Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “casing integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Finite-element-based simulations of electrodes for CO 2 cascade reduction reactions

The multielectron reduction of CO 2 to liquid fuels could be a path to scalable energy storage, but reaching this goal requires major advances in catalysis and systems engineering. Cascade catalysis, which couples sequential reactions without isolating intermediates, has emerged as a promising route to enhance selectivity and efficiency in CO 2 reduction (CO 2 R). In this review, we examine how finite-element-based simulations of continuum model [finite element method (FEM)] approaches are being used to analyze and guide CO 2 R cascade systems. We first outline the fundamentals of cascade catalysis and recent advances in catalytic materials (metallic, molecular, and hybrid architectures). We then focus on FEM developments at the electrode and device scales, emphasizing how these models capture transport phenomena, local microenvironments, and geometry-dependent effects. To clarify design principles, we present case studies of cascade electrodes organized in systems without and with integrated semiconductors. We further emphasize the integration of FEM with multiscale frameworks (density functional theory, molecular dynamics, kinetic Monte Carlo) and its role in bridging atomic-level insights with device-level performance. Finally, we identify current limitations and future prospects, including improved boundary conditions, coupling with operando experiments, and machine learning-accelerated model development. Together, these insights provide design principles for next-generation CO 2 R cascade systems for efficient solar fuel production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CFD Evaluation of Pressure Change Along Coolant Passages in Sodium-Cooled Fast Reactor with Nek5000

To support the design efforts of advanced sodium-cooled fast reactors (SFRs), a series of computational fluid dynamics (CFD) simulations are performed to investigate the pressure change along various flow passages in the proposed SFR system. The simulations are carried out with the state-of-the-art spectral element flow solver, Nek5000. Two specific case studies are presented in this paper: the flow exiting the axial neutron reflector channels and the flow entering the fuel pin bundle. Due to the high Reynolds numbers expected, a Reynolds-averaged Navier-Stokes (RANS) approach is necessary to model the turbulence. A newly developed regularized k-omega RANS model is adopted in the related CFD calculations. The first case study explores the effect of Reynolds number on the pressure change when flow exits the reflector channels. The pressure change in this case has two major contributors: the change due to wall friction and the Bernoulli effect. It is noted that the nondimensional pressure loss follows a log-linear trend up to Re = 10 5 , and then the trend is flattened. In the second case study, the advanced NekNek coupling capability is tested where an integral domain can be divided into multiple subdomains with coupling interfaces, which would greatly ease the meshing process of complex engineering geometries and potentially save computational resources. The preliminary results obtained so far confirm the consistency between the NekNek results and those produced by regular Nek5000 simulation. The presented work demonstrates the readiness and flexibility of the related CFD techniques, which is part of the broader effort to leverage cutting-edge CFD to inform the advanced nuclear reactor designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Post-composing ontology terms for efficient phenotyping in plant breeding

Abstract Ontologies are widely used in databases to standardize data, improving data quality, integration, and ease of comparison. Within ontologies tailored to diverse use cases, post-composing user-defined terms reconciles the demands for standardization on the one hand and flexibility on the other. In many instances of Breedbase, a digital ecosystem for plant breeding designed for genomic selection, the goal is to capture phenotypic data using highly curated and rigorous crop ontologies, while adapting to the specific requirements of plant breeders to record data quickly and efficiently. For example, post-composing enables users to tailor ontology terms to suit specific and granular use cases such as repeated measurements on different plant parts and special sample preparation techniques. To achieve this, we have implemented a post-composing tool based on orthogonal ontologies providing users with the ability to introduce additional levels of phenotyping granularity tailored to unique experimental designs. Post-composed terms are designed to be reused by all breeding programs within a Breedbase instance but are not exported to the crop reference ontologies. Breedbase users can post-compose terms across various categories, such as plant anatomy, treatments, temporal events, and breeding cycles, and, as a result, generate highly specific terms for more accurate phenotyping.

Mathematical & Computational Biology↗

Multiphysics modelling in PyLith: poroelasticity

SUMMARY PyLith, a community, open-source code for modelling quasi-static and dynamic crustal deformation with an emphasis on earthquake faulting, has recently been updated with a flexible multiphysics implementation. We demonstrate the versatility of the multiphysics implementation by extending the code to model fully coupled continuum poromechanics. We verify the newly incorporated physics using standard benchmarks for a porous medium saturated with a slightly compressible fluid. The benchmarks include the 1-D consolidation problem as outlined by Terzaghi, Mandel’s problem for the 2-D case, and Cryer’s problem for the 3-D case. All three benchmarks have been added to the PyLith continuous integration test suite. We compare the closed form analytical solution for each benchmark against solutions generated by our updated code, and lastly, demonstrate that the poroelastic material formulation may be used alongside the existing fault implementation in PyLith.

Geochemistry & Geophysics↗

C-FOG: Life of Coastal Fog

C-FOG is a comprehensive bi-national project dealing with the formation, persistence, and dissipation (life cycle) of fog in coastal areas (coastal fog) controlled by land, marine, and atmospheric processes. Given its inherent complexity, coastal-fog literature has mainly focused on case studies, and there is a continuing need for research that integrates across processes (e.g., air–sea–land interactions, environmental flow, aerosol transport, and chemistry), dynamics (two-phase flow and turbulence), microphysics (nucleation, droplet characterization), and thermodynamics (heat transfer and phase changes) through field observations and modeling. Central to C-FOG was a field campaign in eastern Canada from 1 September to 8 October 2018, covering four land sites in Newfoundland and Nova Scotia and an adjacent coastal strip transected by the Research Vessel Hugh R. Sharp . An array of in situ, path-integrating, and remote sensing instruments gathered data across a swath of space–time scales relevant to fog life cycle. Satellite and reanalysis products, routine meteorological observations, numerical weather prediction model (WRF and COAMPS) outputs, large-eddy simulations, and phenomenological modeling underpin the interpretation of field observations in a multiscale and multiplatform framework that helps identify and remedy numerical model deficiencies. An overview of the C-FOG field campaign and some preliminary analysis/findings are presented in this paper.

58 GEOSCIENCES↗

Knowledge Spillovers and Cost Reductions in Solar Soft Costs

Despite the commonly acknowledged importance of knowledge spillovers in reducing solar soft costs, we are only beginning to answer a fundamental question: who learns what (knowledge acquisition), from whom (knowledge production), and how (spillover mechanisms)? Until recently, this important topic has been largely unexplored in the case of solar soft costs. Thus, this project set out to identify how knowledge spillovers affect soft costs in the U.S. photovoltaic (PV) installation industry, specifically how important spillovers are, what types of knowledge are most likely to spillover, and how networks of actors affect spillovers. Our findings offer insights for designing solutions that address problems associated with knowledge spillovers and that leverage spillovers to reduce solar soft costs. Recognizing the ambiguity in the definition of soft costs, i.e., “non-hardware costs,” and variability in soft cost categories, we developed the Solar Soft Cost Ontology (SSCO) to systematically identify key concepts related to soft costs, network actors, learning processes, and the relationships between them. This ontology served as a foundational organizational structure for the methodology of the remaining tasks: case studies, surveys, pricing analysis, patent analysis, network analysis, and project integration across tasks. While there is substantial learning among installers that is reducing the soft costs for PV installations, most of that learning is retained by firms rather than spread across the industry. The positive relationship between experience accumulation and cost reductions is typically explained as learning by doing (LBD), but we find that LBD effects are mediated by other learning mechanisms, including learning by searching and learning by interacting. Knowledge spillovers have significant potential to reduce solar PV soft costs, but successful knowledge spillover pathways are complex and non-trivial. There are a wide variety of ways to construct an installation business, thus categories of firms that can effectively cross-learn directly are small and what knowledge is relevant to whom is challenging and costly for firms to assess. This fragmentation limits the critical mass needed for spillover related soft cost reductions. Knowledge does not flow directly between installers. Indirect knowledge transfer pathways are critical: distributors, software providers, collaboratives, and hiring. Furthermore, diverse, more integrated knowledge networks tend to promote successful learning by organizations and across the system as a whole. Accordingly, we find the need to supporting the whole ecosystem using an integrated policy and programmatic approach to support installers, distributors, complementary sector, and facilitators. Overall, a deliberate policy-mix design is needed to reduce the solar PV deployment barrier in terms of installation cost reductions, because deployment policies could potentially interact with policies that facilitate network-building and technological innovation. A combination of deployment policies, innovation-support policies, and network-facilitating policies could potentially lead to a more desired market outcome through achieving higher joint learning rates from firms’ cumulative experiences developed in a more integrated production and deployment ecosystem.

14 SOLAR ENERGY↗

Hydrogen Generation and Industrial Heat Opportunities for Nuclear Plants in the Gulf Coast

The United States (U.S.) nuclear-generation fleet stands as a critical national strategic asset, playing a pivotal role in achieving climate goals. Operating on light-water reactor (LWR) technologies, this fleet provides the largest share of U.S. carbon-free electrical generation, ensuring 24/7 clean-energy stability. With a proven track record of reliability while operating at high-capacity factors, consistently above 90%, the existing nuclear fleet serves as a cornerstone for sustainable energy. The Department of Energy’s (DOE’s) Light Water Reactor Sustainability (LWRS), Flexible Plant Operations and Generation pathway addresses U.S. nuclear power plant (NPP) grid integration challenges in the face of evolving energy landscapes. Research at Idaho National Laboratory (INL) highlights the potential synergy between high-temperature steam-electrolysis (HTSE) technology and nuclear steam and electricity during periods of high renewable grid penetration. Large-scale nuclear-integrated hydrogen production through HTSE presents significant potential for decarbonizing such energy-intensive sectors as oil refining, petrochemicals, ammonia, and fertilizers. The strategic advantage lies in the nuclear sector’s capability to deliver clean electrical and/or steam output during periods of low demand. Nuclear-produced hydrogen—with its ability to provide high-purity clean H 2 well below the national standard of 1 kg of CO 2 per kg of H 2 —represents a breakthrough methodology. This emphasizes the crucial role NPPs can fill in addressing the increasing need for clean hydrogen, establishing them as essential contributors to decarbonization. This report specifically delves into hydrogen-generation opportunities from the U.S. Gulf Coast region. This study aims to assess NPP capabilities for hydrogen production and to identify practical nearby industrial and pipeline-operator off-takers for nuclear-integrated hydrogen production as well as to present some specific case-study analysis showing the conditions under which nuclear hydrogen production and sale can be profitable. Also considered in this report is preliminary analysis of nuclear-heat opportunities accessible near Waterford NPP via transportation of hypothetical steam pipelines and heat-exchange equipment.

08 HYDROGEN↗

Adding Efficiency to Renovations - Case Study: Bank

This case study describes the implementation of the Tenant Fit-Out Integrated Systems Package (ISP) at a retail bank branch, including project details, key takeaways, and data comparisons before and after the renovations.

integrated systems package, ISP, bank, retail, off↗

Assessing the Performance and Impact of PV Technologies on Storage in Hybrid Renewable Systems

Traditional monofacial photovoltaic (mPV) systems are commonly adopted and well-documented because of their lower upfront costs in comparison to bifacial photovoltaic (bPV) systems. This study investigates how PV technologies impact energy storage in grid-scale hybrid renewable systems, focusing on optimizing and assessing the performance of mPV and bPV technologies integrated with pumped storage hydropower. Using Ludington City, Michigan as a case study and analyzing real-world data such as solar irradiance, ambient temperature, and utility-scale load profiles, the research highlights the operational and economic benefits of bPV systems. The results reveal that bPV systems can pump approximately 10.38% more water annually to the upper reservoir while achieving a lower levelized cost of energy ($0.0578/kWh for bPV vs. $0.0672/kWh for mPV). This study underscores the outstanding potential of bPV systems in enhancing energy storage and management strategies, contributing to a more sustainable and resilient renewable energy future.

13 HYDRO ENERGY↗

On the lapse contour in the gravitational path integral

The gravitational path integral is usually implemented with a covariant action by analogy with other gauge field theories, but the gravitational case is different in important ways. A key difference is that the integrand has an essential singularity, which occurs at zero lapse where the spacetime metric degenerates. The lapse integration contour required to impose the local time reparametrization constraints must run from − ∞ to + ∞ , yet must not pass through zero. This raises the question: for an application—such as a partition function—where the constraints should be imposed, what is the correct integration contour, and why? We study that question by starting with the reduced phase space path integral, which involves no essential singularity. We observe that if the momenta are to be integrated before the lapse, to obtain a configuration space path integral, the lapse contour should pass below the origin in the complex lapse plane. This contour is also consistent with the requirement that quantum field fluctuation amplitudes have the usual short distance vacuum form, and with obtaining the Bekenstein-Hawking horizon entropy from a Lorentzian path integral. Published by the American Physical Society 2025

Banihashemi, Batoul (ORCID:0000000228679209)↗

Fast Solution of Fully Implicit Runge--Kutta and Discontinuous Galerkin in Time for Numerical PDEs, Part I: the Linear Setting

Fully implicit Runge--Kutta (IRK) methods have many desirable properties as time integration schemes in terms of accuracy and stability, but high-order IRK methods are not commonly used in practice with numerical PDEs due to the difficulty of solving the stage equations. This paper introduces a theoretical and algorithmic preconditioning framework for solving the systems of equations that arise from IRK methods applied to linear numerical PDEs (without algebraic constraints). Additionally, this framework also naturally applies to discontinuous Galerkin discretizations in time. Under quite general assumptions on the spatial discretization that yield stable time integration, the preconditioned operator is proven to have condition number bounded by a small, order-one constant, independent of the spatial mesh and time-step size, and with only weak dependence on number of stages/polynomial order; for example, the preconditioned operator for 10th-order Gauss IRK has condition number less than two, independent of the spatial discretization and time step. The new method can be used with arbitrary existing preconditioners for backward Euler-type time-stepping schemes and is amenable to the use of three-term recursion Krylov methods when the underlying spatial discretization is symmetric. The new method is demonstrated to be effective on various high-order finite-difference and finite element discretizations of linear parabolic and hyperbolic problems, demonstrating fast, scalable solution of up to 10th-order accuracy. The new method consistently outperforms existing block preconditioning approaches, and in several cases, the new method can achieve 4th-order accuracy using Gauss integration with roughly half the number of preconditioner applications and wallclock time as required using standard diagonally IRK methods.

97 MATHEMATICS AND COMPUTING↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Off-shell Partition Functions in 3d Gravity

We explore three-dimensional gravity with negative cosmological constant via canonical quantization. We focus on chiral gravity which is related to a single copy of PSL(2,R) Chern-Simons theory and is simpler to treat in canonical quantization. Its phase space for an initial value surface Σ is given by the appropriate moduli space of Riemann surfaces. We use geometric quantization to compute partition functions of chiral gravity on three-manifolds of the form Σ×S 1 , where Σ can have asymptotic boundaries. Most of these topologies do not admit a classical solution and are thus not amenable to a direct semiclassical path integral computation. We use an index theorem that expresses the partition function as an integral of characteristic classes over phase space. In the presence of n asymptotic boundaries, we use techniques from equivariant cohomology to localize the integral to a finite-dimensional integral over $\overline{M}$ g,n , which we evaluate in low genus cases. Higher genus partition functions quickly become complicated since they depend in an oscillatory way on Newton's constant. There is a precise sense in which one can isolate the non-oscillatory part which we call the fake partition function. We establish that there is a topological recursion that computes the fake partition functions for arbitrary Riemann surfaces Σ. As a result, there is a scaling limit in which the model reduces to JT gravity and our methods give a novel way to compute JT partition functions via equivariant localization.

Classical and Quantum Gravity↗

American cities in a time of global environmental change: the case of the Baltimore Social-Environmental Collaborative

The Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory seeks a new paradigm for urban climate research. Motivated by deep uncertainties in urban climate and the future of urban systems, BSEC works collaboratively across institutions and stakeholder groups to co-generate the science needed to advance energy security and resilience to extreme events across the city of Baltimore, Maryland, USA, and to do so in a manner that can inform similar efforts in other cities. BSEC begins with stakeholder priorities (health, affordable energy, etc) and designs observation networks and models to deliver climate science to address them. This takes the form of an iterative collaborative cycle, in which an initial research strategy is repeatedly updated in conversation with community partners, and researchers and stakeholders learn from each other. To date, this cycle has included multiple rounds of collaborative deliberation on urban heat mitigation, in which a multicriteria decision tool has been updated with more community-relevant spatial structure and modified optimization metrics. The guiding objective of this cycle is to inform potential ‘secure and resilient pathways’ for energy and infrastructure. In doing so, BSEC addresses fundamental urban science questions in natural and social sciences. It also tests our ability to integrate this science in a manner that advances participatory decision-making for urban resilience.

climate↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Branching heat exchangers

A heat exchanger includes an external casing and a core. The external casing includes a first inlet, a first outlet, a second inlet, and a second outlet. The core includes an array of branched channels connecting the first inlet and first outlet, an inlet header, and an outlet header. The inlet header is integrally formed with and fluidly connected to the first inlet. The outlet header is integrally formed with and fluidly connected to the first outlet. The branched channels and the external casing define a fluidic passage. The array of branched channels includes a first split, a first juncture, a secondary split, a secondary juncture, and a subset of splits and junctures. The first split and first juncture are common to an entirety of the array of branched channels. The subset of splits and junctures route fluid through interconnections between fluidly parallel branched channels.

Ranjan, Ram↗