Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

43 PARTICLE ACCELERATORS↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

Benchmarking fast-neutron response of 7 Li-enriched C 7 LYC scintillators: Simulations and experiment

New insights into the fast neutron response of 7 Li-enriched C 7 LYC scintillators have been obtained through detailed Geant4 simulations of 35 Cl(n,p) and 35 Cl(n, α) reactions that are primarily responsible for the fast neutron response of C 7 LYC. The light output of a 1” x1” C 7 LYC detector was simulated using the Birks equation for light quenching in scintillators. The simulations were benchmarked against neutron scattering data from a 12 C target obtained with a white neutron beam at the Los Alamos LANSCE facility and fourteen 1”x1” C 7 LYC detectors. Incident neutron energies extracted from time-of-flight measurements, and appropriate recoil corrections for the different detector angles were used to map the response of C 7 LYC to mono-energetic neutrons. Resonances in the 35 Cl(n,p) reaction cross-section below 3 MeV incident neutron energy were directly observed in C 7 LYC. The experimental data and simulations are compared with ENDF databases, as well as recent direct cross-section measurements of neutrons scattered from a 35 Cl target. In conclusion, the results suggest a scrutiny of the 35 Cl(n,p) and 35 Cl(n, α) cross sections at low energy in the ENDF library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Protons in the NOvA Test Beam

The NOvA (NuMI Off-Axis electron neutrino Appearance) Experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors, a 300 ton Near Detector, and a 14 kton Far Detector separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA's rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, and probing CP violation in the leptonic sector. The NOvA Test Beam experiment deployed at Fermilab between 2018 and 2022 used a scaled-down 30 ton detector to analyse tagged beamline particles. The beamline selected and identified electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.8 GeV/c, as understanding how the detector responds to these particles found in the final state of neutrino interactions is crucial. This poster shows preliminary results from studies of proton response in the NOvA Test Beam detector.

Bannister, Emerson [Sussex U.] (ORCID:000000027535↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

System and method for compact, adaptive optical sensor for obtaining areal images

The present disclosure relates to an imaging system which may make use of an electronic controller, a digital micromirror array, an aperture control system and a detector to image a desired scene. The digital micromirror array has a plurality of micromirror elements responsive to control signals generated by the electronic controller for electronically aiming the micromirror elements in a desired direction to image the desired area, and for receiving and reflecting light emanating from the desired area. The aperture control system receives light reflected from the digital micromirror array and passes a predetermined subportion of the received light therethrough. The detector is responsive to the predetermined subportion of light.

Panas, Robert Matthew↗

Simulation of gallium nitride vertical fin-shaped field effect transistor for use as thermal neutron detector

Through the use of a radiation detection system simulation framework, a gallium nitride vertical fin-shaped field effect transistor (FinFET) was studied for output response when utilized as a thermal neutron detector. The FinFET was assumed to had been backfilled with boron carbide, reactive to thermal neutrons. The GaN FinFET was modeled with radiation transport from MCNP, and the electronic transport from COMSOL Multiphysics. Fabricated FinFET devices (not neutron reactive) were tested to aid in the tuning of the COMSOL FinFET model. Through time-depenent studies, the drain current response pulse to simulated ionization due to single events lead to building of a database of device responses to radiation. By integrating the current pulses over time, the induced charge was calculated. Using the results of the radiation transport PTRAC file in combination with the induced charge database, an integrated charge spectrum was calculated.

Davidson, Bryce L.↗

Mitigation and characterization of crosstalk between laser-driven radiography sources

Radiography with multiple probe species offers the potential to extract additional information about a given object as compared to radiography with a single probe species. Notably, the flexibility for high-power, short-pulse lasers to accelerate a variety of particle species makes laser-driven sources an attractive option to achieve multi-probe radiography. However, crosstalk produced by each of laser-driven source may be responsible for substantial backgrounds on detectors, becoming a significant barrier to achieving simultaneous radiography. In this work, we describe measurements of and mitigation strategies against crosstalk between laser-driven radiography sources in experiments at the OMEGA EP laser.

47 OTHER INSTRUMENTATION↗

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

BM3DORNL

BM3DORNL is a high-performance, open-source library for removing streak and ring artifacts from computed-tomography (CT) data, developed for neutron imaging at Oak Ridge National Laboratory's Spallation Neutron Source (VENUS beamline) and applicable to X-ray CT as well. Ring artifacts — concentric rings in reconstructed slices caused by detector pixel-to-pixel response non-uniformities — appear as vertical streaks in the sinogram and degrade both image quality and quantitative analysis. BM3DORNL operates in the sinogram domain using an adaptation of the BM3D (block-matching and 3D collaborative filtering) algorithm (Dabov et al., 2007). It provides a dedicated streak-removal mode, a true multi-scale BM3D variant (after Mäkinen et al., 2021) that suppresses wide streaks single-scale methods miss, and an alternative Fourier–SVD method (~2.6× faster) combining FFT-based energy detection with rank-1 SVD. The computationally intensive core is implemented in Rust with parallel (Rayon) block matching, integral-image pre-screening, and optimized transforms, and is exposed through a simple Python API (with an optional GUI) so it integrates directly into existing tomography reconstruction pipelines. It processes both 2D sinograms and 3D sinogram stacks, is pip-installable for Linux and macOS, and is documented at https://bm3dornl.readthedocs.io.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗