NDE Software Developed at NASA Glenn Research Center

NASA Glenn Research Center has developed several important Nondestructive Evaluation (NDE) related software packages for different projects in the last 10 years. Three of the software packages have been created with commercial-grade user interfaces and are available to United States entities for download on the NASA Technology Transfer and Partnership Office server (https://sr.grc.nasa.gov/). This article provides brief overviews of the software packages.

image processing↗

Additive Manufacturing (AM) Activities and Non-Destructive Evaluation (NDE) at GSFC

NASA personnel will be meeting with a delegation from the Japan Aerospace Exploration Agency (JAXA) Office of Safety and Mission Assurance (OSMA) at Langley Research Center on 2217 through 3217. The purpose of the meeting is a technical interchange between NASA and JAXA to discuss Non-Destructive Evaluation (NDE) of Additive Manufacturing (AM) parts and the HALT process (relates to accelerated life testing). The visitors will be a small group of Japanese citizens. Goddard Space Flight Center (GSFC) has been asked to participate in the meeting, either in person or via teleconference. This presentation covers NDE efforts at GSFC and provides a cursory overview of AM and lab capabilities.

additive manufacturing↗

Investigation of Carbon Fiber Architecture in Braided Composites Using X-Ray CT Inspection

During the fabrication of braided carbon fiber composite materials, process variations occur which affect the fiber architecture. Quantitative measurements of local and global fiber architecture variations are needed to determine the potential effect of process variations on mechanical properties of the cured composite. Although non-destructive inspection via X-ray CT imaging is a promising approach, difficulties in quantitative analysis of the data arise due to the similar densities of the material constituents. In an effort to gain more quantitative information about features related to fiber architecture, methods have been explored to improve the details that can be captured by X-ray CT imaging. Metal-coated fibers and thin veils are used as inserts to extract detailed information about fiber orientations and inter-ply behavior from X-ray CT images.

braided composites↗

Composite Bond Line Measurements Based on A Bayesian Analysis of Flash Thermography Data

For bonded composite materials, an accurate characterization of the adhesive bond line is needed to predict failure modes and fracture toughness. In this paper, bond line thickness was estimated from data obtained using through transmission flash thermography. The forward model that predicts back surface temperature is based on a three layer heat diffusion equation with varying diffusivity and flux boundary conditions. The corresponding inverse problem of estimating bond line thickness from measurement data was solved using a Bayesian approach that assumed Gaussian priors for the bond line thickness and thermal diffusivity of the adherends. Finally, the outputs of the thermography based method were compared to measurements that were collected using a micrometer and ultrasound testing.

Flash thermography↗

Composite Bond Line Measurements Based on a Bayesian Analysis of Flash Thermography Data

For bonded composite materials, an accurate characterization of the adhesive bond line is needed to predict failure modes and fracture toughness. In this paper, bond line thickness was estimated from data obtained using through transmission flash thermography. The forward model that predicts back surface temperature is based on a three layer heat diffusion equation with varying diffusivity and flux boundary conditions. The corresponding inverse problem of estimating bond line thickness from measurement data was solved using a Bayesian approach that assumed Gaussian priors for the bond line thickness and thermal diffusivity of the adherends. Finally, the outputs of the thermography based method were compared to measurements that were collected using a micrometer and ultrasound testing.

Flash thermography↗

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using Ti-6AL-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation.

additive manufacturing↗

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using a Ti-6Al-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation. Small keyhole pores buried deep were not detectable with this technique, however, some larger subsurface elongated pores along with some open surface pores did show some promise for detectability.

additive manufacturing↗

Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) Overview

Future lunar surface missions require construction materials that can be manufactured in situ using lo-cal resources while operating under extreme environmental conditions. Many Lunar material demands can be solved solely with regolith by compacting or sintering. And yet past Lunar missions rely on polymeric materials, and sustained Lunar missions must reduce Earth-supplied polymers dependence. Dual-cure (Ultraviolet (UV) and thermal) polymer-regolith composites offer a promising pathway by leveraging solar UV radiation, moderate thermal in-put, and regolith. Mission mass limits, power availability and energy constraints on the lunar surface further motivate low-energy processing and curing strategies for surface construction materials. The Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) project has successfully synthesized and demonstrated dual-cure photopolymer resins derivable from in-situ resources [3]. Morphological, thermal, and mechanical characterization show that the newly formulated UV curable resin systems integrates well with lunar regolith simulants. Processing and chemistry changes, and computational analysis advanced the composite design. X-ray CT scanned and computational analysis demonstrate that resin, regolith and additives are well incorporated. The large fraction of regolith, 95% by mass, large char yield (82% mass), low thermal conductivity (0.26 W/m/K), confirm this material as a promising high-performance thermal and structural material.

thermal conductivity↗

A national center for biocomputation: in search of a patient-specific interactive virtual surgery workbench

This report describes the three-dimensional imaging and virtual environment technologies developed in NASA's Biocomputation Center for scientific purposes that have now led to applications in the field of medicine. A major goal is to develop a virtual environment surgery workbench for planning complex craniofacial and breast reconstructive surgery, and for training surgeons.

NASA Discipline Neuroscience↗

From Tomography to Material Properties of Thermal Protection Systems

The X-ray micro-tomography technique provides non-destructive characterizations of three-dimensional material micro-structures at spatial resolutions from the sub-micron to the centimeter scale. High quality micro-tomography images of NASA Thermal Protection System (TPS) materials are obtained using one of the brightest synchrotron X-ray sources available. Leveraging on NASA supercomputing capabilities, material properties and response are computed from tomography-data. This talk highlights the process and challenges of going from 3D images of actual material structures to simulations of properties and phenomena relevant to TPS material response, such as thermal conductivity, permeability, mass transport and high temperature reactions. The talk is addressed to a broad audience including scientists, engineers, researchers, educators, programmers, managers, and members of the media.

tomography↗

Logical Shadow Tomography: Efficient Estimation of Error-mitigated Observables

In near-term quantum applications, reducing errors and improving device reliability is an essential task. Towards these ends, various techniques have been introduced in recent literature, collectively referred to as quantum error mitigation techniques, for reducing errors in pre-fault-tolerant devices. Here, we introduce logical shadow tomography as a versatile error mitigation method. Our technique uses a stabilizer code to encode information in a logical state. Instead of doing active error correction, quantum states will be measured at the end of computation via shadow tomography and non-logical errors are projected out in the classical post-processing. Relative to quantum subspace expansion which requires O(2(M-1)L) experiments to estimate an logical Pauli observable encoded by an [[M, L, d]] code, our technique only requires 2L experiments, an important practical reduction in resources.

Hong-Ye Hu↗

Database tomography for commercial application

Database tomography is a method for extracting themes and their relationships from text. The algorithms, employed begin with word frequency and word proximity analysis and build upon these results. When the word 'database' is used, think of medical or police records, patents, journals, or papers, etc. (any text information that can be computer stored). Database tomography features a full text, user interactive technique enabling the user to identify areas of interest, establish relationships, and map trends for a deeper understanding of an area of interest. Database tomography concepts and applications have been reported in journals and presented at conferences. One important feature of the database tomography algorithm is that it can be used on a database of any size, and will facilitate the users ability to understand the volume of content therein. While employing the process to identify research opportunities it became obvious that this promising technology has potential applications for business, science, engineering, law, and academe. Examples include evaluating marketing trends, strategies, relationships and associations. Also, the database tomography process would be a powerful component in the area of competitive intelligence, national security intelligence and patent analysis. User interests and involvement cannot be overemphasized.

Kostoff, Ronald N.↗

Analysis of Fibrous Felts for Flexible Ablators Using Synchrotron Hard X-Ray Micro-Tomography

We analyzed the material properties of low-density felts that are used as substrates for new-generation flexible and conformal carbon/phenolic ablators, and compared them with those of a rigid carbon fiber preform that is used to manufacture rigid carbon/phenolic ablators. Micro-tomography measurements were obtained using synchrotron X-rays, allowing the characterization of the materials microstructure at the scale of the fibers. Using the tomography voxels as computational grids, we computed tortuosity and room temperature conductivity. In addition we performed micro-scale simulations of the oxidation of carbon fibers using a random walk model for oxygen diffusion and a probability law to model surface reactions.

Ablation↗

New approaches to virtual environment surgery

This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.

NASA Discipline Neuroscience↗