Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Persistence of crystal orientations across sub-micron-scale "super-grains" in self-organized Cu-W nanocomposites

We use precession electron diffraction to investigate the crystallographic character of copper (Cu)-tungsten (W) nanocomposites fabricated via physical vapor co-deposition at 400 oC. We observe sub-micron-scale regions, where apparently disconnected Cu and W grains have near identical crystallographic orientations. This persistence of grain orientations suggests Cu and W grains within these regions are interconnected in 3-D when they first form and may be considered as intercalated, sub-micron-scale "super-grains". Indeed, atom probe tomography provides direct evidence of 3-D interconnectivity of W domains. Our findings shed light on the structure and self organization mechanisms of nanocomposites formed by spontaneous phase separation of co-deposited metals.

Yadav, Digvijay↗

Plan for Post-Irradiation Examination of Zion Reactor Pressure Vessel Beltline Materials

The reactor pressure vessel (RPV) is a potentially life-limiting component in light-water reactors (LWR) because replacement of the RPV is not considered a viable option. Researchers studying the effects of radiation on RPV materials have long been interested in evaluating service-irradiated materials to assess currently available models for predicting radiation embrittlement of RPV steels. The decommissioning of the Zion Unit 1 NPP in Zion, Illinois presents a unique opportunity for characterization of an actual reactor pressure vessel (RPV) material after inservice degradation. The main interests in this case are the belt-line weld and base metals. Through-RPV wall thickness attenuation and chemical composition distributions are the obvious objectives of this characterization program. However, it also provides an opportunity to examine the inservice degradation and its comparison with currently available models for prediction of radiation embrittlement of RPV steels. All of these efforts will provide a better understanding of materials degradation and other issues associated with extending the lifetime of existing NPPs beyond 60 years of service. The primary foci are the Linde 80 flux, wire heat 72105 (WF-70) circumferential belt-line weld and the A533B-1 base metal from the intermediate shell harvested from a region of peak fluence (0.7 x 10{sup 19} n/cm{sup 2}, E > 1.0 MeV) on the internal surface of the Zion Unit 1 vessel. Following determination of the through-thickness chemical composition, Charpy impact, fracture toughness, tensile, and hardness testing will be being performed to characterize the through-thickness mechanical properties of the base metal and belt-line-weld materials. In addition to mechanical properties, microstructural characterizations will be performed using various techniques, including Atom Probe Tomography, Small Angle Neutron Scattering, and Positron Annihilation Spectroscopy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spatial resolution of synchrotron x-ray microtomography in high energy range: Effect of x-ray energy and sample-to-detector distance

Spatial resolution of three-dimensional images obtained by synchrotron X-ray microtomography technique is evaluated using cyclic bar patterns machined on a steel wire. Influences of X-ray energy and the sample-to-detector distance on spatial resolution were investigated. High X-ray energies of 33-78 keV are applied due to the high X-ray absorption of transition metals. Best spatial resolution of about 1.2 {mu}m pitch was observed at the sample-to-detector distance range of 20-110 mm and at the energy range of 68-78 keV. Several factors such as X-ray scattering and diffraction phenomena affecting the degradation of spatial resolution are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the efficacy of post-build thermomechanical treatments to improve properties of Zirconium fabricated using ultrasonic additive manufacturing

Here, hot-isostatic pressing has been applied to Zirconium plate fabricated using the ultrasonic additive manufacturing (UAM) technique to enhance interfacial bond quality. Specimens heated to 800 C for 1 h at 100 MPa pressure showed grain growth across many prior foil-to-foil interfaces, thereby increasing foil adhesion. In addition to the material softening induced by a loss of Hall-Petch strengthening, premature failure of specimens loaded parallel to the build direction was observed. Premature specimen failure was attributed to the local delamination at prior foil-to-foil boundaries where grain growth was pinned by Ti impurities introduced during the UAM process via the interaction between a Ti-alloy buffer foil and the welded Zr-foils underneath. In addition, the presence of Ti along select foil interfaces resulted in the nucleation and growth of secondary (Zr,Ti)(Fe,Cr) laves phases during higher-temperature thermomechanical processing. Using a combination of micro-scale X-ray computed tomography, fractography, and in-situ digital image correlation, the effect of defects along prior foil-to-foil boundaries was revealed as delamination-assisted plasticity accelerated specimen failure in preferred tensile orientations. These findings underscore the importance of impurity control when optimizing weld quality of higher-strength material systems using ultrasonic welding.

36 MATERIALS SCIENCE↗

Catalytic Adventures in Space and Time Using High Energy X-rays

Very high energy X-rays have long offered great promise in providing great insight into the inner workings of catalysts; insights that may complement the array of techniques available to researchers in catalysis either in the laboratory or at more conventional X-ray wavelengths. This contribution aims to critically assess the diverse possibilities now available in the high energy domain as a result of the maturation of third generation synchrotron facilities and to look forward to the potential that forthcoming developments in synchrotron source technology may offer the world of catalysis in the near future.

36 MATERIALS SCIENCE↗

Effect of synthesis temperature on the phase formation of NiTiAlFeCr compositionally complex alloy thin films

Here, the synthesis temperature dependent phase formation of Ni 10 Ti 10 Al 25 Fe 35 Cr 20 thin films is compared to a bulk processed sample of identical composition. The as-cast alloy exhibits a dual-phase microstructure which is composed of a disordered BCC phase and AlNiTi-based B2- and/or L2 1 -ordered phase(s). Formation of the BCC phase as well as an ordered AlNi-based B2 phase is observed for a thin film synthesised at 500 °C (ratio of synthesis temperature of thin film to melting temperature of bulk alloy: T/T m = 0.49), which is attributed to both surface and bulk diffusion mediated growth. Post deposition annealing at 900 °C (T/T m = 0.75) of a thin film deposited without intentional heating results in the formation of NiAlTi-based B2 and/or L2 1 -phase(s) similar to the bulk sample, which is attributed to bulk diffusion. Depositions conducted at room temperature without intentional substrate heating (T/T m = 0.20) resulted in the formation of an X-ray amorphous phase, while a substrate temperature increase to 175 °C (T/T m = 0.28) causes the formation of a BCC phase. Atom probe tomography of the thin films deposited without intentional substrate heating and at 175 °C indicates the formation of ~5 nm and ~10 nm FeAl-rich domains, respectively. This can be rationalized based on the activation energy for surface diffusion, as Ti and Ni exhibt 2.5 to 4 times larger activation energy barriers than Al, Fe and Cr. It is evident from the homologous temperature that the phase formation observed at 500 °C (T/T m = 0.49) is a result of both surface and bulk diffusion. As the temperature is reduced, the formation of FeAl-rich domains can be understood based on the differences in activation energy for surface diffusion and is consistent with kinetically limited thin film growth.

36 MATERIALS SCIENCE↗

X-ray phase laminography with a grating interferometer using iterative reconstruction

X-ray phase computed laminography is performed using a Talbot interferometer and synchrotron radiation. An iterative reconstruction algorithm which includes prior information about limited support, range of values and sparsity of the imaged object has been developped. It allows the reconstruction of objects with an improved resolution of the unsampled frequencies, compared to the classical filtered backprojection. The imaging method, demonstrated for a nylon mesh sample and a leaf sample, shows promising results for the imaging of flat, laterally extended objects made of low absorbing elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron and X-Ray Diffraction Studies of Advanced Materials

The selection of articles in the special topic 'Neutron and X-Ray Studies of Advanced Materials' is based on the materials presented during the TMS 2009 annual meeting in San Francisco, CA, February 15-19, 2009. The development of ultrabrilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultrasensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation, and strain. X-ray microdiffraction is nondestructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Moreover, the high-energy X-ray diffraction technique provides an effective tool for characterizing the mechanical and functional behavior in various environments (temperature, stress, and magnetic field). At the same time, some neutron diffraction instruments constructed mainly for the purpose of engineering applications can be found at nearly all neutron facilities. The first generation-dedicated instruments designed for studying in-situ mechanical behavior have been commissioned and used, and industrial standards for reliable and repeatable measurements have been developed. Furthermore, higher penetration of neutron beams into most engineering materials provides direct measurements on the distribution of various stresses (i.e., types I, II, and III) beneath the surface up to several millimeters, even tens of millimeters for important industrial components. With X-ray and neutron measurements, it is possible to characterize material behavior at different length scales. It is predicted that the application of these techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future, which will contribute to the development of materials technology and industrial innovation. Specifically, the use of these techniques provides bulk material properties that further augment new characterization tools including the increased use of atom probe tomography and high-resolution transmission electron microscopy systems. The combination of these techniques greatly assists the material property models that address multi-length-scale mechanisms. Different applications of diffuse scattering for understanding the fundamental materials properties are illustrated in the articles of Welberry et al., Goossens and Welberry, Campbell, Abe et al., Gilles et al., and Zhang et al. Analysis of thin films and two-dimensional structures is described in the articles of Gramlich et al., Brock et al., Vigliante et al., Kuzel et al., and Davydok et al. Recent advances in the line profile analysis are represented by the the articles of Scardi et al., Ungar et al., and Woo et al. Characterization of modern alloys is presented by the articles of Wollmershauser et al., Eidenberger et al., Garlea et al., Jia et al., Soulami et al., Wilson et al., and Wang et al. The collected articles are written by different scientific X-ray and neutron research groups. They represent a general trend in the development and application of diffraction techniques all over the world.

36 MATERIALS SCIENCE↗

Distribution of unresolvable anisotropic microstructures revealed in visibility-contrast images using x-ray Talbot interferometry

X-ray Talbot interferometry has been widely used as a technique for x-ray phase imaging and tomography. We propose a method using this interferometry for mapping distribution of parameters characterizing anisotropic microstructures, which are typically of the order of {mu}m in size and cannot be resolved by the imaging system, in a sample. The method uses reduction in fringe visibility, which is caused by such unresolvable microstructures, in moire images obtained using an interferometer. We applied the method to a chloroprene rubber sponge sample, which exhibited uniaxial anisotropy of reduced visibility. We measured the dependencies of reduced visibility on both the Talbot order and the orientation of the sample and obtained maps of three parameters and their anisotropies that characterize the unresolvable anisotropic microstructures in the sample. The maps indicated that the anisotropy of the sample's visibility contrast mainly originated from the anisotropy of the microstructure elements' average size. Our method directly provides structural information on unresolvable microstructures in real space, which is only accessible through the ultra-small-angle x-ray scattering measurements in reciprocal space, and is expected to be broadly applied to material, biological, and medical sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Bismuth Metal–Organic Framework as a Contrast Agent for X-ray Computed Tomography

A new bismuth metal–organic framework (MOF), bismuth-NU901 (Bi-NU-901), featuring the scu topology and a pore with a diameter of ~11 Å, was solvothermally synthesized, and its use as an X-ray computed tomography (CT) contrast agent was tested. X-ray CT is a common diagnostic method used in the medical field. Inside the body, contrast media enhance the distinction between tissues and organs of similar density. Bi-NU-901 consists of eight connected Bi 6 nodes and tetratopic 1,3,5,8-( p -benzoate)pyrene linkers (TBAPy). Numerous material characterization studies including powder X-ray diffraction (PXRD), scanning transmission electron microscopy (STEM), and DFT pore size distribution support the scu structure. Additionally, given the framework’s high density of nontoxic heavy atoms, Bi-NU-901 was evaluated as an X-ray computed tomography (CT) agent. Importantly, in vitro studies revealed this new bismuth MOF demonstrates p7 times better contrast intensity compared to a zirconium MOF featuring the same topology and ~14 times better contrast than a commercially available CT contrast agent. Furthermore these results suggest bismuth MOFs may be promising CT contrast agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The characterization of secondary electron emitters for use in large area photo-detectors.

The Large-Area Picosecond Photo-Detector Project is focused on the development of large-area systems to measure the time-of-arrival of relativistic particles with, ultimately, 1 pico-second resolution, and for signals typical of Positron-Emission Tomography (PET), a resolution of about 30 pico-seconds. Our contribution to this project is to help with identification and efficient fabrication of novel electron emitting materials with properties optimized for use in such detectors. We have assembled several techniques into a single ultra-high vacuum apparatus in order to enable characterization of both photocathode and secondary electron emission (SEE) materials. This apparatus will examine how photocathode quantum efficiency and SEE material electron yield correlate to surface chemical composition, state, and band structure. The techniques employed in this undertaking are X-ray photoelectron spectroscopy (XPS) for surface chemical composition, ultraviolet photoelectron spectroscopy (UPS) for the determination of band structure and surface work function, as well surface cleaning techniques such as argon-ion sputtering. To determine secondary electron emission yields and quantum efficiencies of detector materials, we use electron optics from a low energy electron diffraction (LEED) system whose set of hemispherical electrodes allows for efficient collection of secondary and photo electrons. As we gain a stronger insight into the details of mechanisms of electron emission from photocathodes and SEE materials, we will be able to lay a foundation for the larger collaborative effort to design the next generation of large-area photo-detectors. We present our preliminary results on the SEE materials from our as-yet completed characterization system.

43 PARTICLE ACCELERATORS↗

Structure evolution and tin redistribution during oxidation of Zircaloy-4 at 500°C

Zirconium (Zr) alloys are widely used as fuel cladding in nuclear power reactors due to their thermal stability, mechanical durability, corrosion resistance, and low neutron absorption cross-section. However, their performance is challenged by oxidation in reactor environments, making the study of Zr alloy corrosion behavior crucial for ensuring the safety, longevity, and economic viability of nuclear power systems. While the oxidation behavior of Zr-based cladding materials has been extensively studied since the 1950s, a mechanistic understanding into the relationship between structure evolution, solute element redistribution, and properties remains elusive. Valuable insights may be obtained through advanced experimental methods, such as in-situ and high resolution microscopy techniques. Here, in this study, the oxidation behavior of Zircaloy-4 at 500 °C in O 2 is characterized using a multimodal advanced characterization approach. Using in-situ X-ray diffraction, the phase evolution from metastable to stable oxides is tracked in real time. Complementary high-resolution techniques, including electron microscopy and atom probe tomography, reveal nanoscale insights into the microstructural changes and solute redistribution across the oxide/metal interface. Nanohardness mapping across the oxide/metal interface highlights localized mechanical property variations that may be linked to changes in microstructure and crystal structure within the oxide layer. These findings offer valuable insights into the microstructure and property evolution of Zircaloy-4 during oxidation, contributing to a better understanding of microstructural changes in Zr-based alloys under oxidative environments.

APT↗

Nanoscale phase separation in epitaxial Cr-Mo and Cr-V alloy thin films studied using atom probe tomography: Comparison of experiments and simulation

Tailored metal alloy thin film-oxide interfaces generated using molecular beam epitaxy (MBE) deposition of alloy thin films on a single crystalline oxide substrate can be used for detailed studies of irradiation damage response on the interface structure. However, the presence of nanoscale phase separation in the MBE grown alloy thin films can impact the metal-oxide interface structure. Due to nanoscale domain size of such phase separation, it is very challenging to characterize by conventional techniques. Therefore, laser assisted atom probe tomography (APT) was utilized to study the phase separation in epitaxial Cr{sub 0.61}Mo{sub 0.39}, Cr{sub 0.77}Mo{sub 0.23}, and Cr{sub 0.32}V{sub 0.68} alloy thin films grown by MBE on MgO(001) single crystal substrates. Statistical analysis, namely frequency distribution analysis and Pearson coefficient analysis of experimental data was compared with similar analyses conducted on simulated APT datasets with known extent of phase separation. Thus, the presence of phase separation in Cr-Mo films, even when phase separation was not clearly observed by x-ray diffraction, and the absence of phase separation in the Cr-V film were confirmed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Grazing-Incidence Texture Tomography and Diffuse Reflectivity Tomography of an Organic Semiconductor Device Array

The use of grazing-incidence scattering methods for the characterization of 2D patterned organic thin films is limited due to the elongated 1D footprint of the X-ray beam on the sample. However, this characteristic feature can be turned into an advantage, when combined with tomographic reconstruction. In this pilot study we show, how the use of a chosen texture reflection and a diffuse reflectivity signal can each provide 2D images of the deposits, simultaneously revealing the organic film's crystal orientation and the location of the metal electrodes in a field-effect transistor structure from a single sequence of diffraction images.

36 MATERIALS SCIENCE↗

Microstructure characterization by X-ray tomography and EBSD of porous FeCr produced by liquid metal dealloying

Highlights: • FeCr-Ni precursors were dealloyed in a Mg bath to give FeCr-Mg bicontinuous structure. • FeCr-Mg bicontinuous structure was immersed in HNO{sub 3} solution to get porous FeCr. • (FeCr){sub x}-Ni{sub 1−x} precursors are fully FCC phase while porous FeCr are fully BCC phase. • Composition & dealloying parameters are key parameters for controlling microstructure - Abstract: Liquid metal dealloying is a promising technique to get nanoporous materials which are attractive for their excellent functional properties. From a (FeCr){sub x}-Ni{sub 1−x} precursor, it is possible to get porous FeCr with this technique. While immersing precursors in a molten Mg bath, Ni atoms selectively migrate into the Mg bath. After cooling down to room temperature, the resulting microstructure is a bi-continuous structure of FeCr and Mg (with Ni in solid solution). A final etching step removes the Mg solid-state solution phase. Precursors with different compositions were dealloyed and imaged in 3D. From X-ray tomography images, porous FeCr characteristics as solid fraction, phase size, specific surface were extracted. EBSD maps were acquired on samples before and after dealloying. We will show that precursor composition is a key parameter to control pores and grains size while dealloying parameters (time and temperature) are key parameters to control ligaments size and in fine specific surface. By controlling precursor composition and dealloying parameters it is now possible to get dealloyed nanoporous metals with desired grain and porous microstructure by liquid metal dealloying.

36 MATERIALS SCIENCE↗