Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Strategy for Advancing Earth Independent Medical Operations

Exploration medical operations to the Moon and Mars present unprecedented challenges for providing in-mission medical care. The greater distance from Earth is the primary hazard that drives the need for a medical operations paradigm shift from low earth orbit mission. Increasingly complex long duration and long distance missions will have resource constraints (ex: mass, power, volume, data), a paucity of resupply or evacuation opportunities, and disruptions in real-time communications. In order to advance a more autonomous medical approach, a multi-faceted strategy will need to optimize all aspects of human health and performance in space. This strategy will include: increasing onboard medical autonomy through the development of novel crew health and performance systems; decision support capabilities to augment astronauts’ abilities in preventing, diagnosing, and treating medical conditions; creating new procedures and training tools for skill maintenance and just-in-time training; and enabling rapid crew access to data from all on-board systems, leading to better-informed, real-time, autonomous decisions. Collectively, this approach can be referred to as “Earth Independent Medical Operations” (EIMO). The Exploration Medical Capability Element of NASA’s Human Research Program has undertaken a longitudinal planning process to consensus around EIMO. Technical interchange meetings will occur with key constituents in late 2022 and again in early 2023 to define EIMO in practical terms and identify key elements of an EIMO system, with greater conceptual articulation and dissemination planned for the second half of 2023. We will share insights into the strategy for internal and external consensus building around EIMO, with a particular focus on the approach to partner stakeholders within NASA as well as commercial agencies.

Jay Lemery↗

Volumetric Limits for Carry in a Spacesuit

Though there is a plethora of ergonomic guidelines for manual material handling, including maximum weight limits, there is not much guidance for the largest size of an object that a person can carry. Moreover, given the new Artemis space program’s intent to reestablish and maintain human presence on the Moon, there is a need to set manual material handling requirements for the partial gravity environment. Lunar surface carry limits while wearing a pressurized spacesuit is chief among them. Specifically, volumetric limits are required to determine the maximum dimensions of an item that a crewmember will be able to carry on the lunar surface. This study will assess spacesuit motion data to determine acceptable locations where the hand can be positioned for carrying an object, as hand position will vary with the crewmember anthropometry, spacesuits constraints and mechanism. Maximum volume limits will be derived from clearances between the suit and the gloved hand. The mobility of the suit and task contexts (e.g., terrain types, ground clearance) will also be taken into consideration to ensure that the volume being carried does not interfere with suit hardware or impart any mobility restrictions. The specific analysis methods and outcomes will be detailed in the final proceeding. The outcome of this study is expected to provide guidelines for maximum volumes that can be carried both two-handed and one-handed while wearing a spacesuit.

Y. Hernandez↗

Integration of Advanced Structures and Materials Technologies for a Robust Lunar Habitat

NASA’s Artemis program plans to have a sustainable lunar base deployed on the Moon by 2028. The base calls for a foundation surface habitat that can support a crew of four members for a minimum mission duration of 28-days. The lack of a magnetic field and significant lunar atmosphere extends the lifetime of secondary radiation emitted from metallic structures, which is a health hazard for exposed astronauts. Integration of non-metallic structural materials into surface habitat design may alleviate some of these concerns. Additionally, it is favorable for the structure to be collapsible for transportation to optimize payload volume, mass efficiency, and monetary constraints. As a result, inflatable structures are being investigated due to their improved packing efficiency at launch, optimal mass-to-volume ratio, and large surface area that can efficiently disperse structural loads and heat. Currently, only two inflatable airlocks have been deployed in space. Thus, there is a significant need to advance technologies associated with inflatable structures to provide greater options for future missions, i.e., Artemis and beyond. This study focused on the inflatable lunar habitat applications of emerging NASA Langley Research Center (LaRC) technologies and their required development steps to become space qualified. The Bowling Habitat architecture was generated from 13 of these NASA LaRC technologies, five of which were deemed critical, five determined as enhancing technologies, and three were classified as transformational technologies for the Artemis program. To address the payload constraints, the study also considered a tentative timeline that aligned with the current Artemis schedule for transporting the Bowling Habitat to the Moon. Ultimately, the Bowling Habitat mainly addressed the structural needs of an inflatable lunar habitat, meaning that major areas pertaining to the life-style aspects of the habitat must be improved. Areas include, but are not limited to, hard connection points, the monitoring of human health, and extra radiation protection for solar proton events.

Inflatable Habitat↗

Conceptual Design Optimization of an Augmented Stability Aircraft Incorporating Dynamic Response and Actuator Constraints

Empirical sizing guidelines such as tail volume coefficients have long been used in the early aircraft design phases for sizing stabilizers, resulting in conservatively stable aircraft. While successful, this results in increased empty weight, reduced performance, and greater procurement and operational cost relative to an aircraft with optimally sized surfaces. Including flight dynamics in the conceptual design process allows the design to move away from empirical methods while implementing modern control techniques. A challenge of flight dynamics and control is the numerous design variables, which are changing fluidly throughout the conceptual design process, required to evaluate the system response to some disturbance. This research focuses on addressing that challenge not by implementing higher order tools, such as computational fluid dynamics, but instead by linking the lower order tools typically used within the conceptual design process so each discipline feeds into the other. In thisresearch, flight dynamics and control was incorporated into the conceptual design process along with the traditional disciplines of vehicle sizing, weight estimation, aerodynamics, and performance. For the controller, a linear quadratic regulator structure with constant gains has been specified to reduce the user input. Coupling all the disciplines in the conceptual design phase allows the aircraft designer to explore larger design spaces where stabilizers are sized according to dynamic response constraints rather than historical static margin and volume coefficient guidelines.

Welstead, Jason↗

Optimum vibrating beams with stress and deflection constraints

The fundamental frequency of vibration of an Euler-Bernoulli or a Timoshenko beam of a specified constant volume is maximized subject to the constraint that under a prescribed loading the maximum stress or maximum deflection at any point along the beam axis will not exceed a specified value. In contrast with the inequality constraint which controls the minimum cross-section, the present inequality constraints lead to more meaningful designs. The inequality constraint on stresses is as easily implemented as the minimum cross-section constraint but the inequality constraint on deflection uses a treatment which is an extension of the matrix partitioning technique of prescribing displacements in finite element analysis.

Kamat, M. P.↗

A Brownian dynamics study on ferrofluid colloidal dispersions using an iterative constraint method to satisfy Maxwell’s equations

Ferrofluids are often favored for their ability to be remotely positioned via external magnetic fields. The behavior of particles in ferromagnetic clusters under uniformly applied magnetic fields has been computationally simulated using the Brownian dynamics, Stokesian dynamics, and Monte Carlo methods. However, few methods have been established that effectively handle the basic principles of magnetic materials, namely, Maxwell’s equations. An iterative constraint method was developed to satisfy Maxwell’s equations when a uniform magnetic field is imposed on ferrofluids in a heterogeneous Brownian dynamics simulation that examines the impact of ferromagnetic clusters in a mesoscale particle collection. This was accomplished by allowing a particulate system in a simple shear flow to advance by a time step under a uniformly applied magnetic field, then adjusting the ferroparticles via an iterative constraint method applied over sub-volume length scales until Maxwell’s equations were satisfied. The resultant ferrofluid model with constraints demonstrates that the magnetoviscosity contribution is not as substantial when compared to homogeneous simulations that assume the material’s magnetism is a direct response to the external magnetic field. This was detected across varying intensities of particle-particle interaction, Brownian motion, and shear flow. Ferroparticle aggregation was still extensively present but less so than typically observed.

42 ENGINEERING↗

Volume modulus inflation and the gravitino mass problem

The Hubble constant during the last stages of inflation in a broad class of models based on the Kachru-Kallosh-Linde-Trivedi mechanism should be smaller than the gravitino mass, H{approx}<m{sub 3/2}. We point out that in the models with large volume of compactification the corresponding constraint typically is even stronger, H{approx}<m{sub 3/2}{sup 3/2}, in Planck units. In order to address this problem, we propose a class of models with large volume of compactification where inflation may occur exponentially far away from the present vacuum state. In these models, the Hubble constant during inflation can be many orders of magnitude greater than the gravitino mass. We introduce a toy model describing this scenario, and discuss its strengths and weaknesses.

79 ASTRONOMY AND ASTROPHYSICS↗

Tumor response parameters for head and neck cancer derived from tumor-volume variation during radiation therapy

Purpose: The main goal of this paper is to reconstruct a distribution of cell survival fractions from tumor-volume variation for a heterogeneous group of head and neck cancer patients and compare this distribution to the data from predictive assays. Methods: To characterize the tumor-volume variation during radiation therapy treatment, the authors use a two-level tumor-volume model of cell population that separates the entire tumor cell population into two subpopulations of viable cells and lethally damaged cells. This parameterized radiobiological model is integrated with a least squares objective function and a simulated annealing optimization algorithm to describe time-dependent tumor-volume variation rates in individual patients. Several constraints have been used in the optimization problem because tumor-volume variation during radiotherapy is described by a sum of exponentials; therefore, the problem of accurately fitting a model to measured data is ill-posed. The model was applied to measured tumor-volume variation curves from a clinical study on tumor-volume variation during radiotherapy for 14 head and neck cancer patients in which an integrated CT/linear particle accelerator (LINAC) system was used for tumor-volume measurements. Results: The two-level cell population tumor-volume modeling is capable of describing tumor-volume variation throughout the entire treatment for 11 of the 14 patients. For three patients, the tumor-volume variation was described only during the initial part of treatment, a fact that may be related to the neglected hypoxia in the two-level approximation. The predicted probability density distribution for the survival fractions agrees with the data obtained using in vitro studies with predictive assays. The mean value 0.35 of survival fraction obtained in this study is larger than the value 0.32 from in vitro studies, which could be expected because of greater repair in vivo. The mean half-life obtained in this study for the head-and-neck squamous cell carcinoma (SCC) is equal to 3.8 mean potential doubling times, which agrees with 4.0 mean potential doubling times obtained previously for lung SCC. Conclusions: The distribution of cell survival fractions obtained in this study support the hypothesis that the tumor-volume variation during radiotherapy treatment for head and neck cancer can be described by the two-level cell population tumor-volume model. This model can be used for in vivo evaluation of patient-specific radiobiological parameters that are needed for tumor-control probability evaluation.

60 APPLIED LIFE SCIENCES↗

Urban Air Mobility (UAM) Market Study

The Booz Allen Team explored market size and potential barriers to Urban Air Mobility (UAM) by focusing on three potential markets – Airport Shuttle, Air Taxi, and Air Ambulance. We found that the Airport Shuttle and Air Taxi markets are viable, with a significant total available market value in the U.S. of $500 billion, for a fully unconstrained scenario. In this unconstrained best-case scenario, passengers would have the ability to access and fly a UAM at any time, from any location to any destination, without being hindered by constraints such as weather, infrastructure, or traffic volume. Significant legal and regulatory, weather, certification, public perception, and infrastructure constraints exist, which reduce the market potential for these applications to only about 0.5% of the total available market, or $2.5 billion, in the near term. However, we determined that these constraints can be addressed through ongoing intra-governmental partnerships, government and industry collaboration, strong industry commitment, and existing legal and regulatory enablers. We found that the Air Ambulance market is not a viable market if served by electric vertical takeoff and landing (eVTOL) vehicles due to technology constraints but may potentially be viable if a hybrid VTOL aircraft are utilized. The barriers and challenges we characterized in this study can be stratified according to their applicability or potential mitigation through technology as well as market maturity (Figure 1). In the near term, high cost of service will be a key economic challenge. We found potential for significant reduction in service cost through increased vehicle and component efficiency, and automation in a more mature market scenario. Weather conditions also pose a challenge to the UAM market, though there is potential for mitigation of some of these impacts through technology such as sensors enabling operations in low visibility. However, even in a mature market with advanced technology, disruptions are still likely to occur due to weather events such as thunderstorms and strong winds. High density operations will likely stress the current Air Traffic Management (ATM) system in the near term, but technology and new initiatives such as the Air Traffic Management -eXploration project (ATM-X) will enable safe and efficient integration of UAM into the National Airspace System (NAS). Current battery technology creates a barrier in the near term, especially for the Air Ambulance market, as battery weight and extensive recharging times would be needed for these operations. Advancements in battery technology, as well as use of hybrid VTOLs, could significantly reduce this barrier in the longer term. As UAM emerges as a viable mode of transportation in the near term, adverse energy and environmental impacts, particularly noise, may impact community acceptance and potentially persist as the market matures into larger-scale operations. For non-technology related challenges, we found that infrastructure constraints will create a significant barrier to UAM in the near term but could be addressed in the longer term through development and expansion of vertiports. Competition from existing modes of transportation such as ride-sharing (e.g., Lyft, Uber) and ground taxi’s pose a key barrier to UAM in the short term, which will likely evolve into competition from other emerging technologies such as autonomous cars and electric trains in the longer term. Weather events will influence other components of the operation such as passenger comfort (e.g., extreme temperatures, turbulence) and infrastructure (e.g., winter weather causing cracks and degradation in vertiports). There is also potential for these impacts to be heightened in the longer term from the increased frequency of adverse weather such as thunderstorms due to changing climatic conditions. We also found that the public has strong concerns about safety as a passenger in a piloted UAM, including “lasing” of pilots, unruly passengers, and sabotage. They would prefer that all passengers pass through a security screening process before boarding a vehicle. They would also prefer to use UAM for longer regional trips, such as flying from Washington, DC to Baltimore, MD or San Diego, CA to Los Angeles, CA. A longer term automated UAM vehicle market will face challenges due to public apprehension about automation and unmanned operations, and a preference to fly with passengers they know in an autonomous (unmanned) operational scenario.

Rohit Goyal↗

Obtaining Normal Tissue Constraints Using Intensity Modulated Radiotherapy (IMRT) in Patients with Oral Cavity, Oropharnygeal, and Laryngeal Carcinoma

The purpose of this study was to evaluate normal tissue dose constraints while maintaining planning target volume (PTV) prescription without reducing PTV margins. Sixteen patients with oral cavity carcinoma (group I), 27 patients with oropharyngeal carcinoma (group II), and 28 patients with laryngeal carcinoma (group III) were reviewed. Parotid constraints were a mean dose to either parotid < 26 Gy (PP1), 50% of either parotid < 30 Gy (PP2), or 20 cc of total parotid < 20 Gy (PP3). Treatment was intensity modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB). All patients met constraints for cord and brain stem. The mandibular constraints were met in 66%, 29%, and 57% of patients with oral, oropharyngeal, and laryngeal cancers, respectively. Mean dose of 26 Gy (PP1) was achieved in 44%, 41%, and 38% of oral, oropharyngeal, and laryngeal patients. PP2 (parotid constraint of 30 Gy to less than 50% of one parotid) was the easiest to achieve (group I, II, and III: 82%, 76%, and 78%, respectively). PP3 (20 cc of total parotid < 20 Gy) was difficult, and was achieved in 25%, 17%, and 35% of oral, oropharyngeal, and laryngeal patients, respectively. Mean parotid dose of 26 Gy was met 40% of the time. However, a combination of constraints allowed for sparing of the parotid based on different criteria and was met in high numbers. This was accomplished without reducing PTV-parotid overlap. What dose constraint best correlates with subjective and objective functional outcomes remains a focus for future study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Systems and Photosystems: Cellular Limits of Autotrophic Productivity in Cyanobacteria

Recent advances in the modeling of microbial growth and metabolism have shown that growth rate critically depends upon the optimal allocation of finite proteomic resources among different cellular functions and that modeling growth rates becomes more realistic with the explicit accounting for the costs of macromolecular synthesis, most importantly, protein expression. The “proteomic constraint” is considered together with its application to understanding photosynthetic microbial growth. The central hypothesis is that physical limits of cellular space (and corresponding solvation capacity) in conjunction with cell surface-to-volume ratios represent the underlying constraints on the maximal rate of autotrophic microbial growth. The limitation of cellular space thus constrains the size the total complement of macromolecules, dissolved ions, and metabolites. To a first approximation, the upper limit in the cellular amount of the total proteome is bounded this space limit. This predicts that adaptation to osmotic stress will result in lower maximal growth rates due to decreased cellular concentrations of core metabolic proteins necessary for cell growth owing the accumulation of compatible osmolytes, as surmised previously. The finite capacity of membrane and cytoplasmic space also leads to the hypothesis that the species-specific differences in maximal growth rates likely reflect differences in the allocation of space to niche-specific proteins with the corresponding diminution of space devoted to other functions including proteins of core autotrophic metabolism, which drive cell reproduction. An optimization model for autotrophic microbial growth, the autotrophic replicator model, was developed based upon previous work investigating heterotrophic growth. The present model describes autotrophic growth in terms of the allocation protein resources among core functional groups including the photosynthetic electron transport chain, light-harvesting antennae, and the ribosome groups.

59 BASIC BIOLOGICAL SCIENCES↗

Dual Fan Separator within the Universal Waste Management System

Since NASA's new spacecraft in development for both LEO and Deep Space capability have considerable crew volume reduction in comparison to the Space Shuttle, it is clear that NASA requires a smaller and less expensive commode. The UTAS Universal Waste Management System (UWMS) was designed to address these new constraints, resulting in an 80% volume reduction in the cabin while enhancing performance. Whereas all of the current space commodes use air flow to capture both urine and feces and separate air from the captured air/urine mixture, the UWMS commode and urine fans and the urine separator were combined into a single unit. This unit enables use of a single motor and motor controller, which provides considerable packaging and weight efficiency. In some of the intended platform applications for the UWMS, the urine is pumped to a water reclamation system. The ISS Urine Processor Assembly (UPA) system requires delivered urine to include less than 0.25% air inclusion. Air inclusion in centrifugal urine separators is greatly dependent on its rotational speed. To satisfy this requirement, a gear reducer was included, allowing the fans to rotate at a much higher speed than the separator. This new design, the Dual Fan Separator (DFS) has been designed, prototyped and tested. This paper will outline the studies and analysis performed to develop the design configuration for testing. The studies included a configuration trade study, dynamic stability analysis of the rotating bodies and a performance analysis of included labyrinth seals. NASA is considereing a program to fly the UWMS aboard the ISS as a flight experiment. The goal of the design activity is to elevate the Technical Readiness Level (TRL) of the Dual Fan Separator and determine if the concept is ready to be included in flight experiment deliverable.

Stapleton, Tom↗

High-speed real-time 3D shape measurement based on adaptive depth constraint

Stereo phase unwrapping (SPU) has been increasingly applied to high-speed real-time fringe projection profilometry (FPP) because it can retrieve the absolute phase or matching points in a stereo FPP system without projecting or acquiring additional fringe patterns. Based on a pre-defined measurement volume, artificial maximum/minimum phase maps can be created solely using geometric constraints of the FPP system, permitting phase unwrapping on a pixel-by-pixel basis. However, when high-frequency fringes are used, the phase ambiguities will increase which makes SPU unreliable. Several auxiliary techniques have been proposed to enhance the robustness of SPU, but their flexibility still needs to be improved. In this paper, we proposed an adaptive depth constraint (ADC) approach for high-speed real-time 3D shape measurement, where the measurement depth volume for geometric constraints is adaptively updated according to the current reconstructed geometry. By utilizing the spatio-temporal correlation of moving objects under measurement, a customized and tighter depth constraint can be defined, which helps enhance the robustness of SPU over a large measurement volume. Besides, two complementary techniques, including simplified left-right consistency check and feedback mechanism based on valid area, are introduced to further increase the robustness and flexibility of the ADC. Furthermore, experimental results demonstrate the success of our proposed SPU approach in recovering absolute 3D geometries of both simple and complicated objects with only three phase-shifted fringe images.

42 ENGINEERING↗

$L^1$ penalization of volumetric dose objectives in optimal control of PDEs

This work is concerned with a class of PDE-constrained optimization problems that are motivated by an application in radiotherapy treatment planning. Here the primary design objective is to minimize the volume where a functional of the state violates a prescribed level, but prescribing these levels in the form of pointwise state constraints leads to infeasible problems. We therefore propose an alternative approach based on L 1 penalization of the violation that is also applicable when state constraints are infeasible. We establish well-posedness of the corresponding optimal control problem, derive first-order optimality conditions, discuss convergence of minimizers as the penalty parameter tends to infinity, and present a semismooth Newton method for their efficient numerical solution. Finally, the performance of this method for a model problem is illustrated and contrasted with an alternative approach based on (regularized) state constraints.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-195: Systematic Constraining of Contralateral Parotid Gland Led to Improved Dosimetric Outcomes for Multi-Field Optimization with Scanning Beam Proton Therapy: Promising Results From a Pilot Study in Patients with Base of Tongue Carcinoma

Purpose: Treatment planning for Intensity Modulated Proton Therapy (IMPT) for head and neck cancer is time-consuming due to the large number of organs-at-risk (OAR) to be considered. As there are many competing objectives and also wide range of acceptable OAR constraints, the final approved plan may not be most optimal for the given structures. We evaluated the dose reduction to the contralateral parotid by implementing standardized constraints during optimization for scanning beam proton therapy planning. Methods: Twenty-four (24) consecutive patients previously treated for base of tongue carcinoma were retrospectively selected. The doses were 70Gy, 63Gy and 57Gy (SIB in 33 fractions) for high-, intermediate-, and standard-risk clinical target volumes (CTV), respectively; the treatment included bilateral neck. Scanning beams using MFO with standardized bilateral anterior oblique and PA fields were applied. New plans where then developed and optimized by employing additional contralateral parotid constraints at multiple defined dose levels. Using a step-wise iterative process, the volume-based constraints at each level were then further reduced until known target coverages were compromised. The newly developed plans were then compared to the original clinically approved plans using paired student t-testing. Results: All 24 newly optimized treatment plans maintained initial plan quality as compared to the approved plans, and the 98% prescription dose coverage to the CTV’s were not compromised. Representative DVH comparison is shown in FIGURE 1. The contralateral parotid doses were reduced at all levels of interest when systematic constraints were applied to V10, V20, V30 and V40Gy (All P<0.0001; TABLE 1). Overall, the mean contralateral parotid doses were reduced by 2.26 Gy on average, a ∼13% relative improvement. Conclusion: Applying systematic and volume-based contralateral parotid constraints for IMPT planning significantly reduced the dose at all dosimetric levels for patients with base of tongue cancer.

60 APPLIED LIFE SCIENCES↗

Gromov ground state in phase space engineering for fusion energy

Phase space engineering by rf waves plays important roles in both thermal D-T fusion and nonthermal advanced fuel fusion, but not all phase space manipulation is allowed; certain fundamental limits exist. In addition to Liouville's theorem, which requires the manipulation to be volume preserving, Gromov's nonsqueezing theorem imposes another constraint. Here, the Gardner ground state is defined as the ground state accessible by smooth volume-preserving maps. However, the extra Gromov constraint should produce a higher-energy ground state. An example of a Gardner ground state forbidden by Gromov's nonsqueezing theorem is given. The challenge question is “What is the Gromov ground state, i.e., the lowest energy state accessible by smooth symplectic maps?” This is a difficult problem. As a simplification, we conjecture that the linear Gromov ground state problem is solvable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comparison of Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Frontal and Temporal High-Grade Gliomas

Purpose: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). Methods and Materials: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. Results: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +- 112 and VMAT = 363 +- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +- 0.4 and VMAT = 1.8 +- 0.1 (relative reduction 65%, p = 0.002). Conclusions: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗