Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “core sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

CHANDRA DISCOVERY OF 10 NEW X-RAY JETS ASSOCIATED WITH FR II RADIO CORE-SELECTED AGNs IN THE MOJAVE SAMPLE

The Chandra X-ray Observatory has proven to be a vital tool for studying high-energy emission processes in jets associated with active galactic nuclei (AGNs). We have compiled a sample of 27 AGNs selected from the radio flux-limited MOJAVE (Monitoring of Jets in AGNs with VLBA Experiments) sample of highly relativistically beamed jets to look for correlations between X-ray and radio emission on kiloparsec (kpc) scales. The sample consists of all MOJAVE quasars that have over 100 mJy of extended radio emission at 1.4 GHz and a radio structure of at least 3'' in size. Previous Chandra observations have revealed X-ray jets in 11 of 14 members of the sample, and we have carried out new observations of the remaining 13 sources. Of the latter, 10 have X-ray jets, bringing the overall detection rate to {approx}78%. Our selection criterion, which is based on highly compact, relativistically beamed jet emission and large extended radio flux, thus provides an effective method of discovering new X-ray jets associated with AGNs. The detected X-ray jet morphologies are generally well correlated with the radio emission, except for those displaying sharp bends in the radio band. The X-ray emission mechanism for these powerful FR II (Fanaroff-Riley type II) jets can be interpreted as inverse Compton scattering off of cosmic microwave background photons by the electrons in the relativistic jets. We derive viewing angles for the jets, assuming a non-bending, non-decelerating model, by using superluminal parsec scale speeds along with parameters derived from the inverse Compton X-ray model. We use these angles to calculate best-fit Doppler and bulk Lorentz factors for the jets, as well as their possible ranges, which leads to extreme values for the bulk Lorentz factor in some cases. When both the non-bending and non-decelerating assumptions are relaxed the only constraints on the kpc-scale jet from the Chandra and Very Large Array observations are an upper limit on the viewing angle, and a lower limit on the bulk Lorentz factor.

79 ASTRONOMY AND ASTROPHYSICS↗

Nevada Higher Education Benefits from US Department of Energy (DOE) Environmental Management (EM) Nevada Program's Transfer of Geologic Samples - 20442

The Nevada National Security Site (NNSS), formerly the Nevada Test Site, was the location of 100 historic atmospheric and 828 historic underground nuclear tests from 1951 to 1992. Related to this historic nuclear testing, geologic and hydrologic studies of the site were conducted utilizing the skills and the expertise of the U.S. Geological Survey (USGS) and national laboratories (Los Alamos National Laboratory, Lawrence Livermore National Laboratory), who were principal in leading the development of weapons and were responsible for specific underground testing programs. The subsurface samples and technical/scientific data associated with NNSS geologic studies (past and present) are preserved and stored at the USGS Mercury Core Library and Data Center located at the NNSS. Currently, the facility stores over 2,000,000 linear feet of cores and cuttings from more than 2,600 drill holes that can be accessed for study. Most of the samples and historic geologic work was focused directly on subsurface geologic settings that relate directly to historic underground nuclear testing. Since 1992, the United States has observed a unilateral moratorium on full-scale nuclear testing, and the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program is now responsible for hydrogeologic characterization of the potential impacts to the natural groundwater systems that may have resulted from historic underground nuclear tests. As part of this effort, the EM Nevada Program Underground Test Area (UGTA) Activity has drilled and completed over 58 deep (2,000 - 7,000 ft.) characterization wells, totaling in excess of 170,000 linear feet of cuttings and core samples. Cutting samples were collected as triplicate samples for each respective depth interval, to account for potential later nondestructive/destructive analysis and to preserve samples for regulatory purposes. Recently, it was recognized by the EM Nevada Program that opportunities may exist to reduce the cost and floor space required for the storage of geologic samples at the Mercury Core Library without impacting the integrity and representative nature of the samples necessary for project execution. An initiative was sponsored by EM Nevada Program to evaluate several options: 1) disposal of a portion of cuttings and cores in a land fill setting; 2) reduction in sample volume through skeletonizing core and cuttings from wells to a representative but much smaller number of samples; and 3) solicit potential interest in the academic community where other geoscientists could freely access the samples for studies. The Nevada state university system through the Nevada Bureau of Mines and Geology responded positively to the opportunity to receive these NNSS samples from the EM Nevada Program. In June 2019, approximately 17,000 geologic samples, representing greater than 170,000 linear feet of drilling and weighing over 20,000 pounds, were shipped from the NNSS to the Great Basin Science Sample and Records Library located in Reno, Nevada. The benefits resulting from this transfer were realized by the EM Nevada Program in terms of cost and space savings for geologic sample storage at the NNSS. The transfer did not impact the EM Nevada Program mission as access to representative geologic samples for regulatory and scientific purposes was preserved. Moreover, the Nevada Bureau of Mines and Geology acquired a significant resource of subsurface geologic samples and supporting technical data to support academic and scientific studies in a complex volcanic setting in southwest Nevada. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Trail Creek in Taylor River Watershed, Colorado 2024-2025

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Trail Creek. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format TR-X-Y, where TR refers to Trail Creek, X is the treatment block identifier, and Y is the location identifier. Specifically, TR-ASCC1 is the control treatment block under the Adaptive Silviculture for Climate Change (ASCC) project, and TR-ASCC2 is the clear-cut treatment block. TR-ASCC-EHSn is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and TR-ASCC-ERTn (upslope n=1) are ecohydrology sites along the electrical resistivity tomography transects. The sample and location information can be found in metadata.csv, and the data from the soil sensors will be included in a future data version when the observation period becomes sufficiently long for data analysis. Sampling and Measurements Each sample falls into one of the two sampling methods – (1) intact cores or (2) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. The intact cores were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Geology and Hydrothermal Alteration of the Raft River Geothermal System, Idaho

The Raft River geothermal system is located in southern Idaho, near the Utah-Idaho state boarder in the Raft River Valley. The field, which is owned and operated by U.S. Geothermal, has been selected as an EGS demonstration site by the U. S. Department of Energy. This paper summarizes ongoing geologic and petrologic investigations being conducted in support of this project. The reservoir is developed in fractured Proterozoic schist and quartzite, and Archean quartz monzonite cut by younger diabase intrusions. The basement complex was deformed during the mid Tertiary and covered by approximately 5000 ft of late Tertiary sedimentary and volcanic deposits. Listric normal faults of Cenozoic age disrupt the Tertiary deposits but do not offset the basement rocks. RRG-9, the target well, was drilled southwest of the main well field to a measured depth (MD) of 6089 ft. The well is deviated to the west and cased to a depth of 2316 ft MD. It penetrated the Proterozoic reservoir rocks at a depth of 5286 ft MD and encountered a maximum temperature of 139 degrees C. Bottomhole temperatures in other deep wells range from 133 to 149 degrees C. X-ray diffraction and thin section analyses are being conducted on samples from 5 deep wells, RRG- 1, 2, 3, 7 and 9, to determine the characteristics of the rock types and hydrothermal alteration within the geothermal system. Thin section analyses of samples from RRG-9 document the presence of strong alteration and brecciation at the contact between the Tertiary and basement complex. The Tertiary rocks consist of ash-flow tuffs, lava flows, tuffaceous siltstone, greywacke, and sandstone. No core is available from RRG-9 but core was obtained from RRG-3C. The sample is a brecciated and altered siltstone from the base of the Tertiary sequence and is similar to rocks at the base of the Tertiary deposits in RRG-9. Here, the results of thermal and quasi-static mechanical property measurements that were conducted on the core sample are presented.

Jones, Clay↗

Data Package of Samples Collected for Hydrogeologic and Geochemical Characterization: 300 Area RI/FS Sediment Cores

This is a data package for sediment samples received from the 300 FF 5 OU. This report was prepared for CHPRC. Between August 16, 2010 and April 25, 2011 sediment samples were received from 300-FF-5 for geochemical studies. The analyses for this project were performed at the 331 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibration requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL.

300 Area, Charaterization, Sediment↗

CRITICAL MINERAL PARTITIONING IN COAL-HOSTED CLAYS OF THE POWDER RIVER BASIN, WY DETERMINED BY SEQUENTIAL EXTRACTION

Increasing demand for a more robust domestic supply of rare earth elements (REE) and critical minerals (CM) has led to significant investigation into unconventional sources. Coal and coal byproducts from the Powder River Basin (PRB) of Wyoming are potential sources of REE and CM. The association between strategic metals and their mineral hosts has important implications for extractability. Samples of overburden, underclays, and clay-rich partings were selected for analysis from core and bucket samples from three PRB coal mines. Quartz, illite, and kaolinite-group minerals are abundant in clay-rich portions of the PRB coal strata. We performed a five-step sequential extraction to constrain critical metal partitioning in samples of overburden and underclays (n=10). Unlike the occurrences of REE in other clay deposits, insignificant amounts of total REE + Y (TREY) were recovered in the ion-exchangeable fraction (< 0.5 ppm). A significant amount of TREY was leached from the acid-soluble fraction by 0.1M HCl, suggesting REE may be tied up within crystal lattices rather than sorbed to clay surfaces. The acid-soluble fraction contained between 3 and 250 ppm TREY, with an average TREY concentration of 60 ppm. Relative standard deviations for each extraction step were generally < ±10%. Whole-rock samples (n=72) contained greater TREY enrichment in overburden than in underclays and partings, however, the opposite is true for other CM, such as Ti and V. Other locations in the PRB show different enrichment trends. Our findings supplement a broader effort to couple REE and CM extraction with existing domestic coal production and contribute to the fundamental understanding of how these metals concentrate in low-temperature basin environments.

Stuart, Sophia↗

Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration

A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.

6-around-1 cable↗

Isotope Ratio Method Analysis of the WWR-SM Reactor

In this paper, we use the Isotope Ratio Method (IRM) to estimate the total energy production of the Uzbekistan Institute of Nuclear Physics WWR-SM research reactor. The isotope ratio method is a technique for verifying the operational history of a nuclear reactor by measuring trace element isotope ratios in non-fuel reactor components. The isotope ratios in these components can then be directly related to cumulative energy production with standard reactor modeling methods. This method has been successfully demonstrated on several shutdown reactors in the past. The WWR-SM is a 10MW pool reactor that has been operating since 1959. In 2013, a Pacific Northwest National Laboratory (PNNL) team successfully removed a surface sample from the aluminum core shroud during a refueling outage. The sample was subjected to Secondary Ionization Mass Spectrometry (SIMS) analysis at PNNL in 2014. Our results show good agreement with the actual operating history of the reactor.

Nuclear archeology, isotope ratio method, nonproli↗

EVALUATION OF THE DURABILITY OF THE STRUCTURAL CONCRETE OF REACTOR BUILDINGS AT SRS

The Department of Energy (DOE) intends to close 100-150 facilities in the DOE complex using an in situ decommissioning (ISD) strategy that calls for grouting the below-grade interior volume of the structure and leaving the above-grade interior open or demolishing it and disposing of it in the slit trenches in E Area. These closures are expected to persist and remain stable for centuries, but there are neither facility-specific monitoring approaches nor studies on the rate of deterioration of the materials used in the original construction or on the ISD components added during closure (caps, sloped roofs, etc). This report will focus on the evaluation of the actual aging/degradation of the materials of construction used in the ISD structures at Savannah River Site (SRS) above grade, specifically P & R reactor buildings. Concrete blocks (six 2 to 5 ton blocks) removed from the outer wall of the P Reactor Building were turned over to SRNL as the first source for concrete cores. Larger cores were received as a result of grouting activities in P and R reactor facilities. The cores were sectioned and evaluated using microscopy, x-ray diffraction (XRD), ion chromatography (IC) and thermal analysis. Scanning electron microscopy shows that the aggregate and cement phases present in the concrete are consistent with the mix design and no degradation mechanisms are evident at the aggregate-cement interfaces. Samples of the cores were digested and analyzed for chloride ingress as well as sulfate attack. The concentrations of chloride and sulfate ions did not exceed the limits of the mix design and there is no indication of any degradation due to these mechanisms. Thermal analysis on samples taken along the longitudinal axis of the cores show that there is a 1 inch carbonation layer (i.e., no portlandite) present in the interior wall of the reactor building and a negligible carbonation layer in the exterior wall. A mixed layer of carbonate and portlandite extends deeper into the interior (2-3 inches) and exterior (1-2 inches) walls. This is more extensive than measured in previous SRS structures. Once the completely carbonated layer reaches the rebar that is approximately 2-3 inches into the concrete wall, the steel is susceptible to corrosion. The growth rate of the carbonated layer was estimated from current observations and previous studies. Based on the estimated carbonation rate, the steel rebar should be protected from carbonation induced corrosion for at least another 100 years. If degradation of these structures is dominated by the carbonation mechanism, the length of time before water intrusion is expected into the process room of P-reactor is estimated to be between 425-675 years.

36 MATERIALS SCIENCE↗

Small-Angle Neutron Scattering Investigation of Oil Recovery in Mineralogically Distinct Wolfcamp Shale Strata

Understanding and improving hydrocarbon yields during enhanced oil recovery (EOR) in unconventional reservoirs is complicated by the intrinsic mineralogical and geochemical heterogeneity of shale formations. Here, in this study, we utilized small-angle neutron scattering (SANS) and ultra-small-angle neutron scattering (USANS) to investigate the degree of oil retention and its location in the nanoporous shale matrix for two mineralogically distinct shale samples. The two samples, dubbed “dark” and “light” based on their color, were taken from adjacent strata in a Wolfcamp shale core. While both samples contained kerogen, the dark sample contained more kerogen and clay (43.7 wt %) while the light sample contained more calcite (54.9 wt %). Samples were presaturated with decane, a model hydrocarbon, prior to pressure cycling with methane. Results showed significantly more retention of decane in 1.5–10 nm radius pores of both, likely indicating that oil is retained within kerogen nanopores. Although the dark sample had a higher porosity of 8.7%, versus 3.3% for the light sample, more pores were accessible to decane and a higher percentage of the imbibed decane was removable from the light sample compared to the dark sample. The majority of decane was not recoverable for the dark sample, indicating that EOR with methane can be challenging. These new findings can help to model expected recoveries of in-place oil from heterogeneous shale formations, as well as inform improved EOR strategies.

04 OIL SHALES AND TAR SANDS↗

Bioaugmentation of an Engineered Metal Treatment Wetland with Cupriavidus SRS

There are many chemical methods to remediate copper (Cu) from the environment. However, the use of microorganisms has been identified to be cheaper and more efficient in remediating toxic compounds in a method known as bioremediation. A microorganism, Cupriavidus SRS, is a metal resistant, rod shaped, gram negative bacteria that was isolated from a location with heavy metal contamination. As a predator this isolate has the ability to attack gram-negative and gram-positive bacteria. It is highly tolerant to Cu, and the isolates growth initiation is stimulated by Cu. Wang et al. (2015) determined that efflux pump activity is one of the most important mechanisms of heavy metal tolerance and the Cupriavidus genus demonstrates this behavior. In this study, Cupriavidus SRS will be inoculated to sediment and water from an area with high concentrations of Cu and zinc, to determine the ability of the isolate to grow and survive in a high level Cu wetland as well as the bioremoval efficiency. The H-02 wetland in the AL1 outfall area is an engineered wetland that was constructed to utilize natural processes associated with sediments and microbial communities to remove contaminants from waste waters at the Savannah River Site. Specifically, this wetland treats the building processes and runoff form the Tritium Processing Facility in H-area to prevent Cu and Zn from entering the water before the contaminants go in the Savannah River. Distributions of Cu and Zn follow organic matter levels with higher densities along the shoreline showing that metal concentrations correlate with organic matter content. Cupriavidus SRS Growth: Cupriavidus SRS was isolated at the Savannah River Site from an area with heavy metal contamination. Cultures were grown in R2A medium at 25 deg. C and shaken at 80 rpm for liquid cultures for 5 days. Sediment and Water Collection: All samples were collected from the AL1 Outfall area within the Department of Energy's Savannah River Site. Sediment cores, organic layer samples, and water samples were collected from the Inlet and Outlet cells in triplicate. Only water samples were collected from the basin. Cell Pellet: After centrifugation at 10,000 RPM for 10 minutes the supernatant was removed. 1 mL of phosphate buffer saline was added to the tube, vortexed, and recentrifuged. Inoculation of Sediment and Water: All samples were done in triplicate, vortexed after inoculation, and put on the shaker for 72 hours. Day 0 begins when the samples are removed from the shaker. Experimental Set-Up: All samples were done in triplicate. All sediment samples were centrifuged at 7500 RPM for 10 minutes on Day 0 and Day 5. All the sediment and water samples were filtered with a 0.2 μm nylon filters to obtain approximately 10 mL of supernatant on Day 0 and Day 3. pH was taken 24, 48, and 72 hours after the samples had been on the shaker. Plate Count: Plate counts were done on Day 0 and Day 3 to determine Cupriavidus SRS growth following a quantitative counting method from Seely et al. (1972). This project is ongoing and the goal is to determine if Cupriavidus SRS has the ability to uptake excess Cu out of the environment. These could be some possible results for the experiment: - The isolate uptakes too much Cu, dies, and releases Cu back into the environment. - The isolate is able to uptake Cu, continue to live, but chemically changes the environment introducing new problems. - The isolate is able to uptake Cu, continue to live, and does not disrupt the environment with toxic chemical changes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of Eu{sup 2+} on the blue‐green photoluminescence of In{sub 2}O{sub 3}:Eu{sup 2+} nanocrystals

Blue‐green light emitting undoped and europium doped indium oxide nanocrystal were synthesized by simple precipitation method. X-ray diffraction (XRD) pattern confirmed the cubic phase of undoped and europium doped samples. Further, transmission electron microscopy (TEM), scanning electron microscopy (SEM) , energy dispersive analysis of X-rays (EDAX), Fourier transform infra-red (FT-IR), photoluminescence (PL), electron paramagnetic resonance (EPR) studies were performed to characterise the samples. PL analysis of the samples is the core of the present research. It includes excitation, emission and CIE (Commission Internationale de l’e´ clairage) studies of the samples. On doping europium to In{sub 2}O{sub 3} lattice, ln{sup 3+} site is substituted by Eu{sup 2+} thereby increasing the concentration of singly ionized oxygen vacancy and hence blue–green emission from the host is found to increase. Further, this increase in blue–green emission after doping may also be attributed to 4f → 5d transitions of Eu{sup 2+}. However, the blue–green PL emission is found to decrease after an optimum dopant concentration (Eu{sup 2+} = 4%) due to luminescence and size quenching. CIE co-ordinates of the samples are calculated to know colour of light emitted from the samples. It suggests that this blue–green light emitting In{sub 2}O{sub 3}: Eu{sup 2+} nanocrystals may find application in lighting such as in generation of white light. - Highlight: • XRD and TEM study confirms the synthesis of cubic doped and europium doped nanocrystals. • EPR study reveals the doped europium is in + 2 oxidation state. • Enhance PL emission intensity of host material due to increase in singly ionized oxygen vacancy and 4f–5d transitions of Eu{sup 2+} • CIE co-ordinates suggest the blue–green colour of the samples.

36 MATERIALS SCIENCE↗

STAR FORMATION ACTIVITY OF CORES WITHIN INFRARED DARK CLOUDS

Infrared Dark Clouds (IRDCs) contain compact cores which probably host the early stages of high-mass star formation. Many of these cores contain regions of extended, enhanced 4.5 {mu}m emission, the so-called 'green fuzzies', which indicate shocked gas. Many cores also contain 24 {mu}m emission, presumably from heated dust which indicates embedded protostars. Because 'green fuzzies' and 24 {mu}m point sources both indicate star formation, we have developed an algorithm to identify star-forming cores within IRDCs by searching for the simultaneous presence of these two distinct indicators. We employ this algorithm on a sample of 190 cores found toward IRDCs, and classify the cores as 'active' if they contain a green fuzzy coincident with an embedded 24 {mu}m source, and as 'quiescent' if they contain neither IR signature. We hypothesize that the 'quiescent' cores represent the earliest 'preprotostellar' (starless) core phase, before the development of a warm protostar, and that the 'active' cores represent a later phase, after the development of a protostar. We test this idea by comparing the sizes, densities, and maser activity of the 'active' and 'quiescent' cores. We find that, on average, 'active' cores have smaller sizes, higher densities, and more pronounced water and methanol maser activity than the 'quiescent' cores. This is expected if the 'quiescent' cores are in an earlier evolutionary state than the 'active' cores. The masses of 'active' cores suggest that they may be forming high-mass stars. The highest mass 'quiescent' cores are excellent candidates for the elusive high-mass starless cores.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SUPERMASSIVE BLACK HOLE MASS-SPHEROID STELLAR MASS RELATION FOR SERSIC AND CORE-SERSIC GALAXIES

We have examined the relationship between supermassive black hole mass (M{sub BH}) and the stellar mass of the host spheroid (M{sub sph,*}) for a sample of 75 nearby galaxies. To derive the spheroid stellar masses we used improved Two Micron All Sky Survey K{sub s}-band photometry from the ARCHANGEL photometry pipeline. Dividing our sample into core-Sersic and Sersic galaxies, we find that they are described by very different M{sub BH}-M{sub sph,*} relations. For core-Sersic galaxies-which are typically massive and luminous, with M{sub BH} {approx}> 2 Multiplication-Sign 10{sup 8} M{sub Sun }-we find M{sub BH}{proportional_to} M{sub sph,*}{sup 0.97{+-}0.14}, consistent with other literature relations. However, for the Sersic galaxies-with typically lower masses, M{sub sph,*} {approx}< 3 Multiplication-Sign 10{sup 10} M{sub Sun }-we find M{sub BH}{proportional_to}M{sub sph,*}{sup 2.22{+-}0.58}, a dramatically steeper slope that differs by more than 2 standard deviations. This relation confirms that, for Sersic galaxies, M{sub BH} is not a constant fraction of M{sub sph,*}. Sersic galaxies can grow via the accretion of gas which fuels both star formation and the central black hole, as well as through merging. Their black hole grows significantly more rapidly than their host spheroid, prior to growth by dry merging events that produce core-Sersic galaxies, where the black hole and spheroid grow in lockstep. We have additionally compared our Sersic M{sub BH}-M{sub sph,*} relation with the corresponding relation for nuclear star clusters, confirming that the two classes of central massive object follow significantly different scaling relations.

79 ASTRONOMY AND ASTROPHYSICS↗

THE GROWTH OF COOL CORES AND EVOLUTION OF COOLING PROPERTIES IN A SAMPLE OF 83 GALAXY CLUSTERS AT 0.3 < z < 1.2 SELECTED FROM THE SPT-SZ SURVEY

We present first results on the cooling properties derived from Chandra X-ray observations of 83 high-redshift (0.3 < z < 1.2) massive galaxy clusters selected by their Sunyaev-Zel'dovich signature in the South Pole Telescope data. We measure each cluster's central cooling time, central entropy, and mass deposition rate, and compare these properties to those for local cluster samples. We find no significant evolution from z {approx} 0 to z {approx} 1 in the distribution of these properties, suggesting that cooling in cluster cores is stable over long periods of time. We also find that the average cool core entropy profile in the inner {approx}100 kpc has not changed dramatically since z {approx} 1, implying that feedback must be providing nearly constant energy injection to maintain the observed ''entropy floor'' at {approx}10 keV cm{sup 2}. While the cooling properties appear roughly constant over long periods of time, we observe strong evolution in the gas density profile, with the normalized central density ({rho}{sub g,0}/{rho}{sub crit}) increasing by an order of magnitude from z {approx} 1 to z {approx} 0. When using metrics defined by the inner surface brightness profile of clusters, we find an apparent lack of classical, cuspy, cool-core clusters at z > 0.75, consistent with earlier reports for clusters at z > 0.5 using similar definitions. Our measurements indicate that cool cores have been steadily growing over the 8 Gyr spanned by our sample, consistent with a constant, {approx}150 M{sub Sun} yr{sup -1} cooling flow that is unable to cool below entropies of 10 keV cm{sup 2} and, instead, accumulates in the cluster center. We estimate that cool cores began to assemble in these massive systems at z{sub cool}=1.0{sup +1.0}{sub -0.2}, which represents the first constraints on the onset of cooling in galaxy cluster cores. At high redshift (z {approx}> 0.75), galaxy clusters may be classified as ''cooling flows'' (low central entropy, cooling time) but not ''cool cores'' (cuspy surface brightness profile), meaning that care must be taken when classifying these high-z systems. We investigate several potential biases that could conspire to mimic this cool core evolution and are unable to find a bias that has a similar redshift dependence and a substantial amplitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Report: UT-GOM2-1 Sediment Grain Size Measurements at Site GC 955, Holes H002 and H005

Sediment grain size measurement in marine sediments provides a record of the stratigraphic variation in grain size and thus energy regime at the time of deposition. In addition to the grain size distribution, the degree of sediment sorting can also be calculated, and together they both influence primary sediment porosity and permeability. Here we present sediment grain size results from laser diffraction particle size analysis of samples from pressure cores collected during the 2017 UT GOM2-1 Expedition. We measured both bulk sediment and organic carbon-free sediment fractions for 46 samples and organic carbon-free sediment for 5 samples at Site GC 955, Holes H002 and H005. Differences between the bulk sediment and organic carbon-free fractions reflect the relative amount and size fraction of the organic carbon. The sample results presented here represent the grain size variation of the host lithology across the Green Canyon (GC) 955 gas hydrate reservoir.

03 NATURAL GAS↗

EVOLUTION OF DENSITY STRUCTURE OF STARLESS AND PROTOSTELLAR CORES

We present a near-infrared extinction study of nine dense cores at evolutionary stages between starless and Class I. Our results show that the density structure of all but one observed core can be modeled with a single power law rho {proportional_to} r{sup p} between {approx}0.2R-R of the cores. The starless cores in our sample show two different types of density structures, one follows p {approx} -1.0 and the other follows p {approx} -2.5, while the protostellar cores all have p {approx} -2.5. The similarity between the prestellar cores with p {approx} -2.5 and protostellar cores implies that those prestellar cores could be evolving toward the protostellar stage. The slope of p {approx} -2.5 is steeper than that of an singular isothermal sphere, which may be interpreted with the evolutionary model of cores with finite mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of Fast Reactor Depletion Tools Using EBR-II Measured Data

The validation of simulation tools for calculating fuel depletion and evolution in fast reactors is vital for design, licensing, deployment, operations, and material accountancy. The Physics Analysis Database (PADB) and Analytical Laboratory (AL) database contain measured data collected from Experimental Breeder Reactor II (EBR-II) and were used to validate the most recent versions of the Argonne Reactor Computation (ARC) tool suite and ORIGEN-S for calculating isotopic compositions in irradiated fast reactor fuel. The PADB contains important modeling and operational information about the EBR-II core design, fuel cycle, and analytical results from the legacy versions of the ARC tool suite. The AL database contains the measured isotopic compositions of irradiated samples taken from core subassemblies. A new procedure was developed for the ARC tool suite to perform the EBR-II depletion simulation, as well as to perform more detailed isotopic calculations using ORIGEN-S calculations by coupling it with the ARC suite. Both the ARC and ARC-ORIGEN results were compared with the AL measured data for all relevant samples and showed good agreement for the major actinides. Good agreement with measured data was also achieved using the ARC-ORIGEN approach for several fission products.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗