Construction of narrow-band regenerative amplifier for momentum imaging spectroscopy of lithium dimer

We constructed a Ti:Sapphire narrow-band regenerative amplifier as the probe laser of the experiment of momentum imaging spectroscopy of lithium dimer. The spectral profile of the regenerative cavity was designed by three birefringent filters and a plate of etalon. With 1.1-mJ pumping by the second harmonics of Nd:YLF laser, mode-locked seed pulses were amplified to {approx}25 {mu}J at 1-kHz repetition, with the bandwidth of {approx}0.7 cm{sup -1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous stimulated Raman, Brillouin, and electron-acoustic scattering reveals a potential saturation mechanism in Raman plasma amplifiers

In a Raman plasma amplifier, the aim is to create plasma conditions in which Raman backscattering is the fastest growing instability, outrunning all competing effects so that it is possible to amplify and compress a laser beam to unprecedented unfocused intensities by utilizing that instability. However, achieving high efficiencies via this scheme has proven very difficult experimentally. Recent data show the simultaneous occurrence of stimulated Raman scattering (SRS), stimulated Brillouin scattering (SBS), and stimulated electron-acoustic scattering (SEAS). The appearance of SEAS is indicative of strong particle trapping, the existence of which is hard to justify without highlighting the interplay between SRS and SBS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase locking of an S-band wide-gap klystron amplifier with high power injection driven by a relativistic backward wave oscillator

Theoretical analyses and preliminary experiments on the phase-locking characteristics of an inductively loaded 2-cavity wide-gap klystron amplifier (WKA) with high power injection driven by a GW-class relativistic backward wave oscillator (RBWO) are presented. Electric power of the amplifier and oscillator is supplied by a single accelerator being capable of producing dual electron beams. The well phase-locking effect of the RBWO-WKA system requires the oscillator have good frequency reproducibility and stability from pulse to pulse. Thus, the main switch of the accelerator is externally triggered to stabilize the diode voltage and then the working frequency. In the experiment, frequency of the WKA is linearly locked by the RBWO. With a diode voltage of 530 kV and an input power of {approx}22 MW, an output power of {approx}230 MW with the power gain of {approx}10.2 dB is obtained from the WKA. As the main switch is triggered, the relative phase difference between the RBWO and the WKA is less than {+-}15 Degree-Sign in a single shot, and phase jitter of {+-}11 Degree-Sign is obtained within a series of shots with duration of about 40 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband calibrated scattering parameters characterization of a superconducting quantum interference device amplifier

In this work, we characterize the 2-port scattering parameters of a superconducting quantum interference device amplifier at {approx}20 mK over several gigahertz of bandwidth. The measurement reference plane is positioned on a 6.25 {Omega} microstrip line situated directly at the input and output of the device by means of a thru-reflect-line cryogenic calibration procedure. From the scattering parameters, we derive the device available power gain, isolation, and input impedance over the 2-8 GHz range. This measurement methodology provides a path towards designing wide-band matching circuits for low impedance superconducting amplifiers operating at dilution refrigerator temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carrier dynamics in inhomogeneously broadened InAs/AlGaInAs/InP quantum-dot semiconductor optical amplifiers

We report on a characterization of fundamental gain dynamics in recently developed InAs/InP quantum-dot semiconductor optical amplifiers. Multi-wavelength pump-probe measurements were used to determine gain recovery rates, following a powerful optical pump pulse, at various wavelengths for different bias levels and pump excitation powers. The recovery was dominated by coupling between the electronic states in the quantum-dots and the high energy carrier reservoir via capture and escape mechanisms. These processes determine also the wavelength dependencies of gain saturation depth and the asymptotic gain recovery level. Unlike quantum-dash amplifiers, these quantum-dots exhibit no instantaneous gain response, confirming their quasi zero-dimensional nature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High fidelity qubit readout with the superconducting low-inductance undulatory galvanometer microwave amplifier

We describe the high fidelity dispersive measurement of a superconducting qubit using a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG preamplifier achieves gain of 19 dB and yields a signal-to-noise ratio improvement of 9 dB over a state-of-the-art HEMT amplifier. We demonstrate a separation fidelity of 99% at 700 ns compared to 59% with the HEMT alone. The SLUG displays a large dynamic range, with an input saturation power corresponding to 700 photons in the readout cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross-correlation measurement of quantum shot noise using homemade transimpedance amplifiers

We report a cross-correlation measurement system, based on a new approach, which can be used to measure shot noise in a mesoscopic conductor at milliKelvin temperatures. In contrast to other measurement systems in which high-speed low-noise voltage amplifiers are commonly used, our system employs homemade transimpedance amplifiers (TAs). The low input impedance of the TAs significantly reduces the crosstalk caused by unavoidable parasitic capacitance between wires. The TAs are designed to have a flat gain over a frequency band from 2 kHz to 1 MHz. Low-noise performance is attained by installing the TAs at a 4 K stage of a dilution refrigerator. Our system thus fulfills the technical requirements for cross-correlation measurements: low noise floor, high frequency band, and negligible crosstalk between two signal lines. Using our system, shot noise generated at a quantum point contact embedded in a quantum Hall system is measured. The good agreement between the obtained shot-noise data and theoretical predictions demonstrates the accuracy of the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 15 MHz bandwidth, 60 V{sub pp}, low distortion power amplifier for driving high power piezoelectric transducers

This paper presents the design and the realization of a linear power amplifier with large bandwidth (15 MHz) capable of driving low impedance ultrasonic transducers. The output current driving capability (up to 5 A) and low distortion makes it suitable for new research applications using high power ultrasound in the medical and industrial fields. The electronic design approach is modular so that the characteristics can be scaled according to specific applications and implementation details for the circuit layout are reported. Finally the characterization of the power amplifier module is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design of Si-based nanoplasmonic structure as an antenna and reception amplifier for visible light communication

Visible light communication has been widely investigated due to its larger bandwidth and higher bit rate, and it can combine with the indoor illumination system that makes it more convenient to carry out. Receiving and processing the visible light signal on chip request for nanophotonics devices performing well. However, conventional optical device cannot be used for light-on-chip integration at subwavelength dimensions due to the diffraction limit. Herein, we propose a design of Si-based nanoplasmonic structure as an antenna and reception amplifier for visible light communication based on the interaction between Si nanoparticle and Au nanorod. This device integrates the unique scattering property of high-refractive index dielectric Si nanoparticles, whose scattering spectrum is dependent on the particle size, with the localized surface plasmon resonance of Au nanorod. We calculated the spectra collected by plane detector and near field distribution of nanostructure, and theoretically demonstrate that the proposed device can act as good receiver, amplifier and superlens during the visible light signal receiving and processing. Besides, unlike some other designs of nanoantenna devices focused less on how to detect the signals, our hybrid nanoantenna can realize the transfer between the scattering source and the detector effectively by Au nanorod waveguides. These findings suggest that the designed nanoplasmonic structure is expected to be used in on-chip nanophotonics as antenna, spectral splitter and demultiplexer for visible light communication.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving the maximum transmission distance of continuous-variable quantum key distribution using a noiseless amplifier

We show that the maximum transmission distance of continuous-variable quantum key distribution in presence of a Gaussian noisy lossy channel can be arbitrarily increased using a heralded noiseless linear amplifier. We explicitly consider a protocol using amplitude and phase modulated coherent states with reverse reconciliation. Assuming that the secret key rate drops to zero for a line transmittance T{sub lim}, we find that a noiseless amplifier with amplitude gain g can improve this value to T{sub lim}/g{sup 2}, corresponding to an increase in distance proportional to log g. We also show that the tolerance against noise is increased.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical amplifier based on guided polaritons in GaN and ZnO

We propose a scheme of an optical amplifier based on GaN and ZnO waveguides operating in the regime of strong coupling between photonic modes and excitonic resonances. Amplification of the guided exciton-polaritons is obtained by stimulated scattering from the excitonic reservoir, which is found to be fast enough compared with the large velocity of the guided polariton modes. We analyze the device parameters at different temperatures. We find that an 80 μm-long amplifier can provide a gain of 10 dB at room temperature, being supplied by 5 mA current in the cw regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time- and power-dependent operation of a parametric spin-wave amplifier

We present the experimental observation of the localized amplification of externally excited, propagating spin waves in a transversely in-plane magnetized Ni{sub 81}Fe{sub 19} magnonic waveguide by means of parallel pumping. By employing microfocussed Brillouin light scattering spectroscopy, we analyze the dependency of the amplification on the applied pumping power and on the delay between the input spin-wave packet and the pumping pulse. We show that there are two different operation regimes: At large pumping powers, the spin-wave packet needs to enter the amplifier before the pumping is switched on in order to be amplified while at low powers the spin-wave packet can arrive at any time during the pumping pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilayer-graphene-based amplifier of surface acoustic waves

The amplification of surface acoustic waves (SAWs) by a multilayer graphene (MLG)-based amplifier is studied. The conductivity of massless carriers (electrons or holes) in graphene in an external drift electric field is calculated using Boltzmann’s equation. At some carrier drift velocities, the real part of the variable conductivity becomes negative and MLG can be employed in SAW amplifiers. Amplification of Blustein’s and Rayleigh’s SAWs in CdS, a piezoelectric hexagonal crystal of the symmetry group C{sub 6v}, is considered. The corresponding equations for SAW propagation in the device are derived and can be applied to other substrate crystals of the same symmetry. The results of the paper indicate that MLG can be considered as a perspective material for SAW amplification and related applications.

36 MATERIALS SCIENCE↗

Traveling wave parametric amplifier with Josephson junctions using minimal resonator phase matching

Josephson parametric amplifiers have become a critical tool in superconducting device physics due to their high gain and quantum-limited noise. Traveling wave parametric amplifiers (TWPAs) promise similar noise performance, while allowing for significant increases in both bandwidth and dynamic range. We present a TWPA device based on an LC-ladder transmission line of Josephson junctions and parallel plate capacitors using low-loss amorphous silicon dielectric. Crucially, we have inserted λ/4 resonators at regular intervals along the transmission line in order to maintain the phase matching condition between pump, signal, and idler and increase gain. We achieve an average gain of 12 dB across a 4 GHz span, along with an average saturation power of −92 dBm with noise approaching the quantum limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quartz enhanced photoacoustic H{sub 2}S gas sensor based on a fiber-amplifier source and a custom tuning fork with large prong spacing

A quartz enhanced photoacoustic spectroscopy (QEPAS) sensor, employing an erbium-doped fiber amplified laser source and a custom quartz tuning fork (QTF) with its two prongs spaced ∼800 μm apart, is reported. The sensor employs an acoustic micro-resonator (AmR) which is assembled in an “on-beam” QEPAS configuration. Both length and vertical position of the AmR are optimized in terms of signal-to-noise ratio, significantly improving the QEPAS detection sensitivity by a factor of ∼40, compared to the case of a sensor using a bare custom QTF. The fiber-amplifier-enhanced QEPAS sensor is applied to H{sub 2}S trace gas detection, reaching a sensitivity of ∼890 ppb at 1 s integration time, similar to those obtained with a power-enhanced QEPAS sensor equipped with a standard QTF, but with the advantages of easy optical alignment, simple installation, and long-term stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a multimode coplanar waveguide parametric amplifier

We characterize a Josephson parametric amplifier based on a flux-tunable quarter-wavelength resonator. The fundamental resonance frequency is ∼1 GHz, but we use higher modes of the resonator for our measurements. An on-chip tuning line allows for magnetic flux pumping of the amplifier. We investigate and compare degenerate parametric amplification, involving a single mode, and nondegenerate parametric amplification, using a pair of modes. We show that we reach quantum-limited noise performance in both cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing

We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗