Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

EMU Ventilation Loop Simulation and Assessment of Contamination of the EMU Sublimator Hydrophilic Coating

Controlling moisture is a critical function performed in the space suit during extra vehicular activity (EVA) missions. Currently, this function is carried out by a sublimator, which is coated with a hydrophilic material. Tests have shown that siloxane compounds can off gas from the helmet absorption pad extension (HAP-E) and helmet absorption band (HAB) when they are at elevated temperatures and initial testing indicated that siloxanes could damage the hydrophilic coating. Therefore, more representative testing was needed. Important test considerations were source and destination kinetics, system geometries, scrubbing efficacy by the activated charcoal from the Metox canister, and other benefits that derive from active condensation occurring on the hydrophilic coating during exposure. A ventilation loop that was originally constructed to test hardware for control of CO2 and trace contaminants under EVA conditions was modified to conduct the siloxane off gassing tests. A vacuum compatible acrylic chamber was installed to simulate the suit volume. A steel beaker located in the chamber contained the HAP-E and HAB materials and was heated with two band heaters. The flow exiting the chamber passed through a LiOH cannister, which contained carbon beds to simulate their function in the Metox. The flow then was directed into a smaller volume that contained a coupon, which was coated with the hydrophilic material and was maintained at 10°C (50°F). Moisture was injected upstream of the suit volume simulator to maintain the dew point between 12.7°C (55°F) and 18.3°C (65°F). The pressure was controlled to between 3.8 and 4.4 psia, and the flow was held at 6 acfm. The system was run for an equivalent of 25 ten-hour EVAs, where the HAP-E/HAB materials were changed out after each EVA. The effect of the potential off gassing on the coupon was measured after each EVA period.

PLSS↗

Non-Invasive Ventilation Evaluation for Exploration Missions

This session will review the evidence supporting the use of non-invasive ventilation (NIV) for acute respiratory failure and will evaluate the validity and viability of using various modalities of NIV within the mass and volume constraints of exploration missions.

Aaliya Burza↗

Aerodynamic and Acoustic Performance Testing of Metal Spacecraft Cabin Ventilation Fan

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements included were: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. The present report documents the test setup. A series of follow on reports documents the results. These fan units, the data and the test facility described herein are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Small Fan Noise↗

Quiet Spacecraft Cabin Ventilation Fan: Acoustic Measurements Results

A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the acoustic measurements as part of a series of reports.

o Small Fan Noise, Testing, Duct Modes↗

Quiet Spacecraft Cabin Ventilation Fan: Aerodynamic Measurements Results

A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the aerodynamic measurements as part of a series of reports.

Small Fan Noise,↗

Quiet Spacecraft Cabin Ventilation Fan: Acoustic Measurements Results

A quiet spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the acoustic measurements as part of a series of reports.

Small Fan Noise↗

Quiet Spacecraft Cabin Ventilation Fan: Aerodynamic Measurements Results

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the aerodynamic measurements as part of a series of reports.

o Small Fan Noise, Testing, Duct Modes↗

Gateway Integrated ECLSS Model Analysis of Intermodule Ventilation Failures

The Gateway Integrated ECLSS Model (GIEM) is a set of two independent models, made in Aspen Custom Modeler (ACM) and Thermal Desktop (TD), of the Gateway stack and each modules' associated environment control and life support system (ECLSS). The GIEM utilizes the 41-Node Metabolic Man (METMAN) to simulate crew inside the Gateway consuming O2 and producing CO2, H2O, and heat for the ECLSS to remove. The modules and visiting vehicles all have different levels of ECLSS capabilities and may rely on other modules and Intermodular Ventilation (IMV), which is used to exchange gas between the modules, to ensure the entire Gateway environment is controlled. If IMV were to fail or be turned off, some vehicles may have limited access to necessary ECLSS functions. This analysis focuses on evaluating O2, CO2, and H2O levels when crew are in vehicles without their own life support and IMV has failed to evaluate how long before the atmosphere is unsafe for the crew. This analysis uses the integrated nature of the GIEM to look at time to effect for O2 depletion and CO2 and H2O buildup when crew are working in vehicles that have been cut off from the ECLSS-active portion of the stack. This information is used to inform for how long crew can safely continue working in the ECLSS-inactive vehicles before experiencing a requirement violation or physical limitation and can be referenced when developing maintenance and emergency response concept of operations (ConOps).

Lawrence Barrett↗

Evaluation of the Accumulation of Foreign Object Debris in the International Space Station Ventilation Systems and Resulting Impacts to Systems

A challenge for the International Space Station (ISS) is accumulation of foreign object debris (FOD) in the ventilation systems and the impacts to crew, equipment, and experiments. One function of the temperature and humidity control system is to capture FOD with various methods of filtration to minimize these impacts. ISS filtration has been augmented by charcoal and High Efficiency Particulate Air (HEPA) filters and screens. A qualitative comparison of the quantity of FOD found since 2012 study and the current levels are evaluated. Impacts due to FOD are reduced air circulation, increased crew time for cleaning, reduction of equipment life, and component damage; examples are provided. Recommendations for further improvements to reduce the accumulation of FOD on ISS are provided.

ISS↗

Spacesuit Sizing by Multivariate Simulation: Case Study for Liquid Cooling and Ventilation Garment

A technique was developed to assess the fit of spacesuit garment liquid cooling and ventilation garment (LCVG). A fit scoring scheme was built from the spacesuit sizing requirements and guidelines, and the accommodated proportion of the wearer population was estimated from statistically synthesized pseudo population data. The method evaluated different scenarios of LCVG sizing systems including 1) baseline 7-size system, 2) 7-sizes with target body dimensions iteratively adjusted for maximum fit, and 3) 9-sizes with iterative adjustments. Overall, the baseline sizing system showed 81% accommodation rate, while the hypothetical new systems in-tegrating iterative adjustments for 7- and 9-sizes predictively indicated that accommodation could improve up to 92 and 97%. The proposed method provided a structured metric to quantify fit performance of a garment sizing system, which can be further applied to different spacesuit component, PPE and garment designs.

Han Kim↗

Heating, ventilation, air conditioning and refrigeration system

A heating, ventilation, air conditioning and refrigeration (HVAC/R) system includes a sorption circuit including a heat absorption heat exchanger in fluid communication with a primary fluid flow source such that a primary fluid flow from is directed therethrough. The heat absorption heat exchanger is configured to exchange thermal energy between the primary fluid flow and a secondary fluid flow. A sorption heat exchanger includes a sorbent material to adsorb or absorb the primary fluid flow, generating thermal energy. The sorption heat exchanger is configured to transfer the generated thermal energy to a tertiary fluid flow. A heat exchange circuit is in fluid communication with the sorption circuit and includes a control valves connected to both the secondary fluid flow and the tertiary fluid flow configured to selectably direct the secondary fluid flow and/or the tertiary fluid flow to a conditioning heat exchanger or an ambient heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Efficient Tool-Set for Modeling Containment Ventilation in Very Complex Facilities - 17215

The applicability of a multi-zone ventilation analysis program, CONTAM, to complex radioactive waste material handling or processing plants is evaluated. Validation results are based on simulations from three-dimensional multi-physics computational fluid dynamics. Insight into the application limits of CONTAM and conditions under which the use of higher fidelity tools are required are also discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Literature on Terminal Box Control, Occupancy Sensing Technology and Multi-zone Demand Control Ventilation (DCV)

This report presents an overall review of the standard requirement, the terminal box control, occupancy sensing technology and DCV. There is system-specific guidance for single-zone systems, but DCV application guidance for multi-zone variable air volume (VAV) systems is not available. No real-world implementation case studies have been found using the CO 2 -based DCV. The review results also show that the constant minimum air flow set point causes excessive fan power consumption and potential simultaneous heating and cooling. Occupancy-based control (OBC) is needed for the terminal box in order to achieve deep energy savings. Key to OBC is a technology for sensing the actual occupancy of the zone served in real time. Several technologies show promise, but none currently fully meets the need with adequate accuracy and sufficiently low cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Ventilation Cooling

The purpose of this measure guideline is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗