Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Experimental investigation of aerodynamic performance of cooled turbine vanes at gas- to collant-temperature ratios up to 2.75

The results of an experimental investigation of the aerodynamic performance of two geometrically similar turbine vanes with different cooling designs are presented. The test vanes were a convection-film-cooled vanes and a transpiration-cooled vane. A solid uncooled vane with the same aerodynamic profile as the cooled vane was also tested. Four vanes of each type were tested in an annular sector cascade. The cooled vanes were tested at primary to coolant temperature ratios of 1.0, 1.75, and 2.75 and a coolant to primary pressure ratios of 1.0, 1.2, and 1.5. This resulted in coolant flows up to about 10 percent of the primary flow. The principal measurements were surveys of vane exit total pressure, total temperature, and static pressure. The report includes a brief description of the test facility and the design of the test vanes. The test results presented include weight flow and efficiency data for the uncooled vanes and coolant flow, primary flow, and efficiency data as functions of the cooling variables for the cooled vanes.

Stabe, R. G.↗

An adverse effect of film cooling on the suction surface of a turbine vane

A J-75 size turbine vane with film cooling holes on the suction surface near the leading edge was tested with and without film cooling flow in a four vane cascade. Results show that the cooling effectiveness on the aft portion of the vane suction surface can decrease with the addition of film cooling near the leading edge. Apparently the film cooling air flow caused a laminar or transitional boundary layer to become a transitional or turbulent boundary layer. The vane was tested at a gas temperature and pressure of 1260 K (1800 F) and 22.7 newtons per square centimeter (33 psia), a coolant temperature of 280 K (50 F), film cooling flow ratios from 0.0 to 0.026, and backside midchord cooling flow ratios of 0.007 and 0.035.

Gladden, H. J.↗

Investigations of Air-Cooled Turbine Rotors for Turbojet Engines. 1: Experimental Disk Temperature Distribution in Modified J33 Split-Disk Rotor at Speeds up to 6000 RPM

An experimental investigation is being conducted at the Lewis laboratory to establish general principles for the design of noncritical turbine rotor configurations. This investigation includes evaluation of cooling effectiveness, structural stability, cooling-air flow distribution characteristics, and methods of supplying cooling air to the turbine rotor blades. Prior to design of a noncritical rotor, a standard turbine rotor of a commerical turbojet engine was split in the plane of rotation and machined to provide a passage for distributing cooling air to the base of each blade. The rotor was fitted with nontwisted, hollow, aircooled blades containing nine tubes in the coolant passage. In the investigation reported herein, the modified turbine rotor operated successfully up to speeds of 6000 rpm with ratios of cooling-air to combustion-gas flow as low as 0.02. The disk temperatures observed at these conditions were below 450 0 F when cooling air at 100 F was used from the laboratory air system. The calculated disk temperatures based on the correlation method presented for rated engine conditions were well below 1000 F at a cooling-air flow ratio of 0.02, which is considered adequate for a noncritical rotor. An appreciable difference in temperature level existed between the forward and rear disks. This temperature difference probably introduced undesirable disk stress distributions as a result of the relative elongations of the two disks. This investigation was terminated at 6000 rpm so that slight changes in the engine configuration could be made to relieve this condition.

Schramm, Wilson B.↗

Experimental Investigation of Air-Cooled Turbine Blades in Turbojet Engine. 7: Rotor-Blade Fabrication Procedures

An experimental investigation was conducted to determine the cooling effectiveness of a wide variety of air-cooled turbine-blade configurations. The blades, which were tested in the turbine of a - commercial turbojet engine that was modified for this investigation by replacing two of the original blades with air-cooled blades located diametrically opposite each other, are untwisted, have no aerodynamic taper, and have essentially the same external profile. The cooling-passage configuration is different for each blade, however. The fabrication procedures were varied and often unique. The blades were fabricated using methods most suitable for obtaining a small number of blades for use in the cooling investigations and therefore not all the fabrication procedures would be directly applicable to production processes, although some of the ideas and steps might be useful. Blade shells were obtained by both casting and forming. The cast shells were either welded to the blade base or cast integrally with the base. The formed shells were attached to the base by a brazing and two welding methods. Additional surface area was supplied in the coolant passages by the addition of fins or tubes that were S-brazed. to the shell. A number of blades with special leading- and trailing-edge designs that provided added cooling to these areas were fabricated. The cooling effectiveness and purposes of the various blade configurations are discussed briefly.

Long, Roger A.↗

Internal convective cooling systems for hypersonic aircraft

Parametric studies were conducted to investigate the relative merits of construction materials, coolants, and cooled panel concepts for internal convective cooling systems applied to airframe structures of hydrogen-fueled hypersonic aircraft. These parametric studies were then used as a means of comparing various cooled structural arrangements for a hypersonic transport and a hypersonic research airplane. The cooled airplane studies emphasized weight aspects as related to the choice of materials, structural arrangements, structural temperatures, and matching of the cooling system heat load to the available hydrogen fuel-flow heat sink. Consideration was given to reliability and to fatigue and fracture aspects, as well. Even when auxiliary thermal protection system items such as heat shielding, insulation, and excess hydrogen for cooling are considered the more attractive actively cooled airframe concepts indicated potential payload increases of from 40 percent to over 100 percent for the hypersonic transport as compared to the results of previous studies of the same vehicle configuration with an uncooled airframe.

Anthony, F. M.↗

Experimental verification of film-cooling concepts on a turbine vane

Film cooling concepts applied to gas turbine vanes were investigated. The filming cooling air was ejected from a single row of holes on the convex surface and a double row of holes of the concave surface. Tests were conducted at a gas temperature of 1260 K, a gas pressure of 3 atmospheres, and a coolant temperature of 280 K. Mass velocity ratios were varied between 0 and 2.0. Data were taken without film cooling holes, with film cooling holes but without blowing, and with blowing. A small amount of blowing into a nonturbulent boundary layer caused an increase in vane temperatures. Film cooling when combined with convection cooling was verified to be more effective than either film or convection cooling alone.

Gladden, H. J.↗

Experimental verification of film-cooling concepts on a turbine vane

An investigation was conducted to verify some film cooling concepts applied to gas turbine vanes. The film cooling air was ejected from a single row of holes on the convex surface and a double row of holes of the concave surface. Tests were conducted at a gas temperature of 1260 K, a gas pressure of 3 atmospheres, and a coolant temperature of 280 K. Mass-velocity ratios were varied between 0 and 2.0. Data were taken without film-cooling holes, with film-cooling holes but without blowing, and with blowing. A small amount of blowing into a nonturbulent boundary layer caused an increase in vane temperatures. Film cooling when combined with convection cooling was verified to be more effective than either film or convective cooling alone.

Gladden, H. J.↗

Crystallization history of lunar picritic basalt sample 12002 - Phase-equilibria and cooling-rate studies

Experimental crystallization of a lunar picrite composition (sample 12002) at controlled linear cooling rates produces systematic changes in the temperature at which crystalline phases appear, in the texture, and in crystal morphology as a function of cooling rate. Phases crystallize in the order olivine, chromium spinel, pyroxene, plagioclase, and ilmenite during equilibrium crystallization, but ilmenite and plagioclase reverse their order of appearance and silica crystallizes in the groundmass during controlled cooling experiments. The partition of iron and magnesium between olivine and liquid is independent of cooling rate, temperature, and pressure. Comparison of the olivine nucleation densities in the lunar sample and in the experiments indicates that the sample began cooling at about 1 deg C/hr. Pyroxene size, chemistry, and growth instability spacings, as well as groundmass coarseness, all suggest that the cooling rate subsequently decreased by as much as a factor of 10 or more. The porphyritic texture of this sample, then, is produced at a decreasing, rather than a discontinuously increasing, cooling rate.

Walker, D.↗

Effect of endwall cooling on secondary flows in turbine stator vanes

An experimental investigation was performed to determine the effect of endwall cooling on the secondary flow behavior and the aerodynamic performance of a coreturbine stator vane. The investigation was conducted in a cold-air, full-annular cascade, where three-dimensional effects could be obtained. Two endwall cooling configurations were tested. In the first configuration, the cooling holes were oriented so that the coolant was injected in line with the inviscid streamline direction. In the second configuration, the coolant was injected at an angle of 15 deg to the inviscid streamline direction and oriented toward the vane pressure surface. In both cases the stator vanes were solid and uncooled so that the effect of endwall cooling could be obtained directly. Total-pressure surveys were taken downstream of the stator vanes over a range of cooling flows at the design, mean-radius, critical velocity ratio of 0.778. Changes in the total-pressure contours downstream of the vanes were used to obtain the effect of endwall cooling on the secondary flows in the stator. Comparisons were made between the two cooled-endwall configurations and with the results obtained previously for solid endwalls.

Goldman, L. J.↗

Liquid rocket engine self-cooled combustion chambers

Self-cooled combustion chambers are chambers in which the chamber wall temperature is controlled by methods other than fluid flow within the chamber wall supplied from an external source. In such chambers, adiabatic wall temperature may be controlled by use of upstream fluid components such as the injector or a film-coolant ring, or by internal flow of self-contained materials; e.g. pyrolysis gas flow in charring ablators, and the flow of infiltrated liquid metals in porous matrices. Five types of self-cooled chambers are considered in this monograph. The name identifying the chamber is indicative of the method (mechanism) by which the chamber is cooled, as follows: ablative; radiation cooled; internally regenerative (Interegen); heat sink; adiabatic wall. Except for the Interegen and heat sink concepts, each chamber type is discussed separately. A separate and final section of the monograph deals with heat transfer to the chamber wall and treats Stanton number evaluation, film cooling, and film-coolant injection techniques, since these subjects are common to all chamber types. Techniques for analysis of gas film cooling and liquid film cooling are presented.

Source record↗

Review of the metallographic cooling rates of meteorites and a new model for the planetesimals in which they formed

The cooling rates of meteorites through approximately 900 -650 K, as read from their metal alloy compositions, are reviewed. Metallographic cooling rates are compared with the cooling rates that appear to be required by the K/Ar and Ar-40/Ar-39 ages of five meteorite classes, and discrepancies are found in all cases. Either (1) the metallographic cooling rates (and also Pu-244 fission cooling rates) are systematically in error, being too slow by a factor of approximately 6; or (2) the traditional thermal model for parent meteorite planets (having constant dimension and uniform physical properties) is oversimplified and the Ar closure temperatures for chondrites derived by Turner et al. (1978) are too low. An alternative parent planet model is proposed and numerically modeled, in which accretion of thermally insulating particulate matter, heat generation by Al-26 decay, melting or sintering of the particulate matter into conductive rock, and establishment of the properties of the meteorites occurred concurrently. Meteorite chronologies are somewhat easier to understand in this context, since the initially small, hot (thus sintered and conductive) bodies would have cooled rapidly to isotopic closure, but later cooling might have been much slower as a result of the continued accretion of insulating particulate matter.

Wood, J. A.↗

Film-cooling effectiveness with developing coolant flow through straight and curved tubular passages

The data were obtained with an apparatus designed to determine the influence of tubular coolant passage curvature on film-cooling performance while simulating the developing flow entrance conditions more representative of cooled turbine blade. Data comparisons were made between straight and curved single tubular passages embedded in the wall and discharging at 30 deg angle in line with the tunnel flow. The results showed an influence of curvature on film-cooling effectiveness that was inversely proportional to the blowing rate. At the lowest blowing rate of 0.18, curvature increased the effectiveness of film cooling by 35 percent; but at a blowing rate of 0.76, the improvement was only 10 percent. In addition, the increase in film-cooling area coverage ranged from 100 percent down to 25 percent over the same blowing rates. A data trend reversal at a blowing rate of 1.5 showed the straight tubular passage's film-cooling effectiveness to be 20 percent greater than that of the curved passage with about 80 percent more area coverage. An analysis of turbulence intensity detain the mixing layer in terms of the position of the mixing interface relative to the wall supported the concept that passage curvature tends to reduce the diffusion of the coolant jet into the main stream at blowing rates below about. Explanations for the film-cooling performance of both test sections were made in terms differences in turbulences structure and in secondary flow patterns within the coolant jets as influenced by flow passage geometry.

Papell, S. S.↗

Evaluation of Gas-Cooled Pressurized Phosphoric Acid Fuel Cells for Electric Utility Power Generation

Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas-cooling was already demonstrated in atmospheric pressure stacks. Theoretical and experimental investigations of gas-cooling for pressurized PAFC are presented. Two approaches to gas cooling, Distributed Gas-Cooling (DIGAS) and Separated Gas-Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

Faroque, M.↗

Evaluation of gas cooling for pressurized phosphoric acid fuel cell stacks

Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas cooling has already been demonstrated in atmospheric pressure stacks. This paper presents theoretical and experimental investigation of gas cooling for pressurized PAFC. Two approaches to gas cooling, Distributed Gas Cooling (DIGAS) and Separated Gas Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

Farooque, M.↗

Practical flight test method for determining reciprocating engine cooling requirements

It is pointed out that efficient and effective cooling of air-cooled reciprocating aircraft engines is a continuing problem for the general aviation industry. Miley et al. (1981) have reported results of a study regarding the controlling variables for cooling and installation aerodynamics. The present investigation is concerned with experimental methods which were developed to determine cooling requirements of an instrumented prototype or production aircraft, taking into account a flight test procedure which has been refined and further verified with additional testing. It is shown that this test procedure represents a straightforward means of determining cooling requirements with minimal instrumentation. Attention is given to some background information, the development history of the NACA cooling correlation method, and the proposed modification of the NACA cooling correlation.

Ward, D. T.↗

Application of formal optimization techniques in thermal/structural design of a heat-pipe-cooled panel for a hypersonic vehicle

Nonlinear mathematical programming methods are used to design a radiantly cooled and heat-pipe-cooled panel for a Mach 6.7 transport. The cooled portion of the panel is a hybrid heat-pipe/actively cooled design which uses heat pipes to transport the absorbed heat to the ends of the panel where it is removed by active cooling. The panels are optimized for minimum mass and to satisfy a set of heat-pipe, structural, geometric, and minimum-gage constraints. Two panel concepts are investigated: cylindrical heat pipes embedded in a honeycomb core and an integrated design which uses a web-core heat-pipe sandwich concept. The latter was lighter and resulted in a design which was less than 10 percent heavier than an all actively cooled concept. The heat-pipe concept, however, is redundant and can sustain a single-point failure, whereas the actively cooled concept cannot. An additional study was performed to determine the optimum number of coolant manifolds per panel for a minimum-mass design.

Camarda, Charles J.↗

Alternatives to the existence of large cooling flows

Arguments against the existence of large-scale cooling flows in clusters of galaxies are presented. The evidence for cooling flows is all circumstantial, consisting of observations of cool gas or hot gas with a radiative cooling time less than the Hubble time, or a central peak in the X-ray surface brightness profile. There is no evidence for large quantities (several tens to several hundreds of solar masses per year) of matter actually flowing anywhere. On the contrary, several lines of evidence suggest thaat cooling flows, if they exist, must be suppressed by one to two orders of magnitude from the values implied by simple estimates based on the radiative cooling time of the X-ray emitting gas. Two heat sources which might accomplish this, thermal conduction and relativistic particles, are considered, and an alternative to the standard model for cooling flows is presented: an accretion flow with feedback wherein the accretion of gas into a massive black hole in the central galaxy generates high energy particles that heat the gas and act to limit the accretion.

Tucker, Wallace↗