Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “chip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

ChIP-seq Mapping of Distant-Acting Enhancers and Their In Vivo Activities

The genomic location and function of most distant-acting transcriptional enhancers in the human genome remains unknown We performed ChIP-seq for various transcriptional coactivator proteins (such as p300) directly from different embryonic mouse tissues, identifying thousands of binding sitesTransgenic mouse experiments show that p300 and other co-activator peaks are highly predictive of genomic location AND tissue-specific activity patterns of distant-acting enhancersMost enhancers are active only in one or very few tissues Genomic location of tissue-specific p300 peaks correlates with tissue-specific expression of nearby genes Most binding sites are conserved, but the global degree of conservation varies between tissues

59 BASIC BIOLOGICAL SCIENCES↗

Parameter Determination of the Non-Local Granular Fluidity Model for Wood Chips by Comparison to Well-Defined Experimental Flow Systems

Unlike simple liquids and gases, the bulk flow and transport of granular materials remain poorly understood by physicists and pose many problems for engineers in designing and operating bulk-solids handling equipment. Discrete element methods (DEM) are currently considered the state-of-the-art for simulating the flow of granular materials, but DEM is limited in system size to about a few million particles due to high computational costs, even when run on current high-performance computing architectures. Continuum models are needed to simulate the flows of bulk solids in industrial-scale vessels and equipment, e.g., grain silos and coal-ash disposal piles. The focus of this work is the so-called nonlocal granular fluidity (NLGF) model that has been previously shown to reproduce observed nonlocal behaviors that arise when granular phenomena occur on length scales that are near the scale of the system geometry, e.g., the jamming of hopper outlets and the stop-height of piles on inclines [PNAS, 110(17), 6730-6735]. We have implemented the NLGF constitutive model in OpenFOAM CFD software, performed simulations of well-defined flow systems, and compared the results to experimental data. Experimental systems include a ring-shear tester, pile formation, flow on an incline, and discharge of a hopper. The tested material was loblolly pine wood chips that were milled and sieved to a size range of roughly 0.05-0.25 inches in diameter. The NLGF model parameters were tuned to achieve reasonable agreement between simulation and experimental results. Further, we evaluate the mapping between measurable material properties (bulk friction angle, particle-particle friction, compressibility, grain diameter, etc.) with NLGF model parameters, some of which have direct analogs (friction parameters and grain diameter) while others are constructs of the model (nonlocal amplitude and timescale of fluidity evolution).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fully automated Liquid Extraction-Based Surface Sampling and Ionization Using a Chip-Based Robotic Nanoelectrospray Platform

A fully automated liquid extraction-based surface sampling device utilizing an Advion NanoMate chip-based infusion nanoelectrospray ionization system is reported. Analyses were enabled for discrete spot sampling by using the Advanced User Interface of the current commercial control software. This software interface provided the parameter control necessary for the NanoMate robotic pipettor to both form and withdraw a liquid microjunction for sampling from a surface. The system was tested with three types of analytically important sample surface types, viz., spotted sample arrays on a MALDI plate, dried blood spots on paper, and whole-body thin tissue sections from drug dosed mice. The qualitative and quantitative data were consistent with previous studies employing other liquid extraction-based surface sampling techniques. The successful analyses performed here utilized the hardware and software elements already present in the NanoMate system developed to handle and analyze liquid samples. Implementation of an appropriate sample (surface) holder, a solvent reservoir, faster movement of the robotic arm, finer control over solvent flow rate when dispensing and retrieving the solution at the surface, and the ability to select any location on a surface to sample from would improve the analytical performance and utility of the platform.

Kertesz, Vilmos↗

Utilizing the Inherent Electrolysis in a Chip-Based Nanoelectrospray Emitter System to Facilitate Selective Ionization and Mass Spectrometric Analysis of Metallo Alkylporphyrins

A commercially available chip-based infusion nanoelectrospray ionization system was used to ionize metallo alkylporphyrins for mass spectrometric detection and structure elucidation by mass spectrometry. Different ionic forms of model compounds (nickel (II), vanadyl (II), copper (II) and cobalt (II) octaethylporphyrin) were created by using two different types of conductive pipette tips supplied with the device. These pipette tips provide the conductive contact to solution at which the electrolysis process inherent to electrospray takes places in the device. The original unmodified, bare carbon-impregnated plastic pipette tips, were exploited to intentionally electrochemically oxidize (ionize) the porphyrins to form molecular radical cations for detection. Use of modified pipette tips, with a surface coating devised to inhibit analyte mass transport to the surface, was shown to limit the ionic species observed in the mass spectra of these porphyrins largely, but not exclusively, to the protonated molecule. Under the conditions of these experiments, the effective upper potential limit for oxidation with the uncoated pipette tip was 1.1 V or less and the coated pipette tips effectively prevented the oxidation of analytes with redox potentials greater than about 0.25 V. Product ion spectra of either molecular ionic species could be used to determine the alkyl chain length on the porphyrin macrocycle. The utility of this electrochemical ionization approach for the analysis of naturally occurring samples was demonstrated using nickel geoporphyrin fractions isolated from Gilsonite bitumen. Acquiring neutral loss spectra as a means to improve the specificity of detection in these complex natural samples was also illustrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. Here, we present the noise performance of a full R similar to 275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of similar to 3x10 -16 W Hz -1/2 at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020.

47 OTHER INSTRUMENTATION↗

Advanced Manufacturing of Printed Melt Wire Chips for Cheap, Compact Passive In-Pile Temperature Sensors

Melt wires are a passive sensor used to determine peak temperatures during a test. Traditional melt wires are commonly used in test reactor experiments such as in the Advanced Test Reactor (ATR). However, the conditions within a reactor present significant challenges towards test design due to space limitations and the harsh environment. For example, some test capsules have only a couple millimeters in diameter available for instrumentation, which is too small to accommodate a traditional melt wire package, and they are ultimately filled to capacity when they are immersed in molten metal. To enable instrumentation for space limited applications, peak temperature sensing capabilities paired with additive manufacturing options have been utilized to develop printed melt wires for peak irradiation temperature detection. Here, we report on the fabrication of miniaturized melt wire chips with a melting temperature ~960 °C with printed silver nanoparticle ink. This study will advance the development of unique temperature sensors capable of sensing user specified temperature ranges within the harsh environment of irradiation testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes

A polyimide microfluidic chip with a microhole emitter (Ø 10–12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cell laden hydrogel construct on-a-chip for mimicry of cardiac tissue in-vitro study

Since the leading cause of death are cardiac diseases, engineered heart tissue (EHT) is one of the most appealing topics defined in tissue engineering and regenerative medicine fields. The importance of EHT is not only for heart regeneration but also for in vitro developing of cardiology. Cardiomyocytes could grow and commit more naturally in their microenvironment rather than traditional cultivation. Thus, this research tried to develop a set up on-a-chip to produce EHT based on chitosan hydrogel. Micro-bioreactor was hydrodynamically designed and simulated by COMSOL and produced via soft lithography process. Chitosan hydrogel was also prepared, adjusted, and assessed by XRD, FTIR and also its degradation rate and swelling ratio were determined. Finally, hydrogels in which mice cardiac progenitor cells (CPC) were loaded were injected into the micro-device chambers and cultured. Each EHT in every chamber was evaluated separately. Prepared EHTs showed promising results that expanded in them CPCs and work as an integrated syncytium. High cell density culture was the main accomplishment of this study. - Highlights: • An engineered heart tissue in its microenvironment at a perfused micro-bioreactor is proposed. • Cell proliferation of cardiac cells in high cell density is achievable in setup while sacrificing hydrogel is degrading. • 16 distinct heart tissue constructs in each run reduce the time and cost and increase the test results accuracy.

60 APPLIED LIFE SCIENCES↗

Development of a highly specific HER2 monoclonal antibody for immunohistochemistry using protein microarray chips

HER2 is an orphan receptor tyrosine kinase of the EGFR families and is considered to be a key tumor driver gene [1]. Breast cancer and gastric cancer with HER2 amplification can be effectively treated by its neutralizing antibody, Herceptin. In clinic, Immunohistochemistry (IHC) was used as the primary screening method to diagnose HER2 amplification [2]. However, recent evidence suggested that the frequently used rabbit HER2 antibody 4B5 cross reacted with another family member HER4 [3]. IHC staining with 4B5 also indicated that there was strong non-specific cytoplasmic and nuclear signals in normal gastric mucosal cells and some gastric cancer samples. Using a protein lysate array which covers 85% of the human proteome, we have confirmed that the 4B5 bound to HER4 and a nuclear protein ZSCAN18 besides HER2. The non-specific binding accounts for the unexpected cytoplasmic and nuclear staining of 4B5 of normal gastric epithelium. Finally, we have developed a novel mouse HER2 monoclonal antibody UMAB36 with similar sensitivity to 4B5 but only reacted to HER2 across the 17,000 proteins on the protein chip. In 129 breast cancer and 158 gastric cancer samples, UMAB36 showed 100% sensitivity and specificity comparing to the HER2 FISH reference results with no unspecific staining in the gastric mucosa layer. Therefore, UMAB36 could provide as an alternative highly specific IHC reagent for testing HER2 amplification in gastric cancer populations. - Highlights: • HER2 antibody 4B5 cross-interacts with HER4 and ZSCAN18, which would interfere with the accuracy of IHC diagnosis of HER2. • A HER2 antibody UMAB36 has been developed with high sensitivity and specificity and can be utilized in HER2 diagnosis. • Protein lysate array is a novel strategy to screen for highly specific antibody.

60 APPLIED LIFE SCIENCES↗

Biomass, spacing and planting design influence cut-and-chip harvesting in hybrid poplar

Hybrid poplar is a woody crop grown for the production of bioenergy, biofuels and bioproducts. Harvesting is often the largest single cost in the production system and the development and optimization of equipment is evolving. Here, the objective of this study was to evaluate the performance of a single-pass, cut-and-chip harvesting operation in commercial plantings that included four cultivars, two spacing treatments, and two coppice planting designs (dedicated, and interplanted with sawtimber). Approximately 15 h of harvesting using a New Holland 9080 forage harvester equipped with a purpose-built coppice header was monitored over four days. Stand biomass ranged between 34 and 78 Mg ha –1 of fresh biomass and effective material capacity (C m ) of the harvester ranged from 10 to 78 Mg h –1 of fresh biomass excluding headland activities. Tree spacing had a significant effect on C m but cultivar and planting design did not. The treatments did not have discernible effects on machine fuel consumption (mean 83 L h –1 ; σ 16.4) or crop-specific fuel consumption for fresh biomass (mean 1.34 L Mg –1 ; σ 0.31). Crop-specific fuel consumption was positively correlated with engine load, and negatively correlated with standing biomass; this result was statistically significant but negligible (<1%) in terms of liters of fuel used for each additional Mg ha –1 of stand biomass for engine loads ranging between 30% and 110%.

59 BASIC BIOLOGICAL SCIENCES↗

An assessment of the harvesting and fuel performance of a single-pass cut-and-chip harvester in commercial-scale short-rotation poplar crops as influenced by crop and weather conditions

There is a need for data on commercial-scale harvesting operations in hybrid poplar short rotation crops to better understand costs and logistics, especially for modeling large scale biorefineries. An investigation was conducted on the in-field performance of a single-pass cut-and-chip harvester operating in commercial fields for over 370 individual wagon loads representing a range of crop and field conditions. Mean material capacity peaked at 70 Mg h -1 in dry conditions in lower biomass (<60 Mg ha -1 ), but was only 28 Mg h -1 during wet conditions and often higher standing biomass. Wet ground conditions require the harvester to divert additional power to maintaining forward movement, which results in decreased material capacity and increased fuel consumption. Crops with higher standing biomass had taller trees that do not always feed as smoothly into the harvester, slowing forward progress and lowering material capacity. Mean crop specific fuel consumption, L of fuel per Mg of biomass processed, generally decreased as standing biomass increased. When standing biomass was above 40 Mg ha -1 mean crop specific fuel consumption (FCC) was 1.69 L Mg -1 in dry conditions and 3.98 L Mg -1 in wet conditions, but when standing biomass was below 40 Mg ha-1 FCC increased drastically (as high as 5 L Mg -1 ) because the harvester is putting more effort into forward speed instead of material processing. Developing relationships between material capacity and fuel consumption based on standing biomass and ground conditions at representative scales are essential for conducting environmental and economic analyses of these systems.

09 BIOMASS FUELS↗

The fabrication of nanoscale Bi 2 Te 3 /Sb 2 Te 3 multilayer thin film-based thermoelectric power chips

In this work, we report our method of fabricating nanoscale multilayered Bi 2 Te 3 /Sb 2 Te 3 thin film-based integrated thermoelectric devices, and detail the voltage and power produced by the device. The multilayered Bi 2 Te 3 /Sb 2 Te 3 thin film was grown via e-beam evaporation; it had 20 alternating Bi 2 Te 3 - and Sb 2 Te 3 -layers, each layer being 1.5 nm thick. We characterized the film using high-resolution transmission electron microscopy (HRTEM), revealing its excellent cross-sectional structure without any obvious interface defects. The Bi 2 Te 3 /Sb 2 Te 3 multilayer films were investigated by synchrotron x-ray scattering. An integrated device including 128×256 thermoelectric elements was fabricated from the multilayered film. An open-circuit voltage of 51 mV and a maximum power of 21 nW were produced from this 30 nm-thick Bi 2 Te 3 /Sb 2 Te 3 multilayer TE device. We found that the nanoscale multilayer structure significantly affects the voltage and power produced. Lastly, the fabrication of the integrated thermoelectric devices is compatible to that of generating standard integrated circuits (ICs), and is scalable for producing higher voltage and power, or achieving solid-state cooling for on-chip applications.

36 MATERIALS SCIENCE↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. Furthermore, the full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoelectromechanical Control of Spin–Photon Interfaces in a Hybrid Quantum System on Chip

Color centers (CCs) in nanostructured diamond are promising for optically linked quantum technologies. Scaling to useful applications motivates architectures meeting the following criteria: C1 individual optical addressing of spin qubits; C2 frequency tuning of spin-dependent optical transitions; C3 coherent spin control; C4 active photon routing; C5 scalable manufacturability; and C6 low on-chip power dissipation for cryogenic operations. Here, we introduce an architecture that simultaneously achieves C1–C6. We realize piezoelectric strain control of diamond waveguide-coupled tin vacancy centers with ultralow power dissipation necessary. The DC response of our device allows emitter transition tuning by over 20 GHz, combined with low-power AC control. We show acoustic spin resonance of integrated tin vacancy spins and estimate single-phonon coupling rates over 1 kHz in the resolved sideband regime. Combined with high-speed optical routing, our work opens a path to scalable single-qubit control with optically mediated entangling gates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Hybrid Molecular–Nanophotonic Platform for On-Chip Cavity Quantum Electrodynamics and Collective Interactions

We present a hybrid solid-state cavity quantum electrodynamics (QED) platform that integrates a high density of coherent organic molecules with high-quality-factor nanophotonics. Thin anthracene crystals doped with dibenzoterrylene (DBT) are mechanically transferred onto prefabricated silicon nitride photonic crystal cavities, preserving both the cavity quality and molecular coherence. This approach decouples emitter synthesis from nanofabrication, providing a pathway for integrating other types of emitters. The high density of molecular emitters results in up to ten molecules being coupled to a single cavity. By tuning pairs of molecules into resonance within a single cavity mode, we observe cavity-mediated interactions in both dispersive and dissipative regimes. Furthermore, these results establish an accessible route to deterministic on-chip single- and multiphoton sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗