Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tuning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Cavity-Modulation Autotuner For Hydrogen Maser

Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.

Dick, G. J.↗

The effect of a row of Helmholtz resonators on the turbulence in a boundary layer

Detailed acoustic measurements were made of the resonator's response as the free stream speed was varied from 30 mph to 155 mph. The average sound pressure level (SPL) and peak frequency response clearly show the existence of strong tuning between the boundary layer and the resonator for the Helmholtz (f sub 0) mode as well as for the first standing wave (f sub 1) mode. The narrow speed range for tuning and the gap between the strong tuning for the Helmholtz mode and the first standing wave mode is evident. The frequency at which the peak SPL response occurred at each speed is given. The peak response for the Helmholtz mode occurred at a free stream velocity of 26 m/s (at which RE sub theta = 6,560) with a resonant frequency of 570 Hz and a sound pressure level of 141 dB. The peak response for the first standing wave occurs at the maximum wind tunnel speed of 70 m/s (at which Re sub theta = 14,900) Hz with a resonant frequency of 1,890 Hz and a sound pressure level of 154 dB. At resonance the microphones do not maintain a constant SPL, but rather the latter fluctuates in a seemingly random fashion. The values presented here are time averaged rms values. Of interest was the occurrence of phase locking between adjacent resonators witha phase lag of 180 deg. This report covers the period from 5 May to 30 September on the subject project.

Panton, R. L.↗

Fraunhofer filters to reduce solar background for optical communications

A wavelength that lies within a spectral interval of reduced solar emission (a Fraunhofer line) can carry optical communications with reduced interference from direct or reflected background sunlight. Suitable Fraunhofer lines are located within the tuning range of good candidate lasers. The laser should be tunable dynamically to track Doppler shifts in the sunlight incident on any solar system body that may appear in the background as viewed by the receiver. A Fraunhofer filter used with a direct-detection receiver should be tuned to match the Doppler shifts of the source and background. The required tuning calculated here for various situations is also required if, instead, one uses a heterodyne receiver with limited post-detection bandwidth.

Kerr, E. L.↗

Fraunhofer filters to reduce solar background for optical communications

A wavelength that lies within a spectral interval of reduced solar emission (a Fraunhofer line) can carry optical communications with reduced interference from direct or reflected background sunlight. Suitable Fraunhofer lines are located within the tuning range of good candidate lasers. The laser should be tunable dynamically to track Doppler shifts in the sunlight incident on any solar system body that may appear in the background as viewed by the receiver. A Fraunhofer filter used with a direct-detection receiver should be tuned to match the Doppler shifts of the source and background. The required tuning calculated here for various situations is also required if, instead, one uses a heterodyne receiver with limited post-detection bandwidth.

Kerr, E. L.↗

Refinement of Earth's gravity field with Topex GPS measurements

The NASA Ocean Topography Experiment satellite TOPEX will carry a microwave altimeter accurate to a few centimeters for the measurement of ocean height. The capability can be fully exploited only if TOPEX altitude can be independently determined to 15 cm or better. This in turn requires an accurate gravity model. The gravity will be tuned with selected nine 10-day arcs of laser ranging, which will be the baseline tracking data type, collected in the first six months of TOPEX flight. TOPEX will also carry onboard an experimental Global Positioning System (GPS) flight receiver capable of simultaneously observing six GPS satellites above its horizon to demonstrate the capability of GPS carrier phase and P-code pseudorange for precise determination of the TOPEX orbit. It was found that subdecimeter orbit accuracy can be achieved with a mere two-hour arc of GPS tracking data, provided that simultaneous measurements are also made at six of more ground tracking sites. The precision GPS data from TOPEX are also valuable for refining the gravity model. An efficient technique is presented for gravity tuning using GPS measurements. Unlike conventional global gravity tuning, this technique solves for far fewer gravity parameters in each filter run. These gravity parameters yield local gravity anomalies which can later be combined with the solutions over other parts of the earth to generate a global gravity map. No supercomputing power will be needed for such combining. The approaches used in this study are described and preliminary results of a covariance analysis presented.

Wu, Sien-Chong↗

Hydrogen masers with cavity frequency switching servos

The stability of the free-running hydrogen maser is limited by pulling of the unperturbed hydrogen transition frequency due to instability of the cavity resonance frequency. While automatic spin-exchange tuning is in principle the more basic and accurate method, the required beam intensity switching and the long servo time constant result in reduced stability for measuring intervals up to 10(exp 6) seconds. More importantly, the spin-exchange tuning method requires a second stable frequency source as a reference, ideally a second hydrogen maser, to get the best results. The cavity frequency switching servo, on the other hand, has very little effect on the maser short term stability, and is fast enough to correct for cavity drift while maintaining the cavity at the spin-exchange tuned offset required to minimize instability due to beam intensity fluctuations. Not only does the cavity frequency switching servo not require a second stable frequency source, but the frequency reference is the atomic hydrogen radiated beam signal, so that no extra RF connections need be made to the cavity, and externally generated signals that would perturb the hydrogen atom need not be transmitted through the cavity. The operation of the cavity frequency switching stabilization method is discussed and the transient response of the servo and certain other aspects of the technique that have potential for achieving improved basic accuracy are illustrated.

Peters, Harry E.↗

Pulsed coherent solid-state 1.06-micron and 2.1-micron laser radar systems for remote velocity measurement

A low average power, pulsed, solid-state, 1.06-micron coherent laser radar (CLR) for range and velocity measurements of atmospheric and hard targets has been developed. The system has been operating at a field test site near Boulder, CO since September, 1988. Measurements have been taken on moving targets such as atmospheric aerosol particles, belt sanders, spinning disks, and various stationary targets. The field measurements have shown that this system exhibits excellent velocity measurement performance. A fast-tuning CW Nd:YAG oscillator has also been developed which has a frequency tuning range of greater than 30 GHz (which spans a target radial velocity range of over 16 km/s) and a tuning speed greater than 30 GHz/ms.

Henderson, Sammy W.↗

Sliding backshorts for planar circuits

An adjustable planar imbedding circuit based on coplanar transmission lines is presented to deal with the impedance mismatch associated with the use of the Superconductor-Insulator-Superconductor tunnel junction. The planar embedding circuit is developed with movable noncontacting shorting elements that consist of thin metallic plates with optimized arrangements of rectangular holes. The rectangular holes are placed along the insulated metallic transmission line to provide a periodic variation of the line impedance. A large reflection coefficient is demonstrated with a scale model of the sliding backshort, and values of more than -0.5 dB are reported. The shorting elements are incorporated into a low-frequency tuning circuit to test the practical tuning ranges. The backshort can be used to fashion tuning stubs with variable post-fabrication electrical lengths which relaxes the design constraints of planar integrated circuits.

Lubecke, Victor M.↗

Modal characterization of the ASCIE segmented optics testbed: New algorithms and experimental results

New frequency response measurement procedures, on-line modal tuning techniques, and off-line modal identification algorithms are developed and applied to the modal identification of the Advanced Structures/Controls Integrated Experiment (ASCIE), a generic segmented optics telescope test-bed representative of future complex space structures. The frequency response measurement procedure uses all the actuators simultaneously to excite the structure and all the sensors to measure the structural response so that all the transfer functions are measured simultaneously. Structural responses to sinusoidal excitations are measured and analyzed to calculate spectral responses. The spectral responses in turn are analyzed as the spectral data become available and, which is new, the results are used to maintain high quality measurements. Data acquisition, processing, and checking procedures are fully automated. As the acquisition of the frequency response progresses, an on-line algorithm keeps track of the actuator force distribution that maximizes the structural response to automatically tune to a structural mode when approaching a resonant frequency. This tuning is insensitive to delays, ill-conditioning, and nonproportional damping. Experimental results show that is useful for modal surveys even in high modal density regions. For thorough modeling, a constructive procedure is proposed to identify the dynamics of a complex system from its frequency response with the minimization of a least-squares cost function as a desirable objective. This procedure relies on off-line modal separation algorithms to extract modal information and on least-squares parameter subset optimization to combine the modal results and globally fit the modal parameters to the measured data. The modal separation algorithms resolved modal density of 5 modes/Hz in the ASCIE experiment. They promise to be useful in many challenging applications.

Carrier, Alain C.↗

Nonlinear rescaling of control values simplifies fuzzy control

Traditional control theory is well-developed mainly for linear control situations. In non-linear cases there is no general method of generating a good control, so we have to rely on the ability of the experts (operators) to control them. If we want to automate their control, we must acquire their knowledge and translate it into a precise control strategy. The experts' knowledge is usually represented in non-numeric terms, namely, in terms of uncertain statements of the type 'if the obstacle is straight ahead, the distance to it is small, and the velocity of the car is medium, press the brakes hard'. Fuzzy control is a methodology that translates such statements into precise formulas for control. The necessary first step of this strategy consists of assigning membership functions to all the terms that the expert uses in his rules (in our sample phrase these words are 'small', 'medium', and 'hard'). The appropriate choice of a membership function can drastically improve the quality of a fuzzy control. In the simplest cases, we can take the functions whose domains have equally spaced endpoints. Because of that, many software packages for fuzzy control are based on this choice of membership functions. This choice is not very efficient in more complicated cases. Therefore, methods have been developed that use neural networks or generic algorithms to 'tune' membership functions. But this tuning takes lots of time (for example, several thousands iterations are typical for neural networks). In some cases there are evident physical reasons why equally space domains do not work: e.g., if the control variable u is always positive (i.e., if we control temperature in a reactor), then negative values (that are generated by equal spacing) simply make no sense. In this case it sounds reasonable to choose another scale u' = f(u) to represent u, so that equal spacing will work fine for u'. In the present paper we formulate the problem of finding the best rescaling function, solve this problem, and show (on a real-life example) that after an optimal rescaling, the un-tuned fuzzy control can be as good as the best state-of-art traditional non-linear controls.

Vanlangingham, H.↗

Continuous-Wave, Diode-Pumped, Tunable Tm,Ho:YLF Laser

Unique features include high efficiency and tunability at wavelengths near 2.067 micrometers. Continuous-wave, diode-pumped Tm,Ho:YLF laser tuned by tilting Fabry-Perot etalon and/or adjusting temperature of Tm,Ho:YLF crystal. Proposed for use in remote sensing of winds and in remote sensing of CO2 and H2O, of which many strong absorption lines over-lap laser tuning range. Range extended by tuning to wave-length between CO2 and H2O absorption peaks.

Mcguckin, Brendan T.↗

On identified predictive control

Self-tuning control algorithms are potential successors to manually tuned PID controllers traditionally used in process control applications. A very attractive design method for self-tuning controllers, which has been developed over recent years, is the long-range predictive control (LRPC). The success of LRPC is due to its effectiveness with plants of unknown order and dead-time which may be simultaneously nonminimum phase and unstable or have multiple lightly damped poles (as in the case of flexible structures or flexible robot arms). LRPC is a receding horizon strategy and can be, in general terms, summarized as follows. Using assumed long-range (or multi-step) cost function the optimal control law is found in terms of unknown parameters of the predictor model of the process, current input-output sequence, and future reference signal sequence. The common approach is to assume that the input-output process model is known or separately identified and then to find the parameters of the predictor model. Once these are known, the optimal control law determines control signal at the current time t which is applied at the process input and the whole procedure is repeated at the next time instant. Most of the recent research in this field is apparently centered around the LRPC formulation developed by Clarke et al., known as generalized predictive control (GPC). GPC uses ARIMAX/CARIMA model of the process in its input-output formulation. In this paper, the GPC formulation is used but the process predictor model is derived from the state space formulation of the ARIMAX model and is directly identified over the receding horizon, i.e., using current input-output sequence. The underlying technique in the design of identified predictive control (IPC) algorithm is the identification algorithm of observer/Kalman filter Markov parameters developed by Juang et al. at NASA Langley Research Center and successfully applied to identification of flexible structures.

Bialasiewicz, Jan T.↗

Improvement in Suppression of Pulsed Nd:YAG Laser Light With Iodine Absorption Cells for Filtered Rayleigh Scattering Measurements

Filtered Rayleigh scattering using iodine absorption cells is an effective technique for obtaining density, temperature, and velocity measurements in high speed confined flows. By tuning a single frequency laser to a strong iodine absorption line, stray scattered laser light can be greatly suppressed. For example, the minimum transmission predicted by an iodine absorption model calculation is less than 10(exp -5) at the 18788.44/cm line using a 200 mm absorption cell containing iodine vapor at 0.46 T. Measurements obtained by other researches using a CW Nd:YAG laser agree with the model calculations. However, measurements made by us and by others using Q-switched, injection-seeded, frequency doubled Nd:YAG lasers only show minimum transmission of about 3 x 10(exp -3). This greatly reduces the applicability of the filtered Rayleigh scattering technique using these lasers in experiments having large amounts of stray scattered laser light. The purposes of the present study are to characterize the spectrum of the excess light transmitted by the iodine cell and to make changes to the laser to reduce the transmitted laser light. Transmission data as a function of laser frequency for the iodine absorption line at 18788.44/cm are presented. A planar mirror Fabry-Perot interferometer was used to characterize the frequency spectrum of the light passed through the cell. Measurements taken with the laser tuned to the center of the iodine absorption line show the light transmitted through the iodine cell to have a component with a bandwidth of about 40 GHz. This is probably caused by other modes in the laser that exist in spite of the single frequency injection beam. A second broadband component was also observed, possibly caused by the laser flash lamps or by fluorescence. An intracavity etalon was installed in the laser oscillator cavity to suppress the 40 GHz component. Measurements taken with the etalon tuned to the injection frequency showed a reduction in the transmitted laser light. This improvement allows the iodine cell to block significantly more of the stray laser light in filtered Rayleigh scattering experiments. Examples are given of filtered Rayleigh scattering measurements showing the effect of the etalon on measurements taken in a Mach 3 flow in the NASA Lewis 4 inch by 10 inch supersonic wind tunnel.

Seasholtz, Richard G.↗

Low-Noise Submillimeter-Wave NbTiN Superconducting Tunnel Junction Mixers

We have developed a low-noise 850 GHz superconductor-insulator-superconductor (SIS) quasi-particle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of T(sub RX) = 260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2(delta)/h is approximately 1.2THz.

Kawamura, J.↗

Remote Sensing of Rain

The first problem addressed concerns passive-microwave rain retrievals. Most current approaches start by building off-line a cloud-model-derived database. Given data, the retrieval algorithms search the database for the microwave temperatures "closest" to the observed data, then after some fine-tuning (performed in different ways by different implementations) the rain is estimated to be that which corresponds to the selected (and fine-tuned) set of database temperatures. These approaches have three drawbacks: they cannot properly take into account the ambiguities which arise from the fact that several rain scenarios can produce the same observed temperatures; they are quite inefficient since they require manipulating a large database along with often complex "fine-tuning" procedures; and they cannot refine their estimates if additional data is available. This past year we have derived closed formulae relating observed microwave brightness temperatures, T(sub b), and the underlying rain rates, R: average T(sub b) =f (rain) and average rain = g (T(sub b)), along with the corresponding covariance matrices. These results are sufficient to describe the conditional probabilities p(R/T(sub b)) and p(T(sub b)/R) to second order. Progress has also been made towards deriving a robust description of the rain drop size distribution (DSD). The widespread approach consisting in parameterizing the DSD as a gamma-distribution in terms of the drop diameter D suffers from the facts that, in reality, the DSD is not a smooth function of D and that the largely arbitrary Gamma model imposes unintended behavior, which has implications on any quantities derived from the DSD model. We have therefore developed a non-parametric yet practical description of the DSD, which is particularly well-suited for use in remote-sensing applications. The diagram on the left shows a comparison between an actual DSD sample and the truncated non-parametric representation. One figure shows the relation between radar reflectivity and rain rate derived using this representation. Validation of the Tropical Rainfall Measuring Mission (TRMM) radar-radiometer combined R and DSD algorithm is underway. This algorithm was designed to make optimal use of the instantaneous reflectivity profiles measured by the TRMM radar and the microwave brightness temperatures measured by the TRMM passive radiometer. So far, it appears to be the most reliable TRMM rain algorithm.

Haddad, Ziad S.↗

A Statistical Analysis of Laser Ablated Ba(Sub 0.50)Sr(Sub 0.50)TiO(Sub 3)/LaAlO(Sub 3) Films for Microwave Applications

The NASA Glenn Research Center is constructing a 616 element scanning phased array antenna using thin film Ba(sub x)Sr(sub 1-x)TiO(sub 3) based phase shifters. A critical milestone is the production of 616 identical phase shifters at 19 GHz with [asymptotically equal to]4 dB insertion loss and at least 337.5 deg phase shift with 3 percent bandwidth. It is well known that there is a direct relationship between dielectric tuning and loss due to the Kramers-Kronig relationship and that film crystallinity and strain, affected by the substrate template, play an important role. Ba(sub 0.50)Sr(sub 0.50)TiO (sub 3) films, nominally 400 nm thick, were deposited on 48 0.25 mm thick, 5 cm diameter LaAlO(sub 3) wafers. Although previous results suggested that Mn-doped films on MgO were intrinsically superior in terms of phase shift per unit loss, for this application phase shift per unit length was more important. The composition was selected as a compromise between tuning and loss for room temperature operation (e.g. crystallinity progressively degrades for Ba concentrations in excess of 30 percent). As a prelude to fabricating the array, it was necessary to process, screen, and inventory a large number of samples. Variable angle ellipsometry was used to characterize refractive index and film thickness across each wafer. Microstructural properties of the thin films were characterized using high resolution X-ray diffractometry. Finally, prototype phase shifters and resonators were patterned on each wafer and RE probed to measure tuning as a function of dc bias voltage as well as peak (0 field) permittivity and unloaded Q. The relationship among film quality and uniformity and performance is analyzed. This work presents the first statistically relevant study of film quality and microwave performance and represents a milestone towards commercialization of thin ferroelectric films for microwave applications.

Ferroelectric thin films↗

Advanced Controller Developed for the Free-Piston Stirling Convertor

A free-piston Stirling power convertor is being considered as an advanced power-conversion technology for future NASA deep-space missions requiring long-life radioisotope power systems. The NASA Glenn Research Center has identified key areas where advanced technologies can enhance the capability of Stirling energy-conversion systems. One of these is power electronic controls. Current power-conversion technology for Glenn-tested Stirling systems consists of an engine-driven linear alternator generating an alternating-current voltage controlled by a tuning-capacitor-based alternating-current peak voltage load controller. The tuning capacitor keeps the internal alternator electromotive force (EMF) in phase with its respective current (i.e., passive power factor correction). The alternator EMF is related to the piston velocity, which must be kept in phase with the alternator current in order to achieve stable operation. This tuning capacitor, which adds volume and mass to the overall Stirling convertor, can be eliminated if the controller can actively drive the magnitude and phase of the alternator current.

Gerber, Scott S.↗

Extremum-seeking control for an Ultrasonic/Sonic Driller/Corer (USDC) driven at high-power

Future NASA exploration missions will increasingly require sampling, in-situ analysis and possibly the return of material to Earth for further tests. One of the challenges to addressing this need is the ability to drill using for low axial loading while operating from light weight platforms (e.g., lander, rover, etc.) as well as operate at planets with low gravity. For this purpose, the authors developed the Ultrasonic/Sonic Driller/Corer (USDC) jointly with Cybersonics Inc. Studies of the operation of the USDC at high power have shown there is a critical need to self-tune to maintain the operation of the piezoelectric actuator at resonance. Performing such tuning is encountered with difficulties and to address them an extremum-seeking control algorithm is being investigated. This algorithm is designed to tune the driving frequency of a time-varying resonating actuator subjected to both random and high-power impulsive noise disturbances. Using this algorithm the performance of the actuator is monitored on a time-scale that is compatible with its slowly time-varying physical characteristics. The algorithm includes a parameter estimator, which estimates the coefficients of a function that characterizes the quality factor of the USDC. Since the parameter estimator converges sufficiently faster than the time-varying drift of the USDC's physical parameters, the proposed extremum-seeking estimation and control algorithm is potentially applicable for use as a closed-loop health monitoring system. Specifically, this system may be programmed to automatically adjust the duty-cycle of the sinusoidal driver signal to guarantee that the quality factor of the USDC does not fall below a user-defined set-point. Such fault-tolerant functionality is especially important in automated drilling applications where it is essential not to inadvertently drive the piezoelectric ceramic crystals of the USDC beyond their capacities. The details of the algorithm and experimental results will be described and discussed in this paper.

Peek-seeking estimation and control↗