Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Transforming Buildings Around the World

Buildings are where we live, work, go to school, gather as a community, and so much more. Globally, buildings are responsible for 30% of energy consumption and 26% of energy-related emissions. The National Renewable Energy Laboratory (NREL) is committed to adapting tools and capabilities to support emerging economies and improve the energy efficiency and flexibility of their buildings.

building technology innovation↗

Residential Buildings: How Smart are Today’s Smart Homes?

Recent years have seen a dramatic increase in the number of “smart” devices available for residential buildings. This column describes opportunities presented by advances in smart home technology that could impact our homes and how we interact with them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Integrated Models for Electrical Distribution Network Planning and District-Scale Building Energy Use

The increase of greenhouse emissions caused by a rise in global energy consumption is pushing the scientific community to develop tools that address key environmental, techno-economic and social issues. One specific area of focus is to create tools that enable the design of high-performance energy districts, including grid-interactive efficient buildings and electrical distribution infrastructure. This paper outlines the approach of integrating a synthetic distribution network tool (RNM-US) with URBANopt™, a modular and customizable software development kit for thermal and electrical modelling of buildings and energy systems at a district scale. First, we describe the algorithms implemented to integrate RNM-US with URBANopt to automatically generate the distribution network for the district considered. Following, we present a case study for the potential uses of the RNM-US integrations with URBANopt, highlighting the capabilities for economic and technical analysis of the distribution network built in relation to the electricity needs of the modelled buildings.

30 DIRECT ENERGY CONVERSION↗

Occupant-Centric key performance indicators to inform building design and operations

Building performance indicators are widely used to guide building design and track and benchmark operational performance. Traditional building performance indicators mostly focus on the energy efficiency perspective. As occupants are the primary building service recipients in residential and most commercial buildings, their comfort and wellbeing are crucial. As such, this study first identified significant attributes of occupant-centric key performance indicators (KPIs) and analyzed the diverse factors that should be considered in formulating an occupant-centric KPI. Then a suite of occupant-centric KPIs were synthesized from the review and enhancement of existing occupant-related performance metrics. The proposed occupant KPIs represent the occupant lens on three integrative aspects of building performance: resource use (including energy and water), indoor environmental quality, and human–building interactions. A simulation-based case study was conducted to demonstrate how occupant-centric KPIs can be used to quantify the impacts of building operation changes from the occupants’ point of view. Highlights: Occupant-centric metrics are currently ad hoc and limited, yet crucial to inform building design and operations. Literature was reviewed to reveal the state-of-the-art and gaps of occupant-centric metrics. A suite of occupant-centric key performance indicators (KPIs) covering five groups of building services were synthesized. Proposed occupant KPIs represent three aspects of performance: resource use and demand, occupant comfort and health, and human–building interactions. A case study using whole building simulation was conducted to demonstrate the use of occupant-centric KPIs in evaluating building operations during a power outage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Building Business Network (B-Biz): Addressing Gaps in the High-Performance Building Technology Market, Especially for Underserved Customers

Increased market intelligence and business model innovation is needed to build contractor confidence in high-performance building technologies in order to increase the speed and scale of adoption to meet the U.S. Department of Energy's building stock decarbonization goals. Although there have been important innovations in energy efficiency, affordability, and decarbonization of building technologies, consumers are not purchasing these technologies at the necessary speed and scale partially due to a gap in institutional understanding around barriers contractors face in providing and servicing these technologies. Small businesses in this market must mitigate risk around high-performance building technologies, limiting their opportunities in the market and impacting the rate of adoption. The Building Business Network (B-Biz) aims to provide high-performance building technology solutions to underserved customers by collaborating with local small businesses that provide and service high-performance building technologies in communities with the lowest rates of adoption. This research explores the current market, the importance of business models, and the opportunity to utilize small businesses to address market gaps in underserved communities.

B-Biz↗

Advancing Energy Efficiency Through Workforce Training

This Final Technical Report summarizes the work done on to develop and implement the Energy Basics Training Tool with industry partners and the Pacific Northwest National Laboratory. This project leveraged existing infrastructure and content developed by DOE in the Building America Solution Center (BASC) and Building Science Education Solution Center (BSESC) to design model content sets for use in entry-level construction programs at the high school certificate, boot camp, and other entry level training programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Market Driven Residential Energy Codes: Comparing Performance in a Changing Technological Environment

The research project is undertaken to better understand the changing relationship between the two basic methods of building energy code compliance – prescriptive and performance – and how those methods relate to each other with respect to advancements in building energy computer simulation standards and capabilities. The International Energy Efficiency Code (IECC) is a model code adopted by many jurisdictions across the United States. Historically, the prescriptive compliance methodology has been preferred in most jurisdictions. The prescriptive methodology requires meeting or exceeding specific efficiency minimums for each envelope component. This tends to be a simple method to teach and verify. A more involved prescriptive alternative called the Total UA alternative is sometimes used. This method requires some multiplication, summing, and comparison to compute, so it is done with a fairly simple computer program. However, advances in computer and building energy simulation technology have resulted in increased use of more detailed performance compliance methods. The performance compliance method establishes the annual energy cost threshold via hourly simulation models. The compliance threshold is determined with a comparison building model simulation with geometry similar to the proposed home and with energy feature parameters and efficiencies as specified in the IECC. This project examines relationships between the two methods of building energy code compliance, including: • Overall annual energy use based on utility bill analysis by compliance method • Code official work processes with respect to compliance methods • Gaps and issues associated with building code compliance methods • Simulated energy use difference between compliance methods • Code compliance cost as a function of compliance method • Code compliance labeling effectiveness for high performance residences • Getting to net zero energy use and net zero greenhouse gas emissions through high performance code alternatives • Electronic code permitting and compliance alternatives

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Optimizing Grid-interactive Efficient Building Designs with Stacked Value Streams

Grid-interactive efficient buildings (GEBs) are those characterized by the combination of energy efficiency and demand flexibility with smart technologies and communications to not only deliver greater affordability and comfort to buildings, but also help utilities manage grid operations and lower system costs. This paper presents an innovative techno-economic assessment framework to effectively examine different GEB design options, explore various use cases, define technically achievable benefits, and thereby assist in informed decision-making. In particular, building load flexibility, thermal storage, and battery energy storage are considered. Advanced optimal dispatch problem is formulated to maximize the stacked value streams from multiple, competing use cases, subject to the physical capabilities and operational flexibility associated with different designs and configurations. Comprehensive case studies were performed for a real-world building to evaluate the cost-effectiveness of different GEB designs and offer in-depth insights. It was found that the proposed assessment method could effectively capture the costs and benefits linked to each GEB design option. Furthermore, the study revealed that outage mitigation and demand response are the two most significant sources of benefits for GEBs.

Ma, Xu↗

Conducting Field Validations of Commercial Energy Efficiency Technologies with Underserved Communities: Preprint

Underserved communities in the United States often experience the negative impacts of climate change and environmental degradation but enjoy few of the benefits of technological and environmental advances. The White House has addressed this inequity through the Justice40 initiative, which requires 40% of the benefits of select federal investments to be directed to underserved communities (The White House, 2022). Clean energy and energy efficiency are two highlighted investment categories, so the U.S. Department of Energy will guide implementation of the Justice40 initiative by, among other things, decreasing energy burdens, increasing parity in clean energy technology access and adoption, and increasing energy resiliency. A strategy for reaching these goals is to evaluate and validate new energy efficiency technologies in commercial buildings in underserved communities, where buildings may be older, smaller, and have deferred maintenance due to historical underinvestment. This paper assesses the proficiency of the technologies under these conditions and increases awareness of the benefits to the communities. In addition, historical redlining and past negative experiences with government and large institutions may make residents wary of participating in these field validations. Researchers, therefore, may need to spend more time building relationships and matching technologies to buildings. In this paper, we analyzed technical reports to identify common required and desired field validation building characteristics, and conducted semi-structured expert conversations to identify key stages and major themes of engaging underserved communities. Our results indicate that the benefits to both the community and energy efficiency research justify the effort. The White House. (2022). Justice40. https://www.whitehouse.gov/environmentaljustice/justice40/

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Developing a Database of Bio-based Materials for Building Envelope Applications

Oak Ridge National Laboratory (ORNL) has been funded by the Department of Energy (DOE) to help accelerate the introduction of building envelope materials that would reduce the carbon footprint of the buildings sector. The DOE’s Building Technologies Office has historically sought to resolve the knowledge gaps regarding the energy efficiency and moisture durability of building envelope systems and to develop the data, guidance, and tools needed to facilitate rapid industry adoption of high-performance, moisture-managed envelope systems. This project will help accelerate the widespread acceptance of a new generation of building materials developed specifically with the intent of reducing the carbon footprint of buildings. We have produced a database of hygrothermal transport properties on low embodied carbon building materials that can be added to energy and durability simulation tools. Properties that were measured include density, heat capacity, thermal conductivity as a function of temperature and relative humidity, moisture dependent permeance, and sorption isotherms as a function of relative humidity. These data sets were measured following consensus national standards using state-of-the-art facilities. The data has been compiled and is being made available to building designers who require these data to assess these new materials in their designs. We will publish the data and seek its addition to reference databases such as the ASHRAE Handbook of Fundamentals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonizing Building Thermal Systems: A How-to Guide for Heat Pump Systems and Beyond

Buildings account for a substantial portion of carbon emissions, primarily due to the widespread use of fossil fuels in heating systems. Decarbonization of heating is essential to meet climate targets and reduce the environmental impact of buildings. Heat pumps are capable of leveraging renewable energy sources and can provide heating and cooling in an energy-efficient manner. By leveraging heat pump technology, buildings can significantly reduce their carbon footprint, minimize energy consumption, and decrease their reliance on fossil fuels. The design and construction community plays a pivotal role in facilitating the transition to heat pump systems for heating and cooling. However, this transition requires specialized knowledge and expertise. This resource was developed for architects, engineers, and contractors in response to an industry need for a comprehensive technical resource that guides them through the intricacies of heat pump system design, installation, and maintenance. This resource provides detailed information on system sizing, selection of appropriate heat systems, heat sources, and integration with existing building systems. Moreover, it emphasizes best practices for ensuring operational efficiency, system longevity, and reliability. The development of this recourse was a collaborative effort between NREL/DOE Better Buildings Design and Construction Allies and ASHRAE Task Force for Building Decarbonization. This resource is composed of two complimentary portions that will be completed and released on separate time frames. The first portion will be completed and released in 2023, while the second portion will be released in 2024.

building thermal systems↗

A systematic review of building energy sufficiency towards energy and climate targets

Among the sufficiency, efficiency, and renewable frameworks for reducing energy use and energy-related carbon emissions, Building Energy Sufficiency (BES) is gaining attention from policy makers and engineers. Despite the significant role of the building sector in the success of national energy and climate plans, there is a lack of research on the drivers, technologies, and effective policy instruments required to achieve BES in the building operational phase. To fill this gap, this study presents a systematic review of the definition and paradigm of BES and concludes that BES should address both occupant demand and energy or emissions requirements simultaneously. The characteristics of occupant demand in building services are divided into four dimensions: time and space, quality and quantity, control and adjustment, and flexibility. Technical options regarding the building architecture, the envelope system, and the building energy system are reviewed. Finally, policy implications and recommendations are discussed. As a result, the multiple benefits and multidisciplinary nature of BES justify further research and accelerated policy implementation in developed and developing countries.

54 ENVIRONMENTAL SCIENCES↗

Energy Efficiency Assessment for a Microgrid in the Community of Castañer, Puerto Rico

The Cooperativa Hidroeléctrica de la Montaña (Cooperativa) and the Interstate Renewable Energy Council office in Puerto Rico (IREC) are leading the development of a community solar photovoltaic (PV) microgrid comprised of a 225 kWDC photovoltaic system tied to a 500 kWh storage system in the Community of Castañer, in the town of Lares in Puerto Rico. This microgrid will support the electricity needs of eight essential businesses and four homes. The Cooperativa and IREC requested technical assistance to help conduct a comprehensive energy efficiency assessment for the commercial buildings to maximize the impact of the solar PV microgrid. The goal was to identify energy conservation measures that would have the highest impact in terms of reducing electricity demand in order to; reduce the size and cost of the PV microgrid; and reduce the annual operating costs for building owners.

14 SOLAR ENERGY↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Residential Home Repairs, Energy Efficiency, and Electrification in the Hill District of Pittsburgh [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies. This report summarizes the insights from stakeholder engagement with organizations that provide home repair services, weatherization, and residential energy efficiency in the Hill District as well as from a building analysis to characterize Hill District housing stock and the potential costs and benefits of energy efficiency and electrification measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗