Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Camera / Raw Data

This dataset contains camera images captured by the aft looking barge security camera mounted on the mast.

17 WIND ENERGY↗

Camera / Raw Data

This dataset contains camera images captured by the aft mounted barge security camera, looking towards the mast.

17 WIND ENERGY↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

CALSPEC: Wide Field Camera 3 Infrared Grism Spectrophotometry

The collections of spectral energy distributions (SEDs) in the Hubble Space Telescope (HST) CALSPEC database are augmented by 19 infrared (IR) SEDs from Wide Field Camera 3 (WFC3) IR grism spectra. Together, the two IR grisms, G102 and G141, cover the 0.8–1.7 μm range with resolutions of R = 200 and 150, respectively. These new WFC3 SEDs overlap existing CALSPEC Space Telescope Imaging Spectrograph (STIS) standard star flux distributions at 0.8–1 μm with agreement to ≲1%. Some CALSPEC standards already have near-IR camera and multi-object spectrogragh (NICMOS) SEDs; but in their overlap region at 0.8–1.7 μm, the WFC3 data have better wavelength accuracy, better spectral resolution, better repeatability, and, consequently, better flux distributions of ~1% accuracy in our CALSPEC absolute flux SEDs versus ~2% for NICMOS. With the improved SEDs in the WFC3 range, the modeled extrapolations to 32 μm for the James Webb Space Telescope flux standards begin to lose precision longward of the 1.7 μm WFC3 limit, instead of at the 1.0-μm-long wavelength limit for STIS. For example, the extrapolated IR flux longward of 1.7 μm for 1808347 increases by ~1% for the model fit to the data with WFC3, instead of just to the STIS SED alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Point Cloud of Cloud Points PCCP from CACTI Stereo Cameras

The Point Cloud of Cloud Points (PCCP) data set is composed of 3D coordinates describing the position of cloud features and images from which these coordinates are reconstructed. Images are captured in the daytime by two ARM cloud digital cameras (ACDCs) at CACTI S4a and S4b sites, at 20-second intervals. The two cameras are located at 32.1274oS,64.7139oW, and 32.1185oS, 64.7237oW. The 3D positions are detected with respect to the AMF base location at 32.1264oS, 64.7284oW, and 1141 m above sea level. The PCCP data format is the same as explained in PCCP VAP Technical Report.

54 ENVIRONMENTAL SCIENCES↗

The LSST Camera (LSSTCam)

The LSST Camera is the sole instrument for the NSF-DOE Vera C. Rubin Observatory and consists of a 3.2 gigapixel focal plane mosaic with in-vacuum controllers, dedicated guider and wavefront CCDs, a three-element corrector whose largest lens is 1.55m in diameter, six optical interference filters covering a 320-1050nm band pass with an out-of-plane filter exchange mechanism, and camera slow control and data acquisition systems capable of digitizing each image in 2 seconds.

79 ASTRONOMY AND ASTROPHYSICS↗

The Effect of a Pre-Lens Aperture on the Temperature Range and Image Uniformity of Microbolometer Infrared Cameras

This paper explores the temperature range extension of long-wavelength infrared (LWIR) cameras by placing an aperture in front of the lens. An aperture smaller than the lens will reduce the radiance to the sensor, allowing the camera to image targets much hotter than typically allowable. These higher temperatures were accurately determined after developing a correction factor which was applied to the built-in temperature calibration. The relationship between aperture diameter and temperature range is linear. The effect of pre-lens apertures on the image uniformity is a form of anti-vignetting, meaning the corners appear brighter (hotter) than the rest of the image. An example of using this technique to measure temperatures of high melting point polymers during 3D printing provide valuable information of the time required for the weld-line temperature to fall below the glass transition temperature.

3D Printing↗

Anger Camera Calibration and QA Software

Create an easy to use software package for calibration and QA testing of the Anger Camera. The software uses python scripts and interacts with two different C++ programs. The C++ programs simply transfer data to the python scripts via a file or UDP call. The python scripts analyze the data preform motor movement functions and create calibration data files for transfer to the Anger Camera configuration files.

Riedel, Richard A.↗

HIGH-ENERGY X-RAY PINHOLE CAMERA FOR HIGH-RESOLUTION ELECTRON BEAM SIZE MEASUREMENTS

The Advanced Photon Source (APS) is developing a multi-bend achromat (MBA) lattice based storage ring as the next major upgrade, featuring a 20-fold reduction in emittance. Combining the reduction of beta functions, the electron beam sizes at bend magnet sources may be reduced to reach 5 – 10 µm for 10% vertical coupling. The x-ray pinhole camera currently used for beam size monitoring will not be adequate for the new task. By increasing the operating photon energy to 120 – 200 keV, the pinhole camera’s resolution is expected to reach below 4 µm. The peak height of the pinhole image will be used to monitor relative changes of the beam sizes and enable the feedback control of the emittance. We present the simulation and the design of a beam size monitor for the APS storage ring.

Yang, B.↗

Vertically Integrated Edgeless Photon Imaging Camera

The Vertically Integrated Photon Imaging Chip - Large, (VIPIC-L), is a large area, small pixel (65μm), 3D integrated, photon counting ASIC with zero-suppressed or full frame dead-time-less data readout. It features data throughput of 14.4 Gbps per chip with a full frame readout speed of 56kframes/s in the imaging mode. VIPIC-L contain 192 x 192 pixel array and the total size of the chip is 1.248cm x 1.248cm with only a 5μm periphery. It contains about 120M transistors. A 1.3M pixel camera module will be developed by arranging a 6 x 6 array of 3D VIPIC-L’s bonded to a large area silicon sensor on the analog side and to a readout board on the digital side. The readout board hosts a bank of FPGA’s, one per VIPIC-L to allow processing of up to 0.7 Tbps of raw data produced by the camera.

Fahim, Farah↗

Analyzing the Effects of Geometric Lane Constraints on Radar-Based Sensing of Available Vehicle Headway Using Mapped Lane Geometry and Camera Registration of Lane Position

Commercial trucks are currently equipped with a single front-facing RADAR mounted on the front bumper, as this is a sensor useful for Cooperative Adaptive Cruise Control, Emergency Braking Systems, and many similar Connected and Automated vehicle functions that require longitudinal vehicle control. This paper investigates the use of a bumper-mounted RADAR to perform traffic characterization around the ego-vehicle to obtain an estimate of the furthest headway that can be considered as a reliable estimate of open maneuvering space, such that there are no vehicles within the same lane as the ego-vehicle. This available headway in front of a vehicle is an important parameter in an ongoing study whose goal is to obtain improvements in fuel economy for highway driving of a tractor-trailer. But headway availability depends on the correct attribution of RADAR measured vehicles to be either within the ego-lane, or outside the lane. The attribution of lane designations to specific RADAR targets depend strongly on lane geometry and the ability to align RADAR measurements to the ego-lane. This work investigates how knowledge of lane geometries, as well as sensor performance characteristics, may improve the trust in a RADAR measurement of open headway distance in front of a vehicle. Specifically, several strategies for associating local traffic either within or excluded from the ego lane are considered, and the possible sources of error in headway calculations are investigated for each strategy. The strategies differ by the availability of lane geometry information and RADAR target association to lane constraints, which in turn is assumed to be supplied by the use of map data and secondary camera measurements. It is observed that combining RADAR with lane-geometry maps help detect headway up to and beyond RADAR range limit with exceptions tied to a particular road. These errors can further be minimized by using camera measurements, and this reduction in error is analyzed assuming errors associated with registering images to lane markers. Here, the results, based on actual highway routes measured with our test vehicle, reveal: that RADAR data without lane geometry strongly limits the trusted headway measurement from this sensor; that lane geometry maps can greatly increase the trusted range, usually beyond the RADAR’s range limits; and that image-based registration of lane markers to lane geometry should have accuracies allowing full-range trust in the RADAR target measurements of headway.

33 ADVANCED PROPULSION SYSTEMS↗

Multi-Frame X-Ray Imaging Using a Streak Camera with a Patterned Photocathode, LAO-008-16, Year 1 of 2

Presentation describes development of a new time-resolved x-ray imaging system based on compressed ultrafast photography (CUP) to achieve multi-frame imaging for energies in the 1–10 keV range with a frame rate between 1 to 10 frames per nanosecond depending on the sweep time. A patterned gold photocathode was constructed for use with an existing Kentech x-ray streak camera. Significant work in reconstruction algorithms was performed to enable reconstructions of data that are much less sparse. These algorithms were tested with optical streak camera CUP data acquired at Livermore Operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications and Deployment of Neutron Scatter Cameras in Nuclear Safeguards Scenarios

Neutron scatter cameras (NSCs) are a type of directionally sensitive neutron detector that rely on two consecutive neutron scattering events to localize a source of neutrons. NSCs can be used to locate, image, and identify unknown neutron sources or verify the geometry and identity of known sources. Much technical progress has been made in improving NSC designs, but little literature exists exploring the full range of practical application of neutron scatter cameras. This paper seeks to identify scenarios related to nuclear security and non-proliferation where deployment of NSCs may be useful. These situations could include: limited searches for sources during cargo screening, counting nuclear warheads for treaty verification, verification of special nuclear material during inspections, imaging nuclear contamination, imaging nuclear reactor cores, searching for lost sources, and matching neutron images in shipper/receiver or inventory management scenarios. These scenarios are examined with respect to existing NSC designs and proposed designs in terms of usefulness and practicality of deployment when compared to currently used detection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Dark Energy Camera (DECam)

In this paper we describe the Dark Energy Camera (DECam), which will be the primary instrument used in the Dark Energy Survey. DECam will be a 3 sq. deg. mosaic camera mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). It consists of a large mosaic CCD focal plane, a five element optical corrector, five filters (g,r,i,z,Y), a modern data acquisition and control system and the associated infrastructure for operation in the prime focus cage. The focal plane includes of 62 2K x 4K CCD modules (0.27"/pixel) arranged in a hexagon inscribed within the roughly 2.2 degree diameter field of view and 12 smaller 2K x 2K CCDs for guiding, focus and alignment. The CCDs will be 250 micron thick fully-depleted CCDs that have been developed at the Lawrence Berkeley National Laboratory (LBNL). Production of the CCDs and fabrication of the optics, mechanical structure, mechanisms, and control system for DECam are underway; delivery of the instrument to CTIO is scheduled for 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rifle-like camera for long distance face recognition

An improved long-range facial recognition system is provided. The facial recognition system includes an integrated, rifle-like mounting platform with modular and interchangeable components, including a machine-vision camera, a facial recognition module, and an aiming scope. The mounting platform includes an elongated frame, a hand grip, a shoulder stock, and an underbody support attachment for an optional bipod. The mounting platform provides an intuitive, shoulder-operated support structure for stabilizing the machine-vision camera and reducing vibrations that otherwise inhibit long distance imaging.

Bolme, David S.↗

Systems and methods of adaptive two-wavelength single-camera imaging thermography (ATSIT) for accurate and smart in-situ process temperature measurement during metal additive manufacturing

A two-wavelength, single-camera imaging thermography system for in-situ temperature measurement of a target, comprising: a target light path inlet conduit for receiving a target light beam reflected from the target; a beam splitter installed in a splitter housing at a distal end of the target light path conduit, wherein the beam splitter divides the target light beam into a first light beam and a second light beam; a first light path conduit emanating from the splitter housing comprising a first aperture iris installed within the first light path conduit for aligning the first light beam; a first band pass filter installed within the first light path conduit for regulating the first light beam to a first wavelength λ1 and an optional half waveplate installed within the first light path conduit to modulate a polarization ratio of the first light beam of λ1 wavelength; a second light path conduit emanating from the splitter housing comprising a second aperture iris installed within the second light path conduit for aligning the second light beam; a second band pass filter installed within the second light path conduit for regulating the second light beam to a second wavelength λ2; a junction housing, wherein distal ends of each of the first and second light path conduits are connected to the junction housing; a polarizing beam splitter installed in the junction housing, wherein the polarizing beam splitter reflects the first light beam of λ1 wavelength along the same path or a parallel path of the second light beam of λ2 wavelength that passes directly through the polarizing beam splitter unreflected to create a merged light beam comprising light of λ1 and λ2 wavelengths; and a light path outlet conduit connected to the junction for directing the merged beam to a high-speed camera for imaging.

Zhao, Xiayun↗

ProxiScan™: A Novel Camera for Imaging Prostate Cancer

ProxiScan is a compact gamma camera suited for high-resolution imaging of prostate cancer. Developed by Brookhaven National Laboratory and Hybridyne Imaging Technologies, Inc., ProxiScan won a 2009 R&D 100 Award, sponsored by R&D Magazine to recognize the top 100 technological achievements of the year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAPSHOT USA 2020: A second coordinated national camera trap survey of the United States during the COVID-19 pandemic

Managing wildlife populations in the face of global change requires regular data on the abundance and distribution of wild animals, but acquiring these over appropriate spatial scales in a sustainable way has proven challenging. Here, in this study, we present the data from Snapshot USA 2020, a second annual national mammal survey of the USA. This project involved 152 scientists setting camera traps in a standardized protocol at 1485 locations across 103 arrays in 43 states for a total of 52,710 trap-nights of survey effort. Most (58) of these arrays were also sampled during the same months (September and October) in 2019, providing a direct comparison of animal populations in 2 years that includes data from both during and before the COVID-19 pandemic. All data were managed by the eMammal system, with all species identifications checked by at least two reviewers. In total, we recorded 117,415 detections of 78 species of wild mammals, 9236 detections of at least 43 species of birds, 15,851 detections of six domestic animals and 23,825 detections of humans or their vehicles. Spatial differences across arrays explained more variation in the relative abundance than temporal variation across years for all 38 species modeled, although there are examples of significant site-level differences among years for many species. Temporal results show how species allocate their time and can be used to study species interactions, including between humans and wildlife. These data provide a snapshot of the mammal community of the USA for 2020 and will be useful for exploring the drivers of spatial and temporal changes in relative abundance and distribution, and the impacts of species interactions on daily activity patterns. There are no copyright restrictions, and please cite this paper when using these data, or a subset of these data, for publication.

54 ENVIRONMENTAL SCIENCES↗