’s Center for Partnerships & Innovation (CPI) hosted a Regulators’ Financial Toolbox Webinar on the topic of Behind-the-Meter (BTM) Energy Storage. The webinar featured opening remarks by the Honorable Katherine Peretick, Commissioner, Michigan Public Service Commission; and presentations by Ryan Chan, Principal Strategic Analyst, Pacific Gas and Electric Company (PG&E); Arushi Sharma Frank, Energy Market Design Lead and Senior Counsel for Energy Regulatory Matters and Greg Thurnher, Technical Program Manager, Tesla; and Mark LeBel, Senior Associate, Regulatory Assistance Project (RAP).

24 POWER TRANSMISSION AND DISTRIBUTION↗