Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Production of Medically Desirable Radioisotopes in the EIRENE Molten Salt Reactor

Radioisotopes play a vital role in nuclear medicine, enabling the performance of diagnostic procedures such as Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), in addition to innovative targeted therapies for selectively delivering cytotoxic radiation doses to tumor cells while minimizing damage to healthy tissue [1]. Beta emitting radionuclides such as 90Y and 131I find wide use in radio-immunotherapy, with the radiopharmaceuticals 90Y-ibritumomab tiuxetan (Zevalin®) and 131I-tositumomab (Bexxar®) having received FDA approval for treatment of non-Hodgkin’s lymphoma through targeting the CD20 surface receptor, which is commonly expressed in many B cell non-Hodgkin’s lymphoma subtypes [2, 3]. 90Y has also been successfully applied for treatment of brain tumors [4, 5] and liver cancer [6]. The favorable chelation chemistry of 90Y enables its use with a variety of ligands for the development of radiopharmaceuticals suitable for targeting different carcinoma types [1].

42 - ENGINEERING↗

Niowave Ancillary Systems – FY21: In Partial Fulfillment of the Deliverable Requirement for Niowave Ancillary Systems Support by LANL

Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.

36 MATERIALS SCIENCE↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Novel Proppant Logging Technique for Infill Drilling of Unconventional Shale Wells

Summary During the development of an unconventional play, wells are drilled and completed in batches, and depending on the development plans, current and expected energy market trends, as well as other developmental considerations, new wells are drilled and hydraulically fractured later near existing producing laterals. This creates challenges in terms of optimizing resource recovery and reducing interwell communication. A novel approach is proposed that utilizes systematic composite sampling and analysis of drilling mud returns to look for and quantitatively identify sand particles. The workflow involves cleaning, drying, and segregation of samples into sizes of interest to us (size distribution of pumped proppant in offset parent wells). These samples are imaged at a very high resolution and analyzed for grains using characteristic optical imaging properties to classify proppant sand particles using computer vision algorithms. Further analysis, such as elemental compositional analysis, is used to validate the results from the imaging workflow. We present a case study from the Permian Basin, where a new child well was used as a test case to prove this technology at the Hydraulic Fracturing Test Site (HFTS-2) in Delaware Basin. We introduce new proppant parameters that help identify sustained proppant zones vs. localized propped fractures. We have used additional diagnostics and data collected at the test site to validate observations from the proppant log and have successfully interpreted significantly propped vs. unpropped zones. A key finding from this test has been the significant proppant transport distances observed away from parent wells. Observable proppant was found at a lateral distance of approximately 425 m for one set of parent wells and more than 915 m for another set of parent wells. While a major limitation of this technique is the sampling rate, given adequate sampling, the proposed technology represents a systematic and one-of-a-kind interpretation of spatial proppant distribution while drilling infill wells. It provides us with unique opportunities to better understand the current state of the reservoir being targeted, including zones that are likely highly drained relative to others, and how the planned hydraulic fracturing of child wells can be improved.

Energy & Fuels↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

140° Line of Sight (LOS) Mounting Fixture Prototype for ZNeutron Time of Flight (Z-NToF)

The 140° Line of Sight (LOS) Mounting Fixture Prototype for the Z-Neutron Time of Flight diagnostic (Z-NToF) is a prototype support structure for the NToF Jac Black that will be fielded at Sandia’s Z-Machine. The Mounting Fixture will allow the detector to be properly positioned and aligned horizontally from the load, with manual horizontal and vertical translation capabilities, and a limited manual rotation capability. It attaches overhead I-beams at Sandia’s Z machine 140° location approximately 18m from the average source location. The assembly (1011219955) is shown in Figure 1 below. It is capable of rotating ±20° about the vertical axis of the Jac Black detector and translating ±37.5mm horizontally along the Mounting Plate. Vertical adjustments of ±76.2mm can be made using the Lead Screw. Coarser adjustments are possible by changing the number of plates between the I-Beam Hanger Assemblies and the 5in and changing the position of the clamps on the I-beams at Z.

42 ENGINEERING↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

Sensor Impact Evaluation and Verification Technical Advisory Group Meeting Minutes

This report provides the technical advisory group meeting minutes and summary of detailed discussions for future development of sensor impact evaluations and verifications. Methods for sensor configuration/deployment have critical impacts on energy-efficient building control and thermal comfort. However, traditional sensor techniques for building operation and fault detection and diagnostics (FDD) are not optimal in terms of energy efficiency and thermal comfort, and their global effects are not thoroughly investigated. In an effort to address and overcome this limitation, a 3 year project, Sensor Impact Evaluation and Verification, was proposed. The multi-laboratory team—the US Department of Energy’s Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and the National Renewable Energy Laboratory (NREL)—is conducting early-stage R&D to provide technical supports and guidelines for sensor design in building/HVAC systems to optimize building energy use, FDD, thermal comfort, and grid efficiency. The overall goal of this project is to develop a framework that enables quantitative evaluation of the impact of sensors on building HVAC control, FDD, and consequently, building energy efficiency and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Acoustic Analysis of Batteries

The project explored development and commercialization of an acoustical approach to battery diagnostics. The technology has significant potential impacts for battery manufacturing and quality assurance, battery management during operation, and could be an enabler for the second-life battery market. Research was focused on inspecting and analyzing the physical condition of batteries using ultrasound. This consisted of designing and building hardware for gathering high-quality acoustic data, as well as using battery charge-discharge cyclers and temperature chambers to operate and age the batteries. Over the course of the 2-year program, we were able to build our first prototypes that are robust enough to be used by industry partners to evaluate our technology. Using the same prototypes, we also showed preliminary evidence that our acoustic inspection method may have distinct advantages over standard electrical methods in terms of detecting differences in the physical quality of battery cells. The project also expanded the participant’s core capabilities beyond time-of-flight acoustic measurements.

25 ENERGY STORAGE↗

Recent Progress of JT-60SA Project toward Plasma Operation

Superconducting tokamak JT-60SA plays an essential role in fusion research and development by supporting and complementing ITER project, providing directions to the DEMO design activity and fostering next generation scientists and engineers. Since the incident of the Equilibrium Field coil #1 during the Integrated Commissioning (IC) in March 2021, both EU and JA Implementing agencies (IAs) have examined how to ensure safety operation of JT-60SA by mitigating the risk of possible discharge occurrence inside the cryostat. Based on the experience of the Global Paschen tests, the IAs have established a strategy of risk mitigation measures, which is a combination of (i) reinforcement of insulation, (ii) avoiding unnecessary voltage application to the coil systems and (iii) immediate de-energization of the coils when deteriorated vacuum condition is detected. Thanks to the considerable efforts of the Integrated Project Team (IPT) members, the IC restarted in May 2023. After the confirmation of superconducting state of coil systems (TF, EF and CS), the coil energization test and the plasma operation (OP-1) starts. The first plasma was successfully achieved on 23 October 2023 with a limited value of applied voltage and current to the coils. The plasma configuration control will be also confirmed with low plasma current and low auxiliary heating power conditions. Based on the IO-F4E-QST collaboration, activities of JT-60SA have been shared with the IO and provided an important lesson learned for ITER assembly and commissioning, and will provide an outstanding contribution to fusion research at large. After OP-1, Maintenance & Enhancement phase 1 (M/E-1) starts from January 2024, in which in-vessel components are installed, and heating system and diagnostic system are extensively upgraded to allow high power heating experiment planned in OP-2. In order to make the best use of JT-60SA, newly organized JT-60SA experiment team will refine the research plan in the future high heating power operation phase.

Broader Approach activities↗

Millimeter-wave electromagnetic monitoring for liquid metal droplet-on-demand printing

As new printing approaches emerge, in situ diagnostics to monitor the print quality in real-time become essential for long-term monitoring and feedback control. In this article, we present a millimeter-wave electromagnetic monitoring approach for liquid metal droplet-on-demand printing to support the high-speed and real-time evaluation of droplet ejection. An open-ended rectangular waveguide is placed perpendicular to a jetted droplet stream and operated at a continuous-wave frequency of 40 GHz. Liquid metal droplets with diameters as low as 1.2 mm are characterized, and droplet jetting events on the order of 500 μm are detected at ejection rates up to 80 Hz. The measured results demonstrate that trends at the macro-level (large-scale print variation and anomalies at the nozzle tip) as well as micro-level (droplet size, position, and dynamics) can be detected using this technique.

42 ENGINEERING↗

A fast, matrix-based method to perform omnidirectional pressure integration

Abstract Experimentally-measured pressure fields play an important role in understanding many fluid dynamics problems. Unfortunately, pressure fields are difficult to measure directly with non-invasive, spatially resolved diagnostics, and calculations of pressure from velocity have proven sensitive to error in the data. Omnidirectional line integration methods are usually more accurate and robust to these effects as compared to implicit Poisson equations, but have seen slower uptake due to the higher computational and memory costs, particularly in 3D domains. This paper demonstrates how omnidirectional line integration approaches can be converted to a matrix inversion problem. This novel formulation uses an iterative approach so that the boundary conditions are updated each step, preserving the convergence behavior of omnidirectional schemes while also keeping the computational efficiency of Poisson solvers. This method is implemented in Matlab and also as a GPU-accelerated code in CUDA-C++. The behavior of the new method is demonstrated on 2D and 3D synthetic and experimental data. Three-dimensional grid sizes of up to 125 million grid points are tractable with this method, opening exciting opportunities to perform volumetric pressure field estimation from 3D PIV measurements.

42 ENGINEERING↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

Particle Image Velocimetry and Total Temperature Characterization of Arc-Heated Mach 4.5 Free Jet

Particle image velocimetry (PIV) measurements were conducted in the Arc-Heated Combustion Tunnel (ACT-II) on a high-enthalpy Mach 4.5 nozzle flow. The primary motivation for the current work is to establish the feasibility of PIV as a high-quality flow diagnostic technique in hypersonic arc-heated flows and produce a high-resolution hypersonic nozzle flow characterization, including nozzle free jet shear layer velocity profiles. Due to the uncertain nature of the gas composition in the flowfield of interest, PIV measurements of a supersonic wedge flow were used to couple the flow velocities to the oblique shock relations. This enabled a PIV-derived total temperature calculation that does not require a priori assumptions of the exact gas composition. A PIV expansion module was developed for this study, and proper seed sizing and material were selected for the present flow. An analysis of the seed particle response from the PIV measurements provided an initial validation of the seed performance while revealing potential issues with consistent seed sizing. These measurements and derived conditions represent a means of acquiring high-resolution velocimetry and temperature datasets that consider uncertainties in the experimental generation of hypersonic high-enthalpy flows.

Engineering↗

In-situ and in-operando analysis of voltage losses using sense wires for proton exchange membrane water electrolyzers

Proton exchange membrane water electrolyzer development requires understanding processes at the materials and interface levels to reach the required performance and lifetime targets for increasing market penetration. To achieve the required progress, it is critical to develop advanced in-situ diagnostics that allow observation of the changes that come with the reduction of catalyst loading combined with long-term intermittent operation. This work presents an internal voltage sensing method that enables observing internal voltage drops in an operating electrolyzer cell. It allows the total cell resistance to be separated into anode, CCM, and cathode resistance. The method is demonstrated by operating cells with different anode porous transport layers (PTLs). The changing properties of the PTLs result in significant variations of the resistances. Enhancing the PTL properties with a protective coating reduces the anode resistance significantly. In addition to these observations, the method enables a real-time monitoring of resistance related values that impact performance in water electrolyzers. Long-term experiments with the method allow us to gain insights into processes that occur during operation such as conditioning or degradation. The internal voltage sensing method presented in this study is a novel technique for diagnosing, analyzing, and optimizing water electrolyzers and other energy conversion devices.

42 ENGINEERING↗