Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

Knowledge gaps for neuromorphic ionic computing

BACKGROUND Neuromorphic computing, inspired by the human brain’s ability to process information efficiently, represents a transformative approach to computation. In this Review, we explore the emerging field of neuromorphic ionic computing, which leverages ionic conduction and coupling to mimic neural processes, and identify critical knowledge gaps that must be addressed to realize its full potential. A central theme of the discussion is energy efficiency, a challenge that is both a limitation and an opportunity for this technology. Although complementary metal-oxide semiconductor (CMOS)–based neuromorphic technologies have made strides in scaling to billions of neurons and are increasingly applied in artificial intelligence and numerical computing, they remain orders of magnitude behind the human brain in terms of connectivity and energy efficiency. Neuromorphic ionic computing promises to overcome these limitations by leveraging the distinct architectural and operational principles of the brain. Our brains achieve this energy efficiency by combining several key features: using the same network elements to store and process information; using an incredibly complex and massively interconnected three-dimensional (3D) network of locally active elements that enables sparsity, robustness in the presence of noise, adaptation, and life-long learning; computing at comparatively low voltage and frequency; and last, taking advantage of a plethora of ions and small molecules as information carriers. Here, we propose that ionic computing systems can take advantage of similar features to achieve substantial gains in energy efficiency. ADVANCES Since the first reports of neuromorphic ionic behavior in nanofluidic channels, we have witnessed an explosion of reports that used ionic devices to produce synaptomimetic behaviors. However, achieving the goals of ionic computing requires not only implementation of much more sophisticated device functionality but also overcoming fundamental barriers in materials science, device architecture, and system integration. Current ionic devices, even those incorporating state-of-the-art materials, still suffer from limited functionality and stability, which restrict their performance and increase energy demands. Developing new materials with enhanced ionic properties is essential to overcome these limitations. Similarly, the design of neuromorphic devices must evolve to leverage the particular advantages of ionic processes. Existing architectures often follow a single-information-carrier logic of conventional electronics or are constructed of mesoscale fluidics, failing to capitalize on the energy-efficient mechanisms inherent to ionic systems or implement the multiple-information-carrier paradigm. Current neuromorphic chips focus on large-scale networks of analog memory elements based on mechanisms such as charge trap (flash), filamentary, phase change, or spin, which are built on top of a network of artificial CMOS neurons. Although such prototype networks have achieved impressive performance, it is difficult to envision how they can implement the key features such as massive connectivity, sophisticated plasticity, adaptability, sparsity, and “multichromatic” computing. Although small-scale devices have demonstrated promising results, integrating them, maintaining energy efficiency, and implementing temperature control as systems grow in complexity and size to computationally relevant scale remain major hurdles. Furthermore, interfacing neuromorphic ionic devices with existing computing technologies presents technical and conceptual challenges that will require innovative approaches that combine insights from neuroscience, materials science, and engineering. OUTLOOK Despite these challenges, the potential impact of neuromorphic ionic computing is profound with potential applications ranging from artificial intelligence to robotics and beyond. We also argue that neuromorphic ionic computing systems should not, at least in the beginning, compete with CMOS technologies but rather should focus on applications that require extreme energy efficiency with chemical and/or biological compatibility, such as biomedical applications (for example, brain-computer interfaces), environmental monitoring, and agricultural and food applications. Ultimately, this Review highlights the crucial role of interdisciplinary collaboration in advancing the field. Neuromorphic ionic computing is not merely a technological innovation; it represents a substantial step toward sustainable computation, aligning with the growing demand for energy-conscious solutions in a world that is increasingly reliant on data and computation.

Neuromorphic↗

SU-F-I-50: Finite Element-Based Deformable Image Registration of Lung and Heart

Purpose: Photodynamic therapy (PDT) is used after surgical resection to treat the microscopic disease for malignant pleural mesothelioma and to increase survival rates. Although accurate light delivery is imperative to PDT efficacy, the deformation of the pleural volume during the surgery impacts the delivered light dose. To facilitate treatment planning, we use a finite-element-based (FEM) deformable image registration to quantify the anatomical variation of lung and heart volumes between CT pre-(or post-) surgery and surface contours obtained during PDT using an infrared camera-based navigation system (NDI). Methods: NDI is used during PDT to obtain the information of the cumulative light fluence on every cavity surface point that is being treated. A wand, comprised of a modified endotrachial tube filled with Intralipid and an optical fiber inside the tube, is used to deliver the light during PDT. The position of the treatment is tracked using an attachment with nine reflective passive markers that are seen by the NDI system. Then, the position points are plotted as three-dimensional volume of the pleural cavity using Matlab and Meshlab. A series of computed tomography (CT) scans of the lungs and heart, in the same patient, are also acquired before and after the surgery. The NDI and CT contours are imported into COMSOL Multiphysics, where the FEM-based deformable image registration is obtained. The NDI and CT contours acquired during and post-PDT are considered as the reference, and the Pre-PDT CT contours are used as the target, which will be deformed. Results: Anatomical variation of the lung and heart volumes, taken at different times from different imaging devices, was determined by using our model. The resulting three-dimensional deformation map along x, y and z-axes was obtained. Conclusion: Our model fuses images acquired by different modalities and provides insights into the variation in anatomical structures over time.

60 APPLIED LIFE SCIENCES↗

Status and efficacy of countermeasures to physiological deconditioning from space flight

The recent biomedical investigations conducted on the Space Shuttle and Spacelab have provided a wealth of biomedical information, including the ability to test the efficacy of proposed countermeasures. This achievement was made possible by the ability to conduct mechanistic and control-interventive studies simultaneously with a large number of individuals over a relatively brief period and to compare these data with results obtained from the Skylab missions. Comparisons between short- and long-duration results were limited to establishing trends or extrapolating from short-duration missions. To date, we have evaluated several protocols involving the lower-body negative pressure (LBNP) device, the bicycle-ergometer, the treadmill and preparations for body-fluid replenishment. In many instances, the traditional means of applying these protocols were not sufficient to protect against space-related deconditioning. This paper will review current countermeasures and compare their efficacy to that of existing protocols. Results from in-flight and ground-based experiments will be presented to illuminate the recommended protocols and procedures.

short duration↗

Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monatomic Oxygen Makes Materials Biocompatible

Treatment with monatomic oxygen activates surfaces of biomedical and biotechnical materials without adversely affecting properties of bulk and without introducing toxic or otherwise dangerous solvent residues. Treatment used to create carpetlike texture increasing surface area and encouraging cells to adhere and grow. On silicone tubing for vascular implants, carpet surface improves acceptance by body. On polymer beads and vessels, surface increases effectiveness of growing, storing, and separating cell cultures. Monatomic oxygen relatively abundant in upper atmosphere of Earth, thus treatments carried out on Space Shuttle missions. Alternatively, one of several high-energy neutral-beam devices used in terrestrial laboratories.

Spaulding, Glenn↗

Time Dependence of Intrafraction Patient Motion Assessed by Repeat Stereoscopic Imaging

Purpose: To quantify intrafraction patient motion and its time dependence in immobilized intracranial and extracranial patients. The data can be used to optimize the intrafraction imaging frequency and consequent patient setup correction with an image guidance and tracking system, and to establish the required safety margins in the absence of such a system. Method and Materials: The intrafraction motion of 32 intracranial patients, immobilized with a thermoplastic mask, and 11 supine- and 14 prone-treated extracranial spine patients, immobilized with a vacuum bag, were analyzed. The motion was recorded by an X-ray, stereoscopic, image-guidance system. For each group, we calculated separately the systematic (overall mean and SD) and the random displacement as a function of elapsed intrafraction time. Results: The SD of the systematic intrafraction displacements increased linearly over time for all three patient groups. For intracranial-, supine-, and prone-treated patients, the SD increased to 0.8, 1.2, and 2.2 mm, respectively, in a period of 15 min. The random displacements for the prone-treated patients were significantly higher than for the other groups, namely 1.6 mm (1 SD), probably caused by respiratory motion. Conclusions: Despite the applied immobilization devices, patients drift away from their initial position during a treatment fraction. These drifts are in general small if compared with conventional treatment margins, but will significantly contribute to the margin for high-precision radiation treatments with treatment times of 15 min or longer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-dose phase contrast tomography with conventional x-ray sources

Purpose: The edge illumination (EI) x-ray phase contrast imaging (XPCi) method has been recently further developed to perform tomographic and, thus, volumetric imaging. In this paper, the first tomographic EI XPCi images acquired with a conventional x-ray source at dose levels below that used for preclinical small animal imaging are presented. Methods: Two test objects, a biological sample and a custom-built phantom, were imaged with a laboratory-based EI XPCi setup in tomography mode. Tomographic maps that show the phase shift and attenuating properties of the object were reconstructed, and analyzed in terms of signal-to-noise ratio and quantitative accuracy. Dose measurements using thermoluminescence devices were performed. Results: The obtained images demonstrate that phase based imaging methods can provide superior results compared to attenuation based modalities for weakly attenuating samples also in 3D. Moreover, and, most importantly, they demonstrate the feasibility of low-dose imaging. In addition, the experimental results can be considered quantitative within the constraints imposed by polychromaticity. Conclusions: The results, together with the method's dose efficiency and compatibility with conventional x-ray sources, indicate that tomographic EI XPCi can become an important tool for the routine imaging of biomedical samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-201-05: Silicon Array Dosimeter in Situ with Electronic Portal Image Device for Simultaneous Transit Dose and Image Verification in Radiotherapy

Purpose: To investigate an Electronic Portal Imaging Device (EPID) coupled to a 2D array dosimeter to provide simultaneous imaging and dose verification. Methods: The novel dual detector configuration comprised of a 2D diode array dosimeter, referred to as a Magic Plate (MP) placed directly on a standard EPID. Dose response of the MP was evaluated by measuring the detector’s response with respect to off-axis position and field size with 30 cm of solid water (SW) acting as a transit object in the beam. Measurements were performed with 3, 5, 10 and 15 mm SW build-up and compared to 2D ionisation chamber array (ICA) measurements and the PinnacleTM treatment planning system (TPS) at a source to detector distance of 150 cm with a 6 MV beam. Clinical dosimetric performance was evaluated by measuring a number of intensity-modulated radiation therapy (IMRT) beams in transit geometry. Imaging performance of the EPID was quantified by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of a Rando phantom were used for qualitative assessment. Results: Measured MP off-axis and field size response agreed within 2% of TPS and ICA responses when measured using 15 mm SW build-up. Clinical IMRT beams had gamma pass rates of ≥95% at 3%/3mm criteria. Measured CNR and spatial resolution (f50) were 264.96, 210.6, and 0.41, 0.40 with build-up of 5 and 15 mm respectively for the dual detector configuration. CNR and spatial resolution of 643.9 and 0.41 were measured for standard EPID. CNR was quantitatively worse in the dual detector configuration. Differences in imaging performance were not visible in a qualitative assessment using a Rando phantom. Conclusion: Combining a prototype MP 2D dosimeter with a conventional EPID did not significantly detract from the performance of either device and has the potential for simultaneous on-line patient transit dosimetry and image assessment in radiation therapy. Cancer Institute NSW Australia(Research Equipment Grant 10/REG/1-20) and Cancer Council NSW (Grant ID RG 1-06)

60 APPLIED LIFE SCIENCES↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Microfluidic approaches to synchrotron radiation-based Fourier transform infrared (SR-FTIR) spectral microscopy of living biosystems

A long-standing desire in biological and biomedical sciences is to be able to probe cellular chemistry as biological processes are happening inside living cells. Synchrotron radiation-based Fourier transform infrared (SR-FTIR) spectral microscopy is a label-free and nondestructive analytical technique that can provide spatiotemporal distributions and relative abundances of biomolecules of a specimen by their characteristic vibrational modes. Despite great progress in recent years, SR-FTIR imaging of living biological systems remains challenging because of the demanding requirements on environmental control and strong infrared absorption of water. To meet this challenge, microfluidic devices have emerged as a method to control the water thickness while providing a hospitable environment to measure cellular processes and responses over many hours or days. This paper will provide an overview of microfluidic device development for SR-FTIR imaging of living biological systems, provide contrast between the various techniques including closed and open-channel designs, and discuss future directions of development within this area. Even as the fundamental science and technological demonstrations develop, other ongoing issues must be addressed; for example, choosing applications whose experimental requirements closely match device capabilities, and developing strategies to efficiently complete the cycle of development. These will require imagination, ingenuity and collaboration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Miniature biotelemeter giving 10 channels of wideband biomedical data.

A miniature biotelemeter has been developed for sensing and transmitting multiple channels of wideband biomedical data over a radio link. Its small size and weight make it capable of being carried by free-moving laboratory animals as small as rats. Ten data channels each of 5-kHz data bandwidth are provided to permit monitoring of a wide variety of physiological signals. Multichannel telemetry of electroencephalograms, electrocardiograms, electromyograms, state functions, and dynamic processes such as blood flow and body chemistry are possible applications. Utilization of newly available monolithic chip components, low-power COS/MOS MSI digital logic, and state-of-the-art hybrid mounting techniques makes this novel device useful for both research and clinical bioinstrumentation.

Carraway, J.↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

SU-G-JeP2-11: Polymer Gels as 3D QA Devices in Magnetic Resonance-Guided Radiation Therapy

Purpose: To demonstrate the potential of polymer gels to serve as 3D QA devices in MR-guided radiotherapy. Methods: Custom-designed polymer gel dosimeters (MGS Research, Madison, CT) were centered on the penumbras of a radiation field, parallel to the magnetic field lines inside a 1.5 T MR scanner integrated with a 7 MV linac (MR-Linac). 15 Gy were delivered perpendicular to the magnetic field. Coronal MR images were acquired with a 2D balanced-Fast Field Echo (b-FFE) sequence in real-time during irradiation and with a 2D spin echo sequence at different times after irradiation. Signal intensities (SI) were measured inside and outside the radiation field on b-FFE images obtained during irradiation. Spin-spin relaxation rate (R2) maps were calculated from images after irradiation and penumbra widths were calculated from these maps. Results: A difference in SI between areas of the dosimeter inside and outside of the radiation field could be measured immediately after the beam was turned on. The difference in SI increased throughout the duration of the exposure. R2 values from immediately after irradiation were 83% of those measured 24h post-irradiation. At 1h after irradiation, the R2 values were 87% of those at 24h indicating that polymerization of the gel was still ongoing. At 24h postirradiation the width of the 80/20 penumbra on the left field edge measured 6.5 mm and on the right 5.6 mm. Conclusion: The MR-Linac allows for MR imaging during treatment and measurements of 3D dose distributions with steep dose gradients without having to transfer dosimeters for read-out. The results showed promise for polymer gels as relative 3D QA devices to verify radiation treatment plans delivered by an MR-Linac. To our knowledge, this was the first time that polymer gels were used for real-time image acquisition. Further investigations into the application of polymer gel dosimetry on MR-Linac are ongoing.

60 APPLIED LIFE SCIENCES↗

Artificial Intelligence Medical Support for Long-Duration Space Missions

We envision an artificial intelligence (AI) based system that will provide support and recommendations to the crew medical officer (CMO) and ground flight surgeon during long-duration space missions. Such a system would be pretrained on the knowledgebase of clinical knowledge on Earth, minimizing the amount of Earth data that needs to be transferred into space. Then during deployment, the system would be constantly refined through active learning from diverse streams of data from sensors in the spacecraft, data collected daily from individual astronauts, and human-in-the-loop feedback from the crew. The model could be interrogated for predictions and recommendations on personalized crew health based on the overall status of the spacecraft, medicinal stores, and status of other crew members. Adaptation techniques would be used to incorporate spaceflight data that have very different distributions from the training data due to the extreme environment. Edge computing and the most advanced neuromorphic processing would enable computation in scenarios with low power and bandwidth, while dimensionality reduction would be employed to ensure that the input data streams from spaceflight are as small as possible. In order to realize this long-term vision, several hardware and software aspects need to be developed and assembled. First, models pretrained on Earth biomedical data would need to be evaluated for predictive accuracy, and the best one selected. That model would need to be adapted to learn from diverse, sparse, and inconsistently measured data streams, as well as human-in-the-loop feedback. A data integration, standardization, and dimensionality reduction methodology would need to be developed to handle all data types and feed them into the model. Once the software and data infrastructure is developed, it would need to be integrated with small footprint compute processors and tested in high-radiation, high-vibration, unregulated temperature situations. As a short-term goal, we recommend to focus on the development of the data and model software structure. Several large language models (LLM) already exist that have been trained on Earth biomedical and clinical knowledgebases, including BioMedLLM, Med-PaLM, SPOKE LLM, and Foresight. These models need to be evaluated for accuracy and the best one chosen for a proof-of-concept structure, while maintaining awareness of the accelerating AI field and incorporating any newly improved model architectures as needed. Then, we recommend to develop a database of synthetic data types to mimic the diverse data streams that are expected in a long-duration space mission. This should include environmental and microbial data from the spacecraft, non-invasive data from wearables and point-of-care devices employed by astronauts, and more invasive molecular and physiological monitoring of clinical and biomarker data from astronauts. The data standardization methodology should be developed, and these data streams used to refine the clinical LLM. Several scenarios should be developed that could plausibly come up in a long-duration space mission, and changes or aberrations introduced to the data at specific times to mimic these scenarios. Then, question and answer tasks should be designed to interrogate the model for predictions and recommendations, with acceptable answers already identified.

Artificial Intelligence↗

Low temperature plasma biomedicine: A tutorial review

Gas discharge plasmas formed at atmospheric pressure and near room temperature have recently been shown to be potentially useful for surface and wound sterilization, antisepsis, bleeding cessation, wound healing, and cancer treatment, among other biomedical applications. This tutorial review summarizes the field, stressing the likely role of reactive oxygen and nitrogen species created in these plasmas as the biologically and therapeutically active agents. Reactive species, including radicals and non-radical compounds, are generated naturally within the body and are now understood to be essential for normal biological functions. These species are known to be active agents in existing therapies for wound healing, infection control, and cancer treatment. But they are also observed at elevated levels in persons with many diseases and are associated with aging. The physical and chemical complexity of plasma medical devices and their associated biochemical effects makes the development of safe, effective plasma medical devices and procedures a challenge, but encouragingly rapid progress has been reported around the world in the last several years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The diverse applications of plasma

Plasma being the fourth state of matter has always been an attraction for Physicists and Chemists. With the advent of time, plasma energy has been recognized in having widening horizons in the field of Biomedical Sciences. Plasma medicine can be subdivided into three main fields; Non-thermal atmospheric-pressure direct plasma for medical therapy; Plasma-assisted modification of bio-relevant surfaces and Plasma-based bio-decontamination and sterilization. The basis of the research is that as it has free carrier molecules, it has the ability to target specific cells and regulate functions like wound healing. Plasma does not harm healthy human cells but can kill bacteria and possibly even cancer cells to help treat various diseases. Nosocomial infection control, prevention and containment of contagious diseases, disinfection of medical devices, surface treatment (heat and UV sensitive surfaces) are research of interest. Recent success in generating plasma at very low temperature ie. Cold plasma makes the therapy painless. It has the ability to activate cellular responses and important mechanisms in the body. They target specific molecules such as prothrombin for blood coagulation, cytokines for killing bacteria, and angiogenesis for tissue regeneration. Plasma has bactericidal, fungicidal and virucidal properties. Plasma technology has flourishing future in diverse fields like Textiles, Nanofabrication, Automotives, Waste management, Microbiology, Food Hygiene, Medical Science like Skin treatments, sterilisation of wounds, Hand disinfection, Dental treatments etc. Food hygiene using plasma can be achieved in disinfection of food containers, food surface disinfection, hygiene in food handling, preparation and packaging. Therefore Plasma is most promising field for budding Scientist for fluorishing research in Biological Sciences.

60 APPLIED LIFE SCIENCES↗