Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Coupling turbulent flow with blade aeroelastics and control modules in large-eddy simulation of utility-scale wind turbines

We present a large-eddy simulation framework capable of control co-design of large wind turbines, coupling the turbulent flow environment with blade aeroelastics and turbine controllers. The geometry and aerodynamics of the rotor blades and the turbine nacelle are parameterized using an actuator surface model. The baseline collective pitch control and individual pitch control (IPC) algorithms, consisting of a single-input, single-output proportional–integral controller and two integral controllers, respectively, are incorporated into the simulation framework. Furthermore, a second-order model based on the Euler–Bernoulli beam theory is implemented to describe the blade deformation. Simulations are carried out to investigate the impact of collective and individual pitch control strategies on the deflection of turbine blades. Our results show that the IPC reduces the blade tip deflection fluctuations in the out-of-plane direction, while the fluctuations of the blade tip deflection along the in-plane direction are barely affected by the IPC. Furthermore, the blade out-of-plane deformation fluctuation is underestimated by the one-way coupling approach compared to the two-way coupling approach. Furthermore, the findings of this study reveal the importance of advanced control systems in reducing the dynamic loads on wind turbine blades and underscore the potential of control co-design to reduce the levelized cost of wind energy.

42 ENGINEERING↗

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DSO+T: Expanded Study Results DSO+T Study: Volume 5

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. This report volume provides a detailed set of results for the DSO+T study extending results presented in Volumes 1, 2, and 4. The engineering and economic performance of the transactive energy scheme is presented for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of wind field characteristics and non-steady deterministic wind events on time-varying main-bearing loads

Abstract. This work considers the characteristics and drivers of the loads experienced by wind turbine main bearings. Simplified load response models of two different hub and main-bearing configurations are presented, representative of both inverting direct-drive and four-point-mounted geared drivetrains. The influences of deterministic wind field characteristics, such as wind speed, shear, yaw offset, and veer, on the bearing load patterns are then investigated for similarity scaled 5, 7.5, and 10 MW reference wind turbine models. Main-bearing load response in cases of deterministic gusts and extreme changes in wind direction are also considered for the 5 MW model. Perhaps surprisingly, veer is identified as an important driver of main-bearing load fluctuations. Upscaling results indicate that similar behaviour holds as turbines become larger, but with mean loads and load fluctuation levels increasing at least cubically with the turbine rotor radius. Strong links between turbine control and main-bearing load response are also observed.

17 WIND ENERGY↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Raspberry colloid-templated approach for the synthesis of palladium-based oxidation catalysts with enhanced hydrothermal stability and low-temperature activity

It is becoming increasingly urgent to develop and utilize novel, more efficient and stable materials for mobile and stationary emission control applications as the deleterious consequences of anthropogenic air pollution are becoming more evident and pressing. Tightening regulations, particularly related to automotive exhaust treatment, together with continued improvements in engine design, that result in lowering the engine operating temperatures and inadvertently lead to the release of an overwhelming proportion of pollutants during the cold start, present new challenges for materials design, specifically for oxidation catalysts. In particular, improvements in the low-temperature activity while maintaining catalyst stability at high temperatures are required from the next-generation catalyst. Typical catalysts for removal of pollutants from automotive exhaust streams incorporate platinum group metals (PGMs). They tend to be inefficient at low temperatures (below 250 °C), thus accounting for the cold start problem, yet sinter and lose their activity at high temperatures that are frequently encountered during catalyst operation. High PGM loadings are often employed to compensate for catalyst inefficiencies and fast degradation, ultimately resulting in high-cost catalytic converters. Here, we have developed a new approach for the design and formation of catalytic materials that allows for both significantly more efficient PGM incorporation and improved overall catalyst performance at reduced PGM loadings. The method provides control over the composition and geometry of the support through self-assembly of sacrificial composite template — “raspberry” polymeric colloids decorated with catalytic particles — accompanied by infiltration with metal-oxide precursor and subsequent removal of the colloids. This method simultaneously structures the porous network and organizes the catalytic particles within it. Uniquely, the resulting catalytic particles are partially embedded in the support matrix and partially exposed to the pore interior, producing catalytic sites that are both stable and accessible. Herein, the feasibility of this novel and versatile approach for automotive catalytic conversion is demonstrated: the studies include testing alumina-based raspberry-colloid-templated (RCT) catalysts containing Pd nanoparticles (RCT Pd/Al2O3) for oxidation of propane and carbon monoxide under simulated diesel exhaust conditions and hydrothermal aging at 800 °C for 50 h in the simulated stream. The RCT Pd/Al2O3 catalysts exhibit exceptional activity toward CO oxidation, reduced reaction onset temperature, and high stability to elevated temperatures (demonstrated through prolonged exposure to temperatures up to 950 °C) and reactive gas streams, without migration, sintering or loss of the precious metal NPs. Notably, the novel catalyst shows the same or slightly better performance than the commercial catalysts even when the PGM load is reduced by ~80 % compared to the commercial counterparts. These results provide confidence for the utilization of the RCT approach for the fabrication of robust nanostructured catalysts for next-generation, energy-efficient catalytic converters with improved performance at low and high temperatures and reduced costs. The RCT methodology is, in addition, highly generalizable, and can thus be applied for the design of a wide range of catalytic systems in the automotive sector and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structuring Nutrient Yields throughout Mississippi/Atchafalaya River Basin Using Machine Learning Approaches

To minimize the eutrophication pressure along the Gulf of Mexico or reduce the size of the hypoxic zone in the Gulf of Mexico, it is important to understand the underlying temporal and spatial variations and correlations in excess nutrient loads, which are strongly associated with the formation of hypoxia. This study’s objective was to reveal and visualize structures in high-dimensional datasets of nutrient yield distributions throughout the Mississippi/Atchafalaya River Basin (MARB). For this purpose, the annual mean nutrient concentrations were collected from thirty-three US Geological Survey (USGS) water stations scattered in the upper and lower MARB from 1996 to 2020. Eight surface water quality indicators were selected to make comparisons among water stations along the MARB over the past two decades. Principal component analysis (PCA) was used to comprehensively evaluate the nutrient yields across thirty-three USGS monitoring stations and identify the major contributing nutrient loads. The results showed that all samples could be analyzed using two main components, which accounted for 81.6% of the total variance. The PCA results showed that yields of orthophosphate (OP), silica (SI), nitrate–nitrites (NO 3 -NO 2 ), and total suspended sediment (TSS) are major contributors to nutrient yields. It also showed that land-planted crops, density of population, domestic and industrial discharges, and precipitation are fundamental causes of excess nutrient loads in MARB. These factors are of great significance for the excess nutrient load management and pollution control of the Mississippi River. It was found that the average nutrient yields were stable within the sub-MARB area, but the large nitrogen yields in the upper MARB and the large phosphorus yields in the lower MARB were of great concern. t-distributed stochastic neighbor embedding (t-SNE) revealed interesting nonlinear and local structures in nutrient yield distributions. Clustering analysis (CA) showed the detailed development of similarities in the nutrient yield distribution. Moreover, PCA, t-SNE, and CA showed consistent clustering results. This study demonstrated that the integration of dimension reduction techniques, PCA, and t-SNE with CA techniques in machine learning are effective tools for the visualization of the structures of the correlations in high-dimensional datasets of nutrient yields and provide a comprehensive understanding of the correlations in the distributions of nutrient loads across the MARB.

54 ENVIRONMENTAL SCIENCES↗

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: A. identifying options for the control parameters*

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter-erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding. This part A of the present study reports new results for largely the same ITER cases, confirming the strong correlations reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne [Ne/s], and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In the companion report, part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction 2 point modelling, Rev2PM. The input to the reduced model is a value of the variable pair (T et @q ⟂,pk ,Inj Ne ) and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , n e,Xpt (the electron density at the poloidal location of the X-point), etc. In part B the reduced model is quantitatively characterized using one half of the code cases; it is then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half of the cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: B. A reduced model based on reversed-direction two point modeling

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter–erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding (Pitts et al 2019). Part A of the present study reports new results for largely the same ITER cases, confirming the strong correlation reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not as yet been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne (Ne s –1 ), and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In this part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction two point modeling, Rev2PM. The input to the reduced model is a value of the variable pair (T e,t @q ⊥,pk , Inj Ne )for a chosen case and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , the electron density at the X-point, n e,Xpt , etc. The reduced model was quantitatively characterized using one half of the code cases; it was then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Multiagent Resource Sharing Algorithm for Control of Advanced Energy Systems

This paper implements a novel resource sharing control strategy on a fuel cell–gas turbine hybrid power system at the National Energy Technology Laboratory’s Hybrid Performance Facility (Hyper). In a fuel cell–gas turbine hybrid power system, the simultaneous interaction of the gas turbine and the fuel cell creates a tightly coupled environment characterized by conflicting dynamics. In this paper, a model-free control approach is applied to solve the tightly coupled control problem posed by this challenging environment. Specifically, this control problem is presented as a resource sharing problem that can be solved using a resource sharing algorithm that is defined based on the distribution construction concept. This algorithm creates computational agents and solves the problem through the distribution and redistribution of shared resources defined as blocks. Furthermore, two agents were created; the first agent (agent 1) controls the gas turbine speed by adjusting the electric load, and the second agent (agent 2) controls the cathode mass flow through the fuel cell using the cold-air bypass valve. A parametric study was performed over the course of 15 experimental tests for both agents 1 and 2 through an evaluation of the responses based on setpoint changes. The algorithm was shown to have behavior comparable to a previously implemented multi-input multioutput state-space controller, which was designed through a model-based control approach. The resource sharing algorithm was able to find stable performance during run-time operations without any prior system knowledge identification on the power plant and without creating models used in traditional control strategies.

25 ENERGY STORAGE↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Constrained power reference control for wind turbines

The cost of wind energy can be reduced by controlling the power reference of a turbine to increase energy capture, while maintaining load and generator speed constraints. We apply standard torque and pitch controllers to the direct inputs of the turbine and use their set points to change the power output and reduce generator speed and blade load transients. A power reference controller increases the power output when conditions are safe and decreases it when problematic transient events are expected. Transient generator speeds and blade loads are estimated using a gust measure derived from a wind speed estimate. A hybrid controller decreases the power rating from a maximum allowable power. Compared to a baseline controller, with a constant power reference, the proposed controller results in generator speeds and blade loads that do not exceed the original limits, increases tower fore-aft damage equivalent loads by 1%, and increases the annual energy production by 5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Physicochemically‐Ordered Interphases for High‐Performance Composites

To enhance the mechanical properties of carbon fiber‐reinforced polymer composites, a physicochemical scaffold is designed incorporating microscopically architected chemically reactive nanofibers that act as a multiscale bridge between the carbon fibers and the matrix. Thermally activated nanofibers leverage their morphologically driven mechanochemical properties to form covalent bonds with adjacent polymer molecules, creating a co‐continuous network that dramatically enhances fiber‐matrix load transfer. By meticulously controlling the nanofiber architecture through variable surface area, functional group availability, and polymer chain alignment effects, the extent of covalent bonding between nanofibers and the matrix is manipulated ultimately resulting in improved carbon fiber‐matrix adhesion. Further, the concept was validated using polyacrylonitrile nanofibers within an acrylonitrile butadiene styrene matrix in a discontinuous carbon fiber‐reinforced composite system. Nanomechanical studies using atomic force microscopy and low‐field nuclear magnetic resonance spectroscopy confirmed immobilized, chemically transferred, and ordered nanostructures at the interphase. The resulting composites demonstrated ≈56% and ≈175% improvements in tensile strength and toughness, respectively, compared to composites without nanofiber. Comprehensive thermal, rheological, and X‐ray scattering analyses, along side all‐atomic molecular dynamics simulations, revealed the fundamental mechanisms behind these improvements in mechanical behavior. The versatility and efficacy of the approach have the potential to address longstanding interphase challenges in the composite industry.

36 MATERIALS SCIENCE↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗