Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Fragmentation Prediction for a Brittle Ceramic: a Two-Scale Model Approach

Glass and oxide-ceramic radioactive material forms (e.g., PuO{sub 2}) are susceptible to brittle fracture during handling and transportation. Fracture of these materials may result in the generation of fragments small enough to become airborne, and thus easily dispersed and inhaled. Entrainment and dispersal of particles with dimensions less than 10 μm is generally anticipated under normal aerodynamic conditions. The assessment of the risk to the public and the environment from these materials due to events resulting in their fracture is based on the determination of the source term for environmental release. This source term is typically quantified by an airborne release fraction (ARF) and a respirable fraction (RF) of material generated by a given event. While the recommended empirical bounding values prove satisfactory to comply with the regulatory process for handling and transportation of these materials, they are based on test data for only a few materials subjected to a limited range of loading conditions. Because the final state of fragmentation (in terms of the size and distribution of fragments) is strongly dependent not only on the properties of the material and the energetic loading conditions that lead to breakup, but also on the many intrinsic length scales associated with fragmentation, it is difficult to precisely predict fragmentation characteristics for other brittle solid wastes forms subjected to a wider range of loading conditions based on the test data alone. The purpose of this manuscript is to present a two-scale modeling approach that may be used to simulate the dynamic fragmentation of brittle solid radioactive material forms subjected to general loading and boundary conditions. The method provides the resulting fragment characteristics (average size and size distribution) across the entire fragment range of interest. At the macro-scale, the approach uses a gradient damage elastic continuum mechanics material model within a finite element framework to simulate dynamic fracture under general loading and boundary conditions. Results from the macroscopic calculations are passed to a one-dimensional (1-D) lower length scale model that incorporates the relevant fine scale effects to determine the micro-scale fragmentation. This 1-D micro-scale fragmentation model simulates the internal crack nucleation and opening processes to predict the average fragment size and the fragment size distribution as a function of the material properties, loading conditions, and microscopic characteristic length scale of the material. Results from the lower length scale model are then combined with the macro-scale model fragmentation information to determine the resulting fragment size distribution spanning both length scales. This two-scale model has been exercised on a representative problem drawn from experimental studies, consisting of an impact of a falling weight onto a brittle ceramic. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Multiscale Modeling of the Mechanical Response of Silicon Carbide Composite Within the Accelerated Fuel Qualification Framework

The accelerated fuel qualification (AFQ) framework has been used for the initial development of multiscale modeling of silicon carbide (SiC) fiber reinforced composite (SiC-SiC). The AFQ framework provides a methodology to leverage physics-informed multiscale modeling along with a reduced set of empirical test data to reduce the time and cost of licensing and qualification of new nuclear fuel systems while maintaining the overall nuclear power plant safety case. SiC-SiC is being proposed for in-core applications, most notably fuel cladding, for current and next-generation nuclear reactors because of its high temperature stability, irradiation tolerance, and ability to withstand many accident conditions. As these composites exhibit multiscale architectures and complex microstructure-based fracture mechanics, it is an appealing use case for the AFQ methodology. While the end goal of this work is a single multiscale model that can be used for predictive in-core performance, current focus is on the individual various length scale models. Four individual models have been initially developed from microscale to engineering system level to capture key physics-based effects across different length scales. These models include a microscale homogenized tow model, a mesoscale fast Fourier transform–based weave model that integrates the homogenized tow model, a mesoscale finite element–based weave model, and a system-level BISON fuel performance model. Results of these models have undergone an initial comparison with separate-effects test data showing a good match to experimental results. By using the AFQ framework during model development, several near-term benefits have been secured including a reduction in development time for the SiC-SiC cladding, more targeted irradiation testing, and a better understanding of uncertainty.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary description of a new creep-fatigue design method that reduces over conservatism and simplifies the high temperature design process

The report provides the initial description of a new creep-fatigue design method for structural components in high temperature nuclear service. The new method is based on an integrated elastic-perfectly plastic (EPP) analysis and Simplified Model Test (SMT) approach that reduces over conservatism, improves the treatment of elastic follow up, and simplifies the design procedure, when compared with the current creep-fatigue design methods in ASME Boiler and Pressure Vessel Code. Developing the design charts for the EPP-SMT design method requires extrapolating SMT test data as a function of hold time and follow up factor. The report develops the preliminary design charts for Alloy 617 at temperatures between 800°C and 950°C by combining two extrapolation approaches developed in a previous work. The report also presents a comparative analysis between the EPP-SMT design method and the current ASME creep-fatigue design methods by evaluating design life of two sample geometries under different loading conditions. Results from the comparative analysis verify the EPP-SMT design charts but suggest the requirement of additional test data in the low strain range regime for improving the extrapolation procedure that will further reduce the over conservatism in the creep-fatigue damage evaluation. The report also concludes that the EPP-SMT design procedure can account for effect of primary load on creep-fatigue life by using a fixed, bounding value of follow up in constructing the design charts. The conclusions to this report describe the future work required to complete this new design method so it can be codified through a nuclear Code Case.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cummins R-SOFC System Development

The overall purpose of this project was to reduce the Reversible-Solid Oxide Fuel Cell (R-SOFC) system cost by developing two technologies, an improved cell design and the incorporation of an ejector in the fuel recycle loop instead of a blower. A Simulink model of the baseline SOFC system was developed and calibrated with experimental test data. The R-SOFC system model was built by integrating GT Suite developed models of the steam generation components into the baseline Simulink SOFC system model. The ability to run the stack in SOEC operating mode was also added to the model. The system model was used to explore the ability of the R-SOFC system to meet operational constraints on Steam/Carbon ratio and H2 concentration on the fuel side electrode. A CFD ejector model was developed and used to explore a range of ejector design parameters, leading to the final ejector design that was prototyped for testing. A prototype steam ejector was first tested in a laboratory environment using room temperature air. The steam ejector was subsequently tested using the full hot recycle loop with all relevant heat exchangers and steam generation components. The test conditions utilized temperatures, pressures, and flow rates expected in an R-SOFC application. Throughout the experimental testing work, ejector performance test data was used to improve and then validate the CFD ejector model. A CFD cell model was developed and used to optimize thermal gradients, voltage, and cost of a new cell substrate design. A CFD comparison of co-flow and cross-flow cell designs informed the decision to use a co-flow design for the new cell substrate. Multiple rounds of CFD simulation were used to improve the cell design to minimize the variation in air and fuel distribution across cell channels and to minimize the variation in air and fuel distribution across different cells in the stack. A few prototypes of the new cell substrate design were produced and validated in a laboratory environment by thermally spraying and verifying that they met established manufacturing specifications. The cell manufacturing process was adjusted in order to bring these metrics within acceptable tolerances. Cummins’ internal calculations show that the new cell design reduces cost ~50% compared to the baseline cell, while the ejector + superheater/boiler concept reduces cost of the recycle loop by ~40%. The impact of these cost reductions on the cost of producing H2 will depend on the specific system where they are applied. Therefore, a Techno-Economic Analysis was completed using system cost as a variable, and showing how the NREL Current and Future system costs translate into H2 production cost.

Henrichsen, Lars↗

Metal Angle Correction in the Cylinder Test

Cylinder test data shows that the copper wall angle increases with time in a given shot and becomes much larger if the wall is at half-thickness. The true velocity is suggested to be that perpendicular to the wall, and this brings full and half-wall data in closer agreement. The previously published Gurneytype equation for calculating the detonation energy density at each relative volume is modified by the angle of the wall and the angle of the measuring probe. This provides a unique solution to the energy density that does not require empirical coefficients or standards. We derive the length of the cone perpendicular to the cylinder surface and we use this as a description of the constant relative volume, creating a unified model for the first time. As a standard for full-wall cylinders, we obtain relative volumes of 2.43, 4.50 and 7.12 at the scaled wall displacements of 6, 12.5 and 19 mm. For a full-wall copper cylinder at the three points, the wall angles average 10.0, 11.0 and 11.6 degrees. Besides Cylinder test data on copper, previously unpublished framing camera pictures also measure angles for eight different metals. The angles are a function of wall thickness and relative volume but of nothing else, including the type of metal. For modeling, our simulation code calculates the wall velocity as seen along a particular probe direction, as this is a more realistic comparison to measurements than a zone particle velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal Angle Correction in the Cylinder Test

Cylinder test data shows that the copper wall angle increases with time in a given shot and becomes much larger if the wall is at half-thickness. The true velocity is suggested to be that perpendicular to the wall, and this brings full and half-wall data in closer agreement. The previously published Gurneytype equation for calculating the detonation energy density at each relative volume is modified by the angle of the wall and the angle of the measuring probe. This provides a unique solution to the energy density that does not require empirical coefficients or standards. We derive the length of the cone perpendicular to the cylinder surface and we use this as a description of the constant relative volume, creating a unified model for the first time. As a standard for full-wall cylinders, we obtain relative volumes of 2.43, 4.50 and 7.12 at the scaled wall displacements of 6, 12.5 and 19 mm. For a full-wall copper cylinder at the three points, the wall angles average 10.0, 11.0 and 11.6 degrees. Besides Cylinder test data on copper, previously unpublished framing camera pictures also measure angles for eight different metals. The angles are a function of wall thickness and relative volume but of nothing else, including the type of metal. For modeling, our simulation code calculates the wall velocity as seen along a particular probe direction, as this is a more realistic comparison to measurements than a zone particle velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Grid-Friendly Controls Demonstration Project for Utility-Scale PV Power Plants

A typical photovoltaic (PV) power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. The availability and dissemination of actual test data showing the viability of advanced utility-scale PV controls among all industry stakeholders can leverage PV's value from being simply an energy resource to providing additional ancillary services that range from variability smoothing and frequency regulation to power quality. Strategically partnering with a selected utility and/or PV power plant operator is a key condition for a successful demonstration project. The U.S. Department of Energy's (DOE's) Solar Energy Technologies Office selected the National Renewable Energy Laboratory (NREL) to be a principal investigator in a two-year project with goals to (1) identify a potential partner(s), (2) develop a detailed scope of work and test plan for a field project to demonstrate the gird-friendly capabilities of utility-scale PV power plants, (3) facilitate conducting actual demonstration tests, and (4) disseminate test results among industry stakeholders via a joint NREL/DOE publication and participation in relevant technical conferences. The project implementation took place in FY 2014 and FY 2015. In FY14, NREL established collaborations with AES and First Solar Electric, LLC, to conduct demonstration testing on their utility-scale PV power plants in Puerto Rico and Texas, respectively, and developed test plans for each partner. Both Puerto Rico Electric Power Authority and the Electric Reliability Council of Texas expressed interest in this project because of the importance of such advanced controls for the reliable operation of their power systems under high penetration levels of variable renewable generation. During FY15, testing was completed on both plants, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to provide various types of new grid-friendly controls.

14 SOLAR ENERGY↗

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid-state lighting life prediction using extended Kalman filter

Solid-state lighting (SSL) luminaires containing light emitting diodes (LEDs) have the potential of seeing excessive temperatures when being transported across country or being stored in non-climate controlled warehouses. They are also being used in outdoor applications in desert environments that see little or no humidity but will experience extremely high temperatures during the day. This makes it important to increase our understanding of what effects high temperature exposure for a prolonged period of time will have on the usability and survivability of these devices. The U.S. Department of Energy has made a long term commitment to advance the efficiency, understanding and development of solid-state lighting (SSL) and is making a strong push for the acceptance and use of SSL products to reduce overall energy consumption attributable to lighting. Traditional light sources “burn out” at end-of-life. For an incandescent bulb, the lamp life is defined by B50 life. However, the LEDs have no filament to “burn”. The LEDs continually degrade and the light output decreases eventually below useful levels causing failure. Presently, the TM-21 test standard is used to predict the L70 life of SSL Luminaires from LM-80 test data. The TM-21 model uses an Arrhenius Equation with an Activation Energy, Pre-decay factor and Decay Rates. Several failure mechanisms may be active in a luminaire at a single time causing lumen depreciation. The underlying TM-21 Arrhenius Model may not capture the failure physics in presence of multiple failure mechanisms. Correlation of lumen maintenance with underlying physics of degradation at system-level is needed. In this paper, a Kalman Filter and Extended Kalman Filters have been used to develop a 70% Lumen Maintenance Life Prediction Model for a LEDs used in SSL luminaires. This model can be used to calculate acceleration factors, evaluate failure-probability and identify ALT methodologies for reducing test time. Ten-thousand hour LM-80 test data for various LEDs have been used for model development. System state has been described in state space form using the measurement of the feature vector, velocity of feature vector change and the acceleration of the feature vector change. System state at each future time has been computed based on the state space at preceding time step, system dynamics matrix, control vector, control matrix, measurement matrix, measured vector, process noise and measurement noise. The future state of the lumen depreciation has been estimated based on a second order Kalman Filter model and a Bayesian Framework. The measured state variable has been related to the underlying damage using physics-based models. Life prediction of L70 life for the LEDs used in SSL luminaires from KF and EKF based models have been compared with the TM-21 model predictions and experimental data.

54 ENVIRONMENTAL SCIENCES↗

Scrape-off layer reflectometer for Alcator C-Mod

A swept-frequency X-mode reflectometer is being built for Alcator C-Mod to measure the scrape-off layer density profiles at the top, middle, and bottom locations in front of both the new lower hybrid launcher and the new ion cyclotron range of frequencies antenna. The system is planned to operate between 100 and 146 GHz at sweep rates from 10 {mu}s to 1 ms, and will cover a density range of approximately 10{sup 16}-10{sup 20} m{sup -3} at B{sub 0}=5-5.4 T. To minimize the effects of density fluctuations, both differential phase and full phase reflectometry will be employed. Design, test data, and calibration results of this electronics system will be discussed. To reduce attenuation losses, tallguide (TE{sub 01}) will be used for most of the transmission line system. Simulations of high mode conversion in tallguide components, such as e-plane hyperbolic secant radius of curvature bends, tapers, and horn antennas will be shown. Experimental measurements of the total attenuation losses of these components in the lower hybrid waveguide run will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Wave Energy Converter Control Competition: Overview

Over the past two years, a wave energy converter control systems competition (WECCCOMP) has been in progress, with the objective of comparing different wave energy converter (WEC) control paradigms on a standard benchmark problem. The target system is a point absorber, corresponding to a single float with an absolute reference, of the WaveStar WEC prototype. The system was modelled in WEC-Sim, with the hydrodynamic parameters validated against tank test data. Competitors were asked to design and implement a WEC control system for this model, with performance evaluated across six sea states. The evaluation criteria included a weighted combination of average converted power, peak/average power, and the degree to which the system physical constraints were exploited or temporarily exceeded.

16 TIDAL AND WAVE POWER↗

Life-cycle implications of hydrogen fuel cell electric vehicle technology for medium- and heavy-duty trucks

This study provides a comprehensive and up-to-date life-cycle comparison of hydrogen fuel cell electric trucks (FCETs) and their conventional diesel counterparts in terms of energy use and air emissions, based on the ensemble of well-established methods, high-fidelity vehicle dynamic simulations, and real-world vehicle test data. For the centralized steam methane reforming (SMR) pathway, hydrogen FCETs reduce life-cycle or well-to-wheel (WTW) petroleum energy use by more than 98% compared to their diesel counterparts. The reduction in WTW air emissions for gaseous hydrogen (G.H2) FCETs ranges from 20-45% for greenhouse gases, 37-65% for VOC, 49-77% for CO, 62-83% for NOx, 19-43% for PM10, and 27-44% for PM2.5, depending on vehicle weight classes and truck types. With the current U.S. average electricity generation mix, FCETs tend to create more WTW SOx emissions than their diesel counterparts, mainly because of the upstream emissions related to electricity use for hydrogen compression/liquefaction. Compared to G.H2, liquid hydrogen (L.H2) FCETs generally provide smaller WTW emissions reductions. For both G.H2 and L.H2 pathways for FCETs, because of electricity consumption for compression and liquefaction, spatio-temporal variations of electricity generation can affect the WTW results. FCETs retain the WTW emission reduction benefits, even when considering aggressive diesel engine efficiency improvement.

air emissions↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Total Thermal Management of Battery Electric Vehicles (BEVs)

The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

Chowdhury, Sourav↗

Effects of random forest modeling decisions on biogeochemical time series predictions

Abstract Random forests (RF) are an increasingly popular machine learning approach used to model biogeochemical processes in the Earth system. While RF models are robust to many assumptions that complicate deterministic models, there are several important parameterization decisions for appropriate use and optimal model fit. We explored the role that parameter decisions, including training/testing data splitting strategies, variable selection, and hyperparameters play on RF goodness‐of‐fit by constructing models using 1296 unique parameter combinations to predict concentrations of nitrate, a key nutrient for biogeochemical cycling in aquatic ecosystems. Models were built on long‐term, publicly available water quality and meteorology time series collected by the National Estuarine Research Reserve monitoring network for two contrasting ecosystems representing freshwater and brackish estuaries. We found that accounting for temporal dependence when splitting data into training and testing subsets was key for avoiding over‐estimation of model predictive power. In addition, variable selection, the ratio of training to testing data, and to a lesser degree, variables per split and number of trees, were significant parameters for optimizing RF goodness‐of‐fit. We also explored how model parameter decisions influenced interpretation of the relative importance of predictors to the model, and model predictor‐dependent variable relationships, with results suggesting that both data structure and model parameterization influence these factors. Because much of the current RF literature is written for the computational and statistical science communities, the primary goal of this study is to provide guidelines for aquatic scientists new to machine learning to apply RF techniques appropriately to aquatic biogeochemical datasets.

54 ENVIRONMENTAL SCIENCES↗

Fault-tolerant grid frequency measurement algorithm during transients

Many critical electric grid operations rely on accurate grid frequency measurements. Unfortunately, the measurement accuracy can be easily undermined by power system transient faults. During a power system transient fault, the power grid voltages and currents are usually highly distorted by high-frequency components. What is worse, the power grid signals could have discontinuity during some system transient faults such as phase angle jump, and the discontinuity could result in large measurement errors to state-of-the-art grid measurement algorithms. In this study, a fault-tolerant grid frequency measurement algorithm during transients is proposed. The new algorithm consists of two stages. The first stage is a transient detector, and it can detect the occurrence of system transient faults instantaneously. The second stage is the intelligent frequency estimator, and it will adapt its measurements according to the transient detector. The performance of the algorithm is evaluated under different steady-state and transient conditions. Both dependability and security of the fault-tolerant algorithm are assessed by using PSCAD simulation data and IEEE Standard test data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wave Energy Converter Power Take-Off Modeling and Validation From Experimental Bench Tests

This article describes the implementation of a new numerical model of the power take-off system installed in the Monterey Bay Aquarium Research Institute wave energy converter, a device developed to provide power to various oceanic research missions. The simultaneous presence of hydraulic, pneumatic, and electrical subsystems in the power take-off system represents a significant challenge in forging an accurate model able to replicate the main dynamic characteristics of the system. The validation of the new numerical model is addressed by comparing simulations with the measurements obtained during a series of bench tests. Data from the bench tests show good agreement with the numerical model. The validated model provides deeper insights into the complex nonlinear dynamics of the power take-off system and will support further performance improvements in the future.

16 TIDAL AND WAVE POWER↗