Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Testing of Composite Stiffened Panels with Mid-Length Lateral Notches

Two hat-stiffened carbon-epoxy panels were loaded to failure to determine their failure load and mode under the Advanced Composites Project (ACP) Rapid Design Tools activity. Each specimen contained a lateral notch located at the mid-length location which severed the central stiffener. A description of the specimens, instrumentation, test fixtures and procedures is presented, followed by the presentation of the experimental results.

Dawn C Jegley↗

High-Resistivity Measurement System for Spacecraft Dielectrics

- Volume resistivity is a key material property needed for assessing the risk of electrostatic discharge (ESD) due to spacecraft charging. We have developed a volume resistivity test system capable of measuring volume resistivity ≥1019 Ω·cm in vacuum and at cryogenic temperatures. Key components of this new setup include a custom test fixture and very low noise battery voltage supply.

Chave, Robert↗

Lanthanum Strontium Cobaltite-Alumina Fiber Composite Contact Material for Solid Oxide Fuel Cells

Short alumina fibers were added to LSCo contact material to enhance the contact strength and improve thermal cycle stability. Alumina fiber from 2.5 v% to 20 v% were mixed with LSCo and sintered at elevated temperatures. Sintering study showed retardation in densification of LSCo matrix with increasing alumina content. Sintered bulk strength exhibited similar behavior where strength greatly reduced at high alumina v%. Coefficient of thermal expansion showed consistent results with prediction from rule of mixture. Contact strength using anode supported YSZ bilayer coupons improved greatly with the presence of small amount (2.5-5 v%) alumina fibers and no substantial reduction after 10 deep thermal cycles. Candidate LSCo-Al2O3 contact materials was validated in a generic stack test fixture for 1000h at 800oC followed by 10 thermal cycles. Results of impedance analysis showed substantial improvement in thermal cycle stability as compared to LSCo parent materials.

SOFC cathode, strength, LSCo, alumina↗

Hydrogen Component Leak Rate Quantification for System Risk and Reliability Assessment through QRA and PHM Frameworks: Preprint

The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems. This approach strives to use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA) to identify at-risk components, reduce component failures and downtime, and predict when components require maintenance. Hydrogen component failures increase facility maintenance cost, facility downtime, and reduce public acceptance of hydrogen technologies, ultimately increasing facility size and cost because of potentially overly conservative requirements. Leaks are a predominant failure mode for hydrogen components. However, uncertainties in the amount of hydrogen emitted from leaking components and the frequency of those failure events limit the understanding of the risks that they present under real-world operational conditions. NREL has deployed a test fixture, the Leak Rate Quantification Apparatus (LRQA), to quantify the mass flow rate of leaking gases from medium and high-pressure components that have failed while in service. Quantitative hydrogen leak rate data from this system could ultimately be used to better inform risk assessment and Regulation Codes and Standards (RCS). Parallel activity explores the use of PHM and QRA techniques to assess and reduce risk, thereby improving safety and reliability of hydrogen systems. The results of QRAs could further provide a systematic and science-based foundation for the design and implementation of RCS, as in the latest versions of the NFPA 2 code for gaseous hydrogen stations. Alternatively, data-driven techniques of PHM could provide new damage diagnosis and health-state prognosis tools. This research will help end users, station owners and operators, and regulatory bodies move towards risk-informed preventative maintenance versus emergency corrective maintenance, reducing cost and improving reliability. Predictive modelling of failures could improve safety and affect RCS requirements such as setback distances at liquid refuelling sites. The combination of leak rate quantification research, PHM, and QRA can lead to better informed models enabling data-based decision to be made for hydrogen system safety improvements.

codes and standards↗

Evaluating the Durability of Balance of Systems Components Using C-AST

The testing of branch- and cable-connectors, and fuses in C-AST is introduced. A significant effect was observed when mechanical actuation was introduced to the benchtop prototype testing. Therefore, this presentation emphasizes the mechanical test fixture, data acquisition system, failure analysis of the components used in specimen assemblies, and the validation of the results relative to field failed samples.

components↗

Development and Test of High Temperature Surface Acoustic Wave Gas Sensors

The demand for sensors in hostile environments, such as power plant environments, aerospace environments, oil and gas extraction, and high-temperature metallurgy environments, has risen over the past decades in a continuous attempt to increase process control, improve energy and process efficiency in production, reduce operational and maintenance costs, increase safety, and perform condition-based maintenance in equipment and structures operating in high-temperature harsh-environment conditions. The increased reliability, improved performance, and development of new sensors and networks with a multitude of components, especially wireless networks, are the target for operation in harsh environments. Gas sensors, in particular H2 sensors, operating above 200 C are required in the instrumentation, process control and general safety of a number of industries including coal, natural gas, and nuclear power generation facilities, the aerospace and automotive industries, metallurgical production and defense-related applications. The surface acoustic wave (SAW) platform is a particularly promising option for high-temperature, harsh-environment gas sensing applications since the platform exhibits advantages, such as battery-free and wireless operation, small size, possibility for scale production using well-developed technologies from the semiconductor industry, and low cost of installation and operation. In this work, one-port SAW resonators (SAWRs) operating along five different orientations on a commercially available langasite (LGS) wafer employing Pt-Al2O3 electrodes and reflectors were designed, fabricated, and used as high-temperature H2 sensors. Two of the selected orientations were predicted and confirmed to have temperature-compensated operation above 150 C. A gas sensor test setup was developed, capable of gas cycling between N2, O2 and N2/H2 mixtures under extended high-temperature periods (up to 650 C for over 20 hours). Thin film Pt-Al2O3 was used as the electrode material for the transducers and reflectors capable of high-temperature operation, and also as H2 sensing film. In addition, yttria-stabilized zirconia (YSZ) thin films with Pt decoration were tested as sensing films aimed to enhance the SAWR sensor response to H2. The SAW devices were monitored in excess of 1700 hours in real-time during gas cycling sequences up to 600 C, leading to the following findings: i) the Pt-Al2O3 electrodes performed better for H2 sensing than the Pt-decorated YSZ sensing film, showing as much as 50% higher frequency variation response in the 200 C to 400 C range; ii) different crystallographic orientations operating on the same LGS wafer experienced different responses to H2 exposures up to 500 C; iii) the surface oxidation state of the SAWR sensors was shown to have an important impact on subsequent H2 exposure responses. In addition, a sensor system employing two LGS SAWRs, aligned along two different orientations, has been developed to simultaneously determine H2 presence and temperature. Finally, wireless interrogation of a SAWR sensor was successful within the gas cycling test fixture, and successful wireless H2 detection was achieved above 400 C.

Ayes Moncada, Armando↗

Fixture For Hot Stress Tests Of Thin Specimens

Fixture designed to hold and heat thin, rectangular-cross-section specimen of composite material during hot lengthwise-stress test. Suitable for testing same specimen in either tension or compression. Clamps lightly onto specimen, providing both heat via thermal conduction and lateral support needed to prevent buckling during compression test.

Gates, Thomas S.↗

RF Testing Of Microwave Integrated Circuits

Fixtures and techniques are undergoing development. Four test fixtures and two advanced techniques developed in continuing efforts to improve RF characterization of MMIC's. Finline/waveguide test fixture developed to test submodules of 30-GHz monolithic receiver. Universal commercially-manufactured coaxial test fixture modified to enable characterization of various microwave solid-state devices in frequency range of 26.5 to 40 GHz. Probe/waveguide fixture is compact, simple, and designed for non destructive testing of large number of MMIC's. Nondestructive-testing fixture includes cosine-tapered ridge, to match impedance wavequide to microstrip. Advanced technique is microwave-wafer probing. Second advanced technique is electro-optical sampling.

Romanofsky, R. R.↗

Special test equipment and fixturing for MSAT reflector assembly alignment

The MSAT Reflector Assembly is a state of the art subsystem for Mobile Satellite (MSAT), a geosynchronous-based commercial mobile telecommunication satellite program serving North America. The Reflector Assembly consisted of a deployable, three-hinge, folding-segment Boom, deployable 5.7 x 5.3-meter 16-rib Wrap-Rib Reflector, and a Reflector Pointing Mechanism (RPM). The MSAT spacecraft was based on a Hughes HS601 spacecraft bus carrying two Reflector Assemblies independently dedicated for L-band transmit and receive operations. Lockheed Missiles and Space Company (LMSC) designed and built the Reflector Assembly for MSAT under contract to SPAR Aerospace Ltd. Two MSAT satellites were built jointly by SPAR Aerospace Ltd. and Hughes Space and Communications Co. for this program, the first scheduled for launch in 1994. When scaled for wavelength, the assembly and alignment requirements for the Reflector Assembly were in many instances equivalent to or exceeded that of a diffraction-limited visible light optical system. Combined with logistical constraints inherent to large, compliant, lightweight structures; 'bolt-on' alignment; and remote, indirect spacecraft access; the technical challenges were formidable. This document describes the alignment methods, the special test equipment, and fixturing for Reflector Assembly assembly and alignment.

Young, Jeffrey A.↗

Hybrid Residual Flexibility/Mass-Additive Method for Structural Dynamic Testing

A large fixture was designed and constructed for modal vibration testing of International Space Station elements. This fixed-base test fixture, which weighs thousands of pounds and is anchored to a massive concrete floor, initially utilized spherical bearings and pendulum mechanisms to simulate Shuttle orbiter boundary constraints for launch of the hardware. Many difficulties were encountered during a checkout test of the common module prototype structure, mainly due to undesirable friction and excessive clearances in the test-article-to-fixture interface bearings. Measured mode shapes and frequencies were not representative of orbiter-constrained modes due to the friction and clearance effects in the bearings. As a result, a major redesign effort for the interface mechanisms was undertaken. The total cost of the fixture design, construction and checkout, and redesign was over $2 million. Because of the problems experienced with fixed-base testing, alternative free-suspension methods were studied, including the residual flexibility and mass-additive approaches. Free-suspension structural dynamics test methods utilize soft elastic bungee cords and overhead frame suspension systems that are less complex and much less expensive than fixed-base systems. The cost of free-suspension fixturing is on the order of tens of thousands of dollars as opposed to millions, for large fixed-base fixturing. In addition, free-suspension test configurations are portable, allowing modal tests to be done at sites without modal test facilities. For example, a mass-additive modal test of the ASTRO-1 Shuttle payload was done at the Kennedy Space Center launch site. In this Technical Memorandum, the mass-additive and residual flexibility test methods are described in detail. A discussion of a hybrid approach that combines the best characteristics of each method follows and is the focus of the study.

Tinker, M. L.↗

Vibration Fixture Design and Testing for Rigid - Y Cable Mount on MMRTG F4

INL is responsible for the fueling and testing of Radioisotope Thermoelectric Generators for NASA space missions. For the upcoming NASA mission "DRAGONFLY," INL is tasked with fueling and testing the Multi-Mission Radioisotope Thermoelectric Generator F4 (MMRTG F4). This involves conducting various tests, such as vibration testing and mass properties testing. For these tests, an interface is required between the MMRTG and the testing equipment, provided by cables mounted on a legacy bracket. Due to design changes in the cooling lines, a new cable – the Rigid Y cable – is to be used. The test described in this poster was to verify if the Rigid Y cable would survive the vibration tests. The results will determine the procedure for conducting the vibration tests on the MMRTG F4.

42 - ENGINEERING↗

Free-Roller Versus Fixed-Roller Fixtures in Flexure Testing of Advanced Ceramic Materials

The error associated with strength measurements made with fixed-roller and V-grooved roller figures was studied with a variety of roller and figure material combinations. Both the fixed-roller and the V-grooved fixtures yielded an error in stress of about 4 to 7%. They also exhibited an appreciable amount of load strain hysteresis. Dynamic fatigue testing of 96 wt.% alumina verified the error: the fatigue strength was overestimated by 7 to 9% for the fixed roller configuration. The source of error is exclusively attributed to friction between the rollers and the specimen surface, as verified by previous investigators.

Salem, Jonathan A.↗

Design, fabrication, and initial test of a fixture for reducing the natural frequency of the Mod-O wind turbine tower

It was desired to observe the behavior of a two bladed wind turbine where the tower first bending natural frequency is less than twice the rotor speed. The system then passes through resonance when accelerating to operating speed. The frequency of the original Mod-O tower was reduced by placing it on a spring fixture. The fixture is adjustable to provide a range of tower bending frequencies. Fixture design details are given and behavior during initial operation is described.

Winemiller, J. R.↗

Biaxial compression test technique

Fixture and technique have been developed for predicting behavior of stiffened skin panels under biaxial compressive loading. Tester can load test panel independently in longitudinal and transverse directions. Data can also be obtained in combined mode.

Hansard, E. T.↗

TPSAS-NF1676L-13678-DND

An area that shows promise in enhancing structural integrity of aircraft and aerospace structures is integral stitched composite technology. The most recent generation of this technology is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. The goal of the PRSEUS concept is to provide damage-containment capability for composite structures while reducing overall structural weight. The National Aeronautics and Space Administration, the Boeing Company, and the Federal Aviation Administration (FAA) have partnered in an effort to assess the damage-containment features of a full-scale curved PRSEUS panel using the FAA Full-Scale Aircraft Structural Test Evaluation and Research facility. The background, test plan, fixture modifications, pre-test analysis, and planned experimental procedure were presented at the 2011 Aircraft Airworthiness and Sustainment Conference. This follow-on paper and presentation will provide details of the experimental procedure, test results, nondestructive inspection results, and preliminary test analysis comparison. The test program included three phases of loading and inspections: Phase I, as-built; Phase II, with barely visible impact damage (BVID); and Phase III, with a two-bay notch severing the central stiffener. Axial tension, internal pressure, and combined axial tension and internal pressure load conditions were applied during each phase using load levels that demonstrate compliance with the strength, deformation, and damage-tolerance requirements of Title 14 Code of Federal Regulations Part 25. Pressure loads were based on an operating pressure of 9.2 psi, designated as 1P, and the axial loads were based on a design limit load (DLL) of 227 kip. The Phase I test results provided a baseline. First, 50 percent limit-load levels were applied for each of the three load cases to verify proper load introduction and repeatability by examining strain and displacement results. Next, three limit-load cases were applied: limit pressure of 12.2 psi (1.33 P), axial DLL of 227 kip, and combined 1P pressure and axial DLL. Linear strain and displacement results were observed in all load cases. For Phase-II testing, the panel was impacted to introduce BVID with an energy of 40 ft-lb, with the impact located between the central stringer stitch line and flange edge. The impact created non-penetrating visual damage with fiber breaks and delamination between the skin and stringer flange. Limit-load conditions were applied followed by pressure overload of 18.4 psi (2P) and ultimate load conditions, defined as 1.5 times DLL. Inspections were performed after each load case; no damage growth was observed. For Phase-III testing, a two-bay notch was machined severing the central stiffener. The panel was then subjected to limit-load conditions, followed by combined 1P pressure while increasing axial tension load to catastrophic failure. As limit combined loads were approached, damage initiation was observed in the form of 45? splitting at 1P + 79% DLL. Axial loading was increased to 1P + 150 percent DLL causing damage to propagate to the adjacent stringer flanges. Damage was contained within the two-bay region by the stitching rows up to 1P + 176% DLL. Axial load was further increased until catastrophic failure, when a stringer rod failed at 1P + 192% DLL. These test results further verify the damage containment features of the PRSEUS concept and suggest its appropriateness for future flight vehicles.

Andrew Bergan↗

Test Adapter For Infrared Detectors

Convenient fixture for testing infrared detector integrated circuits, such as those used in surveying sensors, optical communications, receivers, optical power meters, and noncontacting thermometers. Includes electrical connections for 42-pin dual-in-line package (DIP), thermal connection to cryogenic probe, and optical filter. Using fixture, electrical and optical properties of detector measured at 4 K.

Campbell, Albert G.↗

Fixture For Compression-After-Impact Tests Of Thin Specimens

Special fixture holds specimen of laminated composite material in 20-klb (89-kN) or larger load frame for compression-after-impact test. In preparation for test, specimen damaged by dropping weight on it at known kinetic energy. During test, specimen loaded in compression, and load measured, until specimen fails. Measurement data used to characterize compressive strength of specimen after impact important indicator of ability of structural components made of composite material to tolerate damage. Tests give more-realistic measures of tolerance to damage.

Nettles, Alan T.↗