Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “completely positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Burning Rate Emulator (BRE) for Study in Microgravity

A gas-fueled burner, the Burning Rate Emulator (BRE), is used to emulate condensed-phase fuel flames. The design has been validated to easily measure the burning behavior of condensed-phase fuels by igniting a controlled stream of gas fuel and diluent. Four properties, including the heat of combustion, the heat of gasification, the surface temperature, and the laminar smoke point, are assumed to be sufficient to define the steady burning rate of a condensed-phase fuel. The heat of gasification of the fuel is determined by measuring the heat flux and the fuel flow rate. Microgravity BRE tests in the NASA 5.2 s drop facility have examined the burning of pure methane and ethylene (pure and 50 in N2 balance). Fuel flow rates, chamber oxygen concentration and initial pressure have been varied. Two burner sizes, 25 and 50 mm respectively, are chosen to examine the nature of initial microgravity burning. The tests reveal bubble-like flames that increase within the 5.2s drop but the heat flux received from the flame appears to asymptotically approach steady state. Portions of the methane flames appear to locally detach and extinguish at center, while its shape remains fixed, but growing. The effective heat of gasification is computed from the final measured net heat flux and the fuel flow rate under the assumption of an achieved steady burning. Heat flux (or mass flux) and flame position are compared with stagnant layer burning theory. The analysis offers the prospect of more complete findings from future longer duration ISS experiments.

diffusion flames↗

Controls-structures-interaction dynamics during RCS control of the Orbiter/SRMS/SSF configuration

During the assembly flights of the Space Station Freedom (SSF), the Orbiter will either dock with the SSF and retract to the final berthed position, or will grapple the SSF using the Shuttle Remote Manipulator System (SRMS) and maneuver the SRMS coupled vehicles to their final berthed position. The SRMS method is expected to take approximately one to one and a half hours to complete and require periodic attitude corrections by either the Orbiter or the SSF reaction control system (RCS) or continuous control by a control moment gyro (CMG) system with RCS desaturation as required. Free drift of the attached vehicles is not currently thought to be acceptable because the desired system attitude will quickly deteriorate due to unbalanced gravity gradient and aerodynamic torques resulting in power generation problems, thermodynamic control problems, and communications problems. This paper deals with the simulation and control of the SRMS during trunnion/latch interaction dynamics and during RCS maneuvers. The SRMS servo drive joints have highly non-linear elastic characteristics which tend to degrade sensitive control strategies. In addition the system natural frequencies are extremely low and depend on the drive joint deflections and SRMS geometric position. The lowest mean period of oscillation for the Orbiter/SRMS/SSF(MB6) system in brakes hold mode positioned near the final berthed position is approximately 120 seconds. A detailed finite element model of the SRMS has been developed and used in a newly developed SRMS systems dynamics simulation to investigate the non-linear transient response dynamics of the Orbiter/SRMS/SSF systems. The present SRMS control strategy of brakes only recommended by the Charles Draper Labs is contrasted with a robust controller developed by the authors. The robust controller uses an optimal inear quadratic regulator (LQR) to optimally place the closed-loop poles of a multivariable continuous-time system within the common region of an open sector with the sector angle plus or minus 45 degrees from the negative real axis, and the left-hand side of a parallel to the imaginary axis in the complex s-plane. This guarantees that the critical damping ratio for the desired control modes is equal to or in excess of 0.707. The matrix sign function is used for solving the Riccati equations which appear in the controller design procedure. Fast and stable algorithms have recently been developed for the computation of the matrix sign function. Simulation results are given which demonstrate the potential CSI involvement for the current SRMS control system and the proposed control system.

Schliesing, J. A.↗

New advances in the partial-reflection-drifts experiment using microprocessors

Improvements to the partial reflection drifts experiment are completed. The results of the improvements include real time processing and simultaneous measurements of the D region with coherent scatter. Preliminary results indicate a positive correlation between drift velocities calculated by both methods during a two day interval. The possibility now exists for extended observations between partial reflection and coherent scatter. In addition, preliminary measurements could be performed between partial reflection and meteor radar to complete a comparison of methods used to determine velocities in the D region.

Ruggerio, R. L.↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

Assessment of Prone Positioning of Restrained, Seated Crewmembers in a Post Landing Stable 2 Orion Configuration

During the Orion landing and recovery subsystem design review, June 2009, it was noted that the human system and various vehicle systems, the environmental control and life support (ECLSS) and guidance, navigation and control (GN&C) systems for example, are negatively affected by Orion assuming a stable 2 (upside down; Figure A) configuration post landing. The stable 2 configuration is predicted to occur about 50% of the time based on Apollo landing data and modeling of the current capsule. The stable 2 configuration will be countered by an active up-righting system (crew module up-righting system; CMUS). Post landing balloons will deploy and inflate causing the vehicle to assume or maintain the stable 1 (up-right; Figure B) configuration. During the design review it was proposed that the up-righting system could be capable of righting the vehicle within 60 seconds. However, this time limit posed a series of constraints on the design which made it less robust than desired. The landing and recovery subsystem team requested an analysis of Orion vehicle systems as well as the human system with regard to the effect of stable 2 in order to determine if an up-righting response time greater than 60 seconds could be tolerated. The following report focuses on the assessment of the human system in the posture assumed when Orion is in the stable 2 configuration. Stable 2 will place suited, seated, and restrained crewmembers in a prone (facedown), head-up position for a period of time dependent on the functionality of the up-righting systems, ability of the crew to release themselves from the seat and restraints, and/or time to arrival of rescue forces. Given that the Orion seat and restraint system design is not complete and therefore, not available for evaluation, Space Medicine assessed how long a healthy but deconditioned crewmember could stay in this prone, restrained position and the physiological consequences of this posture by researching terrestrial analogs and considered the known physiological alterations and deconditioning experienced by long duration crewmembers.

Barr, Yael↗

Overview of the LaNCETS Flight Experiment and CFD Analysis. Supplemental Movies

This presentation focuses on nearfield airborne pressure signatures from the Lift and Nozzle Change Effect on Tail Shocks (LaNCETS) flight test experiment. The primary motivation for nearfield probing in the supersonic regime is to measure the shock structure of aircraft in an ongoing effort to overcome the overland sonic boom barrier for commercial supersonic transportation. LaNCETS provides the opportunity to investigate lift distribution and engine plume effects. During Phase 1 flight testing an F-15B was used to probe the F-15 LaNCETS aircraft in order to validate CFD and pre-flight prediction tools. A total of 29 probings were taken at 40,000 ft. altitude at Machs 1.2, 1.4 and 1.6. LaNCETS Phase 1 flight data are presented as a detailed pressure signature superimposed over a picture of the LaNCETS aircraft. The attenuation of the Inlet-Canard shocks with distance as well as its forward propagation and the coalescence of the noseboom shock are illustrated. A detailed CFD study on a simplified LaNCETS aircraft jet nozzle was performed providing the ability to more accurately capture the shocks from the propulsion system and emphasizing how under- and over-expanding the nozzle affects the existence of shock trains inside the jet plume. With Phase 1 being a success preparations are being made to move forward to Phase 2. Phase 2 will fly similar flight conditions, but this time changing the aircraft's lift distribution by biasing the canard positions, and changing the plume shape by under- and over-expanding the nozzle. Nearfield probing will again be completed in the same manner as in Phase 1. An additional presentation focuses on LaNCETS CFD solution methodology. Discussions highlight grid preprocessing, grid shearing and stretching, flow solving and contour plots. Efforts are underway to better capture the flow features via grid modification and flow solution methodology, which will help to achieve better agreement with flight data. An included CD-ROM provides animations of the nearfield probing procedure and of real data from one of the probings integrated with GPS positional and velocity data. An additional in-flight video from the rear seat of the probing aircraft is also provided.

Cliatt, Larry J., II↗

Polarization Type Potential Induced Degradation under Positive Bias in a Commercial PERC Module: Preprint

Potential induced degradation of the polarization type (PID-p) can reduce module performance in a relatively short period of time. PID-p can occur at both voltage polarities, but most studies are focused on degradation under a negative bias. This paper uses commercial bifacial passivated emitter and rear contact (PERC) cells within a monofacial glass-backsheet module construction to evaluate the impact of PID-p under a positive bias on the front side. Using the aluminum-foil (Al-foil) method, the module was stressed for PID in an environmental chamber. After the stress, the maximum power (Pmax) showed a decline of 3.1% at 1000 W/m2 and 6.2% at 200 W/m2. Recovery under light was also investigated. Complete recovery was observed at high irradiance, while a partial recovery was seen at lower irradiance. The outcomes of this study can help in understanding PID-p degradation under a positive bias and its recovery under the light.

PERC↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗

Auroral vector electric field and particle comparisons. 1: Pre-midnight convection topology

Polar 3 was launched in northern Norway on January 27, 1974. Traversing nearly 3 deg latitude, the rocket crossed over a stable IBC II auroral arc in the positive bay region and continued north to a convection boundary which was identified as the Harang discontinuity. Measurement of the complete electric field vector, of energetic electrons and of the auroral N+2 and OI emissions were used to study the convection topology in the pre-magnetic-midnight region. A strong anticorrelation was observed between the electric field and the precipitating energetic electrons. The inverted V nature of the electron precipitations at the convection boundary, compared with the lack of such structure over the arc which was within the positive bay region, leads to the conclusion that auroral arcs are likely to be associated with inverted V type precipitation only at or poleward of convection boundaries and their eddy structures.

Maynard, N. C.↗

Restoration of plasma volume after 16 days of head-down tilt induced by a single bout of maximal exercise

Seven healthy men performed maximal exercise 24 h before the end of 16 days exposure to 6 degrees head-down tilt (HDT) to test the hypothesis that such an exercise technique could restore plasma volume (PV) at the end of a simulated space mission. Exercise consisted of supine cycling with graded work rates increasing by 16 W/min to volitional fatigue and required an average of 16 min. The experimental protocol was a standard cross-over design in which the order of treatment (exercise or control) was counterbalanced across all seven subjects. PV, fluid intake (ad libitum), urine output, renal function, and hormones associated with fluid homeostasis were measured before HDT, 24 h before the end of HDT just prior to exercise, and at the end of HDT 24 h after exercise. HDT reduced PV by 16% in both control and exercise conditions. Maximal exercise completely restored plasma volume within 24 h to 3.9 +/- 3.2% of pre-HDT levels despite continued HDT. Compared with control, exercise induced a 660-ml larger positive fluid balance because of greater fluid intake and reduced urine volume during the 24 h after exercise. These results suggest that one bout of maximal leg exercise before return from 16 days of spaceflight may be completely effective in stimulating thirst and restoring plasma volume to preflight levels.

Non-NASA Center↗

PEM regenerative fuel cells

This paper will update the progress in developing electrocatalyst systems and electrode structures primarily for the positive electrode of single-unit solid polymer proton exchange membrane (PEM) regenerative fuel cells. The work was done with DuPont Nafion 117 in complete fuel cells (40 sq cm electrodes). The cells were operated alternately in fuel cell mode and electrolysis mode at 80 C. In fuel cell mode, humidified hydrogen and oxygen were supplied at 207 kPa (30 psi); in electrolysis mode, water was pumped over the positive electrode and the gases were evolved at ambient pressure. Cycling data will be presented for Pt-Ir catalysts and limited bifunctional data will be presented for Pt, Ir, Ru, Rh, and Na(x)Pt3O4 catalysts as well as for electrode structure variations.

Swette, Larry L.↗

Photointerpretation of Skylab 2 multispectral camera (S-190A) data: Advance report of significant results

The author has identified the following significant results. A significant and possible major economic example of the practical value of Skylab photographs was provided by locating on Skylab Camera Station Number 4, frame 010, SL-2, an area of exposures of limestone rocks which were thought to be completely covered by volcanic rocks based upon prior mapping. The area is located less than 12 miles north of the Ruth porphyry copper deposit, White Pine County, Nevada. This is a major copper producing open pit mine owned by Kennecott Copper Corporation. Geophysical maps consisting of gravity and aeromagnetic studies have been published indicating three large positive magnetic anomalies located at the Ruth ore deposits, the Ward Mountain, not a mineralized area, and in the area previously thought to be completely covered by post-ore volcanics. Skylab photos indicate, however, that erosion has removed volcanic cover in specific sites sufficient to expose the underlying older rocks suggesting, therefore, that the volcanic rocks may not be the cause of the aeromagnetic anomaly. Field studies have verified the initial interpretations made from the Skylab photos. The potential significance of this study is that the large positive aeromagnetic anomaly suggests the presence of cooled and solidified magma below the anomalies, in which ore-bearing solutions may have been derived forming possible large ore deposits.

Jensen, M. L.↗

Liquid Hydrogen Propellant Tank Sub-Surface Pressurization with Gaseous Helium

A series of tests were conducted to evaluate the performance of a propellant tank pressurization system with the pressurant diffuser intentionally submerged beneath the surface of the liquid. Propellant tanks and pressurization systems are typically designed with the diffuser positioned to apply pressurant gas directly into the tank ullage space when the liquid propellant is settled. Space vehicles, and potentially propellant depots, may need to conduct tank pressurization operations in micro‐gravity environments where the exact location of the liquid relative to the diffuser is not well understood. If the diffuser is positioned to supply pressurant gas directly to the tank ullage space when the propellant is settled, then it may become partially or completely submerged when the liquid becomes unsettled in a microgravity environment. In such case, the pressurization system performance will be adversely affected requiring additional pressurant mass and longer pressurization times. This series of tests compares and evaluates pressurization system performance using the conventional method of supplying pressurant gas directly to the propellant tank ullage, and then supplying pressurant gas beneath the liquid surface. The pressurization tests were conducted on the Engineering Development Unit (EDU) located at Test Stand 300 at NASA Marshall Space Flight Center (MSFC). EDU is a ground based Cryogenic Fluid Management (CFM) test article supported by Glenn Research Center (GRC) and MSFC. A 150 ft3 propellant tank was filled with liquid hydrogen (LH2). The pressurization system used regulated ambient helium (GHe) as a pressurant, a variable position valve to maintain flow rate, and two identical independent pressurant diffusers. The ullage diffuser was located in the forward end of the tank and was completely exposed to the tank ullage. The submerged diffuser was located in the aft end of the tank and was completely submerged when the tank liquid level was 10% or greater. The ullage diffuser tests were conducted as a baseline to evaluate the performance of the pressurization system, and the submerged diffuser tests showed how the performance of the pressurization system was compromised when the diffuser was submerged in LH2. The test results are evaluated and compared, and included in this report for various propellant tank fill levels.

Stephens, J. R.↗

Thermal conductivity of salvaged fused cast alumina used in the glass industry

Fused cast alumina (FCA) has been and continues to be used as a refractory material in energy intensive industries such as glass melting and chemical processing. In-service degradation due to high temperature exposure in harsh environment affects the designed furnace thermal profiles and energy consumption. Phase transformation may occur at the refractory hot face during glass melting altering the properties. Three FCA blocks recovered from industrial furnaces were investigated in this study. The as-received FCA consists primarily of a mixture of alpha (α) and beta (β) alumina that has a thermal conductivity value of 5–6 W/mK. The Hot Disk method was used to obtain thermal conductivity directly on the refractory blocks. At the hot face, a transformation from β to α alumina occurred and was confirmed by an X-ray diffraction study. Thermal conductivity measurements as a function of position also showed a clear transition from β to α alumina at both ends of a complete block with no voids. Thermal conductivity of the α alumina tripled compared to β alumina. This study provides important information of heat transfer and thermal conductivity evolution to refractory manufacturers and users.

36 MATERIALS SCIENCE↗

Temperature-dependent Mg, Fe distribution in a lunar olivine.

The nuclear hyperfine doublets of Fe-57 at the two nonequivalent octahedrally coordinated positions M1 and M2 in an olivine from lunar basalt 12018 have been analyzed in the temperature range between 250 and 450 C. The Mg(2+), Fe(2+) is somewhat ordered, the Fe(2+) occupancy being greater at one of the two M positions by approximately 20%. After heating at 1155 C for seven days, the distribution was almost completely disordered. Studies of natural and heated olivines from terrestrial rocks show that the Mg(2+), Fe(2+) exchange reaction in olivines is considerably more sluggish than in chain silicates. Generally no change in site occupancy can be observed after heating at temperatures of approximately 900 C over several days. The observed degree of ordering in the lunar olivine is indicative of slow cooling during crystallization.

Virgo, D.↗

NASA-JSC antenna near-field measurement system

Work was completed on the near-field range control software. The capabilities of the data processing software were expanded with the addition of probe compensation. In addition, the user can process the measured data from the same computer terminal used for range control. The design of the laser metrology system was completed. It provides precise measruement of probe location during near-field measurements as well as position data for control of the translation beam and probe cart. A near-field range measurement system was designed, fabricated, and tested.

Cooke, W. P.↗

Wind-tunnel Investigation of Ground Effect on Wings with Flaps

An investigation was conducted in the N.A.C.A. 7- by 10-foot wind tunnel to determine the effect of ground proximity on the aerodynamic characteristics of wings equipped with high-lift devices. A rectangular and a tapered wing were tested without flaps, with a split flap, and with a slotted flap. The ground was represented by a flat plate, completely spanning the tunnel and extending a considerable distance ahead and back of the model. The position of the plate was varied from one-half to three chord lengths below the wing. The results are presented in the form of curves of absolute coefficients, showing the effect of the ground on each wing arrangement. The effect of the ground on lift, drag, and pitching moment is discussed. An appendix gives equations for calculating tunnel-wall corrections to be applied to ground-effect tests conducted in rectangular tunnels when a plate is used to represent the ground. The tests indicated that the ground effect on wings with flaps is a marked decrease in drag, a decrease in diving moment, and a substantial reduction in maximum lift.

Recant, Isidore G↗