Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Simulation of ideal-gas flow by nitrogen and other selected gases at cryogenic temperatures

The real gas behavior of nitrogen, the gas normally used in transonic cryogenic tunnels, is reported for the following flow processes: isentropic expansion, normal shocks, boundary layers, and interactions between shock waves and boundary layers. The only difference in predicted pressure ratio between nitrogen and an ideal gas which may limit the minimum operating temperature of transonic cryogenic wind tunnels occur at total pressures approaching 9 atm and total temperatures 10 K below the corresponding saturation temperature. These pressure differences approach 1 percent for both isentropic expansions and normal shocks. Alternative cryogenic test gases were also analyzed. Differences between air and an ideal diatomic gas are similar in magnitude to those for nitrogen and should present no difficulty. However, differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. It is concluded that helium and cryogenic hydrogen would not approximate the compressible flow of an ideal diatomic gas.

Hall, R. M.↗

Flow visualization in the Langley 0.3-meter Transonic Cryogenic Tunnel and preliminary plans for the National Transonic Facility

Design problems associated with the integration of flow visualization in cryogenic facilities are discussed. The possible effects from the cryogenic environment (i.e., window distortion due to thermal contraction both in the mounts and in the window material itself and turbulence in the flow due to injected LN2) are examined. The flow visualization techniques studied are schlieren, shadowgraph, moire deflectometry, and holographic interferometry. The test beds for this work are a Langley in-house cryogenic test chamber and the 0.3-Meter Transonic Cryogenic Tunnel.

Rhodes, D. B.↗

Possible safety hazards associated with the operation of the 0.3-m transonic cryogenic tunnel at the NASA Langley Research Center

The 0.3 m Transonic Cryogenic Tunnel (TCT) at the NASA Langley Research Center was built in 1973 as a facility intended to be used for no more than 60 hours in order to verify the validity of the cryogenic wind tunnel concept at transonic speeds. The role of the 0.3 m TCT has gradually changed until now, after over 3000 hours of operation, it is classified as a major NASA research facility and, under the administration of the Experimental Techniques Branch, it is used extensively for the testing of airfoils at high Reynolds numbers and for the development of various technologies related to the efficient operation and use of cryogenic wind tunnels. The purpose of this report is to document the results of a recent safety analysis of the 0.3 m TCT facility. This analysis was made as part of an on going program with the Experimental Techniques Branch designed to ensure that the existing equipment and current operating procedures of the 0.3 m TCT facility are acceptable in terms of today's standards of safety for cryogenic systems.

Webster, T. J.↗

Dimensional stability considerations for cryogenic metals

Work performed as part of an effort to identify, and where possible separate out, some of the factors that contribute to dimensional stability in cryogenic wind tunnel models is reported. Initial problems were encountered with two dimensional models made of 15-5 PH stainless steel, which warped significantly after being subjected to cryogenic testing in the 0.3 Meter Transonic Cryogenic Tunnel. Subsequently, an effort was undertaken to investigate the mechanisms that could cause model warpage during cryogenic testing. The two basic mechanisms that can lead to warpage are (1) metallurgical structural instability in which one phase transforms partially or fully into a second phase which has a different crystal structure and volume, and (2) deformation due to the creation, or relief, of unbalanced induced or residual stresses. In the case of the 15-5 PH airfoils, it is highly probable that metallurgical instability was responsible for most of the observed warpage. A particular specimen configuration was established for use in the systematic evaluation of the factors influencing warpage. Preliminary studies of a specimen made of VASCOMAX 200 suggest the possibility of manipulating the stresses in the surface layers by appropriate combinations of milling and grinding steps. This opens up the possibility of correcting or establishing the required surface profile of an airfoil.

Wigley, D. A.↗

Metallurgical studies of NITRONIC 40 with reference to its use for cryogenic wind tunnel models

The characterstics of NITRONIC 40 were investigated in connection with its use in cryogenic wind tunnel models. In particular, the effects of carbide and sigma-phase precipitation resulting from heat treatment and the presence of delta ferrite were evaluated in relation to their effects on mechanical properties and the potential consequences of such degradation. Methods were examined for desensitizing the material and for possible removal of delta ferrite as a means of restoring the material to its advertised properties. It was found that heat treatment followed by cryogenic quenching is a technique capable of desensitizing NITRONIC 40. However, it was concluded that it is extremely difficult, if not impossible, to remove the delta ferrite from the existing stock of material. Furthermore, heat treatments for removing delta ferrite have to take place at temperatures that cause very large grain growth. The implications of using the degraded NITRONIC 40 material for cryogenic model testing were reviewed, and recommendations were submitted with regard to the acceptability of the material. The experience gained from the study of NITRONIC 40 clearly identifies the need to implement a policy for purchasing top-quality materials for cryogenic wind tunnel model applications.

Wigley, D. A.↗

Cryogenic wind tunnels for high Reynolds number testing

The present investigation has the objective to provide an overview of the development of cryogenic wind tunnels and their application to high Reynolds number testing. The current need for wind tunnels reflects the fact that many complex three-dimensional flows cannot yet be adequately dealt with analytically. Imperfections of wind tunnels are partly related to the fact that for most wind tunnel tests the Reynolds number is much too low. The best solution to this problem appears to be an operation of the tunnel at cryogenic temperatures (arbitrarily defined as temperatures of 150 K or less. In addition to decreasing the temperature, there are three other approaches for increasing the Reynolds number. These approaches include the use of a heavy gas, an increase in the model size, and an increase in pressure. Attention is given to the variable density tunnel concept, problems with high dynamic pressures, low-speed cryogenic tunnel results, transonic cryogenic tunnel tests, and the injection of liquid nitrogen into the tunnel.

Kilgore, R. A.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

Design of a precision etalon position control system for a cryogenic spectrometer

The Upper Atmosphere Research Satellite (UARS) will be launched in 1988 to study the distribution of a series of trace elements in the upper atmosphere and to study atmospheric dynamics. The UARS carries on board a cryogenically cooled infrared spectrometer to measure the concentration of a series of chemical species that are important for understanding the ozone layer in the stratosphere. This device, known as the Cryogenic Limb Array Etalon Spectrometer (CLAES), uses a multiposition filter wheel combined with tilt-scanned Fabry Perot etalons to obtain the high resolution required for these experiments. The CLAES optical system is sealed in a dewar where it is maintained at cryogenic temperatures by a supply of solid hydrogen. Operating temperatures for CLAES range from 130 K at the entrance aperture to 13 K at the focal plane. The design and test of a special control system using a unique actuator concept to provide position and can control for the CLAES etalon are described. Results of performance tests at cryogenic temperatures simulating the CLAES on-orbit environment are discussed.

Aubrun, J. N.↗

Grain-refining heat treatments to improve cryogenic toughness of high-strength steels

The development of two high Reynolds number wind tunnels at NASA Langley Research Center which operate at cryogenic temperatures with high dynamic pressures has imposed severe requirements on materials for model construction. Existing commercial high strength steels lack sufficient toughness to permit their safe use at temperatures approaching that of liquid nitrogen (-320 F). Therefore, a program to improve the cryogenic toughness of commercial high strength steels was conducted. Significant improvement in the cryogenic toughness of commercial high strength martensitic and maraging steels was demonstrated through the use of grain refining heat treatments. Charpy impact strength at -320 F was increased by 50 to 180 percent for the various alloys without significant loss in tensile strength. The grain sizes of the 9 percent Ni-Co alloys and 200 grade maraging steels were reduced to 1/10 of the original size or smaller, with the added benefit of improved machinability. This grain refining technique should permit these alloys with ultimate strengths of 220 to 270 ksi to receive consideration for cryogenic service.

Rush, H. F.↗

An analytical study of reusable flight-weight cryogenic propellant tank designs

Thermostructural analyses of reusable flight-weight cryogenic tanks for a vertically launched space vehicle have been conducted. An analytical procedure was developed for sizing the tank structure, cryogenic insulation, and thermal protection system. Unstiffened, integrally-stiffened, and honeycomb core sandwich tank skins using aluminum or stainless steel materials were compared for their ability to meet design criteria at least weight. Cryogenic insulation systems were also evaluated, including closed-cell cryogenic foams and evacuated honeycomb core. The results indicate that a 400 F foam-insulated unstiffened-skin aluminum tank structure is the lightest structure for either LOX or LH2 tanks that meet the selected design criteria, but only two to four percent lighter than a stiffened aluminum tank.

Taylor, A. H.↗

Cryogenic wind tunnels for high Reynolds number testing

The evolution and early development of cryogenic wind tunnels is reviewed, and consideration is given to current and future research in cryogenic wind tunnel testing. Emphasis is placed on the problem of low Reynolds numbers in current cryogenic wind tunnel tests as well as flow instability, wall interference and support interference which can inhibit a reliable simulation of complex three-dimensional flows. The operating characteristics of several of the worlds low-speed and high-speed cryogenic wind tunnel testing facilities are presented in the form of several graphs and photographs.

Kilgore, R. A.↗

Initial Investigation of Cryogenic Wind Tunnel Model Filler Materials

Filler materials are used for surface flaws, instrumentation grooves, and fastener holes in wind tunnel models. More stringent surface quality requirements and the more demanding test environment encountered by cryogenic wind tunnels eliminate filler materials such as polyester resins, plaster, and waxes used on conventional wind tunnel models. To provide a material data base for cryogenic models, various filler materials are investigated. Surface quality requirements and test temperature extremes require matching of coefficients of thermal expansion or interfacing materials. Microstrain versus temperature curves are generated for several candidate filler materials for comparison with cryogenically acceptable materials. Matches have been achieved for aluminum alloys and austenitic steels. Simulated model surfaces are filled with candidate filler materials to determine finishing characteristics, adhesion and stability when subjected to cryogenic cycling. Filler material systems are identified which meet requirements for usage with aluminum model components.

Firth, G. C.↗

Introduction to cryogenic wind tunnels

The background to the evolution of the cryogenic wind tunnel is outlined, with particular reference to the late 60's/early 70's when efforts were begun to re-equip with larger wind tunnels. The problems of providing full scale Reynolds numbers in transonic testing were proving particularly intractible, when the notion of satisfying the needs with the cryogenic tunnel was proposed, and then adopted. The principles and advantages of the cryogenic tunnel are outlined, along with guidance on the coolant needs when this is liquid nitrogen, and with a note on energy recovery. Operational features of the tunnels are introduced with reference to a small low speed tunnel. Finally the outstanding contributions are highlighted of the 0.3-Meter Transonic Cryogenic Tunnel (TCT) at NASA Langley Research Center, and its personnel, to the furtherance of knowledge and confidence in the concept.

Goodyer, M. J.↗

The NASA Langley 0.3-m transonic cryogenic tunnel

The Langley 0.3-m Transonic Cryogenic Tunnel (0.3-m TCT) can operate from ambient to cryogenic temperatures at absolute pressures from 1 to 6 bars. Since the 0.3-m TCT began operation in 1973, it has been used to develop instrumentation and operating techniques for cryogenic tunnels as well as for aerodynamic tests where advantage can be taken of the extremely wide range of Reynolds number available. This paper describes the present capabilities of the 0.3-m TCT and gives an overview of recent research activities which include both steady and unsteady testing. Emphasis is given to safety and the development of testing techniques for cryogenic tunnels. Results of studies aimed at establishing the lower limits of operating temperature are presented and the impact of these studies on tunnel operation is discussed. Finally, the design features and operating characteristics of a new self-streamlining wall test section recently installed in the tunnel circuit are described.

Kilgore, R. A.↗

A summary of Reynolds number effects on some recent tests in the Langley 0.3-meter transonic cryogenic tunnel

Reynolds number effects noted from selected test programs conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT) are discussed. The tests, which cover a unit Reynolds number range from about 2.0 to 80.0 million per foot, summarize effects of Reynolds number on: (1) aerodynamic data from a supercritical airfoil, (2) results from several wall interference correction techniques, and (3) results obtained from advanced, cryogenic tests techniques. The test techniques include: (1) use of a cryogenic sidewall boundary layer removal system, (2) detailed pressure and hot wire measurements to determine test section flow quality, and (3) use of a new hot film system suitable for transition detection in a cryogenic wind tunnel. The results indicate that Reynolds number effects appear most significant when boundary layer transition effects are present and at high lift conditions when boundary layer separation exists on both the model and the tunnel sidewall.

Johnson, C. B.↗

Preliminary experiments on surface flow visualization in the cryogenic wind tunnel by use of condensing or freezing gases

Cryogenic wind tunnel users must have available surface flow visualization techniques to satisfy a variety of needs. While the ideal from an aerodynamic stand would be non-intrusive, until an economical technique is developed there will be occasions when the user will be prepared to resort to an intrusive method. One such method is proposed, followed by preliminary evaluation experiments carried out in environments representative of the cryogenic nitrogen tunnel. The technique uses substances which are gases at normal temperature and pressure but liquid or solid at cryogenic temperatures. These are deposited on the model in localized regions, the patterns of the deposits and their subsequent melting or evaporation revealing details of the surface flow. The gases were chosen because of the likelihood that they will not permanently contaminate the model or tunnel. Twenty-four gases were identified as possibly suitable and four of these were tested from which it was concluded that surface flow direction can be shown by the method. Other flow details might also be detectable. The cryogenic wind tunnel used was insulated on the outside and did not show signs of contamination.

Goodyer, M. J.↗

Development of a space qualified Surface Tension Confined Liquid Cryogen Cooler (STCLCC)

The Surface Tension Confined Liquid Cryogen Cooler (STCLCC), a new type of cryogenic cooler which is being developed by the NASA-GSFC for spaceflight payloads, is described. The STCLCC will be capable of maintaining instrumentation within the temperature range of 10-120 K and will allow liquid cryogens to be flown in space without the risk of liquid being entrained in the vent gas. A low-density open-cell material in the STCLCC acts as a 'sponge', with the surface tension trapping the liquid cryogen within its pores and keeping the liquid away from the cooler's vent during launch, zero-g operations, and landing. It is emphasized that the STCLCC concept is amenable to a wide variety of applications, whenever a passive low-cost cooler is required or when the on-orbit service of a cooler would increase a mission's lifetime.

Castles, Stephen H.↗

Cryogenic Insulation System

This invention relates to reusable, low density, high temperature cryogenic foam insulation systems and the process for their manufacture. A pacing technology for liquid hydrogen fueled, high speed aircraft is the development of a fully reusable, flight weight cryogenic insulation system for propellant tank structures. In the invention cryogenic foam insulation is adhesively bonded to the outer wall of the fuel tank structure. The cryogenic insulation consists of square sheets fabricated from an array of abutting square blocks. Each block consists of a sheet of glass cloth adhesively bonded between two layers of polymethacrylimide foam. Each block is wrapped in a vapor impermeable membrane, such as Kapton(R) aluminum Kapton(R), to provide a vapor barrier. Very beneficial results can be obtained by employing the present invention in conjunction with fibrous insulation and an outer aeroshell, a hot fuselage structure with an internal thermal protection system.

Davis, Randall C.↗