Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WINDOWS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Generic Advanced Computing Framework for Executing Windows-based Dynamic Contingency Analysis Tool in Parallel on Cluster Machines

Dynamic contingency analysis tool (DCAT) has been developed to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. By including more customized protection models and corrective actions into the Windows-based commercial tools, DCAT can help operators understand the cascading behavior and find mitigation approaches to reduce the risk of cascading outages in a more realistic manner. In order to further enhance the capability of DCAT, this paper presents a design of an advanced computing framework that enables DCAT to run on a cluster machine to improve its computational performance. This framework is generic and can be applied to other Windows-based simulation tools to fill the technical gap of applying advanced computing technology to vendors' Windows-based tools. The preliminary tests using medium to large power systems have shown the effectiveness of this framework and its potential for accelerating the adoption of advanced computing in utilities.

Advanced computing, dynamic contingency analysis, ↗

Cooling plate assembly for plasma windows positioned in a beam accelerator system

A beam accelerator system operable to produce a medical isotope, including an ion accelerator that generates an ion beam; a low-pressure chamber; an anode adjacent and fluidly connected to the low-pressure chamber; a plasma window adjacent and fluidly connected to the anode; and a cathode housing adjacent and fluidly connected to the plasma window. The plasma window has a plurality of plates, each plate having an aperture that is aligned with an aperture in one or more adjacent plates to form a plasma channel. One or more plates in the plurality of plates includes a unitary plate having an aperture therein, and one or more cooling channels entering the unitary plate at a first side of the unitary plate and exiting the unitary plate at a second side of the unitary plate. The one or more cooling channels run through a thickness of the unitary plate.

Gribb, Tye↗

Database of Low-e Storm Window Energy Performance across U.S. Climate Zones

This is an update of a report that describes process, assumptions, and modeling results produced Create a Database of U.S. Climate-Based Analysis for Low-E Storm Windows. The scope of the overall effort is to develop a database of energy savings and cost effectiveness of low-E storm windows in residential homes across a broad range of U.S. climates using the National Energy Audit Tool (NEAT) and RESFEN model calculations. This report includes a summary of the results, NEAT and RESFEN background, methodology, and input assumptions, and an appendix with detailed results and assumptions by cliamte zone.

energy savings, windows↗

IN2 Profile: Polyceed Electrochromic Window Technology Expected to Lower Energy Costs

Through the Wells Fargo Innovation Incubator (IN²) program, Polyceed will validate their electrochromic window technology. The technology is expected to provide customers with 75% lower cost than conventional dynamic windows and offer small residences $200 a year of cost savings for energy consumption. The IN² program launched in October 2014 and is part of Wells Fargo’s 2020 Environmental Commitment to provide $100 million to environmentally-focused nonprofits and universities. The goal is to create an ecosystem that fosters and accelerates the commercialization of promising commercial buildings technologies that can provide scalable solutions to reduce the energy impact of buildings. According to the Department of Energy, nearly 40 percent of energy consumption in the U.S. today comes from buildings at an estimated cost of $413 billion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon-encapsulated niobium carbonitride with high volumetric capacitance and wide potential windows in aqueous pseudocapacitors

Electrochemical capacitors deliver high power and have long operational lives; yet, their energy densities are limited. Compared to carbon-based electrical double-layer capacitors, pseudocapacitors with an aqueous electrolyte are predicated to provide both high gravimetric and volumetric capacitance while being cost-effective and eco-friendly. However, their narrow operational potential windows limit the practical delivery of energy. In this study, we synthesized novel NbCxN1-x nanoparticles encapsulated in a uniform carbon layer. This pseudocapacitive material exhibits a high volumetric capacitance, a wide potential window stability (~345 F cm –3 , 2.1 V, in 1 M of Li 2 SO 4 ), and a long cycling life (>10 000 cycles). Moreover, the symmetric cells (2.2 V, in 1 M of Li 2 SO 4 ) exhibit high energy density as well as excellent cyclability and rate performances. These results offer new chances for the design of aqueous energy storage devices having a wide applied potential difference and excellent performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control algorithms for dynamic windows for residential buildings

This study analyzes the influence of control algorithms for dynamic windows on energy consumption, number of hours of retracted shades during daylight and shade operations. Five different control algorithms - heating/cooling, simple rules, perfect citizen, heat flow and predictive weather were developed and compared. The performance of a typical residential building was modeled with EnergyPlus. The program Widow was used to generate a Bi-Directional Distribution Function (BSDF) for two window configurations. The BSDF was exported to EnergyPlus using the IDF file format. The EMS feature in EnergyPlus was used to develop custom control algorithms. The calculations were made for four locations with diverse climate. The results showed that: (a) use of automated shading with proposed control algorithms can reduce the site energy in the range of 11.6-13.0%; in regard to source (primary) energy in the range of 20.1-21.6%, (b) the differences between algorithms in regard to energy savings are not high, (c) the differences between algorithms in regard to number of hours of retracted shades are visible, (e) the control algorithms have a strong influence on shade operation and oscillation of shade can occur, (d) additional energy consumption caused by motor, sensors and a small microprocessor in the analyzed case is very small.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Selective Acetylene Semihydrogenation Catalyst with an Operation Window Exceeding 150 °C

The operating window (OW) is a primary performance criterion for the selective hydrogenation of acetylene in excess ethylene. Currently, most state-of-the-art catalyst systems have an OW of less than 50 °C in front-end processes. Selective acetylene hydrogenation catalysts with an OW wider than 100 °C are rare. Here, we demonstrate a facile stepwise chemical method to synthesize calcite-supported PdBi intermetallic compounds (PdBi/Calcite) that feature isolated and electron-rich Pd atoms as active sites for acetylene hydrogenation. Beneficial from the extremely weak ethylene absorption abilities and the stable structures against the formation of β-PdH x , PdBi/Calcite exhibit >99% selectivity to C 2 H 4 in the whole temperature range tested (50–300 °C) and ~100% C 2 H 2 conversion from 150 to 300 °C. Finally, as a result, an operation window exceeding 150 °C has been achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Impact Of The MCU Life Extension Solvent On Sludge Batch 8 Projected Operating Windows

As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NGS) and a new strip acid will be deployed. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing or evaluations with the next generation solvent are required to determine the impact of these changes (if any) to Chemical Process Cell (CPC) activities, glass formulation strategies, and melter operations at the Defense Waste Processing Facility (DWPF). The introduction of the dilute (0.01 M) boric acid stream into the DWPF flowsheet has a potential impact on glass formulation and frit development efforts since B 2 O 3 is a major oxide in frits developed for DWPF. Prior knowledge of this stream can be accounted for during frit development efforts but that was not the case for Sludge Batch 8 (SB8). Frit 803 has already been recommended and procured for SB8 processing; altering the frit to account for the incoming boron from the strip effluent (SE) is not an option for SB8. Therefore, the operational robustness of Frit 803 to the introduction of SE including its compositional tolerances (i.e., up to 0.0125M boric acid) is of interest and was the focus of this study. The primary question to be addressed in the current study was: What is the impact (if any) on the projected operating windows for the Frit 803 - SB8 flowsheet to additions of B 2 O 3 from the SE in the Sludge Receipt and Adjustment Tank (SRAT)? More specifically, will Frit 803 be robust to the potential compositional changes occurring in the SRAT due to sludge variation, varying additions of ARP and/or the introduction of SE by providing access to waste loadings (WLs) of interest to DWPF? The Measurement Acceptability Region (MAR) results indicate there is very little, if any, impact on the projected operating windows for the Frit 803 - SB8 system regardless of the presence or absence of ARP and SE (up to 2 wt% B 2 O 3 contained in the SRAT and up to 2000 gallons of ARP). It should be noted that 0.95 wt% B 2 O 3 is the nominal projected concentration in the SRAT based on a 0.0125M boric acid flowsheet with 70,000 liters of SE being added to the SRAT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Windows and Building Envelope Research and Development: A Roadmap for Emerging Technologies

This Building Technologies Office (BTO) Research and Development (R&D) Roadmap identifies priority windows and building envelope R&D areas of interest. Cost and performance targets are identified for each key R&D area. The roadmap describes the technical and market challenges to be overcome, R&D activities and milestones, key stakeholders, and potential energy savings that could result if cost and performance targets are met. Methods for improving technology performance and specific strategies for reducing installed costs and mitigating any other market barriers, which would increase the likelihood of mass-market technology adoption, are identified. This roadmap is a useful resource for public and private decision makers evaluating and pursuing high-impact R&D focused on advancing next-generation energy efficient windows and building envelope technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvements of SCALE Infrastructure on Microsoft Windows [Slides]

This presentation is on improvements of SCALE infrastructure on Microsoft Windows. This presentation begins with an overview and history of the group and history of SCALE infrastructure and testing as well. Improvements made to testing and the introduction of the cloud is brought up. Other topics include: GitLab Testing Suite and Windows Toolchain. Benefits to testing, to developers, and to users are discussed.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Optimization of Window Positions for Wind-Driven Natural Ventilation Performance

This paper optimizes opening positions on building facades to maximize the natural ventilation’s potential for ventilation and cooling purposes. The paper demonstrates how to apply computational fluid dynamics (CFD) simulation results to architectural design processes, and how the CFD-driven decisions impact ventilation and cooling: (1) background: A CFD helps predict the natural ventilation’s potential, the integration of CFD results into design decision-making has not been actively practiced; (2) methods: Pressure data on building facades were obtained from CFD simulations and mapped into the 3D modeling environment, which were then used to identify optimal positions of two openings of a zone. The effect of the selected opening positions was validated with building energy simulations; (3) results: The cross-comparison study of different window positions based on different geographical locations quantified the impact on natural ventilation effectiveness; and (4) conclusions: The optimized window position was shown to be effective, and some optimal solutions contradicted the typical cross-ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Launch Window Trade Analysis for the James Webb Space Telescope

The James Webb Space Telescope (JWST) is a large-scale space telescope mission designed to study fundamental astrophysical questions ranging from the formation of the universe to the origin of planetary systems and the origins of life. JWSTs orbit design is a Libration Point Orbit (LPO) around the Sun-Earth/Moon (SEM) L2 point for a planned mission lifetime of 10.5 years. The launch readiness period for JWST is from Oct 1st, 2018 November 30th, 2018. This paper presents the first launch window analysis for the JWST observatory using finite-burn modeling; previous analysis assumed a single impulsive midcourse correction to achieve the mission orbit. The physical limitations of the JWST hardware stemming primarily from propulsion, communication and thermal requirements alongside updated mission design requirements result in significant launch window within the launch readiness period. Future plans are also discussed.

window↗

WINDOW-WALL INTERFACE CORRECTION FACTORS: THERMAL MODELING OF INTEGRATED FENESTRATION AND OPAQUE ENVELOPE SYSTEMS FOR IMPROVED PREDICTION OF ENERGY USE

The boundary conditions for thermal modeling of fenestration systems assume an adiabatic condition between the fenestration system installed and the opaque envelope system. This theoretical adiabatic boundary condition may not be appropriate owing to heat transfer at the interfaces, particularly for aluminum- framed windows affixed to metal- framed walls. In such scenarios, the heat transfer at the interface may increase the discrepancy between real world thermal indices and laboratory measured or calculated indices based on NFRC Rating System.This paper discusses the development of window-wall Interface Correction Factors (ICF) to improve energy impacts of building envelope systems

99 GENERAL AND MISCELLANEOUS↗

Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort

A simulation study was conducted to evaluate lighting energy savings of split-pane electrochromic (EC) windows controlled to satisfy key visual comfort parameters. Using the Radiance lighting simulation software, interior illuminance and luminance levels were computed for a south-facing private office illuminated by a window split into two independently-controlled EC panes. The transmittance of these was optimized hourly for a workplane illuminance target while meeting visual comfort constraints, using a least-squares algorithm with linear inequality constraints. Blinds were successively deployed until visual comfort criteria were satisfied. The energy performance of electrochromics proved to be highly dependent on how blinds were controlled. With hourly blind position adjustments, electrochromics showed significantly higher (62percent and 53percent, respectively without and with overhang) lighting energy consumption than clear glass. With a control algorithm designed to better approximate realistic manual control by an occupant, electrochromics achieved significant savings (48percent and 37percent, respectively without and with overhang). In all cases, energy consumption decreased when the workplace illuminance target was increased. In addition, the fraction of time during which the occupant had an unobstructed view of the outside was significantly greater with electrochromics: 10 months out of the year versus a handful of days for the reference case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimization of CdTe thin‐film solar cell efficiency using a sputtered, oxygenated CdS window layer

Abstract A major source of loss in cadmium sulfide/cadmium telluride (CdS/CdTe) solar cells results from light absorbed in the CdS window layer, which is not converted to electrical current. This film can be made more transparent by oxygen incorporation during sputter deposition at ambient temperature. Prior to this work, this material has not produced high‐efficiency devices on tin oxide‐coated soda‐lime‐glass substrates used industrially. Numerous devices were fabricated over a variety of process conditions to produce an optimized device. Although the material does not show a consistent increase in band gap with oxygenation, absorption in this layer can be virtually eliminated over the relevant spectrum, leading to an increase in short‐circuit current. Meanwhile, fill factor is maintained, and open‐circuit voltage increases relative to baseline devices with sublimated CdS. The trend of device parameters with oxygenation and thickness is consistent with an increasing conduction band offset at the window/CdTe interface. Optimization considering both initial efficiency and stability resulted in a National Renewable Energy Laboratory verified 15.2%‐efficient cell on 3.2‐mm soda‐lime glass. This window material was shown to be compatible with SnO 2 ‐based transparent conducting oxide and high resistance transparent coated substrates using in‐line compatible processes. Copyright © 2015 John Wiley & Sons, Ltd

Kephart, Jason M.↗

Broken conformal window

We show that near the edges of the conformal window of supersymmetric SU(Nc) QCD, perturbed by Anomaly Mediated Supersymmetry Breaking (AMSB), chiral symmetry can be broken depending on the initial conditions of the RG flow. We do so by perturbatively expanding around Banks-Zaks fixed points and taking advantage of Seiberg duality. Interpolating between the edges of the conformal window, we predict that non-supersymmetric QCD breaks chiral symmetry up to N f ≤ 3N c − 1, while we cannot say anything definitive for N f ≥ 3N c at this moment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Method to Alleviate the Long History Problem Encountered in Monte Carlo Simulations via Weight Window Variance Reduction

When the weight window is implemented in large and complex models, streaming path and deep penetration could lead to a long history problem that takes a disproportionate amount of time for the accomplishment of Monte Carlo simulations and exerts a detrimental effect on the efficiency of parallel computing. An approach set the limitation of weight window splitting was proposed for the alleviation of long history problem. Tests were conducted on a streaming dog-leg geometry model and a 3D model of the Chinese Fusion Engineering Testing Reactor. The results show that a suitable parameter in the alleviation method could optimize both the performance of variance reduction and the efficiency of parallel calculation, which makes long history problem tractable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗