Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bolt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

EVA Planning: Using Neutral Buoyancy Laboratory (NBL) Training to Predict in-Flight Energy Expenditure

Metabolic rate (“met rate”) is the amount of energy expended over a period of time and is influenced by many factors including body composition, level of physical activity, resting metabolic rate, sex, age, and food intake. Met rate is measured during Extravehicular Activity (EVA) training at the Neutral Buoyancy Laboratory (NBL) and during in-flight EVAs through indirect calorimetry, calculating energy expenditure from respiratory measurements of O 2 consumption and/or CO 2 production. During Extravehicular Activity (EVA) planning, metabolic cost is important to consider and is used to inform EVA duration based on spacesuit consumables associated with life support systems. Currently, NBL and previous ISS EVA met rate data for specified crewmembers are utilized to predict in-flight EVA metabolic costs based on a proposed EVA timeline. Timeline data collected during training is used to relate met rates to specific EVA activities, which are in turn assigned to more generalized EVA task categories, categorizing by both task type and restraint type. EVA task categories include EVA Setup/Cleanup, Worksite Setup/Cleanup, Cable Routing, Bolts, Fluid Connectors, Electrical Connectors, R&R Work, Miscellaneous Work, Incapacitated Crew Rescue (being rescued or performing), Assisted Crew Rescue (being assisted or performing), and Translation. Restraint types consist of Free-Float, Body Restraint Tether (BRT), Articulating Portable Foot Restraint (APFR), and Space Station Remote Manipulator System (SSRMS). From a crewmember’s historical data, individualized 10th, 50th and 90th percentile met rate estimates are generated for each task category and used to estimate the proposed EVA timeline metabolic cost. In-flight metabolic data (“As-Executed”) from recent ISS US EVAs 85-88 (totaling eight EVA crewmember met rates) was compared with their predicted metabolic cost (“As-Planned”) to evaluate the accuracy of the current met rate estimation method. Across the four EVAs, As-Executed Cumulative EVA Total Metabolic Cost (M = 5893.78 BTU, SD = 816.60) was not significantly different compared to As-Planned Cumulative EVA Total Metabolic Cost (M = 6106.60 BTU, SD = 826.62; t(7) = 0.751 , p = .477). Though not a significant difference, generally, As-Planned total estimates were slightly higher than As-Executed total metabolic cost. Relative Error for Cumulative EVA Total Metabolic Cost ranged from -33% to 14.7%, depending on the crewmember and EVA. When comparing As-Planned to A-Executed EVA task categories for Bolts, Electrical Connectors, EVA Cleanup, EVA Setup, Miscellaneous Work, Translation, Worksite Cleanup, and Worksite Setup during these EVAs, no significant differences were observed, however, there was a significant difference in As-Planned (M = 783.71 BTU, SD = 408.88) compared to As-Executed (M = 608.87 BTU, SD = 425.29) metabolic cost for the task category of Repair-and-Replace (R&R) Work (t(17) = 3.21 , p = .005). Looking closer within the R&R Work task category, As-Executed R&R Work with Free-Float restraint type (M = 706.17 BTU, SD = 352.18) was significantly less than As-Planned R&R Work with Free-Float restraint type (M= 887.96 BTU, SD = 381.42; t(12) = 2.59, p < .024). As-Executed R&R Work with SSRMS Restraint type (M = 355.89 BTU, SD = 534.65) was not significantly different from As-Planned values (M = 512.69 BTU, SD = 383.34; t(4) = 1.88, p = 0.132). These findings suggest that the energy expended performing R&R Work (Free-Float) is lower in flight than predicted. Accurate predictions of the metabolic cost of EVA are essential for planning and executing successful ISS EVAs. Overall, the current met rate prediction method is similar to actual in-flight values, slightly erring on the side of overestimation. Future work includes analysis of more historical in-flight EVA data to increase the power of the analysis, evaluating the NBL-ISS met rate conversion factor between NBL and ISS tasks, as well as exploring methods of substitution when crewmembers are missing prior task category data.

Lauren Cox↗

Pressure seal ring may be effective over wide temperature range

Positive pressure seal rings seal bolted flange joints in pressure vessels containing fluids whose temperatures can vary over a wide range. The seal rings mate with grooves in the flanges and compensate for the excessive thermal expansion or contraction of a gasketed joint.

Source record↗

Diffusion bonding makes strong seal at flanged connector

Copper strip seals a high pressure fluid system connector so that it is insensitive to relaxation of the bolt loads. The copper strip is diffusion bonded to the surfaces of the connector flange by application of high pressure and temperature.

Gitzendanner, L. G.↗

Spherical joint connects axially misaligned flanges

Interconnecting straight tube connects axially misaligned flanges in a duct assembly. It adjusts to accommodate variations in relative location of the flanges by pivoting. Adjustment is by spherical mating faces and a spherical-faced indexing swivel flange for bolting backup.

Mc Groarty, J. D.↗

Study made of transfer of heat energy through metal joints in vacuum environment

Heat energy transfer is concentrated closely around a melted joint and the temperature drop across it decreases rapidly as the bolt and nut are tightened to a minimum torque level. Flat metal surfaces pressed together display a cyclical improvement in heat energy transfer as the interface pressure is increased.

Elliot, D. H.↗

Development of helical seal for high temperature /2000 degrees F/ application

Helical seal is used to seal bolted flange joints in a high temperature environment. The seal design incorporates a new cross-sectional shape, a metal strip with a slight radius, and the use of premolded asbestos. It provides equal load distribution under compression loads, allows for minimum loss and recovery values, and increases the temperature range.

Held, C.↗

Tensile testing grips ensure uniform loading of bimetal tubing specimens

Tensile testing grip uniformly distributes stresses to the internal and external tube of bimetal tubing specimens. The grip is comprised of a slotted external tube grip, a slotted internal tube grip, a machine bolt and nut, an internal grip expansion cone, and an external grip compression nut.

Driscol, S. D.↗

Sealing a rubber bladder between two sections of an accumulator

Leak-free clamping of a two section accumulator is accomplished by a flat metallic ring molded peripherally to the rubber flange of the bladder, and an inset rubber seal bonded to the face of the flange of each section. Method maintains constant torque on the clamping bolts.

Schartau, G. M.↗

Pressure transducer

Pressure-sensitive transducer, consisting of a series of spindle-supported electrically conductive metal washers connected to electrical sensing circuitry, determines the force exerted between a mounting bolt and nut on relatively fragile components.

Baker, C. D.↗

Quick-set temporary bonding clamps

Method of bonding materials to a flat surface eliminates the use of bolts to hold the pieces together. Two adhesives are used, the primary or permanent bonding material and a quick setting adhesive. No permanent after effects are left on the surfaces to which the materials are bonded.

Baker, C. D.↗

Low cost lobed bearing

Separate sectors for each lobed area of the bearing are assembled into the bearing housing individually and bolted tightly against the housing inside diameter. The center of a grinding wheel and the center of the housing are offset, resulting in the desired inner radius and tilt of the sector.

Schuller, F. T.↗