NEAMS Thermal-Fluids Test Stand for Fluoride-Slat Cooled, High Temperature Reactor Development (Final CRADA Report)
The work performed in this CRADA resulted in significant progress toward the development of a Thermal-fluid test-stand based on NEAMS tools. Significant work has been achieved in this area with simulations performed in Nek5000 of the heat and fluid flow in twisted tube heat exchangers and various software and modeling improvements in SAM geared toward heat exchanger simulations. In particular a set of simulations of flow and heat transfer in twisted elliptical tube geometries has been performed with Nek5000. The method was validated by simulating a case at a moderate Reynolds number and relatively high Froude number. This case was demonstrated to predict a Nusselt number in excellent agreement with the applicable correlation found in literature. It was further shown that at lower Froude numbers, this agreement becomes much worse. Additional cases were then simulated with low Froude numbers for both a square and a triangular unit cell to test the effect of pitch-to-maximum diameter ratio for the purposes of future CFD modeling. The results have proven invaluable to understand the flow physics in twisted tubes and provide reference data for design. Results have been summarized in a conference article. Moreover, work in SAM has led to significant improvement of software quality, the creation of a set of benchmarks for natural circulation and other significant software improvement.