Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analog control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Benchmarking Quantum Simulators Using Ergodic Quantum Dynamics

Here we propose and analyze a sample-efficient protocol to estimate the fidelity between an experimentally prepared state and an ideal target state, applicable to a wide class of analog quantum simulators without advanced spatiotemporal control. Our protocol relies on universal fluctuations emerging from generic Hamiltonian dynamics, which we discover in the present work. It does not require fine-tuned control over state preparation, quantum evolution, or readout capability, while achieving near optimal sample complexity: a percent-level precision is obtained with ~103 measurements, independent of system size. Furthermore, the accuracy of our fidelity estimation improves exponentially with increasing system size. We numerically demonstrate our protocol in a variety of quantum simulator platforms, including quantum gas microscopes, trapped ions, and Rydberg atom arrays. We discuss applications of our method for tasks such as multiparameter estimation of quantum states and processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Remotely Operated Multiple Array Acoustic Range (ROMAAR) and its application for the measurement of airplane flyover noise footprints

The ROMAAR now in operation at NASA will allow direct measurement and display of aircraft noise in several measurement units during takeoff, landing, and flyby operations. This information, in addition to its application in terms of ground noise footprints, will also permit determination of the statistical variation of footprints or contours due to the atmosphere or aircraft operational parameters, and a measure of the impact of various noise reduction techniques and hardware on ground noise footprints. The methods, techniques, and equipment developed for the ROMAAR concept are applicable to CTOL, STOL, General Aviation, and VTOL aircraft. ROMAAR represents a unique combination of state of the art digital and analog noise recording methods, computer-controlled digital communications methods, radar-tracking facilities, quick-look weather capabilities, and a large data handling facility complemented by a large capacity curve fitting and plotting routine. The ROMAAR is set apart from the standard airport noise monitoring system by having the unique features mentioned above plus the fact that at present as many as 38 separate (but simultaneous) noise measurements can be made for each aircraft overflight.

Hilton, D. A.↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗

The Magsat precision vector magnetometer

This paper examines the Magsat precision vector magnetometer which is designed to measure projections of the ambient field in three orthogonal directions. The system contains a highly stable and linear triaxial fluxgate magnetometer with a dynamic range of + or - 2000 nT (1 nT = 10 to the -9 weber per sq m). The magnetometer electronics, analog-to-digital converter, and digitally controlled current sources are implemented with redundant designs to avoid a loss of data in case of failures. Measurements are carried out with an accuracy of + or - 1 part in 64,000 in magnitude and 5 arcsec in orientation (1 arcsec = 0.00028 deg).

Acuna, M. H.↗

Modeling and analysis of several classes of self-oscillating inverters. I - State-plane representations. II - Model extension, classification, and duality relationships

The present investigation is concerned with an important class of power conditioning networks, taking into account self-oscillating dc-to-square-wave transistor inverters. The considered circuits are widely used both as the principal power converting and processing means in many systems and as low-power analog-to-discrete-time converters for controlling the switching of the output-stage semiconductors in a variety of power conditioning systems. Aspects of piecewise-linear modeling are discussed, taking into consideration component models, and an equivalent-circuit model. Questions of singular point analysis and state plane representation are also investigated, giving attention to limit cycles, starting circuits, the region of attraction, a hard oscillator, and a soft oscillator.

Lee, F. C. Y.↗

Efficient computerized model for dynamic analysis of energy conversion systems

In searching for the optimum parameters that minimize the total life cycle cost of an energy conversion system, various combinations of components are examined and the resulting system performance and associated economics are studied. The systems performance and economics simulation computer program (SPECS) was developed to fill this need. The program simulates the fluid flow, thermal, and electrical characteristics of a system of components on a quasi-steady state basis for a variety of energy conversion systems. A unique approach is used in which the set of characteristic equations is solved by the Newton-Raphson technique. This approach eliminates the tedious iterative loops which are found in comparable programs such as TRNSYS or SOLTES-1. Several efficient features were also incorporated such as the centralized control and energy management scheme, and analogous treatment of energy flow in electrical and mechanical components, and the modeling of components of similar fundamental characteristics using generic subroutines. Initial tests indicate that this model can be used effectively with a relatively small number of time steps and low computer cost.

Hughes, R. D.↗

System Decommutes And Displays Telemetry Data

TDPlus computer program software system for decommutation of pulse-code-modulation (PCM) telemetry signals. Provides synchronization, conversion into engineering units, and display of serial bit streams. Transforms IBM PC-compatible computer into PCM-telemetry-decommutation system. Synchronizes telemetric signals data and enables conversion back into such meaningful forms as voltage, current, pressure, and the like. Also controls operation of digital-to-analog converters to ship data to paper strip charts or to parallel digital ports for offloading to other computers. Software used to process actual data only when telemetry-data-processing computer modified in accordance with specifications contained in "TDPlus TM Data Processor" (GSC-13291). Written in Turbo C and 8088 Assembly language.

Massey, D. E.↗

Analog-digital simulation of transient-induced logic errors and upset susceptibility of an advanced control system

A simulation study is described which predicts the susceptibility of an advanced control system to electrical transients resulting in logic errors, latched errors, error propagation, and digital upset. The system is based on a custom-designed microprocessor and it incorporates fault-tolerant techniques. The system under test and the method to perform the transient injection experiment are described. Results for 2100 transient injections are analyzed and classified according to charge level, type of error, and location of injection.

Carreno, Victor A.↗

Using Magnetic Fields to Control Convection during Protein Crystallization: Analysis and Validation Studies

The effect of convection during the crystallization of proteins is not very well understood. In a gravitational field, convection is caused by crystal sedimentation and by solutal buoyancy induced flow and these can lead to crystal imperfections. While crystallization in microgravity can approach diffusion limited growth conditions (no convection), terrestrially strong magnetic fields can be used to control fluid flow and sedimentation effects. In this work, we develop the analysis for magnetic flow control and test the predictions using analog experiments. Specifically, experiments on solutal convection in a paramagnetic fluid were conducted in a strong magnetic field gradient using a dilute solution of Manganese Chloride. The observed flows indicate that the magnetic field can completely counter the settling effects of gravity locally and are consistent with the theoretical predictions presented. This phenomenon suggests that magnetic fields may be useful in mimicking the microgravity environment of space for some crystal growth ana biological applications where fluid convection is undesirable.

Ramachandran, N.↗

Development of CMOS Active Pixel Image Sensors for Low Cost Commercial Applications

JPL, under sponsorship from the NASA Office of Advanced Concepts and Technology, has been developing a second-generation solid-state image sensor technology. Charge-coupled devices (CCD) are a well-established first generation image sensor technology. For both commercial and NASA applications, CCDs have numerous shortcomings. In response, the active pixel sensor (APS) technology has been under research. The major advantages of APS technology are the ability to integrate on-chip timing, control, signal-processing and analog-to-digital converter functions, reduced sensitivity to radiation effects, low power operation, and random access readout.

solid-state image sensors active pixel sensor APS ↗

SDR Input Power Estimation Algorithms

The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) provides experimenters an opportunity to develop and demonstrate experimental waveforms in space. The SDR has an analog and a digital automatic gain control (AGC) and the response of the AGCs to changes in SDR input power and temperature was characterized prior to the launch and installation of the SCAN Testbed on the ISS. The AGCs were used to estimate the SDR input power and SNR of the received signal and the characterization results showed a nonlinear response to SDR input power and temperature. In order to estimate the SDR input from the AGCs, three algorithms were developed and implemented on the ground software of the SCAN Testbed. The algorithms include a linear straight line estimator, which used the digital AGC and the temperature to estimate the SDR input power over a narrower section of the SDR input power range. There is a linear adaptive filter algorithm that uses both AGCs and the temperature to estimate the SDR input power over a wide input power range. Finally, an algorithm that uses neural networks was designed to estimate the input power over a wide range. This paper describes the algorithms in detail and their associated performance in estimating the SDR input power.

Nappier, Jennifer M.↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems and methods for self-synchronized digital sampling

Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

Samson, Jr., John R.↗