Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Scorpius Accelerator Emittance Diagnostic Design

The 14th International Particle Accelerator Conference (IPAC’23) will be held in Venice, Italy from 7 to 12 May 2023 at the Venice Convention Centre. Website: https://www.ipac23.org/ Presenter: Mark Raphaelian Dear Mark, we acknowledge reception of your abstract #1268 for IPAC'23 - 14th International Particle Accelerator Conference. Here follow the details: Title: The Design of the Emittance Diagnostic for the Scorpius Accelerator Classification: MC6.T03: Beam Diagnostics and Instrumentation Type of presentation: Poster Presentation Submitter: Mark Raphaelian Authors: Mark Raphaelian Co-Authors: Daniel Dzenitis, Franz Weber, Nathaniel Pogue, Sean Littleton, Steven Falabella, Patrick Duffy, William Stem

47 OTHER INSTRUMENTATION↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

A portable ion-energy diagnostic for transformative ARPA-E Fusion R&D

The Princeton Plasma Physics Laboratory seeks to develop a diagnostic to measure the energy distribution of ions (IED) in innovative confinement concept devices being investigated under ARAP-E grants. The Princeton Field-Reversed Configuration (PFRC) fusion project aims to develop small, simple, and clean fusion power generators in the 1–10 MW “micro-reactor” class. The PFRC explores a new approach to fusion power-generation design, prioritizing low radioactivity and modular units of MEW-scale power output. The team’s proposed power plant design provides a small footprint for a compact, potentially transportable energy source that is fully deployable and emissions-free. A critical diagnostic to accomplish this mission and to test the theory of ion heating necessary for fusion in PFRC reactors is called a stripping-cell ion-energy analyzer (SC-IEA).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Dependent Boundary Modeling to Inform Design of SPARC Diagnostic and Actuators

The purpose of this work was to inform the design of diagnostic and actuator systems for a new experimental facility for Commonwealth Fusion Systems (CFS), called SPARC [Creely2020], using time-dependent plasma boundary simulations with the Scrape Off Layer Plasma Simulator (SOLPS) code [Wiesen2015]. The SPARC tokamak is a device that aims to demonstrate fusion energy production and high-field plasma operating scenarios. The developed technologies will be incorporated into a net-electricity pilot that will demonstrate approximately 200MW of electric power. A major difference from other private industry fusion companies is the use of a standard aspect ratio, but at a high magnetic field strength, which provides a well-established physics basis and a modest extrapolation to reactor operation. Time-dependent simulations were used to inform the design of main-chamber plasma facing components, which are protected by feedback control of the heat and particle loads during high power operation. The simulations provide the timescales and magnitudes of plasma and neutral particle response useful for determining the position and operation of diagnostics and actuators that will enable control. The plasma response and phase-space diagrams also provide input into advanced model-based control schemes, which are envisioned for later SPARC operation. Model-based control can reduce the risk of component failure, which would require expensive in-situ repairs and the associated delays, by predicting the system response to actuators over a short time-horizon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics, Prognostics, and Optimization for Lithium-Ion Battery Systems

Health management of lithium-ion battery systems presents a host of challenges due to their complex physics, large numbers of components, and a wide variety of degradation behaviors across different battery types. Dr. Paul Gasper will present on research from the Electrochemical Energy Storage Group on Lithium-ion battery diagnostics, prognostics, and optimization. Diagnostics research, including state-estimation via machine-learning from electrochemical impedance spectroscopy and DC pulses as well as continuous state-estimation via Kalman filters, will highlight the ongoing challenges for accurately measuring the state of batteries without performing time-consuming characterization tests. NLR's industry-recognized battery prognostics work, which predicts real-world battery degradation by identifying degradation rate models from accelerated aging data using statistical modeling and machine-learning, will be used to demonstrate the critical impact of battery controls, thermal management, and operating strategy on durability and lifetime. Finally, the use of prognostic models for financial or lifetime optimization will be discussed.

25 ENERGY STORAGE↗

FY26 Mid-Year Report Self-Diagnostic Capabilities for Neutron Instruments

This year we will transfer the latest version of INCC6 with last year’s self-diagnostic features to the IAEA. In FY25 we completed the development of three automated self diagnostic features into INNC6. The completion of these features marked the final stable version of INCC 6.0 ready for release to the IAEA and other users. In the first half of the Fiscal Year 2026 we have worked with LANL’s Feynman Center and Export Control office to attain a license for exporting INCC6 to the IAEA. We have successfully attained the export license for INCC6, and contacts at the IAEA have been granted permission to receive INCC6. We are in the final stage of writing the version 6 user manual. Once this is complete, we will deliver INCC6 to the IAEA for testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

Image-Guided Intraoperative Assessment of Surgical Margins in Oral Cavity Squamous Cell Cancer: A Diagnostic Test Accuracy Review

The assessment of resection margins during surgery of oral cavity squamous cell cancer (OCSCC) dramatically impacts the prognosis of the patient as well as the need for adjuvant treatment in the future. Currently there is an unmet need to improve OCSCC surgical margins which appear to be involved in around 45% cases. Intraoperative imaging techniques, magnetic resonance imaging (MRI) and intraoral ultrasound (ioUS), have emerged as promising tools in guiding surgical resection, although the number of studies available on this subject is still low. The aim of this diagnostic test accuracy (DTA) review is to investigate the accuracy of intraoperative imaging in the assessment of OCSCC margins. By using the Cochrane-supported platform Review Manager version 5.4, a systematic search was performed on the online databases MEDLINE-EMBASE-CENTRAL using the keywords “oral cavity cancer, squamous cell carcinoma, tongue cancer, surgical margins, magnetic resonance imaging, intraoperative, intra-oral ultrasound”. Ten papers were identified for full-text analysis. The negative predictive value (cutoff < 5 mm) for ioUS ranged from 0.55 to 0.91, that of MRI ranged from 0.5 to 0.91; accuracy analysis performed on four selected studies showed a sensitivity ranging from 0.07 to 0.75 and specificity ranging from 0.81 to 1. Image guidance allowed for a mean improvement in free margin resection of 35%. IoUS shows comparable accuracy to that of ex vivo MRI for the assessment of close and involved surgical margins, and should be preferred as the more affordable and reproducible technique. Both techniques showed higher diagnostic yield if applied to early OCSCC (T1–T2 stages), and when histology is favorable.

60 APPLIED LIFE SCIENCES↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative comparisons of electron-scale turbulence measurements in NSTX via synthetic diagnostics for high-k scattering.

Two synthetic diagnostics are implemented for the high-k scattering system in NSTX [D. R. Smith, E. Mazzucato, W. Lee, H. K. Park, C. W. Domier, and N. C. Luhmann Jr., Rev. Sci. Instrum., 79, 123501 (2008)] allowing direct comparisons between synthetic and experimentally detected frequency and wavenumber spectra of electron-scale turbulence fluctuations. Synthetic diagnostics were formulated in real-space and in wavenumber space, and were deployed to realistic electron-scale simulations carried out with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186 (2003) 545]. A highly unstable ETG regime (electron temperature gradient mode) in a modest beta NSTX NBI-heated H-mode discharge was chosen for the analysis. Mapping the measured wavenumbers to field aligned coordinates showed that the high-k system is sensitive to fluctuations that are closer to the spectral peak in the density fluctuation wavenumber spectrum (streamers) than originally predicted. Analysis of synthetic spectra show that the frequency response of the detected fluctuations is dominated by Doppler shift and insensitive to the turbulence drive. The shape of the high-k density fluctuation wavenumber spectrum is sensitive to the ETG turbulence drive conditions, and can be reproduced in a sensitivity scan of the most pertinent turbulent drive terms in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material injection alleviation and plasma diagnostic measurements during the RAM C-III flight.

The results of a material injection RF blackout alleviation experiment and of plasma diagnostic measurements using electrostatic probes and an S-band reflectometer in a 25,000 ft/sec reentry flight are presented. Significant alleviation of RF blackout is observed at altitudes of from 270,000 feet to 120,000 feet due to injection of water and Freon E-3 on VHF, S-band, C-band, and X-band frequencies. Electrostatic probe data, attenuation data, and S-band diagnostic data show consistent plasma results. The relative effectiveness of water and Freon E-3 is discussed.

Schroeder, L. C.↗

Diagnostic device for monitoring the technical condition of mechanical assemblies

An automatic diagnostic device for monitoring the condition of tractor transmission gears is described. The structural noise spectrum of the gearshift box and rear axle of the tractor were analyzed in a digital computer, by an algorithm based on the multiple correlation method. The optimum assembly of operating frequencies, by use of which the errors in measurement were minimized, was selected from the entire frequency spectrum. Selected frequencies are necessary for choosing the measurement range of the diagnostic device. It turned out that, to obtain a relative error of no more than 2%, it was sufficient to use two filters, vibrating only at the frequencies carrying the maximum data of the mechanical parameter being investigated. The measurement system consists of frequency-selection filters, amplifiers and quadratic detectors, at the outlets of which constant voltages are created, which are proportional to the signal level at the frequencies selected.

Osovskiy, V. I.↗

Cold plasma diagnostics using satellite measurements of VLF signals from ground transmitters

A diagnostic technique to obtain the cold-plasma density profile in the magnetosphere is introduced. This method uses satellite measurements of group delay and pulse duration of VLF signals from ground transmitters in conjunction with a detailed ray-tracing analysis. An iterative method is involved which starts with an approximate density profile, computes the ray paths for that profile, and then compares the properties of the rays that reach the satellite location with the actual satellite measurements. The density profile is then modified to account for any discrepancies between the two results. The same process is repeated with the new profile until one has reasonable agreement between the data and ray-tracing results. This method is applied to the case of an Imp 6 pass, where strong signals from the Siple VLF transmitter were observed for over 25 min. Good agreement is found between the results of the proposed technique and the well-known ground whistler techniques of cold-plasma diagnostics. The results also serve to illustrate the wide diversity of propagation paths from ground transmitters to high-altitude satellites during VLF wave-injection experiments.

Inan, U. S.↗

Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth-telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented.

Rosell, F. E., Jr.↗